Skip to main content
Erschienen in: European Spine Journal 7/2015

01.11.2015 | Original Article

Is it possible to preserve lumbar lordosis after hybrid stabilization? Preliminary results of a novel rigid–dynamic stabilization system in degenerative lumbar pathologies

verfasst von: Matteo Formica, Luca Cavagnaro, Marco Basso, Andrea Zanirato, Lamberto Felli, Carlo Formica

Erschienen in: European Spine Journal | Sonderheft 7/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose of the study

To evaluate the results of a novel rigid–dynamic stabilization technique in lumbar degenerative segment diseases (DSD), expressly pointing out the preservation of postoperative lumbar lordosis (LL).

Materials and methods

Forty-one patients with one level lumbar DSD and initial disc degeneration at the adjacent level were treated. Circumferential lumbar arthrodesis and posterior hybrid instrumentation were performed to preserve an initial disc degeneration above the segment that has to be fused. Clinical and spino-pelvic parameters were evaluated pre- and postoperatively.

Results

At 2-year follow-up, a significant improvement of clinical outcomes was reported. No statistically significant difference was noted between postoperative and 2-year follow-up in LL and in disc/vertebral body height ratio at the upper adjacent fusion level.

Conclusions

When properly selected, this technique leads to good results. A proper LL should be achieved after any hybrid stabilization to preserve the segment above the fusion.
Literatur
1.
Zurück zum Zitat Goh KJ, Khalifa W, Anslow P, Cadoux-Hudson T, Donaghy M (2004) The clinical syndrome associated with lumbar spinal stenosis. Eur Neurol 52:242–249CrossRefPubMed Goh KJ, Khalifa W, Anslow P, Cadoux-Hudson T, Donaghy M (2004) The clinical syndrome associated with lumbar spinal stenosis. Eur Neurol 52:242–249CrossRefPubMed
2.
Zurück zum Zitat Schwarzer AC, Aprill CN, Derby R, Fortin J, Kine G, Bogduk N (1995) The prevalence and clinical features of internal disc disruption in patients with chronic low back pain. Spine 20(17):1878–1883CrossRefPubMed Schwarzer AC, Aprill CN, Derby R, Fortin J, Kine G, Bogduk N (1995) The prevalence and clinical features of internal disc disruption in patients with chronic low back pain. Spine 20(17):1878–1883CrossRefPubMed
3.
Zurück zum Zitat Bridwell KH, Sedgewick TA, O’Brien MF, Lenke LG, Baldus C (1993) The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 6:461–472CrossRefPubMed Bridwell KH, Sedgewick TA, O’Brien MF, Lenke LG, Baldus C (1993) The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 6:461–472CrossRefPubMed
4.
Zurück zum Zitat Nockels RP (2005) Dynamic stabilization in the surgical management of painful lumbar spinal disorders. Spine 30(16 Suppl):S68–S72CrossRefPubMed Nockels RP (2005) Dynamic stabilization in the surgical management of painful lumbar spinal disorders. Spine 30(16 Suppl):S68–S72CrossRefPubMed
5.
Zurück zum Zitat Shono Y, Kaneda K, Abumi K et al (1998) Stability of posterior spinal instrumentation and its effects on adjacent motion segments in the lumbosacral spine. Spine 23:1550–1558CrossRefPubMed Shono Y, Kaneda K, Abumi K et al (1998) Stability of posterior spinal instrumentation and its effects on adjacent motion segments in the lumbosacral spine. Spine 23:1550–1558CrossRefPubMed
6.
Zurück zum Zitat Kanayama M, Hashimoto T, Shigenobu K, Togawa D, Oha F (2007) A minimum 10-year follow-up of posterior dynamic stabilization using graf artificial ligament. Spine 32:1992–1996CrossRefPubMed Kanayama M, Hashimoto T, Shigenobu K, Togawa D, Oha F (2007) A minimum 10-year follow-up of posterior dynamic stabilization using graf artificial ligament. Spine 32:1992–1996CrossRefPubMed
7.
Zurück zum Zitat Formica M, Cavagnaro L, Formica C, Mastrogiacomo M, Basso M, Di Martino A (2015) What is the preclinical evidence on platelet rich plasma and intervertebral disc degeneration? Eur Spine J. doi:10.1007/s00586-015-4189-2 Formica M, Cavagnaro L, Formica C, Mastrogiacomo M, Basso M, Di Martino A (2015) What is the preclinical evidence on platelet rich plasma and intervertebral disc degeneration? Eur Spine J. doi:10.​1007/​s00586-015-4189-2
8.
Zurück zum Zitat Korovessis P, Papazisis Z, Koureas G, Lambiris E (2004) Rigid, semirigid versus dynamic instrumentation for degenerative lumbar spinal stenosis: a correlative radiological and clinical analysis of short-term results. Spine 29(7):735–742 (Phila Pa 1976) CrossRefPubMed Korovessis P, Papazisis Z, Koureas G, Lambiris E (2004) Rigid, semirigid versus dynamic instrumentation for degenerative lumbar spinal stenosis: a correlative radiological and clinical analysis of short-term results. Spine 29(7):735–742 (Phila Pa 1976) CrossRefPubMed
9.
Zurück zum Zitat Legaye J (2005) Unfavorable influence of the dynamic neutralization system on sagittal balance of the spine. Rev Chir Orthop Repar Appar Mot 91(6):542–550CrossRef Legaye J (2005) Unfavorable influence of the dynamic neutralization system on sagittal balance of the spine. Rev Chir Orthop Repar Appar Mot 91(6):542–550CrossRef
10.
Zurück zum Zitat Chen H, Charles YP, Bogorin I, Steib JP (2011) Influence of two different dynamic stabilization systems on sagittal spinopelvic alignment. J Spinal Disord Tech 24(1):37–43CrossRefPubMed Chen H, Charles YP, Bogorin I, Steib JP (2011) Influence of two different dynamic stabilization systems on sagittal spinopelvic alignment. J Spinal Disord Tech 24(1):37–43CrossRefPubMed
11.
Zurück zum Zitat Legaye J, Duval-Beaupère G, Hecquet J, Marty C (1998) Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves. Eur Spine J 7(2):99–103PubMedCentralCrossRefPubMed Legaye J, Duval-Beaupère G, Hecquet J, Marty C (1998) Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves. Eur Spine J 7(2):99–103PubMedCentralCrossRefPubMed
12.
Zurück zum Zitat Beastall J, Karadimas E, Siddiqui M, Nicol M, Hughes J, Smith F et al (2007) The Dynesys lumbar spinal stabilization system: a preliminary report on positional magnetic resonance imaging findings. Spine 32:685–690CrossRefPubMed Beastall J, Karadimas E, Siddiqui M, Nicol M, Hughes J, Smith F et al (2007) The Dynesys lumbar spinal stabilization system: a preliminary report on positional magnetic resonance imaging findings. Spine 32:685–690CrossRefPubMed
13.
Zurück zum Zitat Gillet P (2003) The fate of the adjacent motion segments after lumbar fusion. J Spinal Disord Tech 16(4):338–345CrossRefPubMed Gillet P (2003) The fate of the adjacent motion segments after lumbar fusion. J Spinal Disord Tech 16(4):338–345CrossRefPubMed
14.
Zurück zum Zitat Sengupta DK, Herkowitz HN (2005) Degenerative spondylolisthesis: review of current trends and controversies. Spine 30:S71–S81CrossRefPubMed Sengupta DK, Herkowitz HN (2005) Degenerative spondylolisthesis: review of current trends and controversies. Spine 30:S71–S81CrossRefPubMed
15.
Zurück zum Zitat Schmoelz W, Huber JF, Nydegger T, Dipl-Ing Claes L, Wilke HJ (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments. J Spinal Disord Tech 16(4):418–423CrossRefPubMed Schmoelz W, Huber JF, Nydegger T, Dipl-Ing Claes L, Wilke HJ (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments. J Spinal Disord Tech 16(4):418–423CrossRefPubMed
16.
Zurück zum Zitat Putzier M, Schneider SV, Funk J, Perka C (2004) Application of a dynamic pedicle screw system (DYNESYS) for lumbar segmental degenerations-comparison of clinical and radiological results for different indications. Z Orthop Ihre Grenzgeb 142(2):166–173CrossRefPubMed Putzier M, Schneider SV, Funk J, Perka C (2004) Application of a dynamic pedicle screw system (DYNESYS) for lumbar segmental degenerations-comparison of clinical and radiological results for different indications. Z Orthop Ihre Grenzgeb 142(2):166–173CrossRefPubMed
17.
Zurück zum Zitat Di Silvestre M, Lolli F, Bakaloudis G, Parisini P (2010) Dynamic stabilization for degenerative lumbar scoliosis in elderly patients. Spine 35(2):227–234 (Phila Pa 1976); 15 CrossRefPubMed Di Silvestre M, Lolli F, Bakaloudis G, Parisini P (2010) Dynamic stabilization for degenerative lumbar scoliosis in elderly patients. Spine 35(2):227–234 (Phila Pa 1976); 15 CrossRefPubMed
18.
Zurück zum Zitat Turner JL, Paller DJ, Murrell CB (2010) The mechanical effect of commercially pure titanium and polyetheretherketone rods on spinal implants at the operative and adjacent levels. Spine 35(21):E1076–E1082CrossRefPubMed Turner JL, Paller DJ, Murrell CB (2010) The mechanical effect of commercially pure titanium and polyetheretherketone rods on spinal implants at the operative and adjacent levels. Spine 35(21):E1076–E1082CrossRefPubMed
19.
Zurück zum Zitat Melnyk AD, Chak JD, Singh V, Kelly A, Cripton PA, Fisher CG, Dvorak MF, Oxland TR (2015) Characterization of the behavior of a novel low-stiffness posterior spinal implant under anterior shear loading on a degenerative spinal model. Eur Spine J (Epub ahead of print) Melnyk AD, Chak JD, Singh V, Kelly A, Cripton PA, Fisher CG, Dvorak MF, Oxland TR (2015) Characterization of the behavior of a novel low-stiffness posterior spinal implant under anterior shear loading on a degenerative spinal model. Eur Spine J (Epub ahead of print)
20.
Zurück zum Zitat Roussouly P, Gollogly S, Berthonnaud E, Dimnet J (2005) Classification of the normal variation in the sagittal alignment of the human lumbar spine and pelvis in the standing position. Spine 30(3):346–353CrossRefPubMed Roussouly P, Gollogly S, Berthonnaud E, Dimnet J (2005) Classification of the normal variation in the sagittal alignment of the human lumbar spine and pelvis in the standing position. Spine 30(3):346–353CrossRefPubMed
21.
Zurück zum Zitat Harrison DD, Cailliet R, Janik TJ, Troyanovich SJ, Harrison DE, Holland B (1998) Elliptical modeling of the sagittal lumbar lordosis and segmental rotation angles as a method to discriminate between normal and low back pain subjects. J Spinal Disord 11(5):430–439CrossRefPubMed Harrison DD, Cailliet R, Janik TJ, Troyanovich SJ, Harrison DE, Holland B (1998) Elliptical modeling of the sagittal lumbar lordosis and segmental rotation angles as a method to discriminate between normal and low back pain subjects. J Spinal Disord 11(5):430–439CrossRefPubMed
22.
Zurück zum Zitat Formica M, Berjano P, Cavagnaro L, Zanirato A, Piazzolla A, Formica C (2014) Extreme lateral approach to the spine in degenerative and post traumatic lumbar diseases: selection process, results and complications. Eur Spine J 23(Suppl 6):684–692CrossRefPubMed Formica M, Berjano P, Cavagnaro L, Zanirato A, Piazzolla A, Formica C (2014) Extreme lateral approach to the spine in degenerative and post traumatic lumbar diseases: selection process, results and complications. Eur Spine J 23(Suppl 6):684–692CrossRefPubMed
23.
Zurück zum Zitat Cecchinato R, Berjano P, Bassani R, Sinigaglia A, Lamartina C (2014) How do interbody devices affect sagittal plane alignment. J Neurosurg Sci 58(2 Suppl 1):87–90PubMed Cecchinato R, Berjano P, Bassani R, Sinigaglia A, Lamartina C (2014) How do interbody devices affect sagittal plane alignment. J Neurosurg Sci 58(2 Suppl 1):87–90PubMed
24.
Zurück zum Zitat Schwab F, Lafage V, Patel A, Farcy JP (2009) Sagittal plane considerations and the pelvis in the adult patient. Spine 34:1828–1833CrossRefPubMed Schwab F, Lafage V, Patel A, Farcy JP (2009) Sagittal plane considerations and the pelvis in the adult patient. Spine 34:1828–1833CrossRefPubMed
25.
Zurück zum Zitat Lamartina C, Berjano P, Petruzzi M, Sinigaglia A, Casero G, Cecchinato R, Damilano M, Bassani R (2012) Criteria to restore the sagittal balance in deformity and degenerative spondylolisthesis. Eur Spine J 21(Suppl 1):S27–S31CrossRefPubMed Lamartina C, Berjano P, Petruzzi M, Sinigaglia A, Casero G, Cecchinato R, Damilano M, Bassani R (2012) Criteria to restore the sagittal balance in deformity and degenerative spondylolisthesis. Eur Spine J 21(Suppl 1):S27–S31CrossRefPubMed
Metadaten
Titel
Is it possible to preserve lumbar lordosis after hybrid stabilization? Preliminary results of a novel rigid–dynamic stabilization system in degenerative lumbar pathologies
verfasst von
Matteo Formica
Luca Cavagnaro
Marco Basso
Andrea Zanirato
Lamberto Felli
Carlo Formica
Publikationsdatum
01.11.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe Sonderheft 7/2015
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-4264-8

Weitere Artikel der Sonderheft 7/2015

European Spine Journal 7/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.