Abstract

The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal display (LCD). A sample consisting of 230 anteroposterior (AP), posteroanterior (PA), and lateral views of the chest with CT-proven findings characteristic for ILD as well as 80 normal images were compared. This double-blinded trial produced a sample sufficient to detect if the sensitivity of the LCD was 10% or more reduced (one-sided) from the “gold standard” CRT display. Both displays were calibrated to the DICOM gray scale standard and the coefficient of variation of the luminance function varied less than 2% during the study. Five board-certified radiologists specializing in thoracic radiology interpreted the sample on both displays and the intraobserver Az (area under the ROC curve) showed no significant correlation to the display used. In addition, an interobserver kappa analysis showed that the relative disagreement between any observer pair remained relatively constant between displays, and thus was display invariant. This study demonstrated there is no significant change in observer performance sensitivity on 5-MP CRT versus 3-MP LCD displays for CR examinations demonstrating ILD of the chest.
Literatur
1.
Zurück zum Zitat Landis, RJ, Koch, GG 1977The measurement of observer agreement for categorical dataBiometrics33159174PubMed Landis, RJ, Koch, GG 1977The measurement of observer agreement for categorical dataBiometrics33159174PubMed
2.
Zurück zum Zitat Mathieson, JR, Mayo, JR, Staples, CA, et al. 1989Chronic diffuse infiltrative lung disease: comparison of diagnostic accuracy of CT and chest radiographyRadiology171111116PubMed Mathieson, JR, Mayo, JR, Staples, CA,  et al. 1989Chronic diffuse infiltrative lung disease: comparison of diagnostic accuracy of CT and chest radiographyRadiology171111116PubMed
3.
Zurück zum Zitat Padley, SP, Hansell, DM, Flower, CD, et al. 1991Comparative accuracy of high resolution computed tomography and chest radiography in the diagnosis of chronic diffuse infiltrative lung diseaseClin Radiol44222226PubMed Padley, SP, Hansell, DM, Flower, CD,  et al. 1991Comparative accuracy of high resolution computed tomography and chest radiography in the diagnosis of chronic diffuse infiltrative lung diseaseClin Radiol44222226PubMed
4.
Zurück zum Zitat Ackerman, SC, Gitlin, JN, Gayler, RW, et al. 1993ROC analysis of fracture and pneumonia detection: comparison of laser digitized workstation images and conventional analog radiographsRadiology186263268PubMed Ackerman, SC, Gitlin, JN, Gayler, RW,  et al. 1993ROC analysis of fracture and pneumonia detection: comparison of laser digitized workstation images and conventional analog radiographsRadiology186263268PubMed
5.
Zurück zum Zitat Slasky, BS, Gur, WF, Good, WF, et al. 1990ROC analysis of chest image interpretation with conventional, laser printed and high-resolution workstation imagesRadiology174775780PubMed Slasky, BS, Gur, WF, Good, WF,  et al. 1990ROC analysis of chest image interpretation with conventional, laser printed and high-resolution workstation imagesRadiology174775780PubMed
6.
Zurück zum Zitat Scott, WW, Bluemke, DA, Mysko, WK, et al. 1995Interpretation of ED radiographs by radiologists and emergency medicine physicians: teleradiology workstation vs. radiograph ReadingsRadiology195223229PubMed Scott, WW, Bluemke, DA, Mysko, WK,  et al. 1995Interpretation of ED radiographs by radiologists and emergency medicine physicians: teleradiology workstation vs. radiograph ReadingsRadiology195223229PubMed
7.
Zurück zum Zitat Cox, GG, Cook, LT, McMillan, JH, et al. 1990Chest radiography: comparisons of high-resolution digital displays with conventional and digital filmRadiology176771776PubMed Cox, GG, Cook, LT, McMillan, JH,  et al. 1990Chest radiography: comparisons of high-resolution digital displays with conventional and digital filmRadiology176771776PubMed
8.
Zurück zum Zitat Siegel E, Reiner, B, Moffet, BR, et al.: Differences in Image Quality of CR Images Displayed on LCD and CRT Monitors. Presentation at ARRS, 2002, Atlanta, GA Siegel E, Reiner, B, Moffet, BR, et al.: Differences in Image Quality of CR Images Displayed on LCD and CRT Monitors. Presentation at ARRS, 2002, Atlanta, GA
9.
Zurück zum Zitat Siegel E, Reiner B, Moffet, BR, et al.: Differences in Image Quality of CR Images Displayed on LCD and CRT Monitors. Presentation at SCAR 2002, Cleveland, OH Siegel E, Reiner B, Moffet, BR, et al.: Differences in Image Quality of CR Images Displayed on LCD and CRT Monitors. Presentation at SCAR 2002, Cleveland, OH
10.
Zurück zum Zitat DeLong, ER, DeLong, DM, Clarke-Pearson, DL 1988Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approachBiometrics44837845PubMed DeLong, ER, DeLong, DM, Clarke-Pearson, DL 1988Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approachBiometrics44837845PubMed
11.
Zurück zum Zitat Cohen, J 1960A coefficient of agreement of nominal scalesEduc Psychol Measure203746 Cohen, J 1960A coefficient of agreement of nominal scalesEduc Psychol Measure203746
12.
Zurück zum Zitat Digital Imaging and Communications in Medicine, Part 14: Grayscale Standard Display Function, Rosslyn, VA: National Electrical Manufacturers Association, 2001 Digital Imaging and Communications in Medicine, Part 14: Grayscale Standard Display Function, Rosslyn, VA: National Electrical Manufacturers Association, 2001
14.
Zurück zum Zitat Wang, Z, Bovic, AC 2002A universal image quality indexIEEE Signal Process Lett38184CrossRef Wang, Z, Bovic, AC 2002A universal image quality indexIEEE Signal Process Lett38184CrossRef
Metadaten
Titel
SCAR R&D Symposium 2003: Comparing the Efficacy of 5-MP CRT Versus 3-MP LCD in the Evaluation of Interstitial Lung Disease
verfasst von
Steve Langer, PhD
Brian Bartholmai, MD
Ken Fetterly, MS
Scott Harmsen, PhD
William Ryan, MS
Brad Erickson, MD/PhD
Kathy Andriole, PhD
John Carrino, MD
Publikationsdatum
01.09.2004
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2004
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-004-1013-7

Weitere Artikel der Ausgabe 3/2004

Journal of Digital Imaging 3/2004 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.