Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 2/2016

26.01.2016

Pulmonary vein anatomy assessed by cardiac magnetic resonance imaging in patients undergoing initial atrial fibrillation ablation: implications for novel ablation technologies

verfasst von: Faisal M. Merchant, Mathew R. Levy, Shahriar Iravanian, Edward C. Clermont, Heval M. Kelli, Robert L. Eisner, Mikhael F. El-Chami, Angel R. Leon, David B. Delurgio

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

Novel atrial fibrillation (AF) ablation tools have been designed to facilitate “single-shot” pulmonary vein (PV) isolation using multi-electrode or balloon-based catheters. However, in contrast to point-by-point radiofrequency ablation, these tools may be more dependent on suitable PV anatomy to achieve circumferential PV isolation.

Methods

Three hundred and twenty-two patients underwent gadolinium-enhanced cardiac magnetic resonance angiography to delineate PV anatomy prior to initial AF ablation. Long (a) and short (b) axis measurements of the PV orifice were used to calculate the eccentricity index of the PV ostium.

Results

Long axis dimensions of the left superior PV were 18.2 ± 3.3 mm, left inferior PV 17.7 ± 3.9 mm, right superior PV (RSPV) 20.4 ± 4.3, and right inferior PV 18.7 ± 4.7 mm. The long axis dimension of the RSPV was significantly larger than other PVs (p < 0.001). Forty-two patients (13 %) had at least one PV with a long axis dimension >25 mm and 16 patients (5 %) had at least one PV with a long axis dimension >28 mm. Left-sided PV ostia were significantly more ellipse-shaped than the right-sided PVs, which tended to be more spherical. A significant positive correlation was noted between increasing PV size and increased orifice eccentricity.

Conclusions

In this large cohort undergoing initial AF ablation, over 10 % of patients had at least one standard PV with a dimension >25 mm. Additionally, significant differences were noted between left- and right-sided veins with regard to orifice eccentricity. These findings have implications for the design of AF ablation tools and may account for differential isolation rates between PVs noted in some recent studies of novel ablation technologies.
Literatur
1.
Zurück zum Zitat Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., et al. (2010). Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation. Arrhythmia and Electrophysiology, 3(1), 32–38.CrossRefPubMed Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., et al. (2010). Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation. Arrhythmia and Electrophysiology, 3(1), 32–38.CrossRefPubMed
2.
Zurück zum Zitat Hummel, J., Michaud, G., Hoyt, R., DeLurgio, D., Rasekh, A., Kusumoto, F., et al. (2014). Phased RF ablation in persistent atrial fibrillation. Heart Rhythm, 11(2), 202–209.CrossRefPubMed Hummel, J., Michaud, G., Hoyt, R., DeLurgio, D., Rasekh, A., Kusumoto, F., et al. (2014). Phased RF ablation in persistent atrial fibrillation. Heart Rhythm, 11(2), 202–209.CrossRefPubMed
3.
Zurück zum Zitat Zellerhoff, S., Daly, M., Lim, H. S., Denis, A., Komatsu, Y., Jesel, L., et al. (2014). Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): a report on feasibility and efficacy. Europace, 16(9), 1296–1303.CrossRefPubMed Zellerhoff, S., Daly, M., Lim, H. S., Denis, A., Komatsu, Y., Jesel, L., et al. (2014). Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): a report on feasibility and efficacy. Europace, 16(9), 1296–1303.CrossRefPubMed
4.
Zurück zum Zitat Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., et al. (2013). Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. Journal of the American College of Cardiology, 61(16), 1713–1723.CrossRefPubMed Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., et al. (2013). Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. Journal of the American College of Cardiology, 61(16), 1713–1723.CrossRefPubMed
5.
Zurück zum Zitat Dukkipati, S. R., Woollett, I., Mc, E. H., Bohmer, M. C., Doshi, S. K., Gerstenfeld, E. P., et al. (2015). Pulmonary Vein Isolation Using the Visually Guided Laser Balloon: Results of the U.S. Feasibility Study. J Cardiovasc Electrophysiol, doi:10.1111/jce.12727 Dukkipati, S. R., Woollett, I., Mc, E. H., Bohmer, M. C., Doshi, S. K., Gerstenfeld, E. P., et al. (2015). Pulmonary Vein Isolation Using the Visually Guided Laser Balloon: Results of the U.S. Feasibility Study. J Cardiovasc Electrophysiol, doi:10.1111/jce.12727
6.
Zurück zum Zitat McLellan, A. J., Ling, L. H., Ruggiero, D., Wong, M. C., Walters, T. E., Nisbet, A., et al. (2014). Pulmonary vein isolation: the impact of pulmonary venous anatomy on long-term outcome of catheter ablation for paroxysmal atrial fibrillation. Heart Rhythm, 11(4), 549–556.CrossRefPubMed McLellan, A. J., Ling, L. H., Ruggiero, D., Wong, M. C., Walters, T. E., Nisbet, A., et al. (2014). Pulmonary vein isolation: the impact of pulmonary venous anatomy on long-term outcome of catheter ablation for paroxysmal atrial fibrillation. Heart Rhythm, 11(4), 549–556.CrossRefPubMed
7.
Zurück zum Zitat van der Voort, P. H., van den Bosch, H., Post, J. C., & Meijer, A. (2006). Determination of the spatial orientation and shape of pulmonary vein ostia by contrast-enhanced magnetic resonance angiography. Europace, 8(1), 1–6.CrossRefPubMed van der Voort, P. H., van den Bosch, H., Post, J. C., & Meijer, A. (2006). Determination of the spatial orientation and shape of pulmonary vein ostia by contrast-enhanced magnetic resonance angiography. Europace, 8(1), 1–6.CrossRefPubMed
8.
Zurück zum Zitat Thorning, C., Hamady, M., Liaw, J. V., Juli, C., Lim, P. B., Dhawan, R., et al. (2011). CT evaluation of pulmonary venous anatomy variation in patients undergoing catheter ablation for atrial fibrillation. Clinical Imaging, 35(1), 1–9.CrossRefPubMed Thorning, C., Hamady, M., Liaw, J. V., Juli, C., Lim, P. B., Dhawan, R., et al. (2011). CT evaluation of pulmonary venous anatomy variation in patients undergoing catheter ablation for atrial fibrillation. Clinical Imaging, 35(1), 1–9.CrossRefPubMed
9.
Zurück zum Zitat Mlcochova, H., Tintera, J., Porod, V., Peichl, P., Cihak, R., & Kautzner, J. (2005). Magnetic resonance angiography of pulmonary veins: implications for catheter ablation of atrial fibrillation. Pacing and Clinical Electrophysiology, 28(10), 1073–1080.CrossRefPubMed Mlcochova, H., Tintera, J., Porod, V., Peichl, P., Cihak, R., & Kautzner, J. (2005). Magnetic resonance angiography of pulmonary veins: implications for catheter ablation of atrial fibrillation. Pacing and Clinical Electrophysiology, 28(10), 1073–1080.CrossRefPubMed
10.
Zurück zum Zitat Mansour, M., Holmvang, G., Sosnovik, D., Migrino, R., Abbara, S., Ruskin, J., et al. (2004). Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: implications for catheter ablation techniques for atrial fibrillation. Journal of Cardiovascular Electrophysiology, 15(4), 387–393.CrossRefPubMed Mansour, M., Holmvang, G., Sosnovik, D., Migrino, R., Abbara, S., Ruskin, J., et al. (2004). Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: implications for catheter ablation techniques for atrial fibrillation. Journal of Cardiovascular Electrophysiology, 15(4), 387–393.CrossRefPubMed
11.
Zurück zum Zitat Scharf, C., Sneider, M., Case, I., Chugh, A., Lai, S. W., Pelosi, F., Jr., et al. (2003). Anatomy of the pulmonary veins in patients with atrial fibrillation and effects of segmental ostial ablation analyzed by computed tomography. Journal of Cardiovascular Electrophysiology, 14(2), 150–155.CrossRefPubMed Scharf, C., Sneider, M., Case, I., Chugh, A., Lai, S. W., Pelosi, F., Jr., et al. (2003). Anatomy of the pulmonary veins in patients with atrial fibrillation and effects of segmental ostial ablation analyzed by computed tomography. Journal of Cardiovascular Electrophysiology, 14(2), 150–155.CrossRefPubMed
12.
Zurück zum Zitat Ahmed, J., Sohal, S., Malchano, Z. J., Holmvang, G., Ruskin, J. N., & Reddy, V. Y. (2006). Three-dimensional analysis of pulmonary venous ostial and antral anatomy: implications for balloon catheter-based pulmonary vein isolation. Journal of Cardiovascular Electrophysiology, 17(3), 251–255.CrossRefPubMed Ahmed, J., Sohal, S., Malchano, Z. J., Holmvang, G., Ruskin, J. N., & Reddy, V. Y. (2006). Three-dimensional analysis of pulmonary venous ostial and antral anatomy: implications for balloon catheter-based pulmonary vein isolation. Journal of Cardiovascular Electrophysiology, 17(3), 251–255.CrossRefPubMed
13.
Zurück zum Zitat Merchant, F. M., & Delurgio, D. B. (2014). Catheter ablation of atrial fibrillation and risk of asymptomatic cerebral embolism. Pacing and Clinical Electrophysiology, 37(3), 389–397.CrossRefPubMed Merchant, F. M., & Delurgio, D. B. (2014). Catheter ablation of atrial fibrillation and risk of asymptomatic cerebral embolism. Pacing and Clinical Electrophysiology, 37(3), 389–397.CrossRefPubMed
14.
Zurück zum Zitat Tsyganov, A., Petru, J., Skoda, J., Sediva, L., Hala, P., Weichet, J., et al. (2015). Anatomical predictors for successful pulmonary vein isolation using balloon-based technologies in atrial fibrillation. J Interv Card Electrophysiol, doi:10.1007/s10840-015-0068-3 Tsyganov, A., Petru, J., Skoda, J., Sediva, L., Hala, P., Weichet, J., et al. (2015). Anatomical predictors for successful pulmonary vein isolation using balloon-based technologies in atrial fibrillation. J Interv Card Electrophysiol, doi:10.1007/s10840-015-0068-3
15.
Zurück zum Zitat Brunelli, M., Raffa, S., Grosse, A., Wauters, K., Menoni, S., Schreiber, M., et al. (2012). Influence of the anatomic characteristics of the pulmonary vein ostium, the learning curve, and the use of a steerable sheath on success of pulmonary vein isolation with a novel multielectrode ablation catheter. Europace, 14(3), 331–340.CrossRefPubMed Brunelli, M., Raffa, S., Grosse, A., Wauters, K., Menoni, S., Schreiber, M., et al. (2012). Influence of the anatomic characteristics of the pulmonary vein ostium, the learning curve, and the use of a steerable sheath on success of pulmonary vein isolation with a novel multielectrode ablation catheter. Europace, 14(3), 331–340.CrossRefPubMed
16.
Zurück zum Zitat Guler, E., Guler, G. B., Demir, G. G., Kizilirmak, F., Gunes, H. M., Barutcu, I., et al. (2015). Effect of pulmonary vein anatomy and pulmonary vein diameters on outcome of cryoballoon catheter ablation for atrial fibrillation. Pacing and Clinical Electrophysiology, 38(8), 989–996.CrossRefPubMed Guler, E., Guler, G. B., Demir, G. G., Kizilirmak, F., Gunes, H. M., Barutcu, I., et al. (2015). Effect of pulmonary vein anatomy and pulmonary vein diameters on outcome of cryoballoon catheter ablation for atrial fibrillation. Pacing and Clinical Electrophysiology, 38(8), 989–996.CrossRefPubMed
17.
Zurück zum Zitat Heeger, C. H., Wissner, E., Mathew, S., Deiss, S., Lemes, C., Rillig, A., et al. (2015). Once isolated, always isolated? Incidence and characteristics of pulmonary vein reconduction after second-generation cryoballoon-based pulmonary vein isolation. Circulation. Arrhythmia and Electrophysiology, 8(5), 1088–1094.CrossRefPubMed Heeger, C. H., Wissner, E., Mathew, S., Deiss, S., Lemes, C., Rillig, A., et al. (2015). Once isolated, always isolated? Incidence and characteristics of pulmonary vein reconduction after second-generation cryoballoon-based pulmonary vein isolation. Circulation. Arrhythmia and Electrophysiology, 8(5), 1088–1094.CrossRefPubMed
18.
Zurück zum Zitat Andrade, J. G., Khairy, P., Macle, L., Packer, D. L., Lehmann, J. W., Holcomb, R. G., et al. (2014). Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial. Circulation. Arrhythmia and Electrophysiology, 7(1), 69–75.CrossRefPubMed Andrade, J. G., Khairy, P., Macle, L., Packer, D. L., Lehmann, J. W., Holcomb, R. G., et al. (2014). Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial. Circulation. Arrhythmia and Electrophysiology, 7(1), 69–75.CrossRefPubMed
19.
Zurück zum Zitat Metzner, A., Kivelitz, D., Schmidt, B., Fuernkranz, A., Wissner, E., Tilz, R. R., et al. (2012). Impact of pulmonary vein anatomy assessed by cardiac magnetic resonance imaging on endoscopic pulmonary vein isolation in consecutive patients. Europace, 14(4), 474–480.CrossRefPubMed Metzner, A., Kivelitz, D., Schmidt, B., Fuernkranz, A., Wissner, E., Tilz, R. R., et al. (2012). Impact of pulmonary vein anatomy assessed by cardiac magnetic resonance imaging on endoscopic pulmonary vein isolation in consecutive patients. Europace, 14(4), 474–480.CrossRefPubMed
Metadaten
Titel
Pulmonary vein anatomy assessed by cardiac magnetic resonance imaging in patients undergoing initial atrial fibrillation ablation: implications for novel ablation technologies
verfasst von
Faisal M. Merchant
Mathew R. Levy
Shahriar Iravanian
Edward C. Clermont
Heval M. Kelli
Robert L. Eisner
Mikhael F. El-Chami
Angel R. Leon
David B. Delurgio
Publikationsdatum
26.01.2016
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 2/2016
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-016-0106-9

Weitere Artikel der Ausgabe 2/2016

Journal of Interventional Cardiac Electrophysiology 2/2016 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.