Skip to main content
Erschienen in: International Orthopaedics 9/2017

27.06.2017 | Original Paper

Efficiency of fragment specific fixation plates in the treatment of comminuted distal radial fractures

verfasst von: Elhadi Musaab Elhadi Babikir, Eyad Daood Al-Maqdassy, Khalid Hasan, Shamsi Abdul Hameed, Abduljabbar Alhammoud, Mohammed Mubarak Al-Ateeq Al-Dosari

Erschienen in: International Orthopaedics | Ausgabe 9/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to assess the clinical, radiologic and functional outcome of treating comminuted intra-articular distal radius fractures with fragment specific fixation.

Methods

This was a retrospective chart review of 25 unstable intra-articular distal radius fractures (type C2 AO) that had fragment specific fixation done in the orthopaedic department of the Hamad General Hospital (level 1 trauma center) over three years (2010–2013), with a follow up of one year post-operatively. Pre-operative X-rays (wrist parameters) were compared to post-operative X-rays at different time points (i.e. 6 weeks, 3 months, 6 months, etc.). Range of motion and grip strength were recorded at different time points until the final follow up evaluation. All the data has been obtained from patients’ charts (including outpatient and occupational therapy rehabilitation range of motion data) after final approval from the Hamad Corporation medical research center/Ethics committee.

Results

There were 25 patients ranging in age from 24 to 58 years with 13 patients above 35 years (52%) and 12 patients below 35 years (48%). There were 22 males (88%) and 3 females (12%) with different mechanisms of injury such as falling from height (average 2 metres), which was the most common with 13 patients (52%), and most were work related. Left wrist was more common than right wrist injuries and mostly in the non-dominant hand with 14 patients (56%). There was an obvious improvement between pre and post-operative wrist parameters at different time points, but P-values were not significant; supination and pronation at six weeks of follow up showed significant values (p = 0.04 & 0.03, respectively). Grip strength improved about 76% compared to the normal side.

Conclusions

Fragment specific fixation is a reasonable alternative for treating intra-articular distal radius fractures. At final follow up evaluations, results showed a better clinical, radiological and functional outcome. Stable fixation allowed starting active and passive motion of the wrist without compromising post-operative alignment.
Literatur
1.
Zurück zum Zitat Schadel HM, Iwinska ZJ, Bohringer G et al (2001) MRI or arthroscopy in the diagnosis of scapholunate ligament tears in fractures of the distal radius? Handchir Mikrochir Plast Chir 33(4):234–238CrossRef Schadel HM, Iwinska ZJ, Bohringer G et al (2001) MRI or arthroscopy in the diagnosis of scapholunate ligament tears in fractures of the distal radius? Handchir Mikrochir Plast Chir 33(4):234–238CrossRef
2.
Zurück zum Zitat Wirth MA, Rockwood CA Jr (1996) Acute and chronic traumatic injuries of the sternoclavicular joint. J Am Acad Orthop Surg 4(5):268–278CrossRefPubMed Wirth MA, Rockwood CA Jr (1996) Acute and chronic traumatic injuries of the sternoclavicular joint. J Am Acad Orthop Surg 4(5):268–278CrossRefPubMed
4.
Zurück zum Zitat Dodds SD, Cornelissen S, Jossan S, Wolfe SW (2002) A biomechanical comparison of fragment-specific fixation and augmented external fixation for intra-articular distal radius fractures. J Hand Surg 27(6):953–964CrossRef Dodds SD, Cornelissen S, Jossan S, Wolfe SW (2002) A biomechanical comparison of fragment-specific fixation and augmented external fixation for intra-articular distal radius fractures. J Hand Surg 27(6):953–964CrossRef
5.
Zurück zum Zitat Taylor KF, Parks BG, Segalman KA (2006) Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: cyclic testing in a C2-type distal radius cadaver fracture model. J Hand Surg 31(30):373–381CrossRef Taylor KF, Parks BG, Segalman KA (2006) Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: cyclic testing in a C2-type distal radius cadaver fracture model. J Hand Surg 31(30):373–381CrossRef
6.
Zurück zum Zitat Schumer ED, Leslie BM (2005) Fragment-specific fixation of distal radius fractures using the Trimed device. Tech Hand Upper Extrem Surg 9:74–83CrossRef Schumer ED, Leslie BM (2005) Fragment-specific fixation of distal radius fractures using the Trimed device. Tech Hand Upper Extrem Surg 9:74–83CrossRef
7.
Zurück zum Zitat Swigart CR, Wolfe SW (2001) Limited incision open techniques for distal radius fracture management. Orthop Clin North Am 30:317–327CrossRef Swigart CR, Wolfe SW (2001) Limited incision open techniques for distal radius fracture management. Orthop Clin North Am 30:317–327CrossRef
8.
Zurück zum Zitat Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg 29:96–102CrossRef Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg 29:96–102CrossRef
9.
Zurück zum Zitat Konrath GA, Bahler S (2002) Open reduction and internal fixation of unstable distal radius fractures: results using the Trimed fixation system. J Orthop Trauma 16:578–585CrossRefPubMed Konrath GA, Bahler S (2002) Open reduction and internal fixation of unstable distal radius fractures: results using the Trimed fixation system. J Orthop Trauma 16:578–585CrossRefPubMed
10.
Zurück zum Zitat Harness NG, Jupiter JB, Orbay JL, Raskin KB, Fernandez DL (2004) Loss of fixation of the volar lunate facet fragment in fractures of the distal part of the radius. J Bone Joint Surg 86:1900–1908CrossRefPubMed Harness NG, Jupiter JB, Orbay JL, Raskin KB, Fernandez DL (2004) Loss of fixation of the volar lunate facet fragment in fractures of the distal part of the radius. J Bone Joint Surg 86:1900–1908CrossRefPubMed
11.
Zurück zum Zitat Douglas MS, Kevin CC (2008) A comparative study of fragment specific versus volar plate fixation of distal radius fractures. Plast Reconstr Surg 122:1441CrossRef Douglas MS, Kevin CC (2008) A comparative study of fragment specific versus volar plate fixation of distal radius fractures. Plast Reconstr Surg 122:1441CrossRef
12.
Zurück zum Zitat Zhang B, Chang H, Yu K, Bai J, Tian D, Zhang G, Shao X, Zhang Y (2017) Intramedullary nail versus volar locking plate fixation for the treatment of extra-articular or simple intra-articular distal radius fractures: systematic review and meta-analysis. Int Orthop. doi:10.1007/s00264-017-3460-z Zhang B, Chang H, Yu K, Bai J, Tian D, Zhang G, Shao X, Zhang Y (2017) Intramedullary nail versus volar locking plate fixation for the treatment of extra-articular or simple intra-articular distal radius fractures: systematic review and meta-analysis. Int Orthop. doi:10.​1007/​s00264-017-3460-z
15.
Zurück zum Zitat Grindel IG, Wang M, Gerlach M, McGrady LM, Brown S (2007) Biomechanical comparison of fixed angle volar plate versus fixed angle volar plate plus fragment specific fixation in a cadaveric distal radius fracture model. J Hand Surg 32(2):194–199CrossRef Grindel IG, Wang M, Gerlach M, McGrady LM, Brown S (2007) Biomechanical comparison of fixed angle volar plate versus fixed angle volar plate plus fragment specific fixation in a cadaveric distal radius fracture model. J Hand Surg 32(2):194–199CrossRef
16.
Zurück zum Zitat Leon SB, Keith PM (2006) The outcome of intra-articular distal radius fractures treated with fragment-specific fixation. J Hand Surg 31:1333–1339CrossRef Leon SB, Keith PM (2006) The outcome of intra-articular distal radius fractures treated with fragment-specific fixation. J Hand Surg 31:1333–1339CrossRef
17.
Zurück zum Zitat Knirk JL, Jupiter JB (1986) Intra-articular fractures of the distal end of the radius in young adults. J Bone Joint Surg Am 68(5):647–659CrossRefPubMed Knirk JL, Jupiter JB (1986) Intra-articular fractures of the distal end of the radius in young adults. J Bone Joint Surg Am 68(5):647–659CrossRefPubMed
18.
Zurück zum Zitat Melonce PJR (1993) Distal radius fractures: patterns of articular fragmentation. Orthop Clin North Am 24:239–253 Melonce PJR (1993) Distal radius fractures: patterns of articular fragmentation. Orthop Clin North Am 24:239–253
19.
Zurück zum Zitat Dunning CE, Lindsay CS, Bicknell RT, Patterson SD, Johnson JA, King GJ (1999) Supplemental pinning improves the stability of external fixation in distal radius fractures during simulated finger and forearm motion. J Hand Surg 24:992–1000CrossRef Dunning CE, Lindsay CS, Bicknell RT, Patterson SD, Johnson JA, King GJ (1999) Supplemental pinning improves the stability of external fixation in distal radius fractures during simulated finger and forearm motion. J Hand Surg 24:992–1000CrossRef
20.
Zurück zum Zitat Wolfe SW, Austin G, Lorenze M, Swigart CR, Panjabi MM (1999) A biomechanical comparison of different wrist external fixators with and without K-wire augmentation. J Hand Surg 24:516–524CrossRef Wolfe SW, Austin G, Lorenze M, Swigart CR, Panjabi MM (1999) A biomechanical comparison of different wrist external fixators with and without K-wire augmentation. J Hand Surg 24:516–524CrossRef
Metadaten
Titel
Efficiency of fragment specific fixation plates in the treatment of comminuted distal radial fractures
verfasst von
Elhadi Musaab Elhadi Babikir
Eyad Daood Al-Maqdassy
Khalid Hasan
Shamsi Abdul Hameed
Abduljabbar Alhammoud
Mohammed Mubarak Al-Ateeq Al-Dosari
Publikationsdatum
27.06.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 9/2017
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3516-0

Weitere Artikel der Ausgabe 9/2017

International Orthopaedics 9/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.