Skip to main content
Erschienen in: Sports Medicine 1/2000

01.07.2000 | Current Opinion

Measures of Reliability in Sports Medicine and Science

verfasst von: Dr Will G. Hopkins

Erschienen in: Sports Medicine | Ausgabe 1/2000

Einloggen, um Zugang zu erhalten

Abstract

Reliability refers to the reproducibility of values of a test, assay or other measurement in repeated trials on the same individuals. Better reliability implies better precision of single measurements and better tracking of changes in measurements in research or practical settings. The main measures of reliability are within-subject random variation, systematic change in the mean, and retest correlation. A simple, adaptable form of within-subject variation is the typical (standard) error of measurement: the standard deviation of an individual’s repeated measurements. For many measurements in sports medicine and science, the typical error is best expressed as a coefficient of variation (percentage of the mean). A biased, more limited form of within-subject variation is the limits of agreement: the 95% likely range of change of an individual’s measurements between 2 trials. Systematic changes in the mean of a measure between consecutive trials represent such effects as learning, motivation or fatigue; these changes need to be eliminated from estimates of within-subject variation. Retest correlation is difficult to interpret, mainly because its value is sensitive to the heterogeneity of the sample of participants. Uses of reliability include decision-making when monitoring individuals, comparison of tests or equipment, estimation of sample size in experiments and estimation of the magnitude of individual differences in the response to a treatment. Reasonable precision for estimates of reliability requires approximately 50 study participants and at least 3 trials. Studies aimed at assessing variation in reliability between tests or equipment require complex designs and analyses that researchers seldom perform correctly. A wider understanding of reliability and adoption of the typical error as the standard measure of reliability would improve the assessment of tests and equipment in our disciplines.
Literatur
1.
Zurück zum Zitat Atkinson G, Nevill AM. Statistical methods for addressing measurement error (reliability) in variables relevant to sports medicine. Sports Med 1998; 26: 217–38PubMedCrossRef Atkinson G, Nevill AM. Statistical methods for addressing measurement error (reliability) in variables relevant to sports medicine. Sports Med 1998; 26: 217–38PubMedCrossRef
2.
Zurück zum Zitat Hopkins WG, Hawley JA, Burke LM. Design and analysis of research on sport performance enhancement. Med Sci Sports Exerc 1999; 31: 472–85PubMedCrossRef Hopkins WG, Hawley JA, Burke LM. Design and analysis of research on sport performance enhancement. Med Sci Sports Exerc 1999; 31: 472–85PubMedCrossRef
3.
Zurück zum Zitat Nevill AM, Atkinson G. Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science. Br J Sports Med 1997; 31: 314–8PubMedCrossRef Nevill AM, Atkinson G. Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science. Br J Sports Med 1997; 31: 314–8PubMedCrossRef
4.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 Feb; 8: 307–10CrossRef Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 Feb; 8: 307–10CrossRef
5.
Zurück zum Zitat Roebroeck ME, Harlaar J, Lankhorst GJ. The application of generalizability theory to reliability assessment: an illustration using isometric force measurements. Phys Ther 1993; 73: 386–401PubMed Roebroeck ME, Harlaar J, Lankhorst GJ. The application of generalizability theory to reliability assessment: an illustration using isometric force measurements. Phys Ther 1993; 73: 386–401PubMed
6.
Zurück zum Zitat VanLeeuwen DM, Barnes MD, Pase M. Generalizability theory: a unified approach to assessing the dependability (reliability) of measurements in the health sciences. J Outcome Measures 1998; 2: 302–25 VanLeeuwen DM, Barnes MD, Pase M. Generalizability theory: a unified approach to assessing the dependability (reliability) of measurements in the health sciences. J Outcome Measures 1998; 2: 302–25
7.
Zurück zum Zitat Bartko JJ. The intraclass correlation coefficient as a measure of reliability. Psych Reports 1966; 19: 3–11CrossRef Bartko JJ. The intraclass correlation coefficient as a measure of reliability. Psych Reports 1966; 19: 3–11CrossRef
8.
Zurück zum Zitat Kovaleski JE, Heitman RJ, Gurchiek LR, et al. Reliability and effects of leg dominance on lower extremity isokinetic force and work using the Closed Chain Rider System. J Sport Rehabil 1997; 6: 319–26 Kovaleski JE, Heitman RJ, Gurchiek LR, et al. Reliability and effects of leg dominance on lower extremity isokinetic force and work using the Closed Chain Rider System. J Sport Rehabil 1997; 6: 319–26
9.
Zurück zum Zitat Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psych Bull 1979; 86: 420–8CrossRef Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psych Bull 1979; 86: 420–8CrossRef
10.
Zurück zum Zitat Kovaleski JE, Ingersoll CD, Knight KL, et al. Reliability of the BTE Dynatrac isotonic dynamometer. Isokinet Exerc Sci 1996; 6: 41–3 Kovaleski JE, Ingersoll CD, Knight KL, et al. Reliability of the BTE Dynatrac isotonic dynamometer. Isokinet Exerc Sci 1996; 6: 41–3
11.
Zurück zum Zitat Hopkins WG. A new view of statistics. Available from: http://sportsci.org/resource/stats [Accessed 2000 Apr 18] Hopkins WG. A new view of statistics. Available from: http://​sportsci.​org/​resource/​stats [Accessed 2000 Apr 18]
12.
Zurück zum Zitat Hopkins WG, Manly BFJ. Errors in assigning grades based on tests of finite validity. Res Q Exerc Sport 1989; 60: 180–2PubMed Hopkins WG, Manly BFJ. Errors in assigning grades based on tests of finite validity. Res Q Exerc Sport 1989; 60: 180–2PubMed
13.
Zurück zum Zitat Cohen J. Statistical power analysis for the behavioral sciences. 2nd ed. Mahwah (NJ): Lawrence Erlbaum, 1988 Cohen J. Statistical power analysis for the behavioral sciences. 2nd ed. Mahwah (NJ): Lawrence Erlbaum, 1988
14.
Zurück zum Zitat Eliasziw M, Young SL, Woodbury MG, et al. Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. Phys Ther 1994; 74: 777–88PubMed Eliasziw M, Young SL, Woodbury MG, et al. Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. Phys Ther 1994; 74: 777–88PubMed
15.
Zurück zum Zitat Clark VR, Hopkins WG, Hawley JA, et al. Placebo effect of carbohydrate feedings during a 40-km cycling time trial. Med Sci Sports Exerc. In press Clark VR, Hopkins WG, Hawley JA, et al. Placebo effect of carbohydrate feedings during a 40-km cycling time trial. Med Sci Sports Exerc. In press
16.
Zurück zum Zitat Hopkins WG, Wolfinger RD. Estimating ‘individual differences’ in the response to an experimental treatment [abstract]. Med Sci Sports Exerc 1998; 30 (5): S135 Hopkins WG, Wolfinger RD. Estimating ‘individual differences’ in the response to an experimental treatment [abstract]. Med Sci Sports Exerc 1998; 30 (5): S135
17.
Zurück zum Zitat Tate RF, Klett GW. Optimal confidence intervals for the variance of a normal distribution. J Am Statist Assoc 1959; 54: 674–82CrossRef Tate RF, Klett GW. Optimal confidence intervals for the variance of a normal distribution. J Am Statist Assoc 1959; 54: 674–82CrossRef
18.
Zurück zum Zitat Hopkins WG. Generalizing to a population. Available from: http://sportsci.org/resource/stats/generalize.html [Accessed 2000 Apr 18] Hopkins WG. Generalizing to a population. Available from: http://​sportsci.​org/​resource/​stats/​generalize.​html [Accessed 2000 Apr 18]
19.
Zurück zum Zitat Hopkins WG. Reliability: calculations and more. Available from: http://sportsci.org/resource/stats/relycalc.html [Accessed 2000 Apr 18] Hopkins WG. Reliability: calculations and more. Available from: http://​sportsci.​org/​resource/​stats/​relycalc.​html [Accessed 2000 Apr 18]
20.
Zurück zum Zitat Schabort EJ, Hopkins WG, Hawley JA, et al. High reliability of performance of well-trained rowers on a rowing ergometer. J Sports Sci 1999; 17: 627–32PubMedCrossRef Schabort EJ, Hopkins WG, Hawley JA, et al. High reliability of performance of well-trained rowers on a rowing ergometer. J Sports Sci 1999; 17: 627–32PubMedCrossRef
Metadaten
Titel
Measures of Reliability in Sports Medicine and Science
verfasst von
Dr Will G. Hopkins
Publikationsdatum
01.07.2000
Verlag
Springer International Publishing
Erschienen in
Sports Medicine / Ausgabe 1/2000
Print ISSN: 0112-1642
Elektronische ISSN: 1179-2035
DOI
https://doi.org/10.2165/00007256-200030010-00001

Weitere Artikel der Ausgabe 1/2000

Sports Medicine 1/2000 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.