Skip to main content
Erschienen in: Clinical Oral Investigations 2/2012

01.04.2012 | Original Article

Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area

verfasst von: Ting-Hsun Lan, Je-Kang Du, Chin-Yun Pan, Huey-Er Lee, Wei-Hao Chung

Erschienen in: Clinical Oral Investigations | Ausgabe 2/2012

Einloggen, um Zugang zu erhalten

Abstract

Threaded implants have been shown to play an important role in increasing mechanical osseointegration. The aim of this study was to determine bone stress distribution when using different types of implant thread pitches and designs. Five 3D finite element models were constructed to simulate bone stresses induced in implant bodies with two types of thread form: triangular (“Tri” prefix) and trapezoidal (“Trap” prefix). The former had thread pitches of 0.8, 1.2, and 1.6 mm, while the latter had thread pitches of 1.2 and 1.6 mm. A biting load of 143 N was applied vertically and obliquely to the occlusal central fossa of the crown. The main effects of each level of the three factors investigated (loading type, pitch, and thread form) in terms of the stress value were computed for all models. Results indicated that the loading type was the main factor of influence on the peak compressive stress of the alveolar bone. Optimal thread pitch was 1.2 mm for a triangular-thread implant, and a trapezoidal-threaded implant with thread pitch of 1.6 mm had the lowest stress value among trapezoidal-threaded implants. This study concluded that each thread form has its unique optimal thread pitch with regard to lower concentration of bone stress. Clinically, this study suggests that in biomechanical consideration, thread pitch exceeding 0.8 mm is more appropriate for a screwed implant. For clinical cases that require greater bone-implant interface, trapezoidal-threaded implants with thread pitch of 1.6 mm provide greater primary stability and lower concentration of bone stress under different loading directions.
Literatur
1.
Zurück zum Zitat Brägger U, Aeschlimann S, Bürgin W, Hämmerle CH, Lang NP (2001) Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function. Clin Oral Implants Res 12:26–34PubMedCrossRef Brägger U, Aeschlimann S, Bürgin W, Hämmerle CH, Lang NP (2001) Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function. Clin Oral Implants Res 12:26–34PubMedCrossRef
2.
Zurück zum Zitat Kan JY, Rungcharassaeng K, Kim J, Lozada JL, Goodacre CJ (2002) Factors affecting the survival of implants placed in grafted maxillary sinuses: a clinical report. J Prosthet Dent 87:485–489PubMedCrossRef Kan JY, Rungcharassaeng K, Kim J, Lozada JL, Goodacre CJ (2002) Factors affecting the survival of implants placed in grafted maxillary sinuses: a clinical report. J Prosthet Dent 87:485–489PubMedCrossRef
3.
Zurück zum Zitat Steigenga J, Al-Shammari K, Misch C, Nociti FH Jr, Wang HL (2004) Effects of implant thread geometry on percentage of osseointegration and resistance to reverse torque in the tibia of rabbits. J Periodontol 75:1233–1241PubMedCrossRef Steigenga J, Al-Shammari K, Misch C, Nociti FH Jr, Wang HL (2004) Effects of implant thread geometry on percentage of osseointegration and resistance to reverse torque in the tibia of rabbits. J Periodontol 75:1233–1241PubMedCrossRef
4.
Zurück zum Zitat Lee CC, Lin SC, Kang MJ, Wu SW, Fu PY (2010) Effects of implant threads on the contact area and stress distribution of marginal bone. J Dent Sci 5:156–165CrossRef Lee CC, Lin SC, Kang MJ, Wu SW, Fu PY (2010) Effects of implant threads on the contact area and stress distribution of marginal bone. J Dent Sci 5:156–165CrossRef
5.
Zurück zum Zitat Lan TH, Huang HL, Wu JH, Lee HE, Wang CH (2008) Stress analysis on different angulations of implant installation- finite element method. Kaohsiung J Med Sci 24:138–143PubMedCrossRef Lan TH, Huang HL, Wu JH, Lee HE, Wang CH (2008) Stress analysis on different angulations of implant installation- finite element method. Kaohsiung J Med Sci 24:138–143PubMedCrossRef
6.
Zurück zum Zitat Lan TH, Pan CY, Lee HE, Huang HL, Wang CH (2010) Bone stress analysis for various angulations of mesiodistal implants with splinted crowns in the posterior mandible: a three-dimensional finite element study. Int J Oral Maxillofac Implants 25:763–770PubMed Lan TH, Pan CY, Lee HE, Huang HL, Wang CH (2010) Bone stress analysis for various angulations of mesiodistal implants with splinted crowns in the posterior mandible: a three-dimensional finite element study. Int J Oral Maxillofac Implants 25:763–770PubMed
7.
Zurück zum Zitat Le Guehennec L, Soueidan A, Layrolle P, Amouriq Y (2007) Surface treatments of titanium dental implants for rapid osseointegration. Dent Mater 23:844–854PubMedCrossRef Le Guehennec L, Soueidan A, Layrolle P, Amouriq Y (2007) Surface treatments of titanium dental implants for rapid osseointegration. Dent Mater 23:844–854PubMedCrossRef
8.
Zurück zum Zitat Akkocaoglu M, Uysal S, Tekdemir I, Akca K, Cehreli MC (2004) Implant design and intraosseous stability of immediately placed implants: a human cadaver study. Clin Oral Implants Res 16:202–209CrossRef Akkocaoglu M, Uysal S, Tekdemir I, Akca K, Cehreli MC (2004) Implant design and intraosseous stability of immediately placed implants: a human cadaver study. Clin Oral Implants Res 16:202–209CrossRef
9.
Zurück zum Zitat Lin S, Shi S, LeGeros RZ, LeGeros JP (2000) Three-dimensional finite element analyses of four designs of a high-strength silicon nitride implant. Implant Dent 9:53–60PubMedCrossRef Lin S, Shi S, LeGeros RZ, LeGeros JP (2000) Three-dimensional finite element analyses of four designs of a high-strength silicon nitride implant. Implant Dent 9:53–60PubMedCrossRef
10.
Zurück zum Zitat Huang HL, Hsu JT, Fuh LJ, Tu MG, Ko CC, Shen YW (2008) Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: a non-linear finite element study. J Dent 36:409–417PubMedCrossRef Huang HL, Hsu JT, Fuh LJ, Tu MG, Ko CC, Shen YW (2008) Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: a non-linear finite element study. J Dent 36:409–417PubMedCrossRef
11.
Zurück zum Zitat Abuhussein H, Pagni G, Rebaudi A, Wang HL (2010) The effect of thread pattern upon implant osseointegration. Clin Oral Implants Res 21:129–136PubMedCrossRef Abuhussein H, Pagni G, Rebaudi A, Wang HL (2010) The effect of thread pattern upon implant osseointegration. Clin Oral Implants Res 21:129–136PubMedCrossRef
12.
Zurück zum Zitat Hansson S, Werke M (2003) The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. J Biomech 36:1247–1258PubMedCrossRef Hansson S, Werke M (2003) The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. J Biomech 36:1247–1258PubMedCrossRef
13.
Zurück zum Zitat Chun HJ, Cheong SY, Han JH, Heo SJ, Chung JP, Rhyu IC, Choi YC, Baik HK, Ku Y, Kim MH (2002) Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil 29:565–574PubMedCrossRef Chun HJ, Cheong SY, Han JH, Heo SJ, Chung JP, Rhyu IC, Choi YC, Baik HK, Ku Y, Kim MH (2002) Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil 29:565–574PubMedCrossRef
14.
Zurück zum Zitat Eraslan O, Inan O (2010) The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis. Clin Oral Invest 14:411–416CrossRef Eraslan O, Inan O (2010) The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis. Clin Oral Invest 14:411–416CrossRef
15.
Zurück zum Zitat Vidyasagar L, Aspe P (2004) Dental implant design and biological effect on bone-implant interface. Baltic Dent Maxillofac J 6:51–54 Vidyasagar L, Aspe P (2004) Dental implant design and biological effect on bone-implant interface. Baltic Dent Maxillofac J 6:51–54
16.
Zurück zum Zitat Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H (2003) Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 18:357–368PubMed Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H (2003) Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 18:357–368PubMed
17.
Zurück zum Zitat Kitagawa T, Tanimoto Y, Nemoto K, Aida M (2005) Influence of cortical bone quality on stress distribution in bone around dental implant. Dent Mater J 24:219–224PubMedCrossRef Kitagawa T, Tanimoto Y, Nemoto K, Aida M (2005) Influence of cortical bone quality on stress distribution in bone around dental implant. Dent Mater J 24:219–224PubMedCrossRef
18.
Zurück zum Zitat Lin CL, Wang JC, Ramp LC, Liu PR (2008) Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading. Int J Oral Maxillofac Implants 23:57–64PubMed Lin CL, Wang JC, Ramp LC, Liu PR (2008) Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading. Int J Oral Maxillofac Implants 23:57–64PubMed
19.
Zurück zum Zitat Lin CL, Wang JC, Chang WJ (2008) Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis. Clin Oral Implants Res 19:107–117PubMed Lin CL, Wang JC, Chang WJ (2008) Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis. Clin Oral Implants Res 19:107–117PubMed
20.
Zurück zum Zitat Natali AN, Pavan PG, Ruggero AL (2006) Analysis of bone–implant interaction phenomena by using a numerical approach. Clin Oral Implants Res 17:67–74PubMedCrossRef Natali AN, Pavan PG, Ruggero AL (2006) Analysis of bone–implant interaction phenomena by using a numerical approach. Clin Oral Implants Res 17:67–74PubMedCrossRef
21.
Zurück zum Zitat Kong L, Zhao Yh HuK, Li D, Zhou H, Wu Z, Liu B (2009) Selection of the implant thread pitch for optimal biomechanical properties: a three-dimensional finite element analysis. Adv Eng Softw 40:474–478CrossRef Kong L, Zhao Yh HuK, Li D, Zhou H, Wu Z, Liu B (2009) Selection of the implant thread pitch for optimal biomechanical properties: a three-dimensional finite element analysis. Adv Eng Softw 40:474–478CrossRef
22.
Zurück zum Zitat Chung SH, Heo SJ, Koak JY, Kim SK, Lee JB, Han JS, Han CH, Rhyu IC, Lee SJ (2008) Effects of implant geometry and surface treatment on osseointegration after functional loading: a dog study. J Oral Rehabil 35:229–236PubMedCrossRef Chung SH, Heo SJ, Koak JY, Kim SK, Lee JB, Han JS, Han CH, Rhyu IC, Lee SJ (2008) Effects of implant geometry and surface treatment on osseointegration after functional loading: a dog study. J Oral Rehabil 35:229–236PubMedCrossRef
23.
Zurück zum Zitat Akça K, Iplikçioğlu H (2001) Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis. Implant Dent 10:238–245PubMedCrossRef Akça K, Iplikçioğlu H (2001) Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis. Implant Dent 10:238–245PubMedCrossRef
24.
Zurück zum Zitat Meikle MC (2006) The tissue, cellular, and molecular regulation of orthodontic tooth movement: 100 years after Carl Sandstedt. Eur J Orthod 28:221–240PubMedCrossRef Meikle MC (2006) The tissue, cellular, and molecular regulation of orthodontic tooth movement: 100 years after Carl Sandstedt. Eur J Orthod 28:221–240PubMedCrossRef
25.
Zurück zum Zitat O'Mahony AM, Williams JL, Spencer P (2001) Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading. Clin Oral Implants Res 12:648–657PubMedCrossRef O'Mahony AM, Williams JL, Spencer P (2001) Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading. Clin Oral Implants Res 12:648–657PubMedCrossRef
26.
Zurück zum Zitat Haraldson T, Carlsson GE (1977) Bite force and oral function in patients with osseointegrated oral implants. Scand J Dent Res 85:200–208PubMed Haraldson T, Carlsson GE (1977) Bite force and oral function in patients with osseointegrated oral implants. Scand J Dent Res 85:200–208PubMed
27.
Zurück zum Zitat Stanford CM, Brand RA (1999) Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling. J Prosthet Dent 81:553–561PubMedCrossRef Stanford CM, Brand RA (1999) Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling. J Prosthet Dent 81:553–561PubMedCrossRef
28.
Zurück zum Zitat Akagawa Y, Sato Y, Teixeira ER, Shindoi N, Wadamoto M (2003) A mimic osseointegrated implant model for three-dimensional finite element analysis. J Oral Rehabil 30:41–45PubMedCrossRef Akagawa Y, Sato Y, Teixeira ER, Shindoi N, Wadamoto M (2003) A mimic osseointegrated implant model for three-dimensional finite element analysis. J Oral Rehabil 30:41–45PubMedCrossRef
29.
Zurück zum Zitat Dar FH, Meakin JR, Aspden RM (2002) Statistical methods in finite element analysis. J Biomech 35:1155–1161PubMedCrossRef Dar FH, Meakin JR, Aspden RM (2002) Statistical methods in finite element analysis. J Biomech 35:1155–1161PubMedCrossRef
30.
Zurück zum Zitat Geng JP, Ma QS, Xu W, Tan KB, Liu GR (2004) Finite element analysis of four thread-form configurations in a stepped screw implant. J Oral Rehabil 31:233–239PubMedCrossRef Geng JP, Ma QS, Xu W, Tan KB, Liu GR (2004) Finite element analysis of four thread-form configurations in a stepped screw implant. J Oral Rehabil 31:233–239PubMedCrossRef
31.
Zurück zum Zitat English C, Bahat O, Langer B, Sheets CG (2000) What are the clinical limitat ions of wide-diameter (4 mm or greater) root-form endosseous implants. Int J Oral Maxillofac Implants 15:293–296PubMed English C, Bahat O, Langer B, Sheets CG (2000) What are the clinical limitat ions of wide-diameter (4 mm or greater) root-form endosseous implants. Int J Oral Maxillofac Implants 15:293–296PubMed
32.
Zurück zum Zitat Schmitt A, Zarb GA (1993) The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement. Int J Prosthodont 6:197–202PubMed Schmitt A, Zarb GA (1993) The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement. Int J Prosthodont 6:197–202PubMed
33.
Zurück zum Zitat Vigolo P, Givani A (2000) Clinical evaluation of single-tooth mini-implant restoration: a five-year retrospective study. J Prosthet Dent 84:50–54PubMedCrossRef Vigolo P, Givani A (2000) Clinical evaluation of single-tooth mini-implant restoration: a five-year retrospective study. J Prosthet Dent 84:50–54PubMedCrossRef
Metadaten
Titel
Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area
verfasst von
Ting-Hsun Lan
Je-Kang Du
Chin-Yun Pan
Huey-Er Lee
Wei-Hao Chung
Publikationsdatum
01.04.2012
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 2/2012
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-011-0517-z

Weitere Artikel der Ausgabe 2/2012

Clinical Oral Investigations 2/2012 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.