Background

Cardiac resynchronization therapy (CRT) can provide cardiac reverse remodeling (RR), which may include mechanical reverse remodeling (MRR) and/or electrical reverse remodeling (ERR). However, uncoupling of MRR and ERR is not uncommon, and the underlying mechanisms are not clear. This study aimed to evaluate the relationship of myocardial substrate characteristics as assessed by myocardial perfusion imaging (MPI) and cardiac RR post-CRT.

Materials and methods

Forty-one patients (26 men, mean age 66 ± 10 years) with heart failure received CRT for at least 12 months were assigned to three groups according to their levels of RR: I, MRR + ERR (ESV reduced ≥15 % and intrinsic QRS duration reduced ≥10 ms); II, MRR only (ESV reduced ≥15 %); and III, non-responder (the others). All the patients also underwent MPI under transient CRT-off to evaluate the intrinsic myocardial substrates, including myocardial scar, LV volumes and function, systolic dyssynchrony, and activation sequences. In addition, ventricular tachycardia (VT) and ventricular fibrillation (VF) detected by the CRT devices during follow-up periods were also recorded.

Results

Quantitative analysis of MPI showed that there were significant differences for scar burden [15.9 ± 9.5, 26.8 ± 16.1, and 45.6 ± 15.1 % for group I (n = 15), II (n = 16), and III (n = 10), respectively, p < 0.001], EDV (136.6 ± 64.9, 221.6 ± 123.9, and 351.8 ± 216.3 ml, p = 0.002), ESV (82.6 ± 59.8, 172.3 ± 117.2, and 293.3 ± 209.6 ml, p = 0.001), LVEF (44.9 ± 15.0, 25.6 ± 10.9, and 21.5 ± 11.7 %, p < 0.001), systolic phase SD (23.4° ± 10.3°, 36.0° ± 16.2°, and 57.0° ± 22.2°, p < 0.001), and bandwidth (72.5° ± 31.1°, 113.4° ± 56.4°, and 199.1° ± 90.1°, p < 0.001). Myocardial scar interfered with the normal propagation of mechanical activation, resulting in heterogeneous activation sequences. Compared with group II (MRR only), group I (ERR + MRR) had significantly less initial activation segments (1.9 ± 1.0 vs. 2.6 ± 0.7, p < 0.05) and shorter maximal contraction delay (46.9° ± 12.9° vs. 58.8° ± 18.5°, p < 0.05). During the periods of follow-up, 21 patients developed VT/VF, including only 1 patient (1 VT) in group I (6.7 %), 8 patients (7 VT and 1 VF) in group II (50 %), and 9 patients (7 VT and 5 VF) in group III (90 %).

Conclusion

The characteristics of myocardial substrates as assessed by MPI differed significantly between different levels of cardiac RR post-CRT. Myocardial scar played an important role in the development of ERR. Different cardiac RR levels contributed to different incidences of ventricular arrhythmia, and the combination of ERR and MRR provided highest anti-arrhythmic effects.
Literatur
1.
Zurück zum Zitat Linde C, Ellenbogen K, McAlister FA. Cardiac resynchronization therapy (CRT): clinical trials, guidelines, and target populations. Heart Rhythm. 2012;9:S3–13.CrossRefPubMed Linde C, Ellenbogen K, McAlister FA. Cardiac resynchronization therapy (CRT): clinical trials, guidelines, and target populations. Heart Rhythm. 2012;9:S3–13.CrossRefPubMed
2.
Zurück zum Zitat Sebag FA, Martins RP, Defaye P, Hidden-Lucet F, Mabo P, Daubert JC, et al. Reverse electrical remodeling by cardiac resynchronization therapy: prevalence and clinical impact. J Cardiovasc Electrophysiol. 2012;23:1219–27.CrossRefPubMed Sebag FA, Martins RP, Defaye P, Hidden-Lucet F, Mabo P, Daubert JC, et al. Reverse electrical remodeling by cardiac resynchronization therapy: prevalence and clinical impact. J Cardiovasc Electrophysiol. 2012;23:1219–27.CrossRefPubMed
3.
Zurück zum Zitat Tereshchenko LG, Henrikson CA, Berger RD. Strong coherence between heart rate variability and intracardiac repolarization lability during biventricular pacing is associated with reverse electrical remodeling of the native conduction and improved outcome. J Electrocardiol. 2011;44:713–7.CrossRefPubMed Tereshchenko LG, Henrikson CA, Berger RD. Strong coherence between heart rate variability and intracardiac repolarization lability during biventricular pacing is associated with reverse electrical remodeling of the native conduction and improved outcome. J Electrocardiol. 2011;44:713–7.CrossRefPubMed
4.
Zurück zum Zitat Henrikson CA, Spragg DD, Cheng A, Capps M, Devaughn K, Marine JE, et al. Evidence for electrical remodeling of the native conduction system with cardiac resynchronization therapy. Pacing Clin Electrophysiol. 2007;30:591–5.CrossRefPubMed Henrikson CA, Spragg DD, Cheng A, Capps M, Devaughn K, Marine JE, et al. Evidence for electrical remodeling of the native conduction system with cardiac resynchronization therapy. Pacing Clin Electrophysiol. 2007;30:591–5.CrossRefPubMed
5.
Zurück zum Zitat Tereshchenko LG, Henrikson CA, Stempniewicz P, Han L, Berger RD. Antiarrhythmic effect of reverse electrical remodeling associated with cardiac resynchronization therapy. Pacing Clin Electrophysiol. 2011;34:357–64.CrossRefPubMed Tereshchenko LG, Henrikson CA, Stempniewicz P, Han L, Berger RD. Antiarrhythmic effect of reverse electrical remodeling associated with cardiac resynchronization therapy. Pacing Clin Electrophysiol. 2011;34:357–64.CrossRefPubMed
6.
Zurück zum Zitat Chen J, Garcia EV, Folks RD, Cooke CD, Faber TL, Tauxe EL, et al. Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony. J Nucl Cardiol. 2005;12:687–95.CrossRefPubMed Chen J, Garcia EV, Folks RD, Cooke CD, Faber TL, Tauxe EL, et al. Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony. J Nucl Cardiol. 2005;12:687–95.CrossRefPubMed
7.
Zurück zum Zitat Chen J, Henneman MM, Trimble MA, Bax JJ, Borges-Neto S, Iskandrian AE, et al. Assessment of left ventricular mechanical dyssynchrony by phase analysis of ECG-gated SPECT myocardial perfusion imaging. J Nucl Cardiol. 2008;15:127–36.CrossRefPubMed Chen J, Henneman MM, Trimble MA, Bax JJ, Borges-Neto S, Iskandrian AE, et al. Assessment of left ventricular mechanical dyssynchrony by phase analysis of ECG-gated SPECT myocardial perfusion imaging. J Nucl Cardiol. 2008;15:127–36.CrossRefPubMed
8.
Zurück zum Zitat Hsu TH, Huang WS, Chen CC, Hung GU, Chen TC, Kao CH, et al. Left ventricular systolic and diastolic dyssynchrony assessed by phase analysis of gated SPECT myocardial perfusion imaging: a comparison with speckle tracking echocardiography. Ann Nucl Med. 2013;27:764–71.CrossRefPubMed Hsu TH, Huang WS, Chen CC, Hung GU, Chen TC, Kao CH, et al. Left ventricular systolic and diastolic dyssynchrony assessed by phase analysis of gated SPECT myocardial perfusion imaging: a comparison with speckle tracking echocardiography. Ann Nucl Med. 2013;27:764–71.CrossRefPubMed
9.
Zurück zum Zitat Hung GU, Huang JL, Lin WY, Tsai SC, Wang KY, Chen SA, et al. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging. Eur J Nucl Med Mol Imaging. 2014;41:1224–31.CrossRefPubMed Hung GU, Huang JL, Lin WY, Tsai SC, Wang KY, Chen SA, et al. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging. Eur J Nucl Med Mol Imaging. 2014;41:1224–31.CrossRefPubMed
10.
Zurück zum Zitat Soman P, Chen J. Left ventricular dyssynchrony assessment using myocardial single-photon emission CT. Semin Nucl Med. 2014;44:314–9.CrossRefPubMed Soman P, Chen J. Left ventricular dyssynchrony assessment using myocardial single-photon emission CT. Semin Nucl Med. 2014;44:314–9.CrossRefPubMed
11.
Zurück zum Zitat Itoh M, Yoshida A, Fukuzawa K, Kiuchi K, Imamura K, Fujiwara R, et al. Time-dependent effect of cardiac resynchronization therapy on ventricular repolarization and ventricular arrhythmias. Europace Eur Pacing Arrhythm Cardiac Electrophysiol J Working Groups Cardiac Pacing Arrhythm Cardiac Cell Electrophysiol Eur Soc Cardiol. 2013;15:1798–804.CrossRef Itoh M, Yoshida A, Fukuzawa K, Kiuchi K, Imamura K, Fujiwara R, et al. Time-dependent effect of cardiac resynchronization therapy on ventricular repolarization and ventricular arrhythmias. Europace Eur Pacing Arrhythm Cardiac Electrophysiol J Working Groups Cardiac Pacing Arrhythm Cardiac Cell Electrophysiol Eur Soc Cardiol. 2013;15:1798–804.CrossRef
12.
Zurück zum Zitat Friehling M, Chen J, Saba S, Bazaz R, Schwartzman D, Adelstein EC, et al. A prospective pilot study to evaluate the relationship between acute change in left ventricular synchrony after cardiac resynchronization therapy and patient outcome using a single-injection gated SPECT protocol. Circ Cardiovasc Imaging. 2011;4:532–9.CrossRefPubMedPubMedCentral Friehling M, Chen J, Saba S, Bazaz R, Schwartzman D, Adelstein EC, et al. A prospective pilot study to evaluate the relationship between acute change in left ventricular synchrony after cardiac resynchronization therapy and patient outcome using a single-injection gated SPECT protocol. Circ Cardiovasc Imaging. 2011;4:532–9.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Boogers MJ, Chen J, van Bommel RJ, Borleffs CJ, Dibbets-Schneider P, van der Hiel B, et al. Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT. Eur J Nucl Med Mol Imaging. 2011;38:230–8.CrossRefPubMed Boogers MJ, Chen J, van Bommel RJ, Borleffs CJ, Dibbets-Schneider P, van der Hiel B, et al. Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT. Eur J Nucl Med Mol Imaging. 2011;38:230–8.CrossRefPubMed
14.
Zurück zum Zitat Tracy CM, Epstein AE, Darbar D, Dimarco JP, Dunbar SB, Estes NA 3rd, et al. 2012 ACCF/AHA/HRS Focused Update of the 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Heart Rhythm. 2012;9:1737–53.CrossRefPubMed Tracy CM, Epstein AE, Darbar D, Dimarco JP, Dunbar SB, Estes NA 3rd, et al. 2012 ACCF/AHA/HRS Focused Update of the 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Heart Rhythm. 2012;9:1737–53.CrossRefPubMed
15.
Zurück zum Zitat Young JB, Abraham WT, Smith AL, Leon AR, Lieberman R, Wilkoff B, et al. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. JAMA. 2003;289:2685–94.CrossRefPubMed Young JB, Abraham WT, Smith AL, Leon AR, Lieberman R, Wilkoff B, et al. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. JAMA. 2003;289:2685–94.CrossRefPubMed
16.
Zurück zum Zitat Ermis C, Seutter R, Zhu AX, Benditt LC, VanHeel L, Sakaguchi S, et al. Impact of upgrade to cardiac resynchronization therapy on ventricular arrhythmia frequency in patients with implantable cardioverter-defibrillators. J Am Coll Cardiol. 2005;46:2258–63.CrossRefPubMed Ermis C, Seutter R, Zhu AX, Benditt LC, VanHeel L, Sakaguchi S, et al. Impact of upgrade to cardiac resynchronization therapy on ventricular arrhythmia frequency in patients with implantable cardioverter-defibrillators. J Am Coll Cardiol. 2005;46:2258–63.CrossRefPubMed
17.
Zurück zum Zitat Hou PN, Tsai SC, Lin WY, Cheng CM, Chiang KF, Chang YC, et al. Relationship of quantitative parameters of myocardial perfusion SPECT and ventricular arrhythmia in patients receiving cardiac resynchronization therapy. Ann Nucl Med. 2015;29:772–8.CrossRefPubMed Hou PN, Tsai SC, Lin WY, Cheng CM, Chiang KF, Chang YC, et al. Relationship of quantitative parameters of myocardial perfusion SPECT and ventricular arrhythmia in patients receiving cardiac resynchronization therapy. Ann Nucl Med. 2015;29:772–8.CrossRefPubMed
Metadaten
Titel
Relationship of myocardial substrate characteristics as assessed by myocardial perfusion imaging and cardiac reverse remodeling levels after cardiac resynchronization therapy
verfasst von
Kuo-Feng Chiang
Chien-Ming Cheng
Shih-Chuan Tsai
Wan-Yu Lin
Yu-Cheng Chang
Jin-Long Huang
Guang-Uei Hung
Chia-Hung Kao
Shih-Ann Chen
Pesus Chou
Ji Chen
Publikationsdatum
25.05.2016
Verlag
Springer Japan
Erschienen in
Annals of Nuclear Medicine / Ausgabe 7/2016
Print ISSN: 0914-7187
Elektronische ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-016-1083-x

Weitere Artikel der Ausgabe 7/2016

Annals of Nuclear Medicine 7/2016 Zur Ausgabe