Skip to main content
Erschienen in: International Orthopaedics 7/2014

01.07.2014 | Original Paper

Repeated metal ion measurements in patients with high risk metal-on-metal hip replacement

verfasst von: Aleksi Reito, Teemu Moilanen, Timo Puolakka, Jorma Pajamäki, Antti Eskelinen

Erschienen in: International Orthopaedics | Ausgabe 7/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Conventional follow-up methods are not sufficient to identify adverse soft tissue reactions in patients with metal-on-metal hip replacements. The national guidelines regarding metal ion measurements are debatable. The aims of our study were to investigate (1) if there is a clinically significant change in whole blood (WB) cobalt (Co) or chrome (Cr) levels in repeated WB assessment in patients operated on with ASR hip replacements, and (2) what proportion of patients has WB Co or Cr level below the previously established safe upper limits (SUL) in the repeated WB metal ion assessment.

Methods

We identified all patients (n = 254) with unilateral ASR implants who had second blood sample taken eight to 16 months after the first.

Results

WB Co and Cr levels remained below SUL and within their initial values during a mean one-year measurement interval in the majority of patients with a high risk HR device. In contrast to this, 50 % of patients with THRs had metal ion levels exceeding the SUL in the first measurement. WB Co values significantly increased over the measurement interval in the THR group.

Conclusion

In patients with a high risk HR, repeated metal ion measurement did not provide useful information for clinical decision-making. In patients with a LD MoM THR repeated measurements revealed a large number of patients with metal ion levels exceeding SUL and might thus be clinically beneficial.
Literatur
1.
Zurück zum Zitat Bosker BH, Ettema HB, Boomsma MF, Kollen BJ, Maas M, Verheyen CC (2012) High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement: a prospective cohort study. J Bone Joint Surg (Br) 94(6):755–761CrossRef Bosker BH, Ettema HB, Boomsma MF, Kollen BJ, Maas M, Verheyen CC (2012) High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement: a prospective cohort study. J Bone Joint Surg (Br) 94(6):755–761CrossRef
2.
Zurück zum Zitat Reito A, Puolakka T, Elo P, Pajamaki J, Eskelinen A (2013) High prevalence of adverse reactions to metal debris in small-headed ASR hips. Clin Orthop Relat 471(9):2954–2961CrossRef Reito A, Puolakka T, Elo P, Pajamaki J, Eskelinen A (2013) High prevalence of adverse reactions to metal debris in small-headed ASR hips. Clin Orthop Relat 471(9):2954–2961CrossRef
3.
Zurück zum Zitat Bisschop R, Boomsma MF, Van Raay JJ, Tiebosch AT, Maas M, Gerritsma CL (2013) High prevalence of pseudotumors in patients with a Birmingham hip resurfacing prosthesis: a prospective cohort study of one hundred and twenty-nine patients. J Bone Joint Surg Am 95(17):1554–1560PubMedCrossRef Bisschop R, Boomsma MF, Van Raay JJ, Tiebosch AT, Maas M, Gerritsma CL (2013) High prevalence of pseudotumors in patients with a Birmingham hip resurfacing prosthesis: a prospective cohort study of one hundred and twenty-nine patients. J Bone Joint Surg Am 95(17):1554–1560PubMedCrossRef
4.
Zurück zum Zitat Donell ST, Darrah C, Nolan JF, Wimhurst J, Toms A, Barker TH (2010) Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs. J Bone Joint Surg (Br) 92(11):1501–1508CrossRef Donell ST, Darrah C, Nolan JF, Wimhurst J, Toms A, Barker TH (2010) Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs. J Bone Joint Surg (Br) 92(11):1501–1508CrossRef
5.
Zurück zum Zitat Anderson H, Toms AP, Cahir JG, Goodwin RW, Wimhurst J, Nolan JF (2011) Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system. Skelet Radiol 40(3):303–307CrossRef Anderson H, Toms AP, Cahir JG, Goodwin RW, Wimhurst J, Nolan JF (2011) Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system. Skelet Radiol 40(3):303–307CrossRef
6.
Zurück zum Zitat Nishii T, Sakai T, Takao M, Yoshikawa H, Sugano N (2012) Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings. J Arthroplasty 27(6):895–900PubMedCrossRef Nishii T, Sakai T, Takao M, Yoshikawa H, Sugano N (2012) Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings. J Arthroplasty 27(6):895–900PubMedCrossRef
7.
Zurück zum Zitat Hart AJ, Sabah SA, Bandi AS, Maggiore P, Tarassoli P, Sampson B (2011) Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg (Br) 93(10):1308–1313CrossRef Hart AJ, Sabah SA, Bandi AS, Maggiore P, Tarassoli P, Sampson B (2011) Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg (Br) 93(10):1308–1313CrossRef
8.
Zurück zum Zitat De Pasquale D, Stea S, Squarzoni S, Bordini B, Amabile M, Catalani S (2013) Metal-on-metal hip prostheses: Correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream. Int Orthop 2013 Oct 12 De Pasquale D, Stea S, Squarzoni S, Bordini B, Amabile M, Catalani S (2013) Metal-on-metal hip prostheses: Correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream. Int Orthop 2013 Oct 12
9.
Zurück zum Zitat Clarke IC, Donaldson T, Bowsher JG, Nasser S, Takahashi T (2005) Current concepts of metal-on-metal hip resurfacing. Orthop Clin N Am 36(2):143–162CrossRef Clarke IC, Donaldson T, Bowsher JG, Nasser S, Takahashi T (2005) Current concepts of metal-on-metal hip resurfacing. Orthop Clin N Am 36(2):143–162CrossRef
10.
Zurück zum Zitat Daniel J, Ziaee H, Pradhan C, McMinn DJ (2009) Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. J Bone Joint Surg (Br) 91(2):176–179CrossRef Daniel J, Ziaee H, Pradhan C, McMinn DJ (2009) Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. J Bone Joint Surg (Br) 91(2):176–179CrossRef
11.
Zurück zum Zitat Maurer-Ertl W, Friesenbichler J, Sadoghi P, Pechmann M, Trennheuser M, Leithner A (2012) Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty - Preliminary results of a prospective five year study after two years of follow-up. BMC Musculoskelet Disord 13(1):56PubMedCentralPubMedCrossRef Maurer-Ertl W, Friesenbichler J, Sadoghi P, Pechmann M, Trennheuser M, Leithner A (2012) Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty - Preliminary results of a prospective five year study after two years of follow-up. BMC Musculoskelet Disord 13(1):56PubMedCentralPubMedCrossRef
12.
Zurück zum Zitat Garbuz DS, Tanzer M, Greidanus NV, Masri BA, Duncan CP (2010) The John Charnley Award: metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res 468(2):318–325PubMedCentralPubMedCrossRef Garbuz DS, Tanzer M, Greidanus NV, Masri BA, Duncan CP (2010) The John Charnley Award: metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res 468(2):318–325PubMedCentralPubMedCrossRef
13.
Zurück zum Zitat Bernstein M, Desy NM, Petit A, Zukor DJ, Huk OL, Antoniou J (2012) Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty. Int Orthop 36(9):1807–1812PubMedCentralPubMedCrossRef Bernstein M, Desy NM, Petit A, Zukor DJ, Huk OL, Antoniou J (2012) Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty. Int Orthop 36(9):1807–1812PubMedCentralPubMedCrossRef
16.
Zurück zum Zitat Van Der Straeten C, Grammatopoulos G, Gill HS, Calistri A, Campbell P, De Smet KA (2012) The 2012 Otto Aufranc award: the interpretation of metal ion levels in unilateral and bilateral hip resurfacing. Clin Orthop Relat Res 471(2):377–385CrossRef Van Der Straeten C, Grammatopoulos G, Gill HS, Calistri A, Campbell P, De Smet KA (2012) The 2012 Otto Aufranc award: the interpretation of metal ion levels in unilateral and bilateral hip resurfacing. Clin Orthop Relat Res 471(2):377–385CrossRef
18.
Zurück zum Zitat Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV (2010) Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg (Br) 92(1):38–46CrossRef Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV (2010) Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg (Br) 92(1):38–46CrossRef
19.
Zurück zum Zitat Langton DJ, Sprowson AP, Joyce TJ, Reed M, Carluke I, Partington P (2009) Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham hip resurfacing arthroplasties. J Bone Joint Surg (Br) 91(10):1287–1295CrossRef Langton DJ, Sprowson AP, Joyce TJ, Reed M, Carluke I, Partington P (2009) Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham hip resurfacing arthroplasties. J Bone Joint Surg (Br) 91(10):1287–1295CrossRef
20.
Zurück zum Zitat Beaule PE, Kim PR, Hamdi A, Fazekas A (2011) A prospective metal ion study of large-head metal-on-metal bearing: a matched-pair analysis of hip resurfacing versus total hip replacement. Orthop Clin N Am 42(2):251–257CrossRef Beaule PE, Kim PR, Hamdi A, Fazekas A (2011) A prospective metal ion study of large-head metal-on-metal bearing: a matched-pair analysis of hip resurfacing versus total hip replacement. Orthop Clin N Am 42(2):251–257CrossRef
21.
Zurück zum Zitat deSouza RM, Parsons NR, Oni T, Dalton P, Costa M, Krikler S (2010) Metal ion levels following resurfacing arthroplasty of the hip: serial results over a ten-year period. J Bone Joint Surg (Br) 92(12):1642–1647CrossRef deSouza RM, Parsons NR, Oni T, Dalton P, Costa M, Krikler S (2010) Metal ion levels following resurfacing arthroplasty of the hip: serial results over a ten-year period. J Bone Joint Surg (Br) 92(12):1642–1647CrossRef
22.
Zurück zum Zitat Matthies AK, Racasan R, Bills P, Blunt L, Cro S, Panagiotidou A (2013) Material loss at the taper junction of retrieved large head metal-on-metal total hip replacements. J Orthop Res 31(11):1677–1685PubMed Matthies AK, Racasan R, Bills P, Blunt L, Cro S, Panagiotidou A (2013) Material loss at the taper junction of retrieved large head metal-on-metal total hip replacements. J Orthop Res 31(11):1677–1685PubMed
Metadaten
Titel
Repeated metal ion measurements in patients with high risk metal-on-metal hip replacement
verfasst von
Aleksi Reito
Teemu Moilanen
Timo Puolakka
Jorma Pajamäki
Antti Eskelinen
Publikationsdatum
01.07.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 7/2014
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2300-7

Weitere Artikel der Ausgabe 7/2014

International Orthopaedics 7/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie