Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 3/2010

01.03.2010 | Clinical Research

Custom Cementless Stem Improves Hip Function in Young Patients at 15-year Followup

verfasst von: Xavier Flecher, MD, Oliver Pearce, MD, Sebastien Parratte, MD, Jean-Manuel Aubaniac, MD, Jean-Noel Argenson, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 3/2010

Einloggen, um Zugang zu erhalten

Abstract

THA in young patients is challenging regarding restoration and survival because patients are young, active, and tend to have disturbed anatomy. We asked whether a three-dimensional custom cementless stem could restore hip function, decrease osteolysis and wear, and enhance stem survival in young patients. We retrospectively reviewed 212 patients (233 hips) younger than 50 years (mean, 40 years) at a followup of 5 to 16 years (mean, 10 years). The Merle D’Aubigné-Postel and Harris hip scores improved at last followup. No thigh pain was recorded for any of the patients; 187 of the 212 patients (88%) had full activity recovery, 206 had full range of motion, and 151 had a score greater than 80 points for all five categories of the Hip disability and Osteoarthritis Outcome score. Five patients had femoral osteolysis not associated with pain. With revision for any reason as an end point, the survivorship was 87% (range, 77%–97%) at 15 years, and considering stem revision only, the survivorship was 93% (confidence interval, 90%–97%) at 15 years. Our data compare favorably with those from series using standard cementless stems at the same followup with a high percentage of patients achieving functional restoration and a low rate of complications.
Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Aldinger PR, Thomsen M, Mau H, Ewerbeck V, Breusch SJ. Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand. 2003;74:253–258.CrossRefPubMed Aldinger PR, Thomsen M, Mau H, Ewerbeck V, Breusch SJ. Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand. 2003;74:253–258.CrossRefPubMed
2.
Zurück zum Zitat Amstutz HC, Sakai DN. Total joint replacement for ankylosed hips: indications, technique, and preliminary results. J Bone Joint Surg Am. 1975;57:619–625.PubMed Amstutz HC, Sakai DN. Total joint replacement for ankylosed hips: indications, technique, and preliminary results. J Bone Joint Surg Am. 1975;57:619–625.PubMed
3.
Zurück zum Zitat Argenson JN, Flecher X, Parratte S, Aubaniac JM. Anatomy of the dysplastic hip and consequences for total hip arthroplasty. Clin Orthop Relat Res. 2007;465:40–45.PubMed Argenson JN, Flecher X, Parratte S, Aubaniac JM. Anatomy of the dysplastic hip and consequences for total hip arthroplasty. Clin Orthop Relat Res. 2007;465:40–45.PubMed
4.
Zurück zum Zitat Argenson JN, Ryembault E, Flecher X, Brassart N, Parratte S, Aubaniac JM. Three-dimensional anatomy of the hip in osteoarthritis after developmental dysplasia. J Bone Joint Surg Br. 2005;87:1192–1196.CrossRefPubMed Argenson JN, Ryembault E, Flecher X, Brassart N, Parratte S, Aubaniac JM. Three-dimensional anatomy of the hip in osteoarthritis after developmental dysplasia. J Bone Joint Surg Br. 2005;87:1192–1196.CrossRefPubMed
5.
Zurück zum Zitat Bargar WL. Shape the implant to the patient: a rationale for the use of custom-fit cementless total hip implants. Clin Orthop Relat Res. 1989;249:73–78.PubMed Bargar WL. Shape the implant to the patient: a rationale for the use of custom-fit cementless total hip implants. Clin Orthop Relat Res. 1989;249:73–78.PubMed
6.
Zurück zum Zitat Barrack RL, Jasty M, Bragdon C, Haire T, Harris WH. Thigh pain despite bone ingrowth into uncemented femoral stems. J Bone Joint Surg Br. 1992;74:507–510.PubMed Barrack RL, Jasty M, Bragdon C, Haire T, Harris WH. Thigh pain despite bone ingrowth into uncemented femoral stems. J Bone Joint Surg Br. 1992;74:507–510.PubMed
7.
Zurück zum Zitat Beaule PE, Dorey FJ, Hoke R, Leduff M, Amstutz HC. The value of patient activity level in the outcome of total hip arthroplasty. J Arthroplasty. 2006;21:547–552.CrossRefPubMed Beaule PE, Dorey FJ, Hoke R, Leduff M, Amstutz HC. The value of patient activity level in the outcome of total hip arthroplasty. J Arthroplasty. 2006;21:547–552.CrossRefPubMed
8.
Zurück zum Zitat Bourne RB, Rorabeck CH, Ghazal ME, Lee MH. Pain in the thigh following total hip replacement with a porous-coated anatomic prosthesis for osteoarthrosis: a five-year follow-up study. J Bone Joint Surg Am. 1994;76:1464–1470.PubMed Bourne RB, Rorabeck CH, Ghazal ME, Lee MH. Pain in the thigh following total hip replacement with a porous-coated anatomic prosthesis for osteoarthrosis: a five-year follow-up study. J Bone Joint Surg Am. 1994;76:1464–1470.PubMed
9.
Zurück zum Zitat Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr. Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am. 1997;79:1007–1012.PubMed Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr. Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am. 1997;79:1007–1012.PubMed
10.
Zurück zum Zitat Capello WN, D’Antonio JA, Feinberg JR, Manley MT. Hydroxyapatite-coated total hip femoral components in patients less than fifty years old: clinical and radiographic results after five to eight years of follow-up. J Bone Joint Surg Am. 1997;79:1023–1029.PubMed Capello WN, D’Antonio JA, Feinberg JR, Manley MT. Hydroxyapatite-coated total hip femoral components in patients less than fifty years old: clinical and radiographic results after five to eight years of follow-up. J Bone Joint Surg Am. 1997;79:1023–1029.PubMed
11.
Zurück zum Zitat Capello WN, D’Antonio JA, Feinberg JR, Manley MT. Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old: a concise follow-up of a previous report. J Bone Joint Surg Am. 2003;85:885–889.PubMed Capello WN, D’Antonio JA, Feinberg JR, Manley MT. Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old: a concise follow-up of a previous report. J Bone Joint Surg Am. 2003;85:885–889.PubMed
12.
Zurück zum Zitat Charnley GJ. Numerical grading of clinical results. In: Charnley J, ed. Low Friction Arthroplasty of the Hip. Berlin, Germany: Springer Verlag; 1979:20–24. Charnley GJ. Numerical grading of clinical results. In: Charnley J, ed. Low Friction Arthroplasty of the Hip. Berlin, Germany: Springer Verlag; 1979:20–24.
13.
Zurück zum Zitat Charnley J. Low Friction Arthroplasty of the Hip. Theory and Practice. New York, NY: Springer; 1979. Charnley J. Low Friction Arthroplasty of the Hip. Theory and Practice. New York, NY: Springer; 1979.
14.
Zurück zum Zitat Collis DK. Long-term (twelve to eighteen-year) follow-up of cemented total hip replacements in patients who were less than fifty years old: a follow-up note. J Bone Joint Surg Am. 1991;73:593–597.PubMed Collis DK. Long-term (twelve to eighteen-year) follow-up of cemented total hip replacements in patients who were less than fifty years old: a follow-up note. J Bone Joint Surg Am. 1991;73:593–597.PubMed
15.
Zurück zum Zitat Crowe JF, Mani VJ, Ranawat CS. Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am. 1979;61:15–23.PubMed Crowe JF, Mani VJ, Ranawat CS. Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am. 1979;61:15–23.PubMed
16.
Zurück zum Zitat D’Antonio JA, Capello WN, Manley MT, Geesink R. Hydroxyapatite femoral stems for total hip arthroplasty: 10- to 13-year followup. Clin Orthop Relat Res. 2001;393:101–111.CrossRefPubMed D’Antonio JA, Capello WN, Manley MT, Geesink R. Hydroxyapatite femoral stems for total hip arthroplasty: 10- to 13-year followup. Clin Orthop Relat Res. 2001;393:101–111.CrossRefPubMed
17.
Zurück zum Zitat D’Aubigne RM, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475.PubMed D’Aubigne RM, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475.PubMed
18.
Zurück zum Zitat Davis AM, Perruccio AV, Canizares M, Tennant A, Hawker GA, Conaghan PG, Roos EM, Jordan JM, Maillefert JF, Dougados M, Lohmander LS. The development of a short measure of physical function for hip OA HOOS-Physical Function Shortform (HOOS-PS): an OARSI/OMERACT initiative. Osteoarthritis Cartilage. 2008;16:551–559.CrossRefPubMed Davis AM, Perruccio AV, Canizares M, Tennant A, Hawker GA, Conaghan PG, Roos EM, Jordan JM, Maillefert JF, Dougados M, Lohmander LS. The development of a short measure of physical function for hip OA HOOS-Physical Function Shortform (HOOS-PS): an OARSI/OMERACT initiative. Osteoarthritis Cartilage. 2008;16:551–559.CrossRefPubMed
19.
Zurück zum Zitat Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis: factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.CrossRefPubMed Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis: factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.CrossRefPubMed
20.
Zurück zum Zitat Duffy GP, Prpa B, Rowland CM, Berry DJ. Primary uncemented Harris-Galante acetabular components in patients 50 years old or younger: results at 10 to 12 years. Clin Orthop Relat Res. 2004;427:157–161.CrossRefPubMed Duffy GP, Prpa B, Rowland CM, Berry DJ. Primary uncemented Harris-Galante acetabular components in patients 50 years old or younger: results at 10 to 12 years. Clin Orthop Relat Res. 2004;427:157–161.CrossRefPubMed
21.
Zurück zum Zitat Engh CA, Bobyn JD. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res. 1988;231:7–28.PubMed Engh CA, Bobyn JD. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res. 1988;231:7–28.PubMed
22.
Zurück zum Zitat Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed
23.
Zurück zum Zitat Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P. Total hip arthroplasty for primary osteoarthrosis in younger patients in the Finnish arthroplasty register: 4,661 primary replacements followed for 0-22 years. Acta Orthop. 2005;76:28–41.CrossRefPubMed Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P. Total hip arthroplasty for primary osteoarthrosis in younger patients in the Finnish arthroplasty register: 4,661 primary replacements followed for 0-22 years. Acta Orthop. 2005;76:28–41.CrossRefPubMed
24.
Zurück zum Zitat Flecher X, Argenson JN, Parratte S, Ryembault E, Aubaniac JM. [Custom cementless stem for osteoarthritis following developmental hip dysplasia] [in French]. Rev Chir Orthop Reparatrice Appar Mot. 2006;92:332–342.PubMed Flecher X, Argenson JN, Parratte S, Ryembault E, Aubaniac JM. [Custom cementless stem for osteoarthritis following developmental hip dysplasia] [in French]. Rev Chir Orthop Reparatrice Appar Mot. 2006;92:332–342.PubMed
25.
Zurück zum Zitat Giannikas KA, Din R, Sadiq S, Dunningham TH. Medium-term results of the ABG total hip arthroplasty in young patients. J Arthroplasty. 2002;17:184–188.CrossRefPubMed Giannikas KA, Din R, Sadiq S, Dunningham TH. Medium-term results of the ABG total hip arthroplasty in young patients. J Arthroplasty. 2002;17:184–188.CrossRefPubMed
26.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.PubMed Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.PubMed
27.
Zurück zum Zitat Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed
28.
Zurück zum Zitat Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE. The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties. Acta Orthop Scand. 2000;71:337–353.PubMedCrossRef Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE. The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties. Acta Orthop Scand. 2000;71:337–353.PubMedCrossRef
29.
Zurück zum Zitat Husmann O, Rubin PJ, Leyvraz PF, de Roguin B, Argenson JN. Three-dimensional morphology of the proximal femur. J Arthroplasty. 1997;12:444–450.CrossRefPubMed Husmann O, Rubin PJ, Leyvraz PF, de Roguin B, Argenson JN. Three-dimensional morphology of the proximal femur. J Arthroplasty. 1997;12:444–450.CrossRefPubMed
30.
Zurück zum Zitat Jialiang T, Zhongyou M, Fuxing P, Zongke Z, Bin S, Jing Y. Primary total hip arthroplasty with Duraloc cup in patients younger than 50 years: a 5- to 7-year follow-up study. J Arthroplasty. 2009 Feb 3. [Epub ahead of print] Jialiang T, Zhongyou M, Fuxing P, Zongke Z, Bin S, Jing Y. Primary total hip arthroplasty with Duraloc cup in patients younger than 50 years: a 5- to 7-year follow-up study. J Arthroplasty. 2009 Feb 3. [Epub ahead of print]
31.
Zurück zum Zitat Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef
32.
Zurück zum Zitat Kawate K, Ohneda Y, Ohmura T, Yajima H, Sugimoto K, Takakura Y. Computed tomography-based custom-made stem for dysplastic hips in Japanese patients. J Arthroplasty. 2009;24:65–70.CrossRefPubMed Kawate K, Ohneda Y, Ohmura T, Yajima H, Sugimoto K, Takakura Y. Computed tomography-based custom-made stem for dysplastic hips in Japanese patients. J Arthroplasty. 2009;24:65–70.CrossRefPubMed
33.
Zurück zum Zitat Keener JD, Callaghan JJ, Goetz DD, Pederson DR, Sullivan PM, Johnston RC. Twenty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old: a concise follow-up of a previous report. J Bone Joint Surg Am. 2003;85:1066–1072.PubMed Keener JD, Callaghan JJ, Goetz DD, Pederson DR, Sullivan PM, Johnston RC. Twenty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old: a concise follow-up of a previous report. J Bone Joint Surg Am. 2003;85:1066–1072.PubMed
34.
Zurück zum Zitat Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY. Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg Am. 2004;86:2475–2481.CrossRefPubMed Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY. Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg Am. 2004;86:2475–2481.CrossRefPubMed
35.
Zurück zum Zitat Kim YH, Oh SH, Kim JS. Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J Bone Joint Surg Am. 2003;85:109–114.CrossRefPubMed Kim YH, Oh SH, Kim JS. Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J Bone Joint Surg Am. 2003;85:109–114.CrossRefPubMed
36.
Zurück zum Zitat Koulouvaris P, Stafylas K, Sculco T, Xenakis T. Custom-design implants for severe distorted proximal anatomy of the femur in young adults followed for 4–8 years. Acta Orthop. 2008;79:203–210.CrossRefPubMed Koulouvaris P, Stafylas K, Sculco T, Xenakis T. Custom-design implants for severe distorted proximal anatomy of the femur in young adults followed for 4–8 years. Acta Orthop. 2008;79:203–210.CrossRefPubMed
37.
Zurück zum Zitat LaPorte DM, Mont MA, Hungerford DS. Proximally porous-coated ingrowth prostheses: limits of use. Orthopedics. 1999;22:1154–1160; quiz 1161–1162.PubMed LaPorte DM, Mont MA, Hungerford DS. Proximally porous-coated ingrowth prostheses: limits of use. Orthopedics. 1999;22:1154–1160; quiz 1161–1162.PubMed
38.
Zurück zum Zitat Lavigne M, Masse V, Girard J, Roy AG, Vendittoli PA. [Return to sport after hip resurfacing or total hip arthroplasty: a randomized study] [in French]. Rev Chir Orthop Reparatrice Appar Mot. 2008;94:361–367.PubMed Lavigne M, Masse V, Girard J, Roy AG, Vendittoli PA. [Return to sport after hip resurfacing or total hip arthroplasty: a randomized study] [in French]. Rev Chir Orthop Reparatrice Appar Mot. 2008;94:361–367.PubMed
39.
Zurück zum Zitat Mahomed N, Schatzker J, Hearn T. Biomechanical analysis of a distally interlocked press-fit femoral total hip prosthesis. J Arthroplasty. 1993;8:129–132.CrossRefPubMed Mahomed N, Schatzker J, Hearn T. Biomechanical analysis of a distally interlocked press-fit femoral total hip prosthesis. J Arthroplasty. 1993;8:129–132.CrossRefPubMed
40.
Zurück zum Zitat Massin P, Geais L, Astoin E, Simondi M, Lavaste F. The anatomic basis for the concept of lateralized femoral stems: a frontal plane radiographic study of the proximal femur. J Arthroplasty. 2000;15:93–101.CrossRefPubMed Massin P, Geais L, Astoin E, Simondi M, Lavaste F. The anatomic basis for the concept of lateralized femoral stems: a frontal plane radiographic study of the proximal femur. J Arthroplasty. 2000;15:93–101.CrossRefPubMed
41.
Zurück zum Zitat McAuley JP, Szuszczewicz ES, Young A, Engh CA Sr. Total hip arthroplasty in patients 50 years and younger. Clin Orthop Relat Res. 2004;418:119–125.CrossRefPubMed McAuley JP, Szuszczewicz ES, Young A, Engh CA Sr. Total hip arthroplasty in patients 50 years and younger. Clin Orthop Relat Res. 2004;418:119–125.CrossRefPubMed
42.
Zurück zum Zitat McLaughlin JR, Lee KR. Total hip arthroplasty in young patients: 8- to 13-year results using an uncemented stem. Clin Orthop Relat Res. 2000;373:153–163.CrossRefPubMed McLaughlin JR, Lee KR. Total hip arthroplasty in young patients: 8- to 13-year results using an uncemented stem. Clin Orthop Relat Res. 2000;373:153–163.CrossRefPubMed
43.
Zurück zum Zitat Naal FD, Schmied M, Munzinger U, Leunig M, Hersche O. Outcome of hip resurfacing arthroplasty in patients with developmental hip dysplasia. Clin Orthop Relat Res. 2009;467:1516–1521.CrossRefPubMed Naal FD, Schmied M, Munzinger U, Leunig M, Hersche O. Outcome of hip resurfacing arthroplasty in patients with developmental hip dysplasia. Clin Orthop Relat Res. 2009;467:1516–1521.CrossRefPubMed
44.
Zurück zum Zitat Nercessian OA, Wu WH, Sarkissian H. Clinical and radiographic results of cementless AML total hip arthroplasty in young patients. J Arthroplasty. 2001;16:312–316.CrossRefPubMed Nercessian OA, Wu WH, Sarkissian H. Clinical and radiographic results of cementless AML total hip arthroplasty in young patients. J Arthroplasty. 2001;16:312–316.CrossRefPubMed
45.
Zurück zum Zitat Nilsdotter AK, Lohmander LS, Klässbo M, Roos EM. Hip disability and osteoarthritis outcome score (HOOS): validity and responsiveness in total hip replacement. BMC Musculoskelet Disord. 2003;4:10.CrossRefPubMed Nilsdotter AK, Lohmander LS, Klässbo M, Roos EM. Hip disability and osteoarthritis outcome score (HOOS): validity and responsiveness in total hip replacement. BMC Musculoskelet Disord. 2003;4:10.CrossRefPubMed
46.
Zurück zum Zitat Nourbash PS, Paprosky WG. Cementless femoral designing concerns: rationale for extensive porous coating. Clin Orthop Relat Res. 1998;355:189–199.CrossRefPubMed Nourbash PS, Paprosky WG. Cementless femoral designing concerns: rationale for extensive porous coating. Clin Orthop Relat Res. 1998;355:189–199.CrossRefPubMed
47.
Zurück zum Zitat Ramaniraka NA, Rakotomanana LR, Rubin PJ, Leyvraz P. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses] [in French]. Rev Chir Orthop Reparatrice Appar Mot. 2000;86:590–597.PubMed Ramaniraka NA, Rakotomanana LR, Rubin PJ, Leyvraz P. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses] [in French]. Rev Chir Orthop Reparatrice Appar Mot. 2000;86:590–597.PubMed
48.
Zurück zum Zitat Reigstad O, Siewers P, Røkkum M, Espehaug B. Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: follow-up of 75 hips for 15–18 years. Acta Orthop. 2008;79:194–202.CrossRefPubMed Reigstad O, Siewers P, Røkkum M, Espehaug B. Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: follow-up of 75 hips for 15–18 years. Acta Orthop. 2008;79:194–202.CrossRefPubMed
49.
Zurück zum Zitat Reize PK, Wülker N. The Adaptiva custom-made stem: our reasons for not using it anymore. Int Orthop. 2007;31:217–222.CrossRefPubMed Reize PK, Wülker N. The Adaptiva custom-made stem: our reasons for not using it anymore. Int Orthop. 2007;31:217–222.CrossRefPubMed
50.
Zurück zum Zitat Rubin PJ, Leyvraz PF, Aubaniac JM, Argenson JN, Esteve P, de Roguin B. The morphology of the proximal femur: a three-dimensional radiographic analysis. J Bone Joint Surg Br. 1992;74:28–32.PubMed Rubin PJ, Leyvraz PF, Aubaniac JM, Argenson JN, Esteve P, de Roguin B. The morphology of the proximal femur: a three-dimensional radiographic analysis. J Bone Joint Surg Br. 1992;74:28–32.PubMed
51.
Zurück zum Zitat Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2001;388:125–134.CrossRefPubMed Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2001;388:125–134.CrossRefPubMed
52.
Zurück zum Zitat Schramm M, Keck F, Hohmann D, Pitto RP. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg. 2000;120:407–412.CrossRefPubMed Schramm M, Keck F, Hohmann D, Pitto RP. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg. 2000;120:407–412.CrossRefPubMed
53.
Zurück zum Zitat Sinha RK, Dungy DS, Yeon HB. Primary total hip arthroplasty with a proximally porous-coated femoral stem. J Bone Joint Surg Am. 2004;86:1254–1261.CrossRefPubMed Sinha RK, Dungy DS, Yeon HB. Primary total hip arthroplasty with a proximally porous-coated femoral stem. J Bone Joint Surg Am. 2004;86:1254–1261.CrossRefPubMed
54.
Zurück zum Zitat Stulberg SD, Stulberg BN, Wixson RL. The rationale, design characteristics, and preliminary results of a primary custom total hip prosthesis. Clin Orthop Relat Res. 1989;249:79–96.PubMed Stulberg SD, Stulberg BN, Wixson RL. The rationale, design characteristics, and preliminary results of a primary custom total hip prosthesis. Clin Orthop Relat Res. 1989;249:79–96.PubMed
55.
Zurück zum Zitat Wettstein M, Mouhsine E, Argenson JN, Rubin PJ, Aubaniac JM, Leyvraz PF. Three-dimensional computed cementless custom femoral stems in young patients: midterm followup. Clin Orthop Relat Res. 2005;437:169–175.CrossRefPubMed Wettstein M, Mouhsine E, Argenson JN, Rubin PJ, Aubaniac JM, Leyvraz PF. Three-dimensional computed cementless custom femoral stems in young patients: midterm followup. Clin Orthop Relat Res. 2005;437:169–175.CrossRefPubMed
56.
Zurück zum Zitat Zenz P, Pospisil C, Fertschak W, Schwäger. [10 years of cementless implantation of total hip endoprosthesis using Zweymüller’s stem] [in German]. Z Orthop Ihre Grenzgeb. 1995;133:558–561.CrossRefPubMed Zenz P, Pospisil C, Fertschak W, Schwäger. [10 years of cementless implantation of total hip endoprosthesis using Zweymüller’s stem] [in German]. Z Orthop Ihre Grenzgeb. 1995;133:558–561.CrossRefPubMed
Metadaten
Titel
Custom Cementless Stem Improves Hip Function in Young Patients at 15-year Followup
verfasst von
Xavier Flecher, MD
Oliver Pearce, MD
Sebastien Parratte, MD
Jean-Manuel Aubaniac, MD
Jean-Noel Argenson, MD
Publikationsdatum
01.03.2010
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 3/2010
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-1045-x

Weitere Artikel der Ausgabe 3/2010

Clinical Orthopaedics and Related Research® 3/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.