Skip to main content
Erschienen in: Journal of Thrombosis and Thrombolysis 4/2015

01.11.2015

In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices

verfasst von: Gaurav Girdhar, Junwei Li, Larisa Kostousov, John Wainwright, Wayne L. Chandler

Erschienen in: Journal of Thrombosis and Thrombolysis | Ausgabe 4/2015

Einloggen, um Zugang zu erhalten

Abstract

Endoluminal devices such as metallic flow diversion (FD) and aneurysm bridging (AB) stents are used for treatment of intracranial aneurysms. Treatments are associated with thrombogenic events mandating the use of dual antiplatelet therapy in all cases. In the current in vitro study, we utilize a slow binding fluorogenic thrombin specific substrate to measure the thrombin generation potential of six devices: four FD devices (Pipeline™ Flex embolization device, Pipeline™ Flex embolization device with Shield Technology™, SILK+, FRED™) and two AB devices (Solitaire™ AB, LEO+). We show that the Pipeline™ Flex embolization device with Shield Technology™ has significantly lower peak thrombin and takes significantly longer time to achieve peak thrombin (time to peak) compared to the other three FD devices (p < 0.05), with statistically similar results to the less thrombogenic AB devices. We conclude that surface modification of endoluminal stents could be an effective method to mitigate thrombogenic complications.
Literatur
1.
Zurück zum Zitat Starke RM, Turk A, Ding D, Crowley RW, Liu KC, Chalouhi N, Hasan DM, Dumont AS, Jabbour P, Durst CR, Turner RD (2014) Technology developments in endovascular treatment of intracranial aneurysms. J Neurointerv Surg. doi:10.1136/neurintsurg-2014-011475 Starke RM, Turk A, Ding D, Crowley RW, Liu KC, Chalouhi N, Hasan DM, Dumont AS, Jabbour P, Durst CR, Turner RD (2014) Technology developments in endovascular treatment of intracranial aneurysms. J Neurointerv Surg. doi:10.​1136/​neurintsurg-2014-011475
7.
Zurück zum Zitat Kallmes DF, Hanel R, Lopes D, Boccardi E, Bonafe A, Cekirge S, Fiorella D, Jabbour P, Levy E, McDougall C, Siddiqui A, Szikora I, Woo H, Albuquerque F, Bozorgchami H, Dashti SR, Delgado Almandoz JE, Kelly ME, Turner R, Woodward BK, Brinjikji W, Lanzino G, Lylyk P (2015) International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study. Am J Neuroradiol 36(1):108–115. doi:10.3174/ajnr.A4111 CrossRefPubMed Kallmes DF, Hanel R, Lopes D, Boccardi E, Bonafe A, Cekirge S, Fiorella D, Jabbour P, Levy E, McDougall C, Siddiqui A, Szikora I, Woo H, Albuquerque F, Bozorgchami H, Dashti SR, Delgado Almandoz JE, Kelly ME, Turner R, Woodward BK, Brinjikji W, Lanzino G, Lylyk P (2015) International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study. Am J Neuroradiol 36(1):108–115. doi:10.​3174/​ajnr.​A4111 CrossRefPubMed
8.
9.
Zurück zum Zitat Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, Cher DJ, Siddiqui AH, Levy EI, Albuquerque FC, Fiorella DJ, Berentei Z, Marosfoi M, Cekirge SH, Nelson PK (2013) Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology 267(3):858–868. doi:10.1148/radiol.13120099 CrossRefPubMed Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, Cher DJ, Siddiqui AH, Levy EI, Albuquerque FC, Fiorella DJ, Berentei Z, Marosfoi M, Cekirge SH, Nelson PK (2013) Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology 267(3):858–868. doi:10.​1148/​radiol.​13120099 CrossRefPubMed
10.
Zurück zum Zitat Lewis AL, Stratford PW (2002) Phosphorylcholine-coated stents. J Long Term Eff Med Implants 12(4):231–250CrossRefPubMed Lewis AL, Stratford PW (2002) Phosphorylcholine-coated stents. J Long Term Eff Med Implants 12(4):231–250CrossRefPubMed
11.
Zurück zum Zitat Whelan DM, van der Giessen WJ, Krabbendam SC, van Vliet EA, Verdouw PD, Serruys PW, van Beusekom HM (2000) Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries. Heart 83(3):338–345PubMedCentralCrossRefPubMed Whelan DM, van der Giessen WJ, Krabbendam SC, van Vliet EA, Verdouw PD, Serruys PW, van Beusekom HM (2000) Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries. Heart 83(3):338–345PubMedCentralCrossRefPubMed
12.
Zurück zum Zitat Kuiper KK, Robinson KA, Chronos NA, Cui J, Palmer SJ, Nordrehaug JE (1998) Phosphorylcholine-coated metallic stents in rabbit iliac and porcine coronary arteries. Scand Cardiovasc J 32(5):261–268CrossRefPubMed Kuiper KK, Robinson KA, Chronos NA, Cui J, Palmer SJ, Nordrehaug JE (1998) Phosphorylcholine-coated metallic stents in rabbit iliac and porcine coronary arteries. Scand Cardiovasc J 32(5):261–268CrossRefPubMed
13.
Zurück zum Zitat Chen C, Lumsden AB, Ofenloch JC, Noe B, Campbell EJ, Stratford PW, Yianni YP, Taylor AS, Hanson SR (1997) Phosphorylcholine coating of ePTFE grafts reduces neointimal hyperplasia in canine model. Ann Vasc Surg 11(1):74–79. doi:10.1007/s100169900013 CrossRefPubMed Chen C, Lumsden AB, Ofenloch JC, Noe B, Campbell EJ, Stratford PW, Yianni YP, Taylor AS, Hanson SR (1997) Phosphorylcholine coating of ePTFE grafts reduces neointimal hyperplasia in canine model. Ann Vasc Surg 11(1):74–79. doi:10.​1007/​s100169900013 CrossRefPubMed
14.
16.
Zurück zum Zitat van Hylckama Vlieg A, Christiansen SC, Luddington R, Cannegieter SC, Rosendaal FR, Baglin TP (2007) Elevated endogenous thrombin potential is associated with an increased risk of a first deep venous thrombosis but not with the risk of recurrence. Br J Haematol 138(6):769–774. doi:10.1111/j.1365-2141.2007.06738.x CrossRef van Hylckama Vlieg A, Christiansen SC, Luddington R, Cannegieter SC, Rosendaal FR, Baglin TP (2007) Elevated endogenous thrombin potential is associated with an increased risk of a first deep venous thrombosis but not with the risk of recurrence. Br J Haematol 138(6):769–774. doi:10.​1111/​j.​1365-2141.​2007.​06738.​x CrossRef
18.
Zurück zum Zitat Hemker HC, Beguin S (1995) Thrombin generation in plasma: its assessment via the endogenous thrombin potential. Thromb Haemost 74(1):134–138PubMed Hemker HC, Beguin S (1995) Thrombin generation in plasma: its assessment via the endogenous thrombin potential. Thromb Haemost 74(1):134–138PubMed
19.
Zurück zum Zitat Hemker HC, Giesen P, Al Dieri R, Regnault V, de Smedt E, Wagenvoord R, Lecompte T, Beguin S (2003) Calibrated automated thrombin generation measurement in clotting plasma. Pathophysiol Haemost Thromb 33(1):4–15CrossRefPubMed Hemker HC, Giesen P, Al Dieri R, Regnault V, de Smedt E, Wagenvoord R, Lecompte T, Beguin S (2003) Calibrated automated thrombin generation measurement in clotting plasma. Pathophysiol Haemost Thromb 33(1):4–15CrossRefPubMed
20.
Zurück zum Zitat Hemker HC, Willems GM, Beguin S (1986) A computer assisted method to obtain the prothrombin activation velocity in whole plasma independent of thrombin decay processes. Thromb Haemost 56(1):9–17PubMed Hemker HC, Willems GM, Beguin S (1986) A computer assisted method to obtain the prothrombin activation velocity in whole plasma independent of thrombin decay processes. Thromb Haemost 56(1):9–17PubMed
23.
Zurück zum Zitat Nelson PK, Lylyk P, Szikora I, Wetzel SG, Wanke I, Fiorella D (2011) The pipeline embolization device for the intracranial treatment of aneurysms trial. Am J Neuroradiol 32(1):34–40. doi:10.3174/ajnr.A2421 PubMed Nelson PK, Lylyk P, Szikora I, Wetzel SG, Wanke I, Fiorella D (2011) The pipeline embolization device for the intracranial treatment of aneurysms trial. Am J Neuroradiol 32(1):34–40. doi:10.​3174/​ajnr.​A2421 PubMed
24.
Zurück zum Zitat Krischek O, Miloslavski E, Fischer S, Shrivastava S, Henkes H (2011) A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise]. Minim Invasive Neurosurg 54(1):21–28. doi:10.1055/s-0031-1271681 CrossRefPubMed Krischek O, Miloslavski E, Fischer S, Shrivastava S, Henkes H (2011) A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise]. Minim Invasive Neurosurg 54(1):21–28. doi:10.​1055/​s-0031-1271681 CrossRefPubMed
25.
26.
Zurück zum Zitat Delgado Almandoz JE, Crandall BM, Scholz JM, Fease JL, Anderson RE, Kadkhodayan Y, Tubman DE (2014) Last-recorded P2Y12 reaction units value is strongly associated with thromboembolic and hemorrhagic complications occurring up to 6 months after treatment in patients with cerebral aneurysms treated with the pipeline embolization device. Am J Neuroradiol 35(1):128–135. doi:10.3174/ajnr.A3621 CrossRefPubMed Delgado Almandoz JE, Crandall BM, Scholz JM, Fease JL, Anderson RE, Kadkhodayan Y, Tubman DE (2014) Last-recorded P2Y12 reaction units value is strongly associated with thromboembolic and hemorrhagic complications occurring up to 6 months after treatment in patients with cerebral aneurysms treated with the pipeline embolization device. Am J Neuroradiol 35(1):128–135. doi:10.​3174/​ajnr.​A3621 CrossRefPubMed
Metadaten
Titel
In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices
verfasst von
Gaurav Girdhar
Junwei Li
Larisa Kostousov
John Wainwright
Wayne L. Chandler
Publikationsdatum
01.11.2015
Verlag
Springer US
Erschienen in
Journal of Thrombosis and Thrombolysis / Ausgabe 4/2015
Print ISSN: 0929-5305
Elektronische ISSN: 1573-742X
DOI
https://doi.org/10.1007/s11239-015-1228-0

Weitere Artikel der Ausgabe 4/2015

Journal of Thrombosis and Thrombolysis 4/2015 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.