Skip to main content
Erschienen in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie 6/2009

01.06.2009 | Reports of Original Investigations

Ultrasound evidence of the optimal wrist position for radial artery cannulation

verfasst von: Keiko Mizukoshi, MD, Masayuki Shibasaki, MD, Fumimasa Amaya, MD, Takahiro Hirayama, MD, Fumihiro Shimizu, MD, Koji Hosokawa, MD, Satoru Hashimoto, MD, Yoshifumi Tanaka, MD

Erschienen in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie | Ausgabe 6/2009

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Radial artery cannulation is a common medical procedure for anesthesia and critical care. To establish the ideal wrist position for radial artery cannulation, we performed ultrasound examinations of the radial artery to investigate the effect of the angle of wrist extension on radial artery dimensions.

Clinical features

Measurements were performed in 17 healthy subjects and 17 surgical patients scheduled for coronary artery bypass graft (CABG) surgery. The radial artery was echographically visualized near the styloid process of the radius at the wrist. Radial artery dimensions were measured at wrist joint angles of 0, 15, 30, 45, 60 and 75°.

Observations

In both groups, radial artery height was affected by the wrist joint angle. Vessel height was decreased at 60° (one way ANOVA P = 0.027 vs 0°) and 75° (P < 0.001 vs 0, 15, 45°) in healthy subject and at 75° in CABG patients (P < 0.001 vs 0°). The mean differences in radial artery height at 0 and 75° were 0.33 ± 0.09 mm and 0.20 ± 0.06 mm for healthy and CABG patients, respectively. Vessel width was not affected by wrist joint angulation up to 75° of extension.

Conclusion

Our results demonstrate that in healthy subjects, radial artery dimensions are unaltered when the wrist joint is extended up to an angle of 45°. Extension at 60° for healthy subjects and 75° for CABG patients, however, results in a decrease in the height of the radial artery, which could possibly render arterial catheterization more difficult.
Literatur
1.
Zurück zum Zitat Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 2002; 6: 199–204.PubMedCrossRef Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 2002; 6: 199–204.PubMedCrossRef
2.
Zurück zum Zitat Karacalar S, Ture H, Baris S, et al. Ulnar artery versus radial artery approach for arterial cannulation: a prospective, comparative study. J Clin Anesth 2007; 19: 209–13.PubMedCrossRef Karacalar S, Ture H, Baris S, et al. Ulnar artery versus radial artery approach for arterial cannulation: a prospective, comparative study. J Clin Anesth 2007; 19: 209–13.PubMedCrossRef
3.
Zurück zum Zitat Mangar D, Thrush DN, Connell GR, Downs JB. Direct or modified Seldinger guide wire-directed technique for arterial catheter insertion. Anesth Analg 1993; 76: 714–7.PubMed Mangar D, Thrush DN, Connell GR, Downs JB. Direct or modified Seldinger guide wire-directed technique for arterial catheter insertion. Anesth Analg 1993; 76: 714–7.PubMed
4.
Zurück zum Zitat Ludman PF, Stephens NG, Harcombe A, et al. Radial versus femoral approach for diagnostic coronary angiography in stable angina pectoris. Am J Cardiol 1997; 79: 1239–41.PubMedCrossRef Ludman PF, Stephens NG, Harcombe A, et al. Radial versus femoral approach for diagnostic coronary angiography in stable angina pectoris. Am J Cardiol 1997; 79: 1239–41.PubMedCrossRef
5.
Zurück zum Zitat Benit E, Missault L, Eeman T, et al. Brachial, radial, or femoral approach for elective Palmaz-Schatz stent implantation: a randomized comparison. Cathet Cardiovasc Diagn 1997; 41: 124–30.PubMedCrossRef Benit E, Missault L, Eeman T, et al. Brachial, radial, or femoral approach for elective Palmaz-Schatz stent implantation: a randomized comparison. Cathet Cardiovasc Diagn 1997; 41: 124–30.PubMedCrossRef
6.
Zurück zum Zitat Yokoyama N, Takeshita S, Ochiai M, et al. Anatomic variations of the radial artery in patients undergoing transradial coronary intervention. Catheter Cardiovasc Interv 2000; 49: 357–62.PubMedCrossRef Yokoyama N, Takeshita S, Ochiai M, et al. Anatomic variations of the radial artery in patients undergoing transradial coronary intervention. Catheter Cardiovasc Interv 2000; 49: 357–62.PubMedCrossRef
7.
Zurück zum Zitat Yoo BS, Yoon J, Ko JY, et al. Anatomical consideration of the radial artery for transradial coronary procedures: arterial diameter, branching anomaly and vessel tortuosity. Int J Cardiol 2005; 101: 421–7.PubMedCrossRef Yoo BS, Yoon J, Ko JY, et al. Anatomical consideration of the radial artery for transradial coronary procedures: arterial diameter, branching anomaly and vessel tortuosity. Int J Cardiol 2005; 101: 421–7.PubMedCrossRef
8.
Zurück zum Zitat Mark JB, Slaughter TF. Cardiovascular monitoring. In: Miller RD, editor. Miller’s Anesthesia. 6th ed. Philadelphia, PA: Churchill Livingstone; 2004. p. 1272–3. Mark JB, Slaughter TF. Cardiovascular monitoring. In: Miller RD, editor. Miller’s Anesthesia. 6th ed. Philadelphia, PA: Churchill Livingstone; 2004. p. 1272–3.
9.
Zurück zum Zitat Kiemeneij F, Laarman GJ, Odekerken D, Slagboom T, van der Wieken R. A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, brachial and femoral approaches: the access study. J Am Coll Cardiol 1997; 29: 1269–75.PubMedCrossRef Kiemeneij F, Laarman GJ, Odekerken D, Slagboom T, van der Wieken R. A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, brachial and femoral approaches: the access study. J Am Coll Cardiol 1997; 29: 1269–75.PubMedCrossRef
10.
Zurück zum Zitat Kiemeneij F, Laarman GJ, de Melker E. Transradial artery coronary angioplasty. Am Heart J 1995; 129: 1–7.PubMedCrossRef Kiemeneij F, Laarman GJ, de Melker E. Transradial artery coronary angioplasty. Am Heart J 1995; 129: 1–7.PubMedCrossRef
11.
Zurück zum Zitat Kuo MH, Leong CP, Cheng YF, Chang HW. Static wrist position associated with least median nerve compression: sonographic evaluation. Am J Phys Med Rehabil 2001; 80: 256–60.PubMedCrossRef Kuo MH, Leong CP, Cheng YF, Chang HW. Static wrist position associated with least median nerve compression: sonographic evaluation. Am J Phys Med Rehabil 2001; 80: 256–60.PubMedCrossRef
12.
Zurück zum Zitat Ohara Y, Nakayama S, Furukawa H, Satoh Y, Suzuki H, Yanai H. Use of a wire-guided cannula for radial arterial cannulation. J Anesth 2007; 21: 83–5.PubMedCrossRef Ohara Y, Nakayama S, Furukawa H, Satoh Y, Suzuki H, Yanai H. Use of a wire-guided cannula for radial arterial cannulation. J Anesth 2007; 21: 83–5.PubMedCrossRef
Metadaten
Titel
Ultrasound evidence of the optimal wrist position for radial artery cannulation
verfasst von
Keiko Mizukoshi, MD
Masayuki Shibasaki, MD
Fumimasa Amaya, MD
Takahiro Hirayama, MD
Fumihiro Shimizu, MD
Koji Hosokawa, MD
Satoru Hashimoto, MD
Yoshifumi Tanaka, MD
Publikationsdatum
01.06.2009
Verlag
Springer-Verlag
Erschienen in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Ausgabe 6/2009
Print ISSN: 0832-610X
Elektronische ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-009-9093-y

Weitere Artikel der Ausgabe 6/2009

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 6/2009 Zur Ausgabe

Continuing Professional Development

Optimizing preoxygenation in adults

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.