Skip to main content
Erschienen in: Journal of Artificial Organs 1/2014

01.03.2014 | Original Article

Paracorporeal ventricular assist device as a bridge to transplant candidacy in the era of implantable continuous-flow ventricular assist device

verfasst von: Hideaki Suwa, Osamu Seguchi, Tomoyuki Fujita, Yoshihiro Murata, Michinari Hieda, Takuya Watanabe, Takuma Sato, Haruki Sunami, Masanobu Yanase, Hiroki Hata, Takeshi Nakatani

Erschienen in: Journal of Artificial Organs | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

Ventricular assist devices (VADs) have long been used as bridge to transplant therapy (BTT). Nipro-Toyobo paracorporeal pulsatile-flow VAD (nt-VAD) was the only device available until April 2011, when implantable continuous-flow VADs (cf-VADs) became available. Although cf-VADs are central to BTT, nt-VAD remains a necessary option. We aimed to clarify the role of nt-VAD in an era of increasing cf-VAD use. We retrospectively reviewed patients who underwent VAD implantation at the National Cerebral and Cardiovascular Center from May 2011 to March 2013. Characteristics were compared between the nt-VAD and cf-VAD groups. Twenty-nine patients (mean age 37.7 ± 11.1 years, 23 males) underwent VAD implantation. Fifteen patients initially received nt-VADs, although 4 were converted to cf-VADs. Of these 15 patients, 3 were too small for cf-VADs and 2 needed bilateral ventricular support. The remaining 10 patients received nt-VADs (7 patients at INTERMACS level 1 and 3 at level 2). The nt-VAD group patients had significantly more preoperative mechanical circulatory support and were in a more critical condition before VAD implantation than the cf-VAD group. The 2-year survival rate was not significantly different. Despite the critical conditions of nt-VAD patients, their overall survival is not statistically inferior to that of cf-VAD patients. nt-VAD is a good option as a BTC for the patient with urgent and critical condition.
Literatur
1.
Zurück zum Zitat Miller LW, Pagani FD, Russell SD, John R, Boyle AJ, Aaronson KD, Conte JV, Naka Y, Mancini D, Delgado RM, MacGillivray TE, Farrar DJ, Frazier OH, HeartMate II Clinical Investigators. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med. 2007;357:885–96.PubMedCrossRef Miller LW, Pagani FD, Russell SD, John R, Boyle AJ, Aaronson KD, Conte JV, Naka Y, Mancini D, Delgado RM, MacGillivray TE, Farrar DJ, Frazier OH, HeartMate II Clinical Investigators. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med. 2007;357:885–96.PubMedCrossRef
2.
Zurück zum Zitat Pagani FD, Miller LW, Russell SD, Aaronson KD, John R, Boyle AJ, Conte JV, Bogaev RC, MacGillivray TE, Naka Y, Mancini D, Massey HT, Chen L, Klodell CT, Aranda JM, Moazami N, Ewald GA, Farrar DJ, Frazier OH, HeartMate II Investigators. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol. 2009;54:312–21.PubMedCrossRef Pagani FD, Miller LW, Russell SD, Aaronson KD, John R, Boyle AJ, Conte JV, Bogaev RC, MacGillivray TE, Naka Y, Mancini D, Massey HT, Chen L, Klodell CT, Aranda JM, Moazami N, Ewald GA, Farrar DJ, Frazier OH, HeartMate II Investigators. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol. 2009;54:312–21.PubMedCrossRef
3.
Zurück zum Zitat Slaughter MS, Rogers LG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH, HeartMate II Investigators. Advanced heart failure treated with continuous-flow left ventricular assist device. N Eng J Med. 2009;361:2241–51.CrossRef Slaughter MS, Rogers LG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH, HeartMate II Investigators. Advanced heart failure treated with continuous-flow left ventricular assist device. N Eng J Med. 2009;361:2241–51.CrossRef
4.
Zurück zum Zitat Kitamura S. Heart transplantation in Japan: a critical appraisal for the results and future perspects. Gen Thorac Cardiovasc Surg. 2012;60:639–44.PubMedCrossRef Kitamura S. Heart transplantation in Japan: a critical appraisal for the results and future perspects. Gen Thorac Cardiovasc Surg. 2012;60:639–44.PubMedCrossRef
5.
Zurück zum Zitat Kyo S, Minami T, Nishimura T, Gojo S, Ono M. New era for therapeutic strategy for heart failure: destination therapy by left ventricular assist device. J Cardiol. 2012;59:101–9.PubMedCrossRef Kyo S, Minami T, Nishimura T, Gojo S, Ono M. New era for therapeutic strategy for heart failure: destination therapy by left ventricular assist device. J Cardiol. 2012;59:101–9.PubMedCrossRef
6.
Zurück zum Zitat Toda K, Fujita T, Kobayashi J, Shimahara Y, Kitamura S, Seguchi O, Murata Y, Yanase M, Nakatani T. Impact of preoperative percutaneous cardiopulmonary support on outcome following left ventricular assist device implantation. Circ J. 2012;76:88–95.PubMedCrossRef Toda K, Fujita T, Kobayashi J, Shimahara Y, Kitamura S, Seguchi O, Murata Y, Yanase M, Nakatani T. Impact of preoperative percutaneous cardiopulmonary support on outcome following left ventricular assist device implantation. Circ J. 2012;76:88–95.PubMedCrossRef
7.
Zurück zum Zitat Kerklin JK, Naftel DC, Stevenson LW, Kormos RL, Pagani FD, Miller MA, Ulisney KL, Young JB. INTERMACS database for durable devices for circulatory support: first annual report. J Heart Lung Transpl. 2008;10:1065–72.CrossRef Kerklin JK, Naftel DC, Stevenson LW, Kormos RL, Pagani FD, Miller MA, Ulisney KL, Young JB. INTERMACS database for durable devices for circulatory support: first annual report. J Heart Lung Transpl. 2008;10:1065–72.CrossRef
8.
Zurück zum Zitat Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, Tomioka J, Kormos RL, Griffith BP, Kurosawa H. EVAHEART: an implantable centrifugal blood pump for ling-term circulatory support. Jpn J Thorac Cardiovasc Surg. 2002;11:461–5.CrossRef Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, Tomioka J, Kormos RL, Griffith BP, Kurosawa H. EVAHEART: an implantable centrifugal blood pump for ling-term circulatory support. Jpn J Thorac Cardiovasc Surg. 2002;11:461–5.CrossRef
9.
Zurück zum Zitat Nishinaka T, Schima H, Roethy W, Rajek A, Nojiri C, Wolner E, Wieselthaler GM. The Dureheart VAD, a magnetically levitated centrifugal pump: University of Vienna bridge-to-transplant experience. Circ J. 2006;70:1421–5.PubMedCrossRef Nishinaka T, Schima H, Roethy W, Rajek A, Nojiri C, Wolner E, Wieselthaler GM. The Dureheart VAD, a magnetically levitated centrifugal pump: University of Vienna bridge-to-transplant experience. Circ J. 2006;70:1421–5.PubMedCrossRef
10.
11.
Zurück zum Zitat Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Ulisney KL, Baldwin JT, Young JB. Second INTERMACS annual report: more than 1,000 primary left ventricular assist device implant. J Heart Lung Transpl. 2010;29:1–10.CrossRef Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Ulisney KL, Baldwin JT, Young JB. Second INTERMACS annual report: more than 1,000 primary left ventricular assist device implant. J Heart Lung Transpl. 2010;29:1–10.CrossRef
12.
Zurück zum Zitat Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Ulisney KL, Baldwin JT, Young JB. Third INTERMACS annual report: the revolution of destination therapy in the United State. J Heart Lung Transpl. 2011;30:115–23.CrossRef Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Ulisney KL, Baldwin JT, Young JB. Third INTERMACS annual report: the revolution of destination therapy in the United State. J Heart Lung Transpl. 2011;30:115–23.CrossRef
13.
Zurück zum Zitat Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. The fourth INTERMACS annual report: 4,000 implant and counting. J Heart Lung Transpl. 2012;31:117–26.CrossRef Kerklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. The fourth INTERMACS annual report: 4,000 implant and counting. J Heart Lung Transpl. 2012;31:117–26.CrossRef
14.
Zurück zum Zitat Kirklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. Fifth INERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients. J Heart Lung Transpl. 2013;32:141–56.CrossRef Kirklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA, Baldwin JT, Young JB. Fifth INERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients. J Heart Lung Transpl. 2013;32:141–56.CrossRef
15.
Zurück zum Zitat Saito S, Matsumiya G, Sakaguchi T, Miyagawa S, Yoshikawa Y, Yamauchi T, Kuratani T, Sawa Y. Risk factor analysis of long-term support with left ventricular assist system. Circ J. 2010;74:715–22.PubMedCrossRef Saito S, Matsumiya G, Sakaguchi T, Miyagawa S, Yoshikawa Y, Yamauchi T, Kuratani T, Sawa Y. Risk factor analysis of long-term support with left ventricular assist system. Circ J. 2010;74:715–22.PubMedCrossRef
16.
Zurück zum Zitat Yoshioka D, Sakaguchi T, Saito S, Miyagawa S, Nishi H, Yoshikawa Y, Fukushima S, Ueno T, Kuratani T, Sawa Y. Initial experience of conversion of Toyobo paracorporeal left ventricular assist device to DuraHeart left ventricular assist device. Circ J. 2012;76:372–6.PubMedCrossRef Yoshioka D, Sakaguchi T, Saito S, Miyagawa S, Nishi H, Yoshikawa Y, Fukushima S, Ueno T, Kuratani T, Sawa Y. Initial experience of conversion of Toyobo paracorporeal left ventricular assist device to DuraHeart left ventricular assist device. Circ J. 2012;76:372–6.PubMedCrossRef
17.
Zurück zum Zitat Ziemba EA, John R. Mechanical circulatory support for bridge to decision: which device and when to decide. J Card Surg. 2010;25:425–33.PubMedCrossRef Ziemba EA, John R. Mechanical circulatory support for bridge to decision: which device and when to decide. J Card Surg. 2010;25:425–33.PubMedCrossRef
18.
Zurück zum Zitat Gonzalez-Costello J, Yang J, Sims DB, Kossar AP, Murray LK, Colombo PC, et al. Bridging cardiogenic shock patients with short-term ventricular support at a community hospital to long-term ventricular support at a tertiary hospital. J Heart Lung Transpl. 2012;31:618–24.CrossRef Gonzalez-Costello J, Yang J, Sims DB, Kossar AP, Murray LK, Colombo PC, et al. Bridging cardiogenic shock patients with short-term ventricular support at a community hospital to long-term ventricular support at a tertiary hospital. J Heart Lung Transpl. 2012;31:618–24.CrossRef
19.
Zurück zum Zitat John R, Liao K, Lietz K, Kamdar F, Colvin-Adams M, Boyle A, et al. Experience with the Levitronix CentriMug circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure. J Thorac Cardiovasc Surg. 2007;134:351–8.PubMedCrossRef John R, Liao K, Lietz K, Kamdar F, Colvin-Adams M, Boyle A, et al. Experience with the Levitronix CentriMug circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure. J Thorac Cardiovasc Surg. 2007;134:351–8.PubMedCrossRef
Metadaten
Titel
Paracorporeal ventricular assist device as a bridge to transplant candidacy in the era of implantable continuous-flow ventricular assist device
verfasst von
Hideaki Suwa
Osamu Seguchi
Tomoyuki Fujita
Yoshihiro Murata
Michinari Hieda
Takuya Watanabe
Takuma Sato
Haruki Sunami
Masanobu Yanase
Hiroki Hata
Takeshi Nakatani
Publikationsdatum
01.03.2014
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 1/2014
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-013-0731-3

Weitere Artikel der Ausgabe 1/2014

Journal of Artificial Organs 1/2014 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.