Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 3/2008

01.03.2008 | Original Article

Does Ion Release Differ Between Hip Resurfacing and Metal-on-metal THA?

verfasst von: Antonio Moroni, MD, Lucia Savarino, BSc, Matteo Cadossi, MD, Nicola Baldini, MD, Sandro Giannini, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 3/2008

Einloggen, um Zugang zu erhalten

Abstract

Modern metal-on-metal hip resurfacing was introduced as a bone-preserving method of joint reconstruction for young and active patients; however, the large diameter of the bearing surfaces is of concern for potential increased metal ion release. We hypothesized there were no differences in serum concentrations of chromium, cobalt, and molybdenum between patients who had metal-on-metal hip resurfacing (Group A; average head diameter, 48 mm; median followup, 24 months) and patients who had 28-mm metal-on-metal THA (Group B; median followup, 25 months). Serum concentrations also were compared with concentrations in healthy subjects. We identified no differences in ion levels between Groups A and B. A distinction was made according to gender. Women showed a higher chromium release in Group A whereas men had a higher cobalt release in Group B. Values obtained from Group A were higher than those of the control subjects. Our data suggest metal-on-metal bearings for THA should not be rejected because of concern regarding potential increased metal ion release; however, patients with elevated ion levels, even without loosening or toxicity, could be at higher risk and should be followed up periodically.
Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Back DL, Young DA, Shimmin AJ. How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Clin Orthop Relat Res. 2005;438:177–181.PubMedCrossRef Back DL, Young DA, Shimmin AJ. How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Clin Orthop Relat Res. 2005;438:177–181.PubMedCrossRef
2.
Zurück zum Zitat Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R. Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am. 2003;85:2168–2173.PubMed Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R. Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am. 2003;85:2168–2173.PubMed
3.
Zurück zum Zitat Brodner W, Grübl A, Jankovsky R, Meisinger V, Lehr S, Gottsauner-Wolf F. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty. 2004;19(8 suppl 3):66–70.PubMedCrossRef Brodner W, Grübl A, Jankovsky R, Meisinger V, Lehr S, Gottsauner-Wolf F. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty. 2004;19(8 suppl 3):66–70.PubMedCrossRef
4.
Zurück zum Zitat Butcher DJ, Sneddon J. A practical guide to graphite furnace atomic absorption spectrometry. In: Winefordner JD, ed. Chemical Analysis: A Series of Monographs on Analytical Chemistry and Its Applications. New York, NY: Wiley; 1998. Butcher DJ, Sneddon J. A practical guide to graphite furnace atomic absorption spectrometry. In: Winefordner JD, ed. Chemical Analysis: A Series of Monographs on Analytical Chemistry and Its Applications. New York, NY: Wiley; 1998.
5.
Zurück zum Zitat Clarke MT, Lee PT, Arora A, Villar RN. Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. J Bone Joint Surg Br. 2003;85:913–917.PubMed Clarke MT, Lee PT, Arora A, Villar RN. Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. J Bone Joint Surg Br. 2003;85:913–917.PubMed
6.
Zurück zum Zitat Daniel J, Ziaee H, Salama A, Pradhan C, McMinn DJ. The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium. J Bone Joint Surg Br. 2006;88:443–448.PubMedCrossRef Daniel J, Ziaee H, Salama A, Pradhan C, McMinn DJ. The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium. J Bone Joint Surg Br. 2006;88:443–448.PubMedCrossRef
7.
Zurück zum Zitat dela Rosa MA, Silva M, Heisel C, Reich M, Schmalzried TP. Range of motion after total hip resurfacing. Orthopedics. 2007;30:352–357.PubMed dela Rosa MA, Silva M, Heisel C, Reich M, Schmalzried TP. Range of motion after total hip resurfacing. Orthopedics. 2007;30:352–357.PubMed
8.
Zurück zum Zitat Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res. 1998;42:103–111.PubMedCrossRef Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res. 1998;42:103–111.PubMedCrossRef
9.
Zurück zum Zitat Dorr LD, Kane TJ 3rd, Conaty JP. Long-term results of cemented total hip arthroplasty in patients 45 years old or younger: a 16 year follow-up study. J Arthroplasty. 1994;9:453–456.PubMedCrossRef Dorr LD, Kane TJ 3rd, Conaty JP. Long-term results of cemented total hip arthroplasty in patients 45 years old or younger: a 16 year follow-up study. J Arthroplasty. 1994;9:453–456.PubMedCrossRef
10.
Zurück zum Zitat Dumbleton JH, Manley MT. Metal-on-metal total hip replacement: what does the literature say? J Arthroplasty. 2005;20:174–188.PubMedCrossRef Dumbleton JH, Manley MT. Metal-on-metal total hip replacement: what does the literature say? J Arthroplasty. 2005;20:174–188.PubMedCrossRef
11.
Zurück zum Zitat Granchi D, Cenni E, Ciapetti G, Savarino L, Stea S, Gamberini S, Gori A, Pizzoferrato A. Cell death induced by metal ions: necrosis or apoptosis? J Mater Sci Mater Med. 1998;9:31–37.PubMedCrossRef Granchi D, Cenni E, Ciapetti G, Savarino L, Stea S, Gamberini S, Gori A, Pizzoferrato A. Cell death induced by metal ions: necrosis or apoptosis? J Mater Sci Mater Med. 1998;9:31–37.PubMedCrossRef
12.
Zurück zum Zitat Granchi D, Ciapetti G, Savarino L, Stea S, Filippini F, Sudanese A, Rotini R, Giunti A. Expression of the CD69 activation antigen on lymphocytes of patients with hip prosthesis. Biomaterials. 2000;21:2059–2065.PubMedCrossRef Granchi D, Ciapetti G, Savarino L, Stea S, Filippini F, Sudanese A, Rotini R, Giunti A. Expression of the CD69 activation antigen on lymphocytes of patients with hip prosthesis. Biomaterials. 2000;21:2059–2065.PubMedCrossRef
13.
Zurück zum Zitat Granchi D, Ciapetti G, Stea S, Savarino L, Filippini F, Sudanese A, Zinghi GF, Montanaro L. Cytokine release in mononuclear cells of patients with Co-Cr hip prosthesis. Biomaterials. 1999;20:1079–1086.PubMedCrossRef Granchi D, Ciapetti G, Stea S, Savarino L, Filippini F, Sudanese A, Zinghi GF, Montanaro L. Cytokine release in mononuclear cells of patients with Co-Cr hip prosthesis. Biomaterials. 1999;20:1079–1086.PubMedCrossRef
14.
Zurück zum Zitat Granchi D, Savarino L, Ciapetti G, Cenni E, Rotini R, Mieti M, Baldini N, Giunti A. Immunological changes in patients with total joint replacement following idiopathic osteoarthritis of the hip. J Bone Joint Surg Br. 2003;85:758–764.PubMed Granchi D, Savarino L, Ciapetti G, Cenni E, Rotini R, Mieti M, Baldini N, Giunti A. Immunological changes in patients with total joint replacement following idiopathic osteoarthritis of the hip. J Bone Joint Surg Br. 2003;85:758–764.PubMed
15.
Zurück zum Zitat Granchi D, Verri E, Ciapetti G, Stea S, Savarino L, Sudanese A, Mieti M, Rotini R, Dallari D, Zinghi G, Montanaro L. Bone resorbing cytokines in serum of patients with aseptic loosening of hip prosthesis. J Bone Joint Surg Br. 1998;80:912–917.PubMedCrossRef Granchi D, Verri E, Ciapetti G, Stea S, Savarino L, Sudanese A, Mieti M, Rotini R, Dallari D, Zinghi G, Montanaro L. Bone resorbing cytokines in serum of patients with aseptic loosening of hip prosthesis. J Bone Joint Surg Br. 1998;80:912–917.PubMedCrossRef
16.
Zurück zum Zitat Greim H, Lehnet G. Critical Data Evaluation for BAT and EKA Values, Series: Biological Exposure Values for Occupational Toxicants and Carcinogens H. Vol 2. Weinheim, Germany: Wiley-VCH; 1995. Greim H, Lehnet G. Critical Data Evaluation for BAT and EKA Values, Series: Biological Exposure Values for Occupational Toxicants and Carcinogens H. Vol 2. Weinheim, Germany: Wiley-VCH; 1995.
17.
Zurück zum Zitat Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am. 2001;83:428–436.PubMedCrossRef Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am. 2001;83:428–436.PubMedCrossRef
18.
Zurück zum Zitat Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed
19.
Zurück zum Zitat Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP. The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am. 2005;87:781–787.PubMedCrossRef Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP. The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am. 2005;87:781–787.PubMedCrossRef
20.
Zurück zum Zitat Jacobs JJ, Roebuck KA, Archibeck M, Hallab NJ, Glant TT. Osteolysis: basic science. Clin Orthop Relat Res. 2001;393:71–77.PubMedCrossRef Jacobs JJ, Roebuck KA, Archibeck M, Hallab NJ, Glant TT. Osteolysis: basic science. Clin Orthop Relat Res. 2001;393:71–77.PubMedCrossRef
21.
Zurück zum Zitat Joshi AB, Porter ML, Trail IA, Hunt LP, Murphy JC, Hardinge K. Long term results of Charnley low-friction arthroplasty in young patients. J Bone Joint Surg Br. 1993;75:616–623.PubMed Joshi AB, Porter ML, Trail IA, Hunt LP, Murphy JC, Hardinge K. Long term results of Charnley low-friction arthroplasty in young patients. J Bone Joint Surg Br. 1993;75:616–623.PubMed
22.
Zurück zum Zitat Lee SH, Brennan FR, Jacobs JJ, Urban RM, Ragasa DR, Glant TT. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements. J Orthop Res. 1997;15:40–49.PubMedCrossRef Lee SH, Brennan FR, Jacobs JJ, Urban RM, Ragasa DR, Glant TT. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements. J Orthop Res. 1997;15:40–49.PubMedCrossRef
23.
Zurück zum Zitat Luetzner J, Krummenauer F, Lengel AM, Ziegler J, Witzleb WC. Serum metal ion exposure after total knee arthroplasty. Clin Orthop Relat Res. 2007;461:136–142.PubMed Luetzner J, Krummenauer F, Lengel AM, Ziegler J, Witzleb WC. Serum metal ion exposure after total knee arthroplasty. Clin Orthop Relat Res. 2007;461:136–142.PubMed
24.
Zurück zum Zitat MacDonald SJ. Metal-on-metal total hip arthroplasty: the concerns. Clin Orthop Relat Res. 2004;429:86–93.PubMedCrossRef MacDonald SJ. Metal-on-metal total hip arthroplasty: the concerns. Clin Orthop Relat Res. 2004;429:86–93.PubMedCrossRef
25.
Zurück zum Zitat MacDonald SJ, Brodner W, Jacobs JJ. A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty. 2004;19(8 suppl 3):12–16.PubMedCrossRef MacDonald SJ, Brodner W, Jacobs JJ. A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty. 2004;19(8 suppl 3):12–16.PubMedCrossRef
26.
Zurück zum Zitat Maezawa K, Nozawa M, Hirose T, Matsuda K, Yasuma M, Shitoto K, Kurosawa H. Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty. Arch Orthop Trauma Surg. 2002;122:283–287.PubMedCrossRef Maezawa K, Nozawa M, Hirose T, Matsuda K, Yasuma M, Shitoto K, Kurosawa H. Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty. Arch Orthop Trauma Surg. 2002;122:283–287.PubMedCrossRef
27.
Zurück zum Zitat Merritt K, Brown SA. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthop Relat Res. 1996;329(suppl):S233–S243.PubMedCrossRef Merritt K, Brown SA. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthop Relat Res. 1996;329(suppl):S233–S243.PubMedCrossRef
28.
Zurück zum Zitat Montero-Ocampo C, Lopez H, Salinas Rodriguez A. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer’s solution. J Biomed Mater Res. 1996;32:583–591.PubMedCrossRef Montero-Ocampo C, Lopez H, Salinas Rodriguez A. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer’s solution. J Biomed Mater Res. 1996;32:583–591.PubMedCrossRef
29.
Zurück zum Zitat Morgan MS. The biological exposure indices: a key component in protecting workers from toxic chemicals. Environ Health Perspect. 1997;105(suppl 1):105–115.PubMedCrossRef Morgan MS. The biological exposure indices: a key component in protecting workers from toxic chemicals. Environ Health Perspect. 1997;105(suppl 1):105–115.PubMedCrossRef
30.
Zurück zum Zitat Sargeant A, Goswami T, Swank M. Ion concentrations from hip implants. J Surg Orthop Adv. 2006;15:113–114.PubMed Sargeant A, Goswami T, Swank M. Ion concentrations from hip implants. J Surg Orthop Adv. 2006;15:113–114.PubMed
31.
Zurück zum Zitat Savarino L, Granchi D, Ciapetti G, Cenni E, Greco M, Rotini R, Veronesi CA, Baldini N, Giunti A. Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results. J Biomed Mater Res. 2003;66:450–456.CrossRef Savarino L, Granchi D, Ciapetti G, Cenni E, Greco M, Rotini R, Veronesi CA, Baldini N, Giunti A. Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results. J Biomed Mater Res. 2003;66:450–456.CrossRef
32.
Zurück zum Zitat Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J Biomed Mater Res. 2002;63:467–474.PubMedCrossRef Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J Biomed Mater Res. 2002;63:467–474.PubMedCrossRef
33.
Zurück zum Zitat Savarino L, Granchi D, Ciapetti G, Stea S, Donati ME, Zinghi G, Fontanesi G, Rotini R, Montanaro L. Effects of metal ions on white blood cells of patients with failed total joint arthroplasties. J Biomed Mater Res. 1999;47:543–550.PubMedCrossRef Savarino L, Granchi D, Ciapetti G, Stea S, Donati ME, Zinghi G, Fontanesi G, Rotini R, Montanaro L. Effects of metal ions on white blood cells of patients with failed total joint arthroplasties. J Biomed Mater Res. 1999;47:543–550.PubMedCrossRef
34.
Zurück zum Zitat Savarino L, Stea S, Granchi D, Visentin M, Ciapetti G, Donati ME, Rollo G, Zinghi G, Pizzoferrato A, Montanaro L, Toni A. Sister chromatid exchanges and ion release in patients wearing fracture fixation devices. J Biomed Mater Res. 2000;50:21–26.PubMedCrossRef Savarino L, Stea S, Granchi D, Visentin M, Ciapetti G, Donati ME, Rollo G, Zinghi G, Pizzoferrato A, Montanaro L, Toni A. Sister chromatid exchanges and ion release in patients wearing fracture fixation devices. J Biomed Mater Res. 2000;50:21–26.PubMedCrossRef
35.
Zurück zum Zitat Schaffer AW, Pilger A, Engelhardt C, Zweymueller K, Ruediger HW. Increased blood cobalt and chromium after total hip replacement. J Toxicol Clin Toxicol. 1999;37:839–844.PubMedCrossRef Schaffer AW, Pilger A, Engelhardt C, Zweymueller K, Ruediger HW. Increased blood cobalt and chromium after total hip replacement. J Toxicol Clin Toxicol. 1999;37:839–844.PubMedCrossRef
36.
Zurück zum Zitat Signorello LB, Ye W, Fryzek JP, Lipworth L, Fraumeni JF Jr, Blot WJ, McLaughlin JK, Nyren O. Nationwide study of cancer risk among hip replacement patients in Sweden. J Natl Cancer Inst. 2001;93:1405–1410.PubMedCrossRef Signorello LB, Ye W, Fryzek JP, Lipworth L, Fraumeni JF Jr, Blot WJ, McLaughlin JK, Nyren O. Nationwide study of cancer risk among hip replacement patients in Sweden. J Natl Cancer Inst. 2001;93:1405–1410.PubMedCrossRef
37.
Zurück zum Zitat Skipor AK, Campbell PA, Patterson LM, Amstutz HC, Schmalzried TP, Jacobs JJ. Serum and urine metal levels in patients with metal-on-metal surface arthroplasty. J Mater Sci Mater Med. 2002;13:1227–1234.PubMedCrossRef Skipor AK, Campbell PA, Patterson LM, Amstutz HC, Schmalzried TP, Jacobs JJ. Serum and urine metal levels in patients with metal-on-metal surface arthroplasty. J Mater Sci Mater Med. 2002;13:1227–1234.PubMedCrossRef
38.
Zurück zum Zitat Smith SL, Dowson D, Goldsmith AA. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacement. Proc Inst Mech Eng H. 2001;215:161–170.PubMedCrossRef Smith SL, Dowson D, Goldsmith AA. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacement. Proc Inst Mech Eng H. 2001;215:161–170.PubMedCrossRef
39.
Zurück zum Zitat Soderman P, Malchau H, Herberts P. Outcome after total hip arthroplasty: Part I. General health evaluation in relation to definition of failure in the Swedish National Total Hip Arthroplasty register. Acta Orthop Scand. 2000;71:354–359.PubMedCrossRef Soderman P, Malchau H, Herberts P. Outcome after total hip arthroplasty: Part I. General health evaluation in relation to definition of failure in the Swedish National Total Hip Arthroplasty register. Acta Orthop Scand. 2000;71:354–359.PubMedCrossRef
40.
Zurück zum Zitat Stea S, Visentin M, Granchi D, Savarino L, Dallari D, Gualtieri G, Rollo G, Toni A, Pizzoferrato A, Montanaro L. Sister chromatid exchange in patients with joint prostheses. J Arthroplasty. 2000;15:772–777.PubMedCrossRef Stea S, Visentin M, Granchi D, Savarino L, Dallari D, Gualtieri G, Rollo G, Toni A, Pizzoferrato A, Montanaro L. Sister chromatid exchange in patients with joint prostheses. J Arthroplasty. 2000;15:772–777.PubMedCrossRef
41.
Zurück zum Zitat Tharani R, Dorey FJ, Schmalzried TP. The risk of cancer following total hip or knee arthroplasty. J Bone Joint Surg Am. 2001;83:774–780.PubMed Tharani R, Dorey FJ, Schmalzried TP. The risk of cancer following total hip or knee arthroplasty. J Bone Joint Surg Am. 2001;83:774–780.PubMed
42.
Zurück zum Zitat Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg Br. 2007;89:441–448.PubMedCrossRef Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg Br. 2007;89:441–448.PubMedCrossRef
43.
Zurück zum Zitat Witzleb WC, Ziegler J, Krummenauer F, Neumeister V, Guenther KP. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop. 2006;77:697–705.PubMedCrossRef Witzleb WC, Ziegler J, Krummenauer F, Neumeister V, Guenther KP. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop. 2006;77:697–705.PubMedCrossRef
Metadaten
Titel
Does Ion Release Differ Between Hip Resurfacing and Metal-on-metal THA?
verfasst von
Antonio Moroni, MD
Lucia Savarino, BSc
Matteo Cadossi, MD
Nicola Baldini, MD
Sandro Giannini, MD
Publikationsdatum
01.03.2008
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 3/2008
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-007-0106-2

Weitere Artikel der Ausgabe 3/2008

Clinical Orthopaedics and Related Research® 3/2008 Zur Ausgabe

Symposium: New Approaches to Shoulder Surgery

Biological Augmentation of Rotator Cuff Tendon Repair

Symposium: Tribute to Dr. Anthony F. DePalma, First Editor-in-Chief of Clinical Orthopaedics and Related Research

Anthony Frederick DePalma, MD

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.