Skip to main content
Erschienen in: Obesity Surgery 1/2012

01.01.2012 | Clinical Research

Reinforcing the Staple Line During Laparoscopic Sleeve Gastrectomy: Prospective Randomized Clinical Study Comparing Two Different Techniques. Preliminary results

verfasst von: Konstantinos Albanopoulos, Leonidas Alevizos, John Flessas, Evangelos Menenakos, Konstantinos M. Stamou, Joanna Papailiou, Maria Natoudi, George Zografos, Emmanuel Leandros

Erschienen in: Obesity Surgery | Ausgabe 1/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

Sleeve gastrectomy involves the creation of small gastric reservoir based on lesser curvature of the stomach, which is fashioned by a longitudinal gastrectomy that preserves the antrum and pylorus together with its vagal innervation. The main complications in the early postoperative course are bleeding and gastric leak. In order to reduce these complications the staple line can be reinforced in many different ways. The purpose of this study was to randomly compare two different techniques in laparoscopic sleeve gastrectomy (LSG): buttressing the staple line at the gastroesophageal junction (angle of Hiss) with Gore Seamguard and staple-line suturing with PDS 2.0.

Methods

Between July 2009 and July 2010, 90 patients were prospectively and randomly enrolled in the two different techniques of handling the staple line during LSG. Forty-eight of these patients belonged in group A (application of Gore Seamguard) and 42 in group B (application of a continuous suture). Operative and postoperative complications were recorded.

Results

Postoperative leak affected two patients in group A (4.2%) and bleeding occurred in one patient of group A (2%). Total complication rate was 6.2% for group A. No major surgical complication occurred in group B. The differences between the two groups did not reach statistical significance.

Conclusions

No significant difference is evidenced in terms of bleeding and postoperative leak between the two techniques of enhancing the staple line in LSG. Suturing of the staple line may be more time consuming but costs are considerably less.
Literatur
1.
Zurück zum Zitat Deitel M, Crosby RD, Gagner M. The First International Consensus Summit for Sleeve Gastrectomy (SG), New York City, October 25–27, 2007. Obes Surg. 2008;8:87–96. Deitel M, Crosby RD, Gagner M. The First International Consensus Summit for Sleeve Gastrectomy (SG), New York City, October 25–27, 2007. Obes Surg. 2008;8:87–96.
2.
Zurück zum Zitat Gagner M, Deitel M, Kalberer TL, et al. The second International Consensus Summit for Sleeve Gastrectomy, March 19–21, 2009. Surg Obes Relat Dis. 2009;5:476–85.PubMedCrossRef Gagner M, Deitel M, Kalberer TL, et al. The second International Consensus Summit for Sleeve Gastrectomy, March 19–21, 2009. Surg Obes Relat Dis. 2009;5:476–85.PubMedCrossRef
3.
Zurück zum Zitat Brethauer SA, Hammel JP, Schauer PR. Systematic review of sleeve gastrectomy as staging and primary bariatric procedure. Surg Obes Relat Dis. 2009;5:469–75.PubMedCrossRef Brethauer SA, Hammel JP, Schauer PR. Systematic review of sleeve gastrectomy as staging and primary bariatric procedure. Surg Obes Relat Dis. 2009;5:469–75.PubMedCrossRef
4.
Zurück zum Zitat Nocca D, Krawczykowsky D, Bomans B, et al. A prospective multicenter study of 163 sleeve gastrectomies: results at 1 and 2 years. Obes Surg. 2008;18:560–5.PubMedCrossRef Nocca D, Krawczykowsky D, Bomans B, et al. A prospective multicenter study of 163 sleeve gastrectomies: results at 1 and 2 years. Obes Surg. 2008;18:560–5.PubMedCrossRef
5.
Zurück zum Zitat Serra C, Baltasar A, Andreo L, et al. Treatment of gastric leaks with coated self-expanding stents after sleeve gastrectomy. Obes Surg. 2007;17:866–72.PubMedCrossRef Serra C, Baltasar A, Andreo L, et al. Treatment of gastric leaks with coated self-expanding stents after sleeve gastrectomy. Obes Surg. 2007;17:866–72.PubMedCrossRef
6.
Zurück zum Zitat Casella G, Soricelli E, Rizzello M, et al. Nonsurgical treatment of staple line leaks after laparoscopic sleeve gastrectomy. Obes Surg. 2009;19:821–6.PubMedCrossRef Casella G, Soricelli E, Rizzello M, et al. Nonsurgical treatment of staple line leaks after laparoscopic sleeve gastrectomy. Obes Surg. 2009;19:821–6.PubMedCrossRef
7.
Zurück zum Zitat Dapri G, Vaz C, Cadière GB, et al. A prospective randomized study comparing two different techniques for laparoscopic sleeve gastrectomy. Obes Surg. 2007;17:1435–41.PubMedCrossRef Dapri G, Vaz C, Cadière GB, et al. A prospective randomized study comparing two different techniques for laparoscopic sleeve gastrectomy. Obes Surg. 2007;17:1435–41.PubMedCrossRef
8.
Zurück zum Zitat Albanopoulos K, Alevizos L, Linardoutsos D, et al. Routine abdominal drains after laparoscopic sleeve gastrectomy: a retrospective review of 353 patients. Obes Surg. 2010. doi:10.1007/s11695-010-0343-4. Albanopoulos K, Alevizos L, Linardoutsos D, et al. Routine abdominal drains after laparoscopic sleeve gastrectomy: a retrospective review of 353 patients. Obes Surg. 2010. doi:10.​1007/​s11695-010-0343-4.
9.
Zurück zum Zitat Baltasar A, Bou R, Bengochea M, et al. Use of a Roux limb to correct esophagogastric junction fistula after sleeve gastrectomy. Obes Surg. 2007;17:1408–10.PubMedCrossRef Baltasar A, Bou R, Bengochea M, et al. Use of a Roux limb to correct esophagogastric junction fistula after sleeve gastrectomy. Obes Surg. 2007;17:1408–10.PubMedCrossRef
10.
Zurück zum Zitat Consten ECJ, Gagner M, Pomp A, et al. Decreased bleeding after laparoscopic sleeve gastrectomy with or without duodenal switch for morbid obesity using a stapled buttresses absorbable polymer membrane. Obes Surg. 2004;14:1360–6.PubMedCrossRef Consten ECJ, Gagner M, Pomp A, et al. Decreased bleeding after laparoscopic sleeve gastrectomy with or without duodenal switch for morbid obesity using a stapled buttresses absorbable polymer membrane. Obes Surg. 2004;14:1360–6.PubMedCrossRef
11.
Zurück zum Zitat Yehoshua RT, Eidelman LA, Stein M, et al. Laparoscopic sleeve gastrectomy-volume and pressure assessment. Obes Surg. 2008;18:1083–8.PubMedCrossRef Yehoshua RT, Eidelman LA, Stein M, et al. Laparoscopic sleeve gastrectomy-volume and pressure assessment. Obes Surg. 2008;18:1083–8.PubMedCrossRef
12.
Zurück zum Zitat Kasalicky M, Michalsky D, Housova J, et al. Laparoscopic sleeve gastrectomy without an over-sewing of the staple line. Obes Surg. 2008;18:1257–62.PubMedCrossRef Kasalicky M, Michalsky D, Housova J, et al. Laparoscopic sleeve gastrectomy without an over-sewing of the staple line. Obes Surg. 2008;18:1257–62.PubMedCrossRef
13.
Zurück zum Zitat Miller KA, Pump A. Use of bioabsorbable staple reinforcement material in gastric bypass: a prospective randomized clinical trial. Surg Obes Relat Dis. 2007;3:417–22.PubMedCrossRef Miller KA, Pump A. Use of bioabsorbable staple reinforcement material in gastric bypass: a prospective randomized clinical trial. Surg Obes Relat Dis. 2007;3:417–22.PubMedCrossRef
14.
Zurück zum Zitat Shikora SA, Kim JJ, Tarnoff ME. Comparison of permanent and nonpermanent staple line buttressing materials for linear gastric staple lines during laparoscopic Roux-en-Y gastric bypass. Surg Obes Relat Dis. 2008;4:729–34.PubMedCrossRef Shikora SA, Kim JJ, Tarnoff ME. Comparison of permanent and nonpermanent staple line buttressing materials for linear gastric staple lines during laparoscopic Roux-en-Y gastric bypass. Surg Obes Relat Dis. 2008;4:729–34.PubMedCrossRef
15.
Zurück zum Zitat Angrisani L, Lorenzo M, Borrelli V, et al. The use of bovine pericardial strips on linear stapler to reduce extraluminal bleeding during laparoscopic gastric bypass: prospective randomized clinical trial. Obes Surg. 2004;14:1198–202.PubMedCrossRef Angrisani L, Lorenzo M, Borrelli V, et al. The use of bovine pericardial strips on linear stapler to reduce extraluminal bleeding during laparoscopic gastric bypass: prospective randomized clinical trial. Obes Surg. 2004;14:1198–202.PubMedCrossRef
16.
Zurück zum Zitat Chen B, Kiriakopoulos A, Tsakayannis D. Reinforcement does not necessarily reduce the rate of staple line leaks after sleeve gastrectomy. A review of the literature and clinical experiences. Obes Surg. 2009;19:166–72.PubMedCrossRef Chen B, Kiriakopoulos A, Tsakayannis D. Reinforcement does not necessarily reduce the rate of staple line leaks after sleeve gastrectomy. A review of the literature and clinical experiences. Obes Surg. 2009;19:166–72.PubMedCrossRef
17.
Zurück zum Zitat Baker RS, Foote J, Kemmeter P, et al. The science of stapling and leaks. Obes Surg. 2004;14:1290–8.PubMedCrossRef Baker RS, Foote J, Kemmeter P, et al. The science of stapling and leaks. Obes Surg. 2004;14:1290–8.PubMedCrossRef
18.
Zurück zum Zitat Pinheiro JS, Correa JL, Cohen RV, et al. Staple line reinforcement with new biomaterial increased burst strength pressure: an animal study. Surg Obes Relat Dis. 2006;2:397–9.PubMedCrossRef Pinheiro JS, Correa JL, Cohen RV, et al. Staple line reinforcement with new biomaterial increased burst strength pressure: an animal study. Surg Obes Relat Dis. 2006;2:397–9.PubMedCrossRef
19.
Zurück zum Zitat Downey DM, Harre JG, Dolan JP. Increased burst pressure in gastrointestinal staple-lines using reinforcement with a bioprosthetic material. Obes Surg. 2005;15:1379–83.PubMedCrossRef Downey DM, Harre JG, Dolan JP. Increased burst pressure in gastrointestinal staple-lines using reinforcement with a bioprosthetic material. Obes Surg. 2005;15:1379–83.PubMedCrossRef
20.
Zurück zum Zitat Ser KH, Lee WJ, Lee YC, Chen JC, et al. Experience in laparoscopic sleeve gastrectomy for morbidly obese Taiwanese: staple-line reinforcement is important for preventing leakage. Surg Endosc. 2010;24:2253–9.PubMedCrossRef Ser KH, Lee WJ, Lee YC, Chen JC, et al. Experience in laparoscopic sleeve gastrectomy for morbidly obese Taiwanese: staple-line reinforcement is important for preventing leakage. Surg Endosc. 2010;24:2253–9.PubMedCrossRef
Metadaten
Titel
Reinforcing the Staple Line During Laparoscopic Sleeve Gastrectomy: Prospective Randomized Clinical Study Comparing Two Different Techniques. Preliminary results
verfasst von
Konstantinos Albanopoulos
Leonidas Alevizos
John Flessas
Evangelos Menenakos
Konstantinos M. Stamou
Joanna Papailiou
Maria Natoudi
George Zografos
Emmanuel Leandros
Publikationsdatum
01.01.2012
Verlag
Springer-Verlag
Erschienen in
Obesity Surgery / Ausgabe 1/2012
Print ISSN: 0960-8923
Elektronische ISSN: 1708-0428
DOI
https://doi.org/10.1007/s11695-011-0421-2

Weitere Artikel der Ausgabe 1/2012

Obesity Surgery 1/2012 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.