Skip to main content
Erschienen in: European Spine Journal 11/2010

01.11.2010 | Original Article

Placement of pedicle screws using three-dimensional fluoroscopy-based navigation in lumbar vertebrae with axial rotation

verfasst von: Wei Tian, Zhao Lang

Erschienen in: European Spine Journal | Ausgabe 11/2010

Einloggen, um Zugang zu erhalten

Abstract

Despite potential advantages of three-dimensional fluoroscopy-based navigation, there still remain a lot of controversies about the indications of this technology, especially whether it is worthy of being used in placement of pedicle screws in lumbar spine. However, according to the inconsistent conclusions reported in the literature and our experiences, the traditional method relying on anatomical landmarks and fluoroscopic views to guide lumbar pedicle screw insertion is unable to meet the requirement of precise screw placement. Based on our observation, screw malposition seems to occur concomitant with vertebral axial rotation which is a ubiquitous phenomenon. Three-dimensional fluoroscopy-based navigation can provide the most valuable axial images in real-time, so it may be useful for placement of pedicle screws in lumbar spine. This study was intended to evaluate the effect of axial rotation of lumbar vertebrae on the accuracy of pedicle screw placement using the traditional method, as well as assess the value of three-dimensional fluoroscopy-based navigation in improving the accuracy. Sixteen lumbar simulation models at different degrees of axial rotation (0°, 5°, 10°, and 20°), with every four assigned the same degree, were equally divided into two groups (traditional method group and three-dimensional fluoroscopy-based navigation group). Random placement of pedicle screws was carried out, followed by CT scan postoperatively. Then the outer pedicle cortex contours were depicted from reconstructed sectional pedicle images using Photoshop. The accuracy of pedicle screw placement was evaluated by determining the interrelationship between screw trajectory and pedicle cortex (quality), and measuring the shortest distance from pedicle screw axis to outer cortex of the pedicle (quantity). Eighty pedicle screws were implanted, respectively, in each group. In traditional method group, statistical difference existed in the accuracy of pedicle screw placement at different axial rotational degrees (P < 0.05). With degrees increasing, the accuracy declined. The accuracy of three-dimensional fluoroscopy-based navigation group was higher than traditional method group in vertebrae with axial rotation (P < 0.01). In qualitative evaluation, the accuracy of the two methods had statistical difference when the degree was 20°, and in quantitative evaluation, statistical difference existed in 5°, 10°, and 20° of vertebral axial rotation.
Literatur
1.
Zurück zum Zitat Amiot LP, Labelle H, DeGuise JA et al (1995) Computer-assisted pedicle screw fixation. A feasibility study. Spine 20(10):1208–1212CrossRefPubMed Amiot LP, Labelle H, DeGuise JA et al (1995) Computer-assisted pedicle screw fixation. A feasibility study. Spine 20(10):1208–1212CrossRefPubMed
2.
Zurück zum Zitat Roy-Camille R, Saillant G, Berteaux D, Marie-Anne S, Mamoudy P (1979) Vertebral osteosynthesis using metal plates. Its different uses. Chirurgie 105:579–603 (in French) Roy-Camille R, Saillant G, Berteaux D, Marie-Anne S, Mamoudy P (1979) Vertebral osteosynthesis using metal plates. Its different uses. Chirurgie 105:579–603 (in French)
3.
Zurück zum Zitat Suk S, Lee C, Min H et al (1994) Comparison of Cotrel Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis. Int Orthop 18:341–346CrossRefPubMed Suk S, Lee C, Min H et al (1994) Comparison of Cotrel Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis. Int Orthop 18:341–346CrossRefPubMed
4.
Zurück zum Zitat Gaines RW (2000) The use of pedicle screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82:1458–1476PubMed Gaines RW (2000) The use of pedicle screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82:1458–1476PubMed
5.
Zurück zum Zitat O’Brien MF, Lenke LG, Mardjetko S et al (2000) Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique? Spine 25:2285–2293CrossRefPubMed O’Brien MF, Lenke LG, Mardjetko S et al (2000) Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique? Spine 25:2285–2293CrossRefPubMed
6.
Zurück zum Zitat Belmont PJ, Klemme WR, Dhawan A et al (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346CrossRefPubMed Belmont PJ, Klemme WR, Dhawan A et al (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346CrossRefPubMed
7.
Zurück zum Zitat Suk S, Kim WJ, Lee SM et al (2001) Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine 26:2049–2057CrossRefPubMed Suk S, Kim WJ, Lee SM et al (2001) Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine 26:2049–2057CrossRefPubMed
8.
Zurück zum Zitat Vaccaro A, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed Vaccaro A, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed
9.
Zurück zum Zitat Vaccaro A, Rizzolo SJ, Balderston RA et al (1995) Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed Vaccaro A, Rizzolo SJ, Balderston RA et al (1995) Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed
10.
Zurück zum Zitat Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop 203:7–17PubMed Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop 203:7–17PubMed
11.
Zurück zum Zitat Acikbas SC, Arslan FY, Tuncer MR (2003) The effect of transpedicular screw misplacement on late spinal stability. Acta Neurochir (Wien) 145:949–955CrossRef Acikbas SC, Arslan FY, Tuncer MR (2003) The effect of transpedicular screw misplacement on late spinal stability. Acta Neurochir (Wien) 145:949–955CrossRef
12.
Zurück zum Zitat Lonstein JE, Denis F, Jhperra JE et al (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81(11):1519–1528PubMed Lonstein JE, Denis F, Jhperra JE et al (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81(11):1519–1528PubMed
13.
Zurück zum Zitat Hott JS, Deshmukh VR, Klopfenstein JD et al (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 54(5):1131–1136CrossRefPubMed Hott JS, Deshmukh VR, Klopfenstein JD et al (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 54(5):1131–1136CrossRefPubMed
14.
Zurück zum Zitat Hott JS, Papadopoulos SM, Theodore N et al (2004) Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine 29(24):2856–2860CrossRefPubMed Hott JS, Papadopoulos SM, Theodore N et al (2004) Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine 29(24):2856–2860CrossRefPubMed
15.
Zurück zum Zitat Rajasekaran S, Vidyadhara S, Ramesh P et al (2007) Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine 32(2):E56–E64CrossRefPubMed Rajasekaran S, Vidyadhara S, Ramesh P et al (2007) Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine 32(2):E56–E64CrossRefPubMed
16.
Zurück zum Zitat Villavicencio AT, Burneikiene S, Bulsara KR et al (2005) Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques. J Spinal Disord Tech 18(4):369–375CrossRefPubMed Villavicencio AT, Burneikiene S, Bulsara KR et al (2005) Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques. J Spinal Disord Tech 18(4):369–375CrossRefPubMed
17.
Zurück zum Zitat Karapinar L, Erel N, Ozturk H (2008) Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? J Spinal Disord Tech 21(1):63–67CrossRefPubMed Karapinar L, Erel N, Ozturk H (2008) Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? J Spinal Disord Tech 21(1):63–67CrossRefPubMed
18.
Zurück zum Zitat Castro WH, Halm H, Jerosch J et al (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324CrossRefPubMed Castro WH, Halm H, Jerosch J et al (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324CrossRefPubMed
19.
Zurück zum Zitat Jerosch J, Malms J, Castro WH et al (1992) Accuracy of pedicle screws following instrumented dorsal fusion of the lumbar spine. Z Orthop Ihre Grenzgeb 130(6):479–483 (in German)CrossRefPubMed Jerosch J, Malms J, Castro WH et al (1992) Accuracy of pedicle screws following instrumented dorsal fusion of the lumbar spine. Z Orthop Ihre Grenzgeb 130(6):479–483 (in German)CrossRefPubMed
20.
Zurück zum Zitat Kosmopoulos V (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32(3):E111–E120CrossRefPubMed Kosmopoulos V (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32(3):E111–E120CrossRefPubMed
21.
Zurück zum Zitat Soyuncu Y, Yildiırim FB, Sekban H et al (2005) Anatomic evaluation and relationship between the lumbar pedicle and adjacent neural structures: an anatomic study. J Spinal Disord Tech 18:243–246PubMed Soyuncu Y, Yildiırim FB, Sekban H et al (2005) Anatomic evaluation and relationship between the lumbar pedicle and adjacent neural structures: an anatomic study. J Spinal Disord Tech 18:243–246PubMed
22.
Zurück zum Zitat Hecquet J, Legaye J, Duval-Beaupère G (1998) Access to a three-dimensional measure of vertebral axial rotation. Eur Spine J 7:206–211CrossRefPubMed Hecquet J, Legaye J, Duval-Beaupère G (1998) Access to a three-dimensional measure of vertebral axial rotation. Eur Spine J 7:206–211CrossRefPubMed
23.
Zurück zum Zitat Weinstein JN, Spratt KF, Spengler D et al (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018CrossRefPubMed Weinstein JN, Spratt KF, Spengler D et al (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018CrossRefPubMed
24.
Zurück zum Zitat Kouwenhoven JM, Vincken KL, Bartels LW, Castelein RM (2006) Analysis of preexistent vertebral rotation in the normal spine. Spine 31(13):1467–1472CrossRefPubMed Kouwenhoven JM, Vincken KL, Bartels LW, Castelein RM (2006) Analysis of preexistent vertebral rotation in the normal spine. Spine 31(13):1467–1472CrossRefPubMed
Metadaten
Titel
Placement of pedicle screws using three-dimensional fluoroscopy-based navigation in lumbar vertebrae with axial rotation
verfasst von
Wei Tian
Zhao Lang
Publikationsdatum
01.11.2010
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 11/2010
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-010-1564-x

Weitere Artikel der Ausgabe 11/2010

European Spine Journal 11/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.