Skip to main content
Erschienen in: Journal of Digital Imaging 3/2013

01.06.2013

Automated Estimation of Abdominal Effective Diameter for Body Size Normalization of CT Dose

verfasst von: Phillip M. Cheng

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 3/2013

Einloggen, um Zugang zu erhalten

Abstract

Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to −0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to −2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to −3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.
Literatur
1.
Zurück zum Zitat Cook TS, Zimmerman S, Maidment AD, Kim W, Boonn WW: Automated extraction of radiation dose information for CT examinations. J Am Coll Radiol 7:871–877, 2010PubMedCrossRef Cook TS, Zimmerman S, Maidment AD, Kim W, Boonn WW: Automated extraction of radiation dose information for CT examinations. J Am Coll Radiol 7:871–877, 2010PubMedCrossRef
2.
Zurück zum Zitat Li X, Zhang D, Liu B: Automated extraction of radiation dose information from CT dose report images. AJR Am J Roentgenol 196:W781–783, 2011PubMedCrossRef Li X, Zhang D, Liu B: Automated extraction of radiation dose information from CT dose report images. AJR Am J Roentgenol 196:W781–783, 2011PubMedCrossRef
3.
Zurück zum Zitat Morin RL, Coombs LP, Chatfield MB: ACR Dose Index Registry. J Am Coll Radiol 8:288–291, 2011PubMedCrossRef Morin RL, Coombs LP, Chatfield MB: ACR Dose Index Registry. J Am Coll Radiol 8:288–291, 2011PubMedCrossRef
4.
Zurück zum Zitat Cheng PM: Automated PACS retrieval and processing of dose data from legacy CT systems. American Roentgen Ray Society Annual Meeting, 2011 Cheng PM: Automated PACS retrieval and processing of dose data from legacy CT systems. American Roentgen Ray Society Annual Meeting, 2011
5.
Zurück zum Zitat McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF: CT dose index and patient dose: they are not the same thing. Radiology 259:311–316, 2011PubMedCrossRef McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF: CT dose index and patient dose: they are not the same thing. Radiology 259:311–316, 2011PubMedCrossRef
6.
Zurück zum Zitat American Association of Physicists in Medicine: Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations: Report of AAPM Task Group 204, College Park, MD, 2011 American Association of Physicists in Medicine: Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations: Report of AAPM Task Group 204, College Park, MD, 2011
7.
Zurück zum Zitat Kleinman PL, Strauss KJ, Zurakowski D, Buckley KS, Taylor GA: Patient size measured on CT images as a function of age at a tertiary care children’s hospital. AJR Am J Roentgenol 194:1611–1619, 2010PubMedCrossRef Kleinman PL, Strauss KJ, Zurakowski D, Buckley KS, Taylor GA: Patient size measured on CT images as a function of age at a tertiary care children’s hospital. AJR Am J Roentgenol 194:1611–1619, 2010PubMedCrossRef
8.
Zurück zum Zitat Menke J: Comparison of different body size parameters for individual dose adaptation in body CT of adults. Radiology 236:565–571, 2005PubMedCrossRef Menke J: Comparison of different body size parameters for individual dose adaptation in body CT of adults. Radiology 236:565–571, 2005PubMedCrossRef
9.
Zurück zum Zitat Zarb F, Rainford L, McEntee MF: AP diameter shows the strongest correlation with CTDI and DLP in abdominal and chest CT. Radiat Prot Dosimetry 140:266–273, 2010PubMedCrossRef Zarb F, Rainford L, McEntee MF: AP diameter shows the strongest correlation with CTDI and DLP in abdominal and chest CT. Radiat Prot Dosimetry 140:266–273, 2010PubMedCrossRef
Metadaten
Titel
Automated Estimation of Abdominal Effective Diameter for Body Size Normalization of CT Dose
verfasst von
Phillip M. Cheng
Publikationsdatum
01.06.2013
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2013
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-012-9525-z

Weitere Artikel der Ausgabe 3/2013

Journal of Digital Imaging 3/2013 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.