Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 4/2009

01.04.2009 | Original Article

Component Alignment in Hip Resurfacing Using Computer Navigation

verfasst von: Chris Bailey, FRCS(Tr&Orth), Rehan Gul, FRCS(Tr&Orth), Mark Falworth, FRCS(Tr&Orth), Steven Zadow, FRANZCR, Roger Oakeshott, FRACS

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 4/2009

Einloggen, um Zugang zu erhalten

Abstract

The use of computer navigation during hip resurfacing has been proposed to reduce the risk of a malaligned component and notching with subsequent postoperative femoral neck fracture. Femoral component malalignment and notching have been identified as the major factors associated with femoral neck fracture after hip resurfacing. We performed 37 hip resurfacing procedures using an imageless computer navigation system. Preoperatively, we generated a patient-specific computer model of the proximal femur and planned a target angle for placement of the femoral component in the coronal plane. The mean navigation angle after implantation (135.5°) correlated with the target stem-shaft angle (135.4°). After implantation, the mean stem-shaft angle of the femoral component measured by three-dimensional computed tomography (135.1°) correlated with the navigation target stem-shaft angle (135.4°). The computer navigation system generates a reliable model of the proximal femur. It allows accurate placement of the femoral component and provides precise measurement of implant alignment during hip resurfacing, thereby reducing the risk of component malpositioning and femoral neck notching.
Literatur
1.
Zurück zum Zitat Amstutz HC, Antoniades JT, Le Duff MJ. Results for metal-on-metal hybrid hip resurfacing for Crowe type-I and II developmental dysplasia. J Bone Joint Surg Am. 2007;89:339–346.PubMedCrossRef Amstutz HC, Antoniades JT, Le Duff MJ. Results for metal-on-metal hybrid hip resurfacing for Crowe type-I and II developmental dysplasia. J Bone Joint Surg Am. 2007;89:339–346.PubMedCrossRef
2.
Zurück zum Zitat Barrett AR, Davies BL, Gomes MP, Harris SJ, Henckel J, Jakopec M, Kannan V, Rodriguez y Baena FM, Cobb JP. Computer-assisted hip resurfacing surgery using the Acrobot® navigation system. Proc Inst Mech Eng. 2007;221:773–785.CrossRef Barrett AR, Davies BL, Gomes MP, Harris SJ, Henckel J, Jakopec M, Kannan V, Rodriguez y Baena FM, Cobb JP. Computer-assisted hip resurfacing surgery using the Acrobot® navigation system. Proc Inst Mech Eng. 2007;221:773–785.CrossRef
3.
Zurück zum Zitat Beaulé PE, Campbell PA, Hoke R, Dorey F. Notching of the femoral neck during resurfacing arthroplasty of the hip: a vascular study. J Bone Joint Surg Br. 2006;88:35–39.PubMedCrossRef Beaulé PE, Campbell PA, Hoke R, Dorey F. Notching of the femoral neck during resurfacing arthroplasty of the hip: a vascular study. J Bone Joint Surg Br. 2006;88:35–39.PubMedCrossRef
4.
Zurück zum Zitat Beaulé PE, Dorey FJ, LeDuff M, Gruen T, Amstutz H. Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip. Clin Orthop Relat Res. 2004;418:87–93.PubMedCrossRef Beaulé PE, Dorey FJ, LeDuff M, Gruen T, Amstutz H. Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip. Clin Orthop Relat Res. 2004;418:87–93.PubMedCrossRef
5.
Zurück zum Zitat Beaulé PE, Lee JL, Le Duff MJ, Amstutz H, Ebramzadeh E. Orientation of the femoral component in surface arthroplasty of the hip: a biomechanical and clinical analysis. J Bone Joint Surg Am. 2004;86:2015–2021.PubMed Beaulé PE, Lee JL, Le Duff MJ, Amstutz H, Ebramzadeh E. Orientation of the femoral component in surface arthroplasty of the hip: a biomechanical and clinical analysis. J Bone Joint Surg Am. 2004;86:2015–2021.PubMed
6.
Zurück zum Zitat Belei P, Skwara A, De La Fuente M, Schkommodau E, Fuchs S, Wirtz DC, Kämper C, Radermacher K. Fluoroscopic navigation system for hip surface replacement. Comput Aided Surg. 2007;12:160–167.PubMedCrossRef Belei P, Skwara A, De La Fuente M, Schkommodau E, Fuchs S, Wirtz DC, Kämper C, Radermacher K. Fluoroscopic navigation system for hip surface replacement. Comput Aided Surg. 2007;12:160–167.PubMedCrossRef
7.
Zurück zum Zitat Cobb JP, Kannan V, Brust K, Thevendran G. Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res. 2007;463:90–97.PubMed Cobb JP, Kannan V, Brust K, Thevendran G. Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res. 2007;463:90–97.PubMed
8.
Zurück zum Zitat Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004;86:177–184.PubMedCrossRef Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004;86:177–184.PubMedCrossRef
9.
Zurück zum Zitat Davis ET, Gallie P, Macgroarty K, Waddell JP, Schemitsch E. The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham hip resurfacing. J Bone Joint Surg Br. 2007;89:557–560.PubMedCrossRef Davis ET, Gallie P, Macgroarty K, Waddell JP, Schemitsch E. The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham hip resurfacing. J Bone Joint Surg Br. 2007;89:557–560.PubMedCrossRef
10.
Zurück zum Zitat Dorr L, Malik A, Wan Z, Long WT, Harris M. Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res. 2007;465:92–99.PubMed Dorr L, Malik A, Wan Z, Long WT, Harris M. Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res. 2007;465:92–99.PubMed
11.
Zurück zum Zitat Ecker T, Tannast M, Murphy SB. Computed tomography-based surgical navigation for hip arthroplasty. Clin Orthop Relat Res. 2007;465:100–105.PubMed Ecker T, Tannast M, Murphy SB. Computed tomography-based surgical navigation for hip arthroplasty. Clin Orthop Relat Res. 2007;465:100–105.PubMed
12.
Zurück zum Zitat Ganapathi M, Vendittoli PA, Lavigne M, Günther KP. Femoral component positioning in hip resurfacing with and without navigation. Clin Orthop Relat Res. 2008 May 17 [Epub ahead of print]. Ganapathi M, Vendittoli PA, Lavigne M, Günther KP. Femoral component positioning in hip resurfacing with and without navigation. Clin Orthop Relat Res. 2008 May 17 [Epub ahead of print].
13.
Zurück zum Zitat Gandhi R, Marchie A, Farrokhyar F, Mahomed N. Computer navigation in total hip replacement: a meta-analysis. Int Orthop. 2008 Apr 3 [Epub ahead of print]. Gandhi R, Marchie A, Farrokhyar F, Mahomed N. Computer navigation in total hip replacement: a meta-analysis. Int Orthop. 2008 Apr 3 [Epub ahead of print].
14.
Zurück zum Zitat Haaker RGA, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty. 2007;22:151–159.PubMedCrossRef Haaker RGA, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty. 2007;22:151–159.PubMedCrossRef
15.
Zurück zum Zitat Hart R, Svab P, Filan P. Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study. Arch Orthop Trauma Surg. 2008;128:429–434.PubMedCrossRef Hart R, Svab P, Filan P. Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study. Arch Orthop Trauma Surg. 2008;128:429–434.PubMedCrossRef
16.
Zurück zum Zitat Hodgson A, Helmy N, Masri BA, Greidanus NV, Inkpen KB, Duncan CP, Garbuz DS, Anglin C. Comparative repeatability of guide-pin positioning in computer-assisted and manual femoral head resurfacing arthroplasty. Proc Inst Mech Eng. 2007;221:713–724. Hodgson A, Helmy N, Masri BA, Greidanus NV, Inkpen KB, Duncan CP, Garbuz DS, Anglin C. Comparative repeatability of guide-pin positioning in computer-assisted and manual femoral head resurfacing arthroplasty. Proc Inst Mech Eng. 2007;221:713–724.
17.
Zurück zum Zitat Hodgson AJ, Inkpen KB, Shekhman M, Anglin C, Tonetti J, Masri BA, Duncan CP, Garbuz DS, Greidanus NV. Computer-assisted femoral head resurfacing. Comput Aided Surg. 2005;10:337–343.PubMedCrossRef Hodgson AJ, Inkpen KB, Shekhman M, Anglin C, Tonetti J, Masri BA, Duncan CP, Garbuz DS, Greidanus NV. Computer-assisted femoral head resurfacing. Comput Aided Surg. 2005;10:337–343.PubMedCrossRef
18.
Zurück zum Zitat Jolley MN, Salvati EA, Brown GC. Early results and complications of surface replacement of the hip. J Bone Joint Surg Am. 1982;64:366–377.PubMed Jolley MN, Salvati EA, Brown GC. Early results and complications of surface replacement of the hip. J Bone Joint Surg Am. 1982;64:366–377.PubMed
19.
Zurück zum Zitat Krüger S, Zambelli PY, Leyvraz PF, Jolles BM. Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy? Int Orthop. 2007 Aug 24 [Epub ahead of print]. Krüger S, Zambelli PY, Leyvraz PF, Jolles BM. Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy? Int Orthop. 2007 Aug 24 [Epub ahead of print].
20.
Zurück zum Zitat Markolf KL, Amstutz HC. Mechanical strength of the femur following resurfacing and conventional hip replacement procedures. Clin Orthop Relat Res. 1980;147:170–180.PubMed Markolf KL, Amstutz HC. Mechanical strength of the femur following resurfacing and conventional hip replacement procedures. Clin Orthop Relat Res. 1980;147:170–180.PubMed
21.
Zurück zum Zitat Mont MA, Seyley TM, Ulrich SD, Beaule PE, Boyd HS, Grecula MJ, Goldberg VM, Kennedy WR, Marker DR, Schmalzried TP, Sparling EA, Vail TP, Amstutz HC. Effect of changing indications and techniques on total hip resurfacing. Clin Orthop Relat Res. 2007;465:63–70.PubMed Mont MA, Seyley TM, Ulrich SD, Beaule PE, Boyd HS, Grecula MJ, Goldberg VM, Kennedy WR, Marker DR, Schmalzried TP, Sparling EA, Vail TP, Amstutz HC. Effect of changing indications and techniques on total hip resurfacing. Clin Orthop Relat Res. 2007;465:63–70.PubMed
22.
Zurück zum Zitat Schnurr C, Michael JW, Eysel P, König DP. Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy. Int Orthop. 2007 Dec 22 [Epub ahead of print]. Schnurr C, Michael JW, Eysel P, König DP. Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy. Int Orthop. 2007 Dec 22 [Epub ahead of print].
23.
Zurück zum Zitat Shimmin AJ, Back D. Femoral neck fractures following Birmingham hip resurfacing. J Bone Joint Surg Br. 2005;87:463–464.PubMedCrossRef Shimmin AJ, Back D. Femoral neck fractures following Birmingham hip resurfacing. J Bone Joint Surg Br. 2005;87:463–464.PubMedCrossRef
25.
Zurück zum Zitat Treacy RB, McBryde CW, Pynsent PB. Birmingham hip resurfacing arthroplasty. J Bone Joint Surg Br. 2005;87:167–170.PubMedCrossRef Treacy RB, McBryde CW, Pynsent PB. Birmingham hip resurfacing arthroplasty. J Bone Joint Surg Br. 2005;87:167–170.PubMedCrossRef
26.
Zurück zum Zitat Ybinger T, Kumpan W. Enhanced acetabular component positioning through computer-assisted navigation. Int Orthop. 2007;31:S35–S38.PubMedCrossRef Ybinger T, Kumpan W. Enhanced acetabular component positioning through computer-assisted navigation. Int Orthop. 2007;31:S35–S38.PubMedCrossRef
27.
Zurück zum Zitat Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullmann W, Zweymüller K. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results. J Arthroplasty. 2007;22:812–817.PubMedCrossRef Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullmann W, Zweymüller K. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results. J Arthroplasty. 2007;22:812–817.PubMedCrossRef
Metadaten
Titel
Component Alignment in Hip Resurfacing Using Computer Navigation
verfasst von
Chris Bailey, FRCS(Tr&Orth)
Rehan Gul, FRCS(Tr&Orth)
Mark Falworth, FRCS(Tr&Orth)
Steven Zadow, FRANZCR
Roger Oakeshott, FRACS
Publikationsdatum
01.04.2009
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 4/2009
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0584-x

Weitere Artikel der Ausgabe 4/2009

Clinical Orthopaedics and Related Research® 4/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.