Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 4/2008

01.04.2008 | Orthopaedic Surgery

Comparison of periprosthetic bone remodelling after implantation of anatomic and straight stem prostheses in total hip arthroplasty

verfasst von: L. F. Grochola, B. Habermann, N. Mastrodomenico, A. Kurth

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 4/2008

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Total hip arthroplasty changes bone loading conditions in the proximal femur and induces adaptive remodelling of the periprosthetic bone. These remodelling processes depend on many implant-specific qualities, e.g. material and elasticity of the stem. The objective of this study was to investigate the effect of the stem design on periprosthetic bone remodelling after insertion of an anatomic stem with proximal fixation and the direct comparison to a straight stem prosthesis.

Materials and methods

In a prospective study, the changes in periprosthetic bone mineral density (BMD) after implantation of 68 CTX-S anatomic and 22 PPF straight stem prostheses were assessed in the first post-operative year by means of DEXA and zone analysis by Gruen (Clin Orthop 141:17–27, 1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening.. Furthermore all patients with CTX-S prostheses were monitored in the second post-operative year. The correlation of adaptive bone remodelling and the systemic bone density was also investigated.

Results

In the distal one-third of the straight stem prosthesis, a clearly greater, although not significant, hypertrophy of the periprosthetic bone was observed. No differences in the extent of bone loss between the two prostheses in the regions of interest (ROI) of the proximal bone were observed. The greatest decrease in BMD was registered in the medial femoral neck in both groups. Bone atrophy decreased progressively as the ROI moved distally, ending in a slight increase in BMD in the distal ROI. No significant changes in periprosthetic BMD occurred in the second post-operative year. A strong positive correlation in the regions with the greatest BMD decrease with the systemic BMD was ascertained.

Conclusion

After implanting a CTX-S prosthesis, as opposed to PPF prostheses, a different pattern of periprosthetic bone remodelling with a slighter hypertrophy of the distal periprosthetic parts was observed. This implies that the extensive proximal, more physiological bone loading of the anatomic stem as well as the removal of less bone while implanting the stem reduces the negative effects of unphysiological strain distribution and stress shielding. The BMD loss in the medial proximal neck cannot be avoided with this stem design either. The lack of significant BMD changes in the second post-operative year suggests that a stabilisation of bone remodelling processes occurs.
Literatur
1.
Zurück zum Zitat Arabmotlagh M, Hennings T, Rittmeister M (2003) Periprothetischer Knochenumbau am proximalen Femur nach Implantation von Individual- und Standard-Hüftendoprothesen. Z Orthop Ihre Grenzgeb 141:519–525PubMedCrossRef Arabmotlagh M, Hennings T, Rittmeister M (2003) Periprothetischer Knochenumbau am proximalen Femur nach Implantation von Individual- und Standard-Hüftendoprothesen. Z Orthop Ihre Grenzgeb 141:519–525PubMedCrossRef
2.
Zurück zum Zitat Bobyn JD, Glassman AH, Goto H, Krygier JJ, Miller JE, Brooks CE (1990) The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty. Clin Orthop 261:196–213PubMed Bobyn JD, Glassman AH, Goto H, Krygier JJ, Miller JE, Brooks CE (1990) The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty. Clin Orthop 261:196–213PubMed
3.
Zurück zum Zitat Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding. Clin Orthop 274:79–96PubMed Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding. Clin Orthop 274:79–96PubMed
4.
Zurück zum Zitat Bohatyrewicz A, Mazurkiewicz H, Dabkowska E, Larysz D, Zietek P, Gusta A (1999) Factors influencing bone mineral density around the femoral stem after cementless total hip arthroplasty. Chir Narzadow Ruchu Ortop Pol 64(4):415–421PubMed Bohatyrewicz A, Mazurkiewicz H, Dabkowska E, Larysz D, Zietek P, Gusta A (1999) Factors influencing bone mineral density around the femoral stem after cementless total hip arthroplasty. Chir Narzadow Ruchu Ortop Pol 64(4):415–421PubMed
5.
Zurück zum Zitat Broos P, Fourneau I (2000) Host factors that affect outcome of total hip arthroplasty. Lancet 355(9214):1479–1480PubMedCrossRef Broos P, Fourneau I (2000) Host factors that affect outcome of total hip arthroplasty. Lancet 355(9214):1479–1480PubMedCrossRef
6.
Zurück zum Zitat Cicciotti MG, Rothman RH, Hozack WJ, Moriarty L (1994) Clinical and roentgenographic evaluation of hydroxyapatite-augmented and nonaugmented porous total hip arthroplasty. J Arthroplasty 9(6):631–639CrossRef Cicciotti MG, Rothman RH, Hozack WJ, Moriarty L (1994) Clinical and roentgenographic evaluation of hydroxyapatite-augmented and nonaugmented porous total hip arthroplasty. J Arthroplasty 9(6):631–639CrossRef
7.
Zurück zum Zitat Engh CA, Bobyn JD (1988) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7–28PubMed Engh CA, Bobyn JD (1988) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7–28PubMed
8.
Zurück zum Zitat Engh CA, McGovern TF, Bobyn JD, Harris WH (1992) A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Joint Surg 74-A:1009–1020 Engh CA, McGovern TF, Bobyn JD, Harris WH (1992) A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Joint Surg 74-A:1009–1020
9.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27PubMed
10.
Zurück zum Zitat Hannan MT, Felson DT, Dawson-Hughes B, Tucker KL Cupples LA, Wilson PWF, Kiel DP (2000) Risk factors for longitudinal bone loss in elderly men and women: Framingham osteoporosis study. J Bone Miner Res 4:710–720CrossRef Hannan MT, Felson DT, Dawson-Hughes B, Tucker KL Cupples LA, Wilson PWF, Kiel DP (2000) Risk factors for longitudinal bone loss in elderly men and women: Framingham osteoporosis study. J Bone Miner Res 4:710–720CrossRef
11.
Zurück zum Zitat Harris WH (1968) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755 Harris WH (1968) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755
12.
Zurück zum Zitat Hennigs T, Arabmotlagh M, Skripitz R, Zichner L (2000) Risikofaktor für periprothetischen Knochenschwund: Perioperative DEXA-Messung der LWS für Planung und Prophylaxe in der Hüftendoprothetik. Osteologie 9(Suppl 1):74 Hennigs T, Arabmotlagh M, Skripitz R, Zichner L (2000) Risikofaktor für periprothetischen Knochenschwund: Perioperative DEXA-Messung der LWS für Planung und Prophylaxe in der Hüftendoprothetik. Osteologie 9(Suppl 1):74
13.
Zurück zum Zitat Hughes SS, Furia JP, Smith P, Pellegrini V (1995) Atrophy of the proximal part of the femur after total hip arthroplasty without cement. J Bone Joint Surg Am 77:231–239PubMed Hughes SS, Furia JP, Smith P, Pellegrini V (1995) Atrophy of the proximal part of the femur after total hip arthroplasty without cement. J Bone Joint Surg Am 77:231–239PubMed
14.
Zurück zum Zitat Jones CD, Laval-Jeantet AM, Laval-Jeantet MH, Genant HK (1987) Importance of measurement of spongious vertebral bone mineral density in the assessment of osteoporosis. Bone 8(4):201–206PubMedCrossRef Jones CD, Laval-Jeantet AM, Laval-Jeantet MH, Genant HK (1987) Importance of measurement of spongious vertebral bone mineral density in the assessment of osteoporosis. Bone 8(4):201–206PubMedCrossRef
15.
Zurück zum Zitat Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW (1993) Dual energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. J Bone Joint Surg Br 75-B:279–287 Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW (1993) Dual energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. J Bone Joint Surg Br 75-B:279–287
16.
Zurück zum Zitat Kiratli BJ, Checovich MM, McBeath AA, Wilson MA, Heiner JP (1996) Measurement of bone mineral density by dual energy X-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem. J Arthroplasty 2:184–193 Kiratli BJ, Checovich MM, McBeath AA, Wilson MA, Heiner JP (1996) Measurement of bone mineral density by dual energy X-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem. J Arthroplasty 2:184–193
17.
Zurück zum Zitat Kusz D, Wojciechowski P, Wojcik K, Kaleta M (1999) Early results of densitometry around cementless stem of Parhofer-Mönch hip endoprosthesis. Chir Narzadow Ruchu Ortop Pol 64(5):497–503PubMed Kusz D, Wojciechowski P, Wojcik K, Kaleta M (1999) Early results of densitometry around cementless stem of Parhofer-Mönch hip endoprosthesis. Chir Narzadow Ruchu Ortop Pol 64(5):497–503PubMed
18.
Zurück zum Zitat Malchau H, Herberts P, Ahnfelt L (1993) Prognosis of total hip replacemet in Sweden. Acta Orthop Scand 64:497–506PubMed Malchau H, Herberts P, Ahnfelt L (1993) Prognosis of total hip replacemet in Sweden. Acta Orthop Scand 64:497–506PubMed
19.
Zurück zum Zitat Marchetti ME, Steinberg GG, Greene JM, Jenis LG, Baran DT (1996) A prospective study of proximal femur bone mass following cemented and uncemented hip artroplasty. J Bone Miner Res 11:1033–1039PubMedCrossRef Marchetti ME, Steinberg GG, Greene JM, Jenis LG, Baran DT (1996) A prospective study of proximal femur bone mass following cemented and uncemented hip artroplasty. J Bone Miner Res 11:1033–1039PubMedCrossRef
20.
Zurück zum Zitat Martini F, Lebherz C, Mayer F, Leichtle U, Kremling E, Sell S (2000) Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem. J Bone Joint Surg Br 82:1065–1071PubMedCrossRef Martini F, Lebherz C, Mayer F, Leichtle U, Kremling E, Sell S (2000) Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem. J Bone Joint Surg Br 82:1065–1071PubMedCrossRef
21.
Zurück zum Zitat McCarthy CK, Steinberg GG, Agren M, Leahey D, Baran DT (1991) Quantyfying bone loss from the proximal femur after total hip arthroplasty. J Bone Joint Surg Br 73:774–778PubMed McCarthy CK, Steinberg GG, Agren M, Leahey D, Baran DT (1991) Quantyfying bone loss from the proximal femur after total hip arthroplasty. J Bone Joint Surg Br 73:774–778PubMed
22.
Zurück zum Zitat Nakamura K (1996) Measurement of periprosthetic bone mineral density after cementless hip arthroplasty by dual energy X-ray absorptiometry: longitudinal and cross-sectional evaluation. J Orthop Sci 1:113–122CrossRef Nakamura K (1996) Measurement of periprosthetic bone mineral density after cementless hip arthroplasty by dual energy X-ray absorptiometry: longitudinal and cross-sectional evaluation. J Orthop Sci 1:113–122CrossRef
23.
Zurück zum Zitat Nevitt MC, Lane NE, Scott JS, Hochberg MC, Pressmann AR, Genant HK, Cummings SR (1995) Radiographic osteoarthritis of the hip and bone mineral density. Arthritis Rheum 38:907–916PubMedCrossRef Nevitt MC, Lane NE, Scott JS, Hochberg MC, Pressmann AR, Genant HK, Cummings SR (1995) Radiographic osteoarthritis of the hip and bone mineral density. Arthritis Rheum 38:907–916PubMedCrossRef
24.
Zurück zum Zitat Niinimaki T, Jalovaara P (1995) Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. Acta Orthop Scand 66(4):347–351PubMedCrossRef Niinimaki T, Jalovaara P (1995) Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. Acta Orthop Scand 66(4):347–351PubMedCrossRef
25.
Zurück zum Zitat Niinimaki T, Junila J, Jalovaara P (2001) A proximal fixed anatomic femoral stem reduces stress shielding. Int Orthop 25(2):85–88PubMedCrossRef Niinimaki T, Junila J, Jalovaara P (2001) A proximal fixed anatomic femoral stem reduces stress shielding. Int Orthop 25(2):85–88PubMedCrossRef
26.
Zurück zum Zitat Nishii T, Sugano N, Masuhara K, Shibuya T, Ochi T, Tamura S (1997) Longitudinal evaluation of time related bone remodeling after cementless total hip arthroplasty. Clin Ortop 339:121–131CrossRef Nishii T, Sugano N, Masuhara K, Shibuya T, Ochi T, Tamura S (1997) Longitudinal evaluation of time related bone remodeling after cementless total hip arthroplasty. Clin Ortop 339:121–131CrossRef
27.
Zurück zum Zitat Ochsner PE (2002) Die Hüfttotalprothese. Springer, Berlin Ochsner PE (2002) Die Hüfttotalprothese. Springer, Berlin
28.
Zurück zum Zitat Okano T, Hagino H, Otsuka T, Teshima R, Yamamoto K, Hirano Y, Nakamura K (2002) Measurement of periprosthetic bone mineral density by dual energy X-ray absorptiometry is useful for estimating fixation between the bone and the prosthesis in an early stage. J Arthroplasty 17(1):49–55PubMedCrossRef Okano T, Hagino H, Otsuka T, Teshima R, Yamamoto K, Hirano Y, Nakamura K (2002) Measurement of periprosthetic bone mineral density by dual energy X-ray absorptiometry is useful for estimating fixation between the bone and the prosthesis in an early stage. J Arthroplasty 17(1):49–55PubMedCrossRef
29.
Zurück zum Zitat Park YS, Lee JL, Yun SH, Jung MW, Oh I (2003) Comparison of hydroxyapatite- and porous-coated stems in total hip replacement. Acta Orthop Scand 74(3):259–263PubMedCrossRef Park YS, Lee JL, Yun SH, Jung MW, Oh I (2003) Comparison of hydroxyapatite- and porous-coated stems in total hip replacement. Acta Orthop Scand 74(3):259–263PubMedCrossRef
30.
Zurück zum Zitat Petersen MB, Kolthoff N, Eiken P (1995) Bone mineral density around femoral stems. Acta Orthop Scand 66(5):432–434PubMed Petersen MB, Kolthoff N, Eiken P (1995) Bone mineral density around femoral stems. Acta Orthop Scand 66(5):432–434PubMed
31.
Zurück zum Zitat Pritchett JW (1995) Femoral bone loss following hip replacement. Clin Orthop Relat Res 314:156–161PubMed Pritchett JW (1995) Femoral bone loss following hip replacement. Clin Orthop Relat Res 314:156–161PubMed
32.
Zurück zum Zitat Starker M, Thümler P, Weipert A, Hanusek S (2000) Computergestützte Prothesenauswahl und Implantationskontrolle. Orthopäde Springer 29:627–635 Starker M, Thümler P, Weipert A, Hanusek S (2000) Computergestützte Prothesenauswahl und Implantationskontrolle. Orthopäde Springer 29:627–635
33.
Zurück zum Zitat Sychterz CJ, Engh CA (1996) The influence of clinical factors on periprosthetic bone remodelling. Clin Orthop 322:285–292PubMed Sychterz CJ, Engh CA (1996) The influence of clinical factors on periprosthetic bone remodelling. Clin Orthop 322:285–292PubMed
34.
Zurück zum Zitat Venesmaa PK, Kroger HP, Jurvelin JS, Miettinen HJ, Suomaliainen OT, Alhava EM (2001) Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual energy X-ray absorptiometry—a 3-year follow-up study. J Bone Miner Res 16(6):1056–1061PubMedCrossRef Venesmaa PK, Kroger HP, Jurvelin JS, Miettinen HJ, Suomaliainen OT, Alhava EM (2001) Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual energy X-ray absorptiometry—a 3-year follow-up study. J Bone Miner Res 16(6):1056–1061PubMedCrossRef
35.
Zurück zum Zitat Venesmaa PK, Kroger HP, Jurvelin JS, Miettinen HJ, Suomaliainen OT, Alhava EM (2003) Periprosthetic bone loss after cemented total hip arthroplasty. Acta Orthop Scand 74(1):31–36PubMedCrossRef Venesmaa PK, Kroger HP, Jurvelin JS, Miettinen HJ, Suomaliainen OT, Alhava EM (2003) Periprosthetic bone loss after cemented total hip arthroplasty. Acta Orthop Scand 74(1):31–36PubMedCrossRef
36.
Zurück zum Zitat Yamaguchi K, Masuhara K, Ohzono K, Sugano N, Nishii T, Ochi T (2000) Evaluation of periprosthetic bone-remodelling after cementless total hip arthroplasty. J Bone Joint Surg 82-A(10):1426–1431PubMed Yamaguchi K, Masuhara K, Ohzono K, Sugano N, Nishii T, Ochi T (2000) Evaluation of periprosthetic bone-remodelling after cementless total hip arthroplasty. J Bone Joint Surg 82-A(10):1426–1431PubMed
Metadaten
Titel
Comparison of periprosthetic bone remodelling after implantation of anatomic and straight stem prostheses in total hip arthroplasty
verfasst von
L. F. Grochola
B. Habermann
N. Mastrodomenico
A. Kurth
Publikationsdatum
01.04.2008
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 4/2008
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-007-0507-4

Weitere Artikel der Ausgabe 4/2008

Archives of Orthopaedic and Trauma Surgery 4/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.