Skip to main content
Erschienen in: European Spine Journal 6/2011

01.06.2011 | Ideas and Technical Innovations

Percutaneous instrumentation of the cervical and cervico-thoracic spine using pedicle screws: preliminary clinical results and analysis of accuracy

verfasst von: Christian Schaefer, Phillip Begemann, Ina Fuhrhop, Malte Schroeder, Lennart Viezens, Lothar Wiesner, Nils Hansen-Algenstaedt

Erschienen in: European Spine Journal | Ausgabe 6/2011

Einloggen, um Zugang zu erhalten

Abstract

The pedicle screw instrumentation represents the most rigid construct of the cervical and cervicothoracic spine and in spite of the risks to neurovascular structures clinical relevant complications do not occur frequently. The steep angles of the cervical pedicles result in a wide surgical exposure with extensive muscular trauma. The objective of this study was the evaluation of the accuracy of cervical pedicle screw insertion through a minimally invasive technique to reduce access-related muscular trauma. Therefore, percutaneous transpedicular instrumentation of the cervical and cervicothoracic spine was performed in 15 patients using fluoroscopy. All instrumentations from C2 to Th4 were inserted bilaterally through 2 to 3-cm skin and fascia incisions even in multilevel procedures and the rods were placed by blunt insertion through the incision. Thin-cut CT scan was used postoperatively to analyze pedicle violations. 76.4% of 72 screws were placed accurately. Most pedicle perforations were seen laterally towards the vertebral artery. Critical breaches >2 mm or narrowing of the transversal foramen occurred in 12.5% of screws; however, no revision surgery for screw displacement was needed in the absence of clinical symptoms. No conversion from percutaneous to open surgery was necessary. It was concluded that percutaneous transpedicular instrumentation of the cervical spine is a surgically demanding technique and should be reserved for experienced spine surgeons. The indications are limited to instrumentation-only procedures or in combination with anterior treatment, but with the potential to minimize access-related morbidity.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Abumi K, Kaneda K (1997) Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22:1853–1863PubMedCrossRef Abumi K, Kaneda K (1997) Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22:1853–1863PubMedCrossRef
2.
Zurück zum Zitat Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25:962–969PubMedCrossRef Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25:962–969PubMedCrossRef
3.
Zurück zum Zitat Bartels E (2006) Dissection of the extracranial vertebral artery: clinical findings and early noninvasive diagnosis in 24 patients. J Neuroimaging 16:24–33PubMedCrossRef Bartels E (2006) Dissection of the extracranial vertebral artery: clinical findings and early noninvasive diagnosis in 24 patients. J Neuroimaging 16:24–33PubMedCrossRef
4.
Zurück zum Zitat Bartels E, Flugel KA (1996) Evaluation of extracranial vertebral artery dissection with duplex color-flow imaging. Stroke 27:290–295PubMed Bartels E, Flugel KA (1996) Evaluation of extracranial vertebral artery dissection with duplex color-flow imaging. Stroke 27:290–295PubMed
5.
Zurück zum Zitat Fong S, Duplessis S (2005) Minimally invasive lateral mass plating in the treatment of posterior cervical trauma: surgical technique. J Spinal Disord Tech 18:224–228PubMedCrossRef Fong S, Duplessis S (2005) Minimally invasive lateral mass plating in the treatment of posterior cervical trauma: surgical technique. J Spinal Disord Tech 18:224–228PubMedCrossRef
6.
Zurück zum Zitat Hasegawa K, Hirano T, Shimoda H, Homma T, Morita O (2008) Indications for cervical pedicle screw instrumentation in nontraumatic lesions. Spine (Phila Pa 1976) 33:2284–2289CrossRef Hasegawa K, Hirano T, Shimoda H, Homma T, Morita O (2008) Indications for cervical pedicle screw instrumentation in nontraumatic lesions. Spine (Phila Pa 1976) 33:2284–2289CrossRef
7.
Zurück zum Zitat Heller JG, Silcox DH 3rd, Sutterlin CE 3rd (1995) Complications of posterior cervical plating. Spine 20:2442–2448PubMedCrossRef Heller JG, Silcox DH 3rd, Sutterlin CE 3rd (1995) Complications of posterior cervical plating. Spine 20:2442–2448PubMedCrossRef
8.
Zurück zum Zitat Holly LT, Foley KT (2006) Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine 31:536–540; discussion 541 Holly LT, Foley KT (2006) Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine 31:536–540; discussion 541
9.
Zurück zum Zitat Hott JS, Papadopoulos SM, Theodore N, Dickman CA, Sonntag VK (2004) Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine 29:2856–2860PubMedCrossRef Hott JS, Papadopoulos SM, Theodore N, Dickman CA, Sonntag VK (2004) Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine 29:2856–2860PubMedCrossRef
10.
Zurück zum Zitat Isaacs RE, Podichetty VK, Santiago P, Sandhu FA, Spears J, Kelly K, Rice L, Fessler RG (2005) Minimally invasive microendoscopy-assisted transforaminal lumbar interbody fusion with instrumentation. J Neurosurg 3:98–105 Isaacs RE, Podichetty VK, Santiago P, Sandhu FA, Spears J, Kelly K, Rice L, Fessler RG (2005) Minimally invasive microendoscopy-assisted transforaminal lumbar interbody fusion with instrumentation. J Neurosurg 3:98–105
11.
Zurück zum Zitat Ito Y, Sugimoto Y, Tomioka M, Hasegawa Y, Nakago K, Yagata Y (2008) Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion. J Neurosurg 9:450–453 Ito Y, Sugimoto Y, Tomioka M, Hasegawa Y, Nakago K, Yagata Y (2008) Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion. J Neurosurg 9:450–453
12.
Zurück zum Zitat Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7:222–229PubMedCrossRef Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7:222–229PubMedCrossRef
13.
Zurück zum Zitat Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine 22:977–982PubMedCrossRef Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine 22:977–982PubMedCrossRef
14.
Zurück zum Zitat Karaikovic EE, Daubs MD, Madsen RW, Gaines RW Jr (1997) Morphologic characteristics of human cervical pedicles. Spine (Phila Pa 1976) 22:493–500CrossRef Karaikovic EE, Daubs MD, Madsen RW, Gaines RW Jr (1997) Morphologic characteristics of human cervical pedicles. Spine (Phila Pa 1976) 22:493–500CrossRef
15.
Zurück zum Zitat Kast E, Mohr K, Richter HP, Borm W (2006) Complications of transpedicular screw fixation in the cervical spine. Eur Spine J 15:327–334PubMedCrossRef Kast E, Mohr K, Richter HP, Borm W (2006) Complications of transpedicular screw fixation in the cervical spine. Eur Spine J 15:327–334PubMedCrossRef
16.
Zurück zum Zitat Kim DY, Lee SH, Chung SK, Lee HY (2005) Comparison of multifidus muscle atrophy and trunk extension muscle strength: percutaneous versus open pedicle screw fixation. Spine 30:123–129PubMedCrossRef Kim DY, Lee SH, Chung SK, Lee HY (2005) Comparison of multifidus muscle atrophy and trunk extension muscle strength: percutaneous versus open pedicle screw fixation. Spine 30:123–129PubMedCrossRef
17.
Zurück zum Zitat Kim HS, Heller JG, Hudgins PA, Fountain JA (2003) The accuracy of computed tomography in assessing cervical pedicle screw placement. Spine 28:2441–2446PubMedCrossRef Kim HS, Heller JG, Hudgins PA, Fountain JA (2003) The accuracy of computed tomography in assessing cervical pedicle screw placement. Spine 28:2441–2446PubMedCrossRef
18.
Zurück zum Zitat Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257–263PubMed Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257–263PubMed
19.
Zurück zum Zitat Kotani Y, Cunningham BW, Abumi K, McAfee PC (1994) Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine. Spine 19:2529–2539PubMedCrossRef Kotani Y, Cunningham BW, Abumi K, McAfee PC (1994) Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine. Spine 19:2529–2539PubMedCrossRef
20.
Zurück zum Zitat Kothe R, Ruther W, Schneider E, Linke B (2004) Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine (Phila Pa 1976) 29:1869–1875CrossRef Kothe R, Ruther W, Schneider E, Linke B (2004) Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine (Phila Pa 1976) 29:1869–1875CrossRef
21.
Zurück zum Zitat Lee SH, Choi WG, Lim SR, Kang HY, Shin SW (2004) Minimally invasive anterior lumbar interbody fusion followed by percutaneous pedicle screw fixation for isthmic spondylolisthesis. Spine J 4:644–649PubMedCrossRef Lee SH, Choi WG, Lim SR, Kang HY, Shin SW (2004) Minimally invasive anterior lumbar interbody fusion followed by percutaneous pedicle screw fixation for isthmic spondylolisthesis. Spine J 4:644–649PubMedCrossRef
22.
Zurück zum Zitat Lowery GL, Kulkarni SS (2000) Posterior percutaneous spine instrumentation. Eur Spine J 9 Suppl 1:S126–130 Lowery GL, Kulkarni SS (2000) Posterior percutaneous spine instrumentation. Eur Spine J 9 Suppl 1:S126–130
23.
Zurück zum Zitat Neo M, Sakamoto T, Fujibayashi S, Nakamura T (2005) The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine (Phila Pa 1976) 30:2800–2805CrossRef Neo M, Sakamoto T, Fujibayashi S, Nakamura T (2005) The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine (Phila Pa 1976) 30:2800–2805CrossRef
24.
Zurück zum Zitat Oda I, Abumi K, Ito M, Kotani Y, Oya T, Hasegawa K, Minami A (2006) Palliative spinal reconstruction using cervical pedicle screws for metastatic lesions of the spine: a retrospective analysis of 32 cases. Spine (Phila Pa 1976) 31:1439–1444CrossRef Oda I, Abumi K, Ito M, Kotani Y, Oya T, Hasegawa K, Minami A (2006) Palliative spinal reconstruction using cervical pedicle screws for metastatic lesions of the spine: a retrospective analysis of 32 cases. Spine (Phila Pa 1976) 31:1439–1444CrossRef
25.
Zurück zum Zitat Pateder DB, Carbone JJ (2006) Lateral mass screw fixation for cervical spine trauma: associated complications and efficacy in maintaining alignment. Spine J 6:40–43PubMedCrossRef Pateder DB, Carbone JJ (2006) Lateral mass screw fixation for cervical spine trauma: associated complications and efficacy in maintaining alignment. Spine J 6:40–43PubMedCrossRef
26.
Zurück zum Zitat Rath SA, Moszko S, Schaffner PM, Cantone G, Braun V, Richter HP, Antoniadis G (2008) Accuracy of pedicle screw insertion in the cervical spine for internal fixation using frameless stereotactic guidance. J Neurosurg 8:237–245 Rath SA, Moszko S, Schaffner PM, Cantone G, Braun V, Richter HP, Antoniadis G (2008) Accuracy of pedicle screw insertion in the cervical spine for internal fixation using frameless stereotactic guidance. J Neurosurg 8:237–245
27.
Zurück zum Zitat Reinhold M, Bach C, Audige L, Bale R, Attal R, Blauth M, Magerl F (2008) Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature. Eur Spine J 17:564–575PubMedCrossRef Reinhold M, Bach C, Audige L, Bale R, Attal R, Blauth M, Magerl F (2008) Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature. Eur Spine J 17:564–575PubMedCrossRef
28.
Zurück zum Zitat Reinhold M, Magerl F, Rieger M, Blauth M (2007) Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data. Eur Spine J 16:47–56PubMedCrossRef Reinhold M, Magerl F, Rieger M, Blauth M (2007) Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data. Eur Spine J 16:47–56PubMedCrossRef
29.
Zurück zum Zitat Richter M, Cakir B, Schmidt R (2005) Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine 30:2280–2287PubMedCrossRef Richter M, Cakir B, Schmidt R (2005) Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine 30:2280–2287PubMedCrossRef
30.
Zurück zum Zitat Richter M, Wilke HJ, Kluger P, Neller S, Claes L, Puhl W (2000) Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in vitro comparison with two established implant systems. Eur Spine J 9:417–425PubMedCrossRef Richter M, Wilke HJ, Kluger P, Neller S, Claes L, Puhl W (2000) Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in vitro comparison with two established implant systems. Eur Spine J 9:417–425PubMedCrossRef
31.
Zurück zum Zitat Sakamoto T, Neo M, Nakamura T (2004) Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine (Phila Pa 1976) 29:2510–2514; discussion 2515 Sakamoto T, Neo M, Nakamura T (2004) Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine (Phila Pa 1976) 29:2510–2514; discussion 2515
32.
Zurück zum Zitat Sanelli PC, Tong S, Gonzalez RG, Eskey CJ (2002) Normal variation of vertebral artery on CT angiography and its implications for diagnosis of acquired pathology. J Comput Assist Tomogr 26:462–470PubMedCrossRef Sanelli PC, Tong S, Gonzalez RG, Eskey CJ (2002) Normal variation of vertebral artery on CT angiography and its implications for diagnosis of acquired pathology. J Comput Assist Tomogr 26:462–470PubMedCrossRef
33.
Zurück zum Zitat Scheufler KM, Kirsch E (2007) Percutaneous multilevel decompressive laminectomy, foraminotomy, and instrumented fusion for cervical spondylotic radiculopathy and myelopathy: assessment of feasibility and surgical technique. J Neurosurg 7:514–520 Scheufler KM, Kirsch E (2007) Percutaneous multilevel decompressive laminectomy, foraminotomy, and instrumented fusion for cervical spondylotic radiculopathy and myelopathy: assessment of feasibility and surgical technique. J Neurosurg 7:514–520
34.
Zurück zum Zitat Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9(Suppl 1):S57–S64 Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9(Suppl 1):S57–S64
35.
Zurück zum Zitat Schmidt R, Wilke HJ, Claes L, Puhl W, Richter M (2003) Pedicle screws enhance primary stability in multilevel cervical corpectomies: biomechanical in vitro comparison of different implants including constrained and nonconstrained posterior instrumentations. Spine 28:1821–1828PubMedCrossRef Schmidt R, Wilke HJ, Claes L, Puhl W, Richter M (2003) Pedicle screws enhance primary stability in multilevel cervical corpectomies: biomechanical in vitro comparison of different implants including constrained and nonconstrained posterior instrumentations. Spine 28:1821–1828PubMedCrossRef
36.
Zurück zum Zitat Sekhon LH (2005) Posterior cervical lateral mass screw fixation: analysis of 1026 consecutive screws in 143 patients. J Spinal Disord Tech 18:297–303PubMedCrossRef Sekhon LH (2005) Posterior cervical lateral mass screw fixation: analysis of 1026 consecutive screws in 143 patients. J Spinal Disord Tech 18:297–303PubMedCrossRef
37.
Zurück zum Zitat Shamji MF, Cook C, Pietrobon R, Tackett S, Brown C, Isaacs RE (2009) Impact of surgical approach on complications and resource utilization of cervical spine fusion: a nationwide perspective to the surgical treatment of diffuse cervical spondylosis. Spine J 9:31–38PubMedCrossRef Shamji MF, Cook C, Pietrobon R, Tackett S, Brown C, Isaacs RE (2009) Impact of surgical approach on complications and resource utilization of cervical spine fusion: a nationwide perspective to the surgical treatment of diffuse cervical spondylosis. Spine J 9:31–38PubMedCrossRef
38.
Zurück zum Zitat Shunwu F, Xing Z, Fengdong Z, Xiangqian F (2010) Minimally invasive transforaminal lumbar interbody fusion for the treatment of degenerative lumbar diseases. Spine (Phila Pa 1976) 35:1615–1620CrossRef Shunwu F, Xing Z, Fengdong Z, Xiangqian F (2010) Minimally invasive transforaminal lumbar interbody fusion for the treatment of degenerative lumbar diseases. Spine (Phila Pa 1976) 35:1615–1620CrossRef
39.
Zurück zum Zitat Su P, Ma R, Li C, Liu S, Huang D (2007) Pedicle screw fixation of the cervical spine: guidance by computed tomography. Clin Orthop Relat Res 462:99–104PubMedCrossRef Su P, Ma R, Li C, Liu S, Huang D (2007) Pedicle screw fixation of the cervical spine: guidance by computed tomography. Clin Orthop Relat Res 462:99–104PubMedCrossRef
40.
Zurück zum Zitat Thongtrangan I, Le H, Park J, Kim DH (2004) Minimally invasive spinal surgery: a historical perspective. Neurosurg Focus 16:E13PubMedCrossRef Thongtrangan I, Le H, Park J, Kim DH (2004) Minimally invasive spinal surgery: a historical perspective. Neurosurg Focus 16:E13PubMedCrossRef
41.
Zurück zum Zitat Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Caglar S, Genc Y (2000) Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47:1162–1168; discussion 1168–1169 Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Caglar S, Genc Y (2000) Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47:1162–1168; discussion 1168–1169
42.
Zurück zum Zitat Ulrich C, Arand M, Nothwang J (2001) Internal fixation on the lower cervical spine–biomechanics and clinical practice of procedures and implants. Eur Spine J 10:88–100PubMedCrossRef Ulrich C, Arand M, Nothwang J (2001) Internal fixation on the lower cervical spine–biomechanics and clinical practice of procedures and implants. Eur Spine J 10:88–100PubMedCrossRef
43.
Zurück zum Zitat Wang MC, Chan L, Maiman DJ, Kreuter W, Deyo RA (2007) Complications and mortality associated with cervical spine surgery for degenerative disease in the United States. Spine (Phila Pa 1976) 32:342–347CrossRef Wang MC, Chan L, Maiman DJ, Kreuter W, Deyo RA (2007) Complications and mortality associated with cervical spine surgery for degenerative disease in the United States. Spine (Phila Pa 1976) 32:342–347CrossRef
44.
Zurück zum Zitat Wang MY, Cummock MD, Yu Y, Trivedi RA (2010) An analysis of the differences in the acute hospitalization charges following minimally invasive versus open posterior lumbar interbody fusion. J Neurosurg 12:694–699 Wang MY, Cummock MD, Yu Y, Trivedi RA (2010) An analysis of the differences in the acute hospitalization charges following minimally invasive versus open posterior lumbar interbody fusion. J Neurosurg 12:694–699
45.
Zurück zum Zitat Wang MY, Levi AD (2006) Minimally invasive lateral mass screw fixation in the cervical spine: initial clinical experience with long-term follow-up. Neurosurgery 58:907–912; discussion 907–912 Wang MY, Levi AD (2006) Minimally invasive lateral mass screw fixation in the cervical spine: initial clinical experience with long-term follow-up. Neurosurgery 58:907–912; discussion 907–912
46.
Zurück zum Zitat Wu JC, Huang WC, Chen YC, Shih YH, Cheng H (2008) Stabilization of subaxial cervical spines by lateral mass screw fixation with modified Magerl’s technique. Surg neurol 70 (Suppl 1):25–33; discussion S21:33 Wu JC, Huang WC, Chen YC, Shih YH, Cheng H (2008) Stabilization of subaxial cervical spines by lateral mass screw fixation with modified Magerl’s technique. Surg neurol 70 (Suppl 1):25–33; discussion S21:33
47.
Zurück zum Zitat Yoshimoto H, Sato S, Hyakumachi T, Yanagibashi Y, Kanno T, Masuda T (2009) Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curve. Eur Spine J 18:1326–1334PubMedCrossRef Yoshimoto H, Sato S, Hyakumachi T, Yanagibashi Y, Kanno T, Masuda T (2009) Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curve. Eur Spine J 18:1326–1334PubMedCrossRef
48.
Zurück zum Zitat Yukawa Y, Kato F, Ito K, Horie Y, Hida T, Nakashima H, Machino M (2009) Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J 18:1293–1299PubMedCrossRef Yukawa Y, Kato F, Ito K, Horie Y, Hida T, Nakashima H, Machino M (2009) Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J 18:1293–1299PubMedCrossRef
Metadaten
Titel
Percutaneous instrumentation of the cervical and cervico-thoracic spine using pedicle screws: preliminary clinical results and analysis of accuracy
verfasst von
Christian Schaefer
Phillip Begemann
Ina Fuhrhop
Malte Schroeder
Lennart Viezens
Lothar Wiesner
Nils Hansen-Algenstaedt
Publikationsdatum
01.06.2011
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 6/2011
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1775-9

Weitere Artikel der Ausgabe 6/2011

European Spine Journal 6/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.