Abstract

Purpose

The goal of this study was to compare the accuracy of a novel intraoperative cone beam computed tomography (CBCT) imaging technique with that of conventional computed tomography (CT) scans for assessment of pedicle screw placement and breach detection.

Methods

Three hundred and forty-eight pedicle screws were inserted in 58 patients between October 2013 and March 2016. All patients had an intraoperative CBCT scan and a conventional CT scan to verify the placement of the screws. The CBCT and CT images were reviewed by two surgeons to assess the accuracy of screw placement and detect pedicle breaches using two established classification systems. Agreement on screw placement between intraoperative CBCT and postoperative CT was assessed using Kappa and Gwet’s coefficients. Using CT scanning as the gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated to determine the ability of CBCT imaging to accurately evaluate screw placement.

Results

The Kappa coefficient was 0.78 using the Gertzbein classification and 0.80 using the Heary classification, indicating a substantial agreement between the intraoperative CBCT and postoperative CT images. Gwet’s coefficient was 0.94 for both classifications, indicating almost perfect agreement. The sensitivity, specificity, positive predictive value and negative predictive value of the CBCT images were 77, 98, 86, and 96%, respectively, for the Gertzbein classification and 79, 98, 88, and 96%, respectively, for the Heary classification.

Conclusions

Intraoperative CBCT provides accurate assessment of pedicle screw placement and enables intraoperative repositioning of misplaced screws. This technique may make postoperative CT imaging unnecessary.
Literatur
2.
Zurück zum Zitat Mobbs RJ, Sivabalan P, Li J (2011) Technique, challenge and indications for percutaneous pedicle screw fixation. J Clin Neurosci 18(6):741–749CrossRefPubMed Mobbs RJ, Sivabalan P, Li J (2011) Technique, challenge and indications for percutaneous pedicle screw fixation. J Clin Neurosci 18(6):741–749CrossRefPubMed
3.
Zurück zum Zitat Jutte PC, Castelein RM (2002) Complications of pedicle screws in lumbar and lumbosacral fusion in 105 consecutive primary operations. Eur Spine J 11(6):594–598CrossRefPubMed Jutte PC, Castelein RM (2002) Complications of pedicle screws in lumbar and lumbosacral fusion in 105 consecutive primary operations. Eur Spine J 11(6):594–598CrossRefPubMed
4.
5.
Zurück zum Zitat Donohue ML, Moquin RR, Singla A, Calancie B (2014) Is in vivo manual palpation for thoracic pedicle screw instrumentation reliable? J Neurosurg Spine 20:492–496CrossRefPubMed Donohue ML, Moquin RR, Singla A, Calancie B (2014) Is in vivo manual palpation for thoracic pedicle screw instrumentation reliable? J Neurosurg Spine 20:492–496CrossRefPubMed
6.
Zurück zum Zitat Lehman RA, Potter BK, Kuklo TR, Chang AS (2004) Probing for thoracic pedicle screw tract violation(s): is it valid? J Spinal Disord Tech 17(4):227–283CrossRef Lehman RA, Potter BK, Kuklo TR, Chang AS (2004) Probing for thoracic pedicle screw tract violation(s): is it valid? J Spinal Disord Tech 17(4):227–283CrossRef
7.
Zurück zum Zitat Sembrano JN, Polly DW Jr, Ledonio CG, Santos ER (2016) Intraoperative 3-dimensional imaging (O)arm for assessment of pedicle screw position: does it prevent unacceptable screw placement? Int J Spine Surg 6:49–54CrossRef Sembrano JN, Polly DW Jr, Ledonio CG, Santos ER (2016) Intraoperative 3-dimensional imaging (O)arm for assessment of pedicle screw position: does it prevent unacceptable screw placement? Int J Spine Surg 6:49–54CrossRef
8.
Zurück zum Zitat Santos ER, Ledonio CG, Castro CA, Truong WH, Sembrano JN (2012) The accuracy of intraoperative O-arm images for the assessment of pedicle screw position. Spine (Phila Pa 1976) 37(2):E119–E125CrossRef Santos ER, Ledonio CG, Castro CA, Truong WH, Sembrano JN (2012) The accuracy of intraoperative O-arm images for the assessment of pedicle screw position. Spine (Phila Pa 1976) 37(2):E119–E125CrossRef
9.
Zurück zum Zitat Rao G, Brodke DS, Rondina M, Dailey AT (2002) Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg (Spine 2) 97:223–226CrossRef Rao G, Brodke DS, Rondina M, Dailey AT (2002) Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg (Spine 2) 97:223–226CrossRef
10.
Zurück zum Zitat Faber GL, Place HM, Mazur RA et al (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine (Phila Pa 1976) 20(13):1494–1499CrossRef Faber GL, Place HM, Mazur RA et al (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine (Phila Pa 1976) 20(13):1494–1499CrossRef
11.
Zurück zum Zitat Steinmann JC, Herkowitz HO, El-Kommos H, Wesolowski DP (1993) Spinal pedicle fixation: confirmation of an image-based technique for screw placement. Spine (Phila Pa 1976) 18:1856–1861CrossRef Steinmann JC, Herkowitz HO, El-Kommos H, Wesolowski DP (1993) Spinal pedicle fixation: confirmation of an image-based technique for screw placement. Spine (Phila Pa 1976) 18:1856–1861CrossRef
12.
Zurück zum Zitat Scheufler KM, Franke J, Eckardt A, Dohmen H (2011) Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine. Neurosurgery 69(6):1307–1316CrossRefPubMed Scheufler KM, Franke J, Eckardt A, Dohmen H (2011) Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine. Neurosurgery 69(6):1307–1316CrossRefPubMed
13.
Zurück zum Zitat St Garber, Bisson EF, Schmidt MH (2012) Comparison of three-dimensional fluoroscopy versus postoperative computed tomography for the assessment of accurate screw placement after instrumented spine surgery. Global Spine J 2(2):95–98CrossRef St Garber, Bisson EF, Schmidt MH (2012) Comparison of three-dimensional fluoroscopy versus postoperative computed tomography for the assessment of accurate screw placement after instrumented spine surgery. Global Spine J 2(2):95–98CrossRef
14.
Zurück zum Zitat Ling JM et al (2014) Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging improves placement accuracy. J Clin Neurosci 21:493–498CrossRefPubMed Ling JM et al (2014) Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging improves placement accuracy. J Clin Neurosci 21:493–498CrossRefPubMed
15.
Zurück zum Zitat Zhang J, Weir V, Fajardo L, Lin J, Hsiung H, Ritenour R (2009) Dosimetric characterization of cone-beam O-arm™ imaging system. J X-ray Sci Technol 17:305–317. doi:10.3233/XST-2009-0231 Zhang J, Weir V, Fajardo L, Lin J, Hsiung H, Ritenour R (2009) Dosimetric characterization of cone-beam O-arm™ imaging system. J X-ray Sci Technol 17:305–317. doi:10.​3233/​XST-2009-0231
16.
Zurück zum Zitat Boland J, Wang L, Love B, Christofi M, Muller D (2016) Impact of new-generation hybrid imaging technology on radiation dose during percutaneous coronary interventions and trans-femoral aortic valve implantations: a comparison with conventional flat-plate angiography. Hurt Lung Circ 25:668–675CrossRef Boland J, Wang L, Love B, Christofi M, Muller D (2016) Impact of new-generation hybrid imaging technology on radiation dose during percutaneous coronary interventions and trans-femoral aortic valve implantations: a comparison with conventional flat-plate angiography. Hurt Lung Circ 25:668–675CrossRef
17.
Zurück zum Zitat Vogl J, Naguib N, Nour Eldin N, Lehnert T, Mbalisike E (2009) Transarterielle Chemo-perfusion und-embolisation thorakaler Neoplasmen mittels C-Arm-CT. Der Radiol 49:837–841. doi:10.1007/s00117-009-1863-6 CrossRef Vogl J, Naguib N, Nour Eldin N, Lehnert T, Mbalisike E (2009) Transarterielle Chemo-perfusion und-embolisation thorakaler Neoplasmen mittels C-Arm-CT. Der Radiol 49:837–841. doi:10.​1007/​s00117-009-1863-6 CrossRef
18.
Zurück zum Zitat Diana M, Liu Y, Pop R, King S et al (2016) Superselective intra-arterial hepatic injection of indocyanine green (ICG) for fluorescence image-guided segmental positive staining: experimental prof of the concept. Surg Endosc 3:1451–1460. doi:10.1007/s00464-016-5136-y Diana M, Liu Y, Pop R, King S et al (2016) Superselective intra-arterial hepatic injection of indocyanine green (ICG) for fluorescence image-guided segmental positive staining: experimental prof of the concept. Surg Endosc 3:1451–1460. doi:10.​1007/​s00464-016-5136-y
19.
Zurück zum Zitat Richter PH, Yarboro S, Kraus M, Gebhard F (2015) One year orthopaedic trauma experience using an advanced interdisciplinary hybrid operating room. Injury 46(Suppl 4):S129–S134CrossRefPubMed Richter PH, Yarboro S, Kraus M, Gebhard F (2015) One year orthopaedic trauma experience using an advanced interdisciplinary hybrid operating room. Injury 46(Suppl 4):S129–S134CrossRefPubMed
20.
Zurück zum Zitat Raftopoulos C, Waterkeyn F, Fomekong E, Duprez T (2012) Percutaneous pedicle screw implantation for refractory low back pain: from manual 2D to fully robotic intraoperative 2D/3D fluoroscopy. Adv Tech Stand Neurosurg 38:75–93CrossRefPubMed Raftopoulos C, Waterkeyn F, Fomekong E, Duprez T (2012) Percutaneous pedicle screw implantation for refractory low back pain: from manual 2D to fully robotic intraoperative 2D/3D fluoroscopy. Adv Tech Stand Neurosurg 38:75–93CrossRefPubMed
21.
Zurück zum Zitat Stecker S et al (2009) Guidelines for patient radiation dose management. J Vasc Interv Radiol 20:S263–S273CrossRefPubMed Stecker S et al (2009) Guidelines for patient radiation dose management. J Vasc Interv Radiol 20:S263–S273CrossRefPubMed
23.
Zurück zum Zitat IEC (2010) Report 60601 medical electrical equipment—part 2–43: particular requirement for the safety of X-ray equipment for interventional procedures, 2nd edn. International Electrotechnical Commission, Geneva IEC (2010) Report 60601 medical electrical equipment—part 2–43: particular requirement for the safety of X-ray equipment for interventional procedures, 2nd edn. International Electrotechnical Commission, Geneva
24.
Zurück zum Zitat Paul J, Jacobi V, Farhang M, Bazrafshan B, Vogl T, Mbalisike E (2013) Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy. Eur Radiol 23:1582–1593. doi:10.1007/s00330-012-2737-2 CrossRefPubMed Paul J, Jacobi V, Farhang M, Bazrafshan B, Vogl T, Mbalisike E (2013) Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy. Eur Radiol 23:1582–1593. doi:10.​1007/​s00330-012-2737-2 CrossRefPubMed
25.
Zurück zum Zitat Sim J, Wright CC (2005) The Kappa Statistics in reliability studies: use, interpretation and sample size requirements. Phys Ther 85(3):257–268PubMed Sim J, Wright CC (2005) The Kappa Statistics in reliability studies: use, interpretation and sample size requirements. Phys Ther 85(3):257–268PubMed
26.
Zurück zum Zitat Gwet KL (2014) Handbook of inter-rater reliability: the definitive guide to measuring the extent agreement among multiple raters, 4th edn. Advanced Analytics, LLC, Gaithersburg, USA Gwet KL (2014) Handbook of inter-rater reliability: the definitive guide to measuring the extent agreement among multiple raters, 4th edn. Advanced Analytics, LLC, Gaithersburg, USA
27.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
29.
Zurück zum Zitat Brooks D, Eskander M, Balsis S, Ordway N, Connolly P (2007) Imaging assessment of lumbar pedicle screw placement. sensitivity and specificity of plain radiographs and computer axial tomography. Spine 32(13):1450–1453CrossRefPubMed Brooks D, Eskander M, Balsis S, Ordway N, Connolly P (2007) Imaging assessment of lumbar pedicle screw placement. sensitivity and specificity of plain radiographs and computer axial tomography. Spine 32(13):1450–1453CrossRefPubMed
30.
Zurück zum Zitat Learch T, Massie J, Pathria M, Ahlgren B, Garfin S (2004) Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine (Phila Pa 1976) 29(7):767–773CrossRef Learch T, Massie J, Pathria M, Ahlgren B, Garfin S (2004) Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine (Phila Pa 1976) 29(7):767–773CrossRef
31.
Zurück zum Zitat Yoo J, Ghanayem A, Petersilge C, Lewin J (1997) Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine. Spine 22(22):2668–2671CrossRefPubMed Yoo J, Ghanayem A, Petersilge C, Lewin J (1997) Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine. Spine 22(22):2668–2671CrossRefPubMed
32.
Zurück zum Zitat Kaminski L, Cordemans V, Cartiaux O, Van Cauter M (2017) Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study. Eur Spine. doi:10.1007/s00586-017-4968-z Kaminski L, Cordemans V, Cartiaux O, Van Cauter M (2017) Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study. Eur Spine. doi:10.​1007/​s00586-017-4968-z
33.
Zurück zum Zitat Harstall R, Heini PF, Mini RL, Orler R (2005) Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study. Spine 30:1893–1898CrossRefPubMed Harstall R, Heini PF, Mini RL, Orler R (2005) Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study. Spine 30:1893–1898CrossRefPubMed
34.
Zurück zum Zitat Gebhard FT, Kraus MD, Scneider E et al (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine (Phila Pa 1976) 31:2024–2027CrossRef Gebhard FT, Kraus MD, Scneider E et al (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine (Phila Pa 1976) 31:2024–2027CrossRef
35.
Zurück zum Zitat Ling J, Dinesh S, Pang B et al (2014) Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy. J Clin Neurosci 21:493–498CrossRefPubMed Ling J, Dinesh S, Pang B et al (2014) Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy. J Clin Neurosci 21:493–498CrossRefPubMed
36.
Zurück zum Zitat Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9(3):235–240CrossRefPubMedPubMedCentral Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9(3):235–240CrossRefPubMedPubMedCentral
37.
Zurück zum Zitat Jin M, Liu X, Yan H, Han X, Qiu Y, Zhu Z (2015) Doe intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique. Eur Spine J 25(6):1729–1737. doi:10.1007/s00586-015-4012-0 CrossRefPubMed Jin M, Liu X, Yan H, Han X, Qiu Y, Zhu Z (2015) Doe intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique. Eur Spine J 25(6):1729–1737. doi:10.​1007/​s00586-015-4012-0 CrossRefPubMed
Metadaten
Titel
Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection
verfasst von
Virginie Cordemans
Ludovic Kaminski
Xavier Banse
Bernard G. Francq
Olivier Cartiaux
Publikationsdatum
20.05.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 11/2017
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-017-5139-y

Weitere Artikel der Ausgabe 11/2017

European Spine Journal 11/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.