Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 4/2017

04.03.2017 | Handsurgery

Validity of computed tomography in predicting scaphoid screw prominence: a cadaveric study

verfasst von: Clare E. Griffis, Cara Olsen, Leon Nesti, C. Frank Gould, Michael Frew, Patricia McKay

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

Studies of hardware protrusion into joint spaces following fracture fixation have been performed to address whether or not there is discrepancy between the actual and radiographic appearance of screw prominence. The purpose of our study was to prove that, with respect to the scaphoid, prominence as visualized on CT scan is real and not a result of metal artifact.

Methods

Forty-two cadaveric wrists were separated into four allotted groups with 21 control specimens and 21 study specimens. All specimens were radiographically screened to exclude those with inherent carpal abnormalities. Acutrak® headless compression screws were placed into all specimens using an open dorsal approach. Cartilage was removed from screw insertion site at the convex surface of the scaphoid proximal pole. Control specimens had 0 mm screw head prominence. The studied specimens had 1, 2, and 3 mm head prominence measured with a digital caliper. Computed tomography, with direct sagittal acquisition and metal suppression technique, was then performed on all specimens following screw placement. Two staff radiologists blinded to the study groups interpreted the images.

Results

Results revealed that only one of 21 control specimens was interpreted as prominent. Comparatively, in the studied groups, 90% were accurately interpreted as prominent.

Conclusions

CT provides an accurate assessment of scaphoid screw head prominence. When a screw appears prominent on CT scan, it is likely to be truly prominent without contribution from metallic artifact.
Literatur
1.
Zurück zum Zitat Neshkova IS, Jakubietz RG, Kuk D, Jakubietz MG, Meffert RH, Schmidt K (2015) Percutaneous screw fixation of non- or minimally displaced scaphoid fractures. Oper Orthop Traumatol 27(5):448–454CrossRefPubMed Neshkova IS, Jakubietz RG, Kuk D, Jakubietz MG, Meffert RH, Schmidt K (2015) Percutaneous screw fixation of non- or minimally displaced scaphoid fractures. Oper Orthop Traumatol 27(5):448–454CrossRefPubMed
2.
Zurück zum Zitat Hannemann PF, Brouwers L, Dullaert K, van der Linden ES, Poeze M, Brink PR (2015) Determining scaphoid waist fracture union by conventional radiographic examination: an analysis of reliability and validity. Arch Orthop Trauma Surg 135(2):291–296CrossRefPubMed Hannemann PF, Brouwers L, Dullaert K, van der Linden ES, Poeze M, Brink PR (2015) Determining scaphoid waist fracture union by conventional radiographic examination: an analysis of reliability and validity. Arch Orthop Trauma Surg 135(2):291–296CrossRefPubMed
3.
Zurück zum Zitat Mallee WH, Mellema JJ, Guitton TG, Goslings JC, Ring D, Doornberg JN (2016) 6-week radiographs unsuitable for diagnosis of suspected scaphoid fractures. Arch Orthop Trauma Surg 136(6):771–778CrossRefPubMedPubMedCentral Mallee WH, Mellema JJ, Guitton TG, Goslings JC, Ring D, Doornberg JN (2016) 6-week radiographs unsuitable for diagnosis of suspected scaphoid fractures. Arch Orthop Trauma Surg 136(6):771–778CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Link TM, Berning W, Scherf S, Joosten U, Joist A, Engelke K, Daldrup-Link HE (2000) CT of metal implants: reduction of artifacts using an extended CT scale technique. J Comput Assist Tomogr 24(1):165–172CrossRefPubMed Link TM, Berning W, Scherf S, Joosten U, Joist A, Engelke K, Daldrup-Link HE (2000) CT of metal implants: reduction of artifacts using an extended CT scale technique. J Comput Assist Tomogr 24(1):165–172CrossRefPubMed
5.
Zurück zum Zitat Fayad LM, Patra A, Fishman EK (2009) Value of 3D CT in defining skeletal complications of orthopedic hardware in the postoperative patient. AJR 193:1155–1163CrossRefPubMed Fayad LM, Patra A, Fishman EK (2009) Value of 3D CT in defining skeletal complications of orthopedic hardware in the postoperative patient. AJR 193:1155–1163CrossRefPubMed
6.
Zurück zum Zitat Thomas AD, Greenberg JA (2009) Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study. J Hand Surg Am 34A:258–261CrossRef Thomas AD, Greenberg JA (2009) Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study. J Hand Surg Am 34A:258–261CrossRef
7.
Zurück zum Zitat Femino JE, Gruber BF, Karunakar MA (2007) Safe zone for the placement of medial malleolar screws. J Bone Jt Surg AM 89 A(1):133–138 Femino JE, Gruber BF, Karunakar MA (2007) Safe zone for the placement of medial malleolar screws. J Bone Jt Surg AM 89 A(1):133–138
8.
Zurück zum Zitat Hulleberg G, Finsen V (1990) Removal of osteosynthesis material from healed hip fractures. Ann Chir Gynaecol 79:161–164PubMed Hulleberg G, Finsen V (1990) Removal of osteosynthesis material from healed hip fractures. Ann Chir Gynaecol 79:161–164PubMed
9.
Zurück zum Zitat Hindman BW, Kulik WJ, Lee G, Avolio RE (1989) Occult fractures of the carpals and metacarpals: demonstration by CT. AJR 153:529–532CrossRefPubMed Hindman BW, Kulik WJ, Lee G, Avolio RE (1989) Occult fractures of the carpals and metacarpals: demonstration by CT. AJR 153:529–532CrossRefPubMed
10.
Zurück zum Zitat Fleiss J (1986) The design and analysis of clinical experiments. Wiley, New York Fleiss J (1986) The design and analysis of clinical experiments. Wiley, New York
11.
Zurück zum Zitat Elliot MJ, Slakey JB (2014) CT provides precise size assessment of implanted titanium alloy pedicle screws. Clin Orthop Relat Res 472(5):1605–1609CrossRef Elliot MJ, Slakey JB (2014) CT provides precise size assessment of implanted titanium alloy pedicle screws. Clin Orthop Relat Res 472(5):1605–1609CrossRef
12.
Zurück zum Zitat Compson JP, Waterman JK, Heatley FW (1997) The radiological anatomy of the scaphoid: Part 2: radiology. JHS 22B 1:8–15 Compson JP, Waterman JK, Heatley FW (1997) The radiological anatomy of the scaphoid: Part 2: radiology. JHS 22B 1:8–15
Metadaten
Titel
Validity of computed tomography in predicting scaphoid screw prominence: a cadaveric study
verfasst von
Clare E. Griffis
Cara Olsen
Leon Nesti
C. Frank Gould
Michael Frew
Patricia McKay
Publikationsdatum
04.03.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 4/2017
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-017-2658-2

Weitere Artikel der Ausgabe 4/2017

Archives of Orthopaedic and Trauma Surgery 4/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.