Ausgabe 11/2017
Inhalt (35 Artikel)
The effect of NSAIDs on spinal fusion: a cross-disciplinary review of biochemical, animal, and human studies
Ahilan Sivaganesan, Silky Chotai, Gabrielle White-Dzuro, Matthew J. McGirt, Clinton J. Devin
The current state of the evidence for the use of drains in spinal surgery: systematic review
Salil B. Patel, William Griffiths-Jones, Conor S. Jones, Dino Samartzis, Andrew J. Clarke, Shahid Khan, Oliver M. Stokes
Acute non-traumatic idiopathic spinal subdural hematoma: radiographic findings and surgical results with a literature review
Kazuyoshi Kobayashi, Shiro Imagama, Kei Ando, Yoshihiro Nishida, Naoki Ishiguro
Expert’s Comment concerning Grand Rounds case entitled “Acute non-traumatic idiopathic spinal subdural hematoma: radiographic findings and surgical results with a literature review” by K. Kobayashi, S. Imagama, K. Ando, Y. Nishida, N. Ishiguro (Eur Spine J; 2017)
Massimiliano Visocchi
Two-piece ALIF cage optimizes the bone–implant interface in a 360° setting
Hans-Joachim Wilke, David Volkheimer, Bruce Robie, Finn B. Christensen
Osseointegration improves bone–implant interface of pedicle screws in the growing spine: a biomechanical and histological study using an in vivo immature porcine model
Kanako Shiba, Hiroshi Taneichi, Takashi Namikawa, Satoshi Inami, Daisaku Takeuchi, Yutaka Nohara
Effect of Oxy133, an osteogenic oxysterol, on new bone formation in rat two-level posterolateral fusion model
Zorica Buser, Susan Drapeau, Frank Stappenbeck, Renata C. Pereira, Farhad Parhami, Jeffrey C. Wang
Kinematic efficacy of supplemental anterior lumbar interbody fusion at lumbosacral levels in thoracolumbosacral deformity correction with and without pedicle subtraction osteotomy at L3: an in vitro cadaveric study
Benny T. Dahl, Jonathan A. Harris, Manasa Gudipally, Mark Moldavsky, Saif Khalil, Brandon S. Bucklen
Which patient-reported factors predict referral to spinal surgery? A cohort study among 4987 chronic low back pain patients
Johanna M. van Dongen, Miranda L. van Hooff, Maarten Spruit, Marinus de Kleuver, Raymond W. J. G. Ostelo
Consent: an event or a memory in lumbar spinal surgery? A multi-centre, multi-specialty prospective study of documentation and patient recall of consent content
William B. Lo, Ciaran P. McAuley, Martin J. Gillies, Patrick J. Grover, Erlick A. C. Pereira
Preoperative evaluation of left common iliac vein in oblique lateral interbody fusion at L5–S1
Nam-Su Chung, Chang-Hoon Jeon, Han-Dong Lee, Heon-Ju Kweon
Anatomical evaluation of lumbar nerves using diffusion tensor imaging and implications of lateral decubitus for lateral transpsoas approach
Yasuhiro Oikawa, Yawara Eguchi, Atsuya Watanabe, Sumihisa Orita, Kazuyo Yamauchi, Miyako Suzuki, Yoshihiro Sakuma, Go Kubota, Kazuhide Inage, Takeshi Sainoh, Jun Sato, Kazuki Fujimoto, Masao Koda, Takeo Furuya, Koji Matsumoto, Yoshitada Masuda, Yasuchika Aoki, Kazuhisa Takahashi, Seiji Ohtori
Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study
Ludovic Kaminski, V. Cordemans, O. Cartiaux, M. Van Cauter
Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial
Nathalie Pireau, Virginie Cordemans, Xavier Banse, Nadia Irda, Sébastien Lichtherte, Ludovic Kaminski
Influence of a variation in the position of the arms on the sagittal connection of the gravity line with the spinal structures
Jean Legaye, Ginette Duval-Beaupere
Results of lumbar spondylodeses using different bone grafting materials after transforaminal lumbar interbody fusion (TLIF)
Nicolas Heinz vonderHoeh, Anna Voelker, Christoph-Eckhard Heyde
Do position and size matter? An analysis of cage and placement variables for optimum lordosis in PLIF reconstruction
Priyan R. Landham, Angus S. Don, Peter A. Robertson
The effectiveness of low-dose and high-dose tranexamic acid in posterior lumbar interbody fusion: a double-blinded, placebo-controlled randomized study
Ki-Tack Kim, Cheung-Kue Kim, Yong-Chan Kim, Hyung-Suk Juh, Hyo-Jong Kim, Hyeon-Soo Kim, Se Jung Hong, Hwee Weng Dennis Hey
Screw perforation rates in 359 consecutive patients receiving computer-guided pedicle screw insertion along the cervical to lumbar spine
Masashi Uehara, Jun Takahashi, Shota Ikegami, Shugo Kuraishi, Toshimasa Futatsugi, Hiroyuki Kato
Pull-out strength of patient-specific template-guided vs. free-hand fluoroscopically controlled thoracolumbar pedicle screws: a biomechanical analysis of a randomized cadaveric study
A. Aichmair, M. Moser, M. R. Bauer, E. Bachmann, J. G. Snedeker, M. Betz, M. Farshad
Biomechanical properties of posterior transpedicular–transdiscal oblique lumbar screw fixation with novel trapezoidal lateral interbody spacer: an in vitro human cadaveric model
Ai-Min Wu, Jonathan A. Harris, John C. Hao, Sean M. Jenkins, Yong-Long Chi, Brandon S. Bucklen
Timing of PMMA cement application for pedicle screw augmentation affects screw anchorage
Werner Schmoelz, Christian Heinz Heinrichs, Sven Schmidt, Angel R. Piñera, Felix Tome-Bermejo, Javier M. Duart, Marlies Bauer, Luis Álvarez Galovich
Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength
Lukas Weiser, Gerd Huber, Kay Sellenschloh, Lennart Viezens, Klaus Püschel, Michael M. Morlock, Wolfgang Lehmann
Rate and mode of screw misplacements after 3D-fluoroscopy navigation-assisted insertion and 3D-imaging control of 1547 pedicle screws in spinal levels T10-S1 related to vertebrae and spinal sections
Horst Balling, Thomas R. Blattert
Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection
Virginie Cordemans, Ludovic Kaminski, Xavier Banse, Bernard G. Francq, Olivier Cartiaux
Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws
Virginie Cordemans, Ludovic Kaminski, Xavier Banse, Bernard G. Francq, Christine Detrembleur, Olivier Cartiaux
Are computer numerical control (CNC)-manufactured patient-specific metal templates available for posterior thoracic pedicle screw insertion? Feasibility and accuracy evaluation
Xiangxue Kong, Lei Tang, Qiang Ye, Wenhua Huang, Jianyi Li
Accuracy of 3D fluoro-navigated anterior transpedicular screws in the subaxial cervical spine: an experimental study on human specimens
Jan Bredow, C. Meyer, F. Siedek, W. F. Neiss, L. Löhrer, L. P. Müller, P. Eysel, G. Stein
S2-AI screw placement with the aide of electronic conductivity device monitoring: a retrospective analysis
Faheem A. Sandhu, Jason E. McGowan, Daniel R. Felbaum, Hasan R. Syed, Kyle B. Mueller
Accuracy of cannulated pedicle screw versus conventional pedicle screw for extra-pedicular screw placement in dysplastic pedicles without cancellous channel in adolescent idiopathic scoliosis: a computerized tomography (CT) analysis
Chee Kean Lee, Chris Yin Wei Chan, Siti Mariam Abd Gani, Mun Keong Kwan
Comparative study of the efficacy of transdermal buprenorphine patches and prolonged-release tramadol tablets for postoperative pain control after spinal fusion surgery: a prospective, randomized controlled non-inferiority trial
Ho-Joong Kim, Hyo Sae Ahn, Yunjin Nam, Bong-Soon Chang, Choon-Ki Lee, Jin S. Yeom
Effect of zoledronic acid on lumbar spinal fusion in osteoporotic patients
Qirui Ding, Jian Chen, Jin Fan, Qingqing Li, Guoyong Yin, Lipeng Yu