Quantitative bioimpedance spectroscopy for the assessment of lymphoedema

verfasst von: L. C. Ward, S. Czerniec, S. L. Kilbreath

Erschienen in: Breast Cancer Research and Treatment | Ausgabe 3/2009

Einloggen, um Zugang zu erhalten

Abstract

The aim was to make bioimpedance spectroscopy (BIS) quantitative for assessment of lymphoedema. Apparent resistivity coefficients were determined for the intra- and extracellular water of arms in a control cohort of women (n = 66). These coefficients were used to predict water volumes in the arms of women with lymphoedema (n = 23) and a separate control group without lymphoedema (n = 13) and to compare these with total arm size measured by perometry. Total arm volume was highly correlated (r = 0.80–0.90) with arm fluid volumes predicted by BIS and the proportional increase in arm size predicted by BIS was not significantly different to that measured by perometry. BIS predicted that the increased volume in the women with lymphoedema was predominantly (60%) due to increase in extracellular fluid. BIS is capable of quantifying the volume increase in limb size seen in lymphoedema.
Fußnoten
1
Tissue fluids contain dissolved solids, e.g. ∼6% in extracellular fluid [18]. Since measurement methods actually measure water volumes, we have used the terms TBW, ECW and ICW.
 
Literatur
1.
Zurück zum Zitat Petrek JA, Heelan MC (1998) Incidence of breast carcinoma-related lymphedema. Cancer 83:2776–2781. doi:10.1002/(SICI)1097-0142(19981215)83:12B+<2776::AID-CNCR25>3.0.CO;2-VPubMedCrossRef Petrek JA, Heelan MC (1998) Incidence of breast carcinoma-related lymphedema. Cancer 83:2776–2781. doi:10.1002/(SICI)1097-0142(19981215)83:12B+<2776::AID-CNCR25>3.0.CO;2-VPubMedCrossRef
2.
Zurück zum Zitat Meneses KD, McNees MP (2007) Upper extremity lymphedema after treatment for breast cancer: a review of the literature. Ostomy Wound Manage 53:16–29PubMed Meneses KD, McNees MP (2007) Upper extremity lymphedema after treatment for breast cancer: a review of the literature. Ostomy Wound Manage 53:16–29PubMed
4.
Zurück zum Zitat Sener SF, Winchester DJ, Martz CH et al (2001) Lymphedema after sentinel lymphadenectomy for breast carcinoma. Cancer 92:748–752. doi:10.1002/1097-0142(20010815)92:4<748::AID-CNCR1378>3.0.CO;2-VPubMedCrossRef Sener SF, Winchester DJ, Martz CH et al (2001) Lymphedema after sentinel lymphadenectomy for breast carcinoma. Cancer 92:748–752. doi:10.1002/1097-0142(20010815)92:4<748::AID-CNCR1378>3.0.CO;2-VPubMedCrossRef
7.
Zurück zum Zitat Petrek JA (2001) Lymphedema in a cohort of breast carcinoma survivors 20 years after diagnosis. Cancer 92:1368–1377. doi:10.1002/1097-0142(20010915)92:6<1368::AID-CNCR1459>3.0.CO;2-9PubMedCrossRef Petrek JA (2001) Lymphedema in a cohort of breast carcinoma survivors 20 years after diagnosis. Cancer 92:1368–1377. doi:10.1002/1097-0142(20010915)92:6<1368::AID-CNCR1459>3.0.CO;2-9PubMedCrossRef
8.
Zurück zum Zitat Szuba A, Rockson SG (1998) Lymphedema: classification, diagnosis and therapy. Vasc Med 3:145–156PubMed Szuba A, Rockson SG (1998) Lymphedema: classification, diagnosis and therapy. Vasc Med 3:145–156PubMed
9.
Zurück zum Zitat Sander AP, Hajer NM, Hemenway K et al (2002) Upper-extremity volume measurements in women with lymphedema: a comparison of measurements obtained via water displacement with geometrically determined volume. Phys Ther 82:1201–1212PubMed Sander AP, Hajer NM, Hemenway K et al (2002) Upper-extremity volume measurements in women with lymphedema: a comparison of measurements obtained via water displacement with geometrically determined volume. Phys Ther 82:1201–1212PubMed
12.
Zurück zum Zitat Cornish B, Chapman M, Hirst C et al (2001) Early diagnosis of lymphoedema using multiple frequency bioimpedance. Lymphology 34:2–11PubMed Cornish B, Chapman M, Hirst C et al (2001) Early diagnosis of lymphoedema using multiple frequency bioimpedance. Lymphology 34:2–11PubMed
15.
Zurück zum Zitat York SL, Ward LC, Czerniec S et al (2008) Single frequency versus bioimpedance spectroscopy for the assessment of lymphedema. Breast Cancer Res Treat. doi:10.1007/s10549-008-0090-6 York SL, Ward LC, Czerniec S et al (2008) Single frequency versus bioimpedance spectroscopy for the assessment of lymphedema. Breast Cancer Res Treat. doi:10.​1007/​s10549-008-0090-6
16.
17.
Zurück zum Zitat Ward LC, Kilbreath SL, Cornish BH (2008) Bioelectrical impedance analysis for early detection of lymphoedema. In: Weissleder H, Schuchhardt C (eds) Lymphedema Diagnosis and Therapy 4th edn. Viavital Verlag Gmbh Publ, Essen, pp 502–517 Ward LC, Kilbreath SL, Cornish BH (2008) Bioelectrical impedance analysis for early detection of lymphoedema. In: Weissleder H, Schuchhardt C (eds) Lymphedema Diagnosis and Therapy 4th edn. Viavital Verlag Gmbh Publ, Essen, pp 502–517
18.
Zurück zum Zitat Schoeller DA (1996) Hydrometry. In: Roche AF, Heymsfield SB, Lohman TG (eds) Human body composition, 1st edn. Human Kinetics, Champaign, pp 25–44 Schoeller DA (1996) Hydrometry. In: Roche AF, Heymsfield SB, Lohman TG (eds) Human body composition, 1st edn. Human Kinetics, Champaign, pp 25–44
19.
Zurück zum Zitat Stanton AW, Northfield JW, Holroyd B et al (1997) Validation of an optoelectronic limb volumeter (Perometer). Lymphology 30:77–97PubMed Stanton AW, Northfield JW, Holroyd B et al (1997) Validation of an optoelectronic limb volumeter (Perometer). Lymphology 30:77–97PubMed
20.
Zurück zum Zitat Johansson K, Ingvar C, Albertsson M et al (2001) Arm lymphoedema, shoulder mobility and muscle strength after breast cancer treatment—a prospective 2-year study. Adv Physiother 3:55–66CrossRef Johansson K, Ingvar C, Albertsson M et al (2001) Arm lymphoedema, shoulder mobility and muscle strength after breast cancer treatment—a prospective 2-year study. Adv Physiother 3:55–66CrossRef
26.
Zurück zum Zitat Pheasant S (1990) Body space anthropometry, ergonomics and the design of work. Taylor and Francis, London, UK Pheasant S (1990) Body space anthropometry, ergonomics and the design of work. Taylor and Francis, London, UK
27.
Zurück zum Zitat Isenring E, Ward LC, Bengston J et al (2007) Bioelectrical impedance spectroscopy (BIS) predicts limb composition compared with dual energy X-ray absorptiometry (DXA). Nutr Diet 65(Suppl 2):A7–A8 Isenring E, Ward LC, Bengston J et al (2007) Bioelectrical impedance spectroscopy (BIS) predicts limb composition compared with dual energy X-ray absorptiometry (DXA). Nutr Diet 65(Suppl 2):A7–A8
29.
Zurück zum Zitat Ward LC, Isenring E, Dyer J et al (2008) Constancy of resistivity coefficients for bioimpedance spectroscopy (BIS). Int J Body Compos Res 6:63–64 Ward LC, Isenring E, Dyer J et al (2008) Constancy of resistivity coefficients for bioimpedance spectroscopy (BIS). Int J Body Compos Res 6:63–64
Metadaten
Titel
Quantitative bioimpedance spectroscopy for the assessment of lymphoedema
verfasst von
L. C. Ward
S. Czerniec
S. L. Kilbreath
Publikationsdatum
01.10.2009
Verlag
Springer US
Erschienen in
Breast Cancer Research and Treatment / Ausgabe 3/2009
Print ISSN: 0167-6806
Elektronische ISSN: 1573-7217
DOI
https://doi.org/10.1007/s10549-008-0258-0

Weitere Artikel der Ausgabe 3/2009

Breast Cancer Research and Treatment 3/2009 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.