Skip to main content
Erschienen in: Journal of Neural Transmission 4/2022

Open Access 20.03.2022 | Neurology and Preclinical Neurological Studies - Original Article

Locus Coeruleus magnetic resonance imaging: a comparison between native-space and template-space approach

verfasst von: F. S. Giorgi, N. Martini, F. Lombardo, A. Galgani, L. Bastiani, D. Della Latta, H. Hlavata, C. L. Busceti, F. Biagioni, S. Puglisi-Allegra, N. Pavese, F. Fornai

Erschienen in: Journal of Neural Transmission | Ausgabe 4/2022

Abstract

Locus Coeruleus (LC) is the main noradrenergic nucleus of the brain, which is involved in many physiological functions including cognition; its impairment may be crucial in the neurobiology of a variety of brain diseases. Locus Coeruleus-Magnetic Resonance Imaging (LC-MRI) allows to identify in vivo LC in humans. Thus, a variety of research teams have been using LC-MRI to estimate LC integrity in normal aging and in patients affected by neurodegenerative disorders, where LC integrity my work as a biomarker. A number of variations between LC-MRI studies exist, concerning post-acquisition analysis and whether this had been performed within MRI native space or in ad hoc-built MRI template space. Moreover, the reproducibility and reliability of this tool is still to be explored. Therefore, in the present study, we analyzed a group of neurologically healthy, cognitively intact elderly subjects, using both a native space- and a template space-based LC-MRI analysis. We found a good inter-method agreement, particularly considering the LC Contrast Ratio. The template space-based approach provided a higher spatial resolution, lower operator-dependency, and allowed the analysis of LC topography. Our ad hoc-developed LC template showed LC morphological data that were in line with templates published very recently. Remarkably, present data significantly overlapped with a recently published LC “metaMask”, that had been obtained by averaging the results of a variety of previous LC-MRI studies. Thus, such a template space-based approach may pave the way to a standardized LC-MRI analysis and to be used in future clinic–anatomical correlations.
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1007/​s00702-022-02486-5.
F. S. Giorgi and N. Martini have equally contributed to the manuscript.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Locus Coeruleus (LC) is the main noradrenergic (NA) nucleus of the brain and provides the NA innervation for the whole cortical mantle and subcortical structures (Counts and Mufson 2012). LC belongs to the brainstem isodendritic core and is a key element of the so-called reticular ascending activating system (Moruzzi and Magoun 1949; Theofilas et al. 2015). LC contributes to a variety of brain functions, mainly by regulating neuronal homeostasis and modulating neural network activity (Poe et al. 2020). In particular, the LC-NA system plays a pivotal role in neurovascular coupling, blood–brain barrier homeostasis, and microglia modulation (Giorgi et al. 2020a, b); moreover, NA is crucial in wake/sleep cycle, attention and alert systems, and strongly contributes to learning and memory (Poe et al. 2020). This is due to a strong effect on modulating synaptic plasticity (e.g., Giorgi et al. 2006, 2008; Hansen 2017).
In the last decade, several studies have addressed the potential involvement of LC in the pathogenesis of neurodegenerative disorders (Gesi et al. 2000; Kelly et al. 2017). In particular, the development of MRI-based approaches aimed to visualize LC has allowed evaluating its integrity in vivo (see the reviews by Galgani et al. 2020; Beardmore et al. 2021). LC Magnetic Resonance Imaging (LC-MRI) has been already used to explore LC involvement in healthy aging (Dahl et al. 2019; Liu et al. 2020; Giorgi et al. 2021), Alzheimer’s Disease (Betts et al. 2019a; Jacobs et al. 2021), Parkinson’s Disease (Sommerauer et al. 2018; Li et al. 2019) and other pathological conditions (reviewed in Galgani et al. 2020). Thus, LC-MRI might add to the large variety of promising novel biomarkers that have been proposed in the last decade to improve diagnostic accuracy in neurodegenerative disorders (Frisoni et al. 2017; Baldacci et al. 2020).
Post-acquisition analysis often represents a major difference among LC-MRI studies; in particular, some authors have profited from data analysis performed in native-space (NS) (Olivieri et al. 2019; Jacobs et al. 2021), while others took advantage of an MRI template-space (TS) ad hoc built from their study sample itself (Dahl et al. 2019; Liu et al. 2020).
In a very recent study, Dahl et al. (2021) used a TS-based approach (which requires the construction of an LC mask—see Methods paragraph—identifying the region of interest of the LC in the MRI images), and developed an LC “MetaMask” taking into account a number of previously published LC masks (cited in Dahl et al. 2021). This metaMask was made freely available, thus giving the opportunity also to other groups to test the reliability of their study-specific LC mask and of the MetaMask itself.
In a previous study, we explored the association of LC-MRI features with aging in a group of healthy and cognitively intact elderly subjects, using an NS-based post-processing protocol (Giorgi et al. 2021). Then, in line with the most recent studies on LC-MRI (Dahl et al. 2019), we specifically developed a post-acquisition analysis, building a study-specific LC template, by profiting of those MRI scans acquired in the context of the previous study (Giorgi et al. 2021).
In the present paper, we aimed to assess and discuss the degree of inter-method agreement between the NS- and the TS-based approach. Finally, the LC mask we developed in the present study was compared with the above-described LC metaMask (Dahl et al. 2021).

Methods

Characteristics of the study sample

The demographic characteristics and the recruitment protocol of the study sample are reported in detail in Giorgi et al. (2021). Briefly, 53 healthy and cognitively intact elderly subjects (mean age 71.70 ± 4.69 years, 20 males; mean Mini Mental State Examination 27.04 ± 1.27) were recruited at the Pisa University Hospital and Fondazione “G. Monasterio”- CNR/Tuscany Region. Exclusion criteria were: severe medical/cardiological and/or psychiatric comorbidities; neurological disease potentially associated with cognitive decline; history of drugs/alcohol abuse; MRI signs of moderate-severe chronic vascular encephalopathy, according to Fazekas et al. (1987), or other significant alterations. Cognitive and neurological integrity had been evaluated at baseline (T0) and confirmed after 1-year follow-up (T1). Brain MRI was performed within 30 days from T0.

LC-MRI protocols

MRI scans were performed using a 3T MR-Unit (GE Excite HDx, GE, USA) with an 8-channel phased-array head coil.
The LC-sensitive sequence was acquired along the oblique axial plane (Fig. 1A), perpendicular to the fourth ventricle floor, covering an area from the inferior border of the pons to the posterior commissure. We used a 2D-FSE T1-weighted sequence with the following parameters: TR 600 ms; TE 14 ms; flip angle 90°; echo train length 2; NEX 5; matrix size 512 × 384; FOV 200 × 200 mm; pixel size 0.39 × 0.52 mm; 12 contiguous slices, slice thickness 2.2 mm, slice gap 0; acquisition time 14.29 min.
The complete Brain MRI protocol also included 2D-FLAIR, T2* GRE, Spin EchoT1- and FSE T2-weighted with fat saturation and diffusion-weighted imaging sequences. In addition, 3D-Fast-SPGR T1-weighted images were obtained: TR 10.7 ms; TE 4.9 ms; FOV 256 × 256 mm; matrix size 256 × 256; isotropic voxel 1 mm; NEX 1; acquisition time: 5.50 min.
The post-processing imaging analysis provided the quantification of two LC-MRI parameters: LC Contrast Ratio (LCCR), which represents the signal intensity of the LC, and the total amount of voxels considered as belonging to the LC (LCVOX), which was considered as an indirect estimation of LC volume.

Native space-based approach

The semi-automatic NS protocol was already described in Giorgi et al. (2021). Briefly, the analysis was performed by two independent trained operators, using a software developed in-house in Java language. LC region of interest (ROI) was manually placed at the level of the fourth ventricle floor, while two reference ROIs were positioned on the ventral pons (Ref), bilaterally. Once it had been placed in the first slice showing detectable LC-related hyperintensity, the software automatically dragged the ROIs across the contiguous slices. At this stage, the intensity threshold was automatically calculated as the lowest intensity value within the 10 spatially interconnected voxels with maximum intensity (Giorgi et al. 2021). All the voxels exceeding this threshold were highlighted and considered as the first pool of candidate LC-related voxels. The operators evaluated this pool and excluded voxels in anatomically incongruent positions; then, the software re-calculated the threshold and re-screened voxels in the LC-ROI, highlighting possible new candidate voxels. This round was repeated until all suitable voxels were identified. Finally, once the selection stage had been completed, the software computed LCCR-NS [LC(intensity)/Ref(intensity)] and LCVOX-NS. This method has been set up to provide the values related to both right and left LC combined.

Template space-based approach

Our templates for the 3D and the LC-MRI scans were built according to the same procedure proposed by other authors (Dahl et al. 2019), with minor modifications. The workflow steps are detailed below.
Whole brain 3D template creation
As the first step, a common space for the 3D anatomical MRI (template3D) was created using MRI images of the recruited cognitively intact healthy subjects. These were interpolated to an isotropic resolution of 0.5 mm and a nonuniform intensity correction was applied (N4 bias field correction) and then submitted to multi-resolution iterative registration of 3D scans (antsMultivariateTemplateConstruction2 of the Advanced Normalization Tools v.2.3.4 software (Avants et al. 2011). Registration parameters used were: number of iterations 30 × 90 × 20, cross-correlation similarity metric, Greedy SyN transformation model. Once the registration process had been completed, the aligned 3D volumes were averaged in order to obtain the group whole-brain template3D. We also saved the transformation matrices and warping fields that warped the 3D from the individual subject's space to the template3D space (see below).
Brainstem template creation
The second step was the creation of a common brainstem space for the acquisition of LC-sensitive sequence. Using the transformations calculated during the whole-brain template3D creation procedure, each scan obtained with LC-sensitive sequence was warped from the native 2D space to the space of the template3D itself. A second multi-resolution iterative registration was run with the same parameters (iterations, similarity metric, transformation model) described above. This spatial registration took into account the anatomical variability between subjects in the LC acquisitions, as well as the possible intra-subject misalignment between the LC and the 3D scans. As a result, we obtained the brainstem template, whose isotropic resolution was 0.5 mm.
LC mask creation
In the brainstem template, we found increased intensity and higher signal-to-noise ratio compared to the ventral pons, in a symmetrical bilateral region below the floor of the fourth ventricle. Considering the anatomical location of the signal, the LC/sub-coeruleus complex was considered the main signal source candidate (Betts et al. 2019a; Dahl et al. 2019). To identify those voxels more likely belonging to the LC and, thus, to create the LC mask, a semi-automatic thresholding procedure was performed. An expert operator placed two square 8.5 mm × 8.5 mm reference ROIs bilaterally in the ventral pons in each slice, using ITKsnap (www.​itksnap.​org) (Yushkevich et al. 2006). The threshold was computed following this formula: μROI + 4*σROI, where μROI and σROI are the mean value and the standard deviation in the reference ROIs, respectively. Then, a custom program written in Python selected all the voxels exceeding the threshold in the brainstem template, for both hemispheres. These represent the candidate LC-belonging voxels of the brainstem template. The segmentation mask was further refined by an expert neuroradiologist (FL) to exclude voxels that were anatomically incongruent with the LC (e.g., within the fourth ventricle).
LC-MRI parameters extraction
Once the LC mask was obtained, LC-sensitive scans of each subject were warped from the native space to the brainstem template space for data analysis, and the parameters LCCR developed by TS-based approach (LCCR-TS) and LCVOX developed by TS-based approach (LCVOX-TS) were extracted. The parameter LCCR-TS was calculated using the following formula: LCCR = [max(LC)—max(Ref)] / max(Ref), where max(Ref) and max(LC) are the maximum signal intensities in the left and right reference regions, and LC regions derived from the LC template segmentation, respectively.
LCVOX-TS was calculated as follows. First, the LC mask in the brainstem template was considered as the search space of the LC voxels. Then, reference ROIs were drawn on the LC scan warped to the brainstem template, and a subject-specific threshold was calculated using the same formula used for the LC mask. The number of voxels in the search space that exceed the subject-specific threshold constituted LCVOX-TS parameter value.
For each subject, the two LC-MRI parameters (LCCR and LCVOX) were calculated for left and right hemisphere separately (“left LC” and “right LC”, respectively), or for left and right LC combined (“combined LC”).
In order to maximally reduce any potential side-related intensity artifacts which might affect the results, we applied to LC scans a field correction algorithm (Tustison et al. 2010), and LC-related parameters were standardized using bilateral ROIs as reference regions, placed symmetrically in the left and right ventral pons (see above).

Comparison with previously published metaMask

Recently, an LC mask obtained by pooling a variety of study-specific LC masks (“metaMask”), was released and made freely available (https://​osf.​io/​sf2ky/​) (Dahl et al. 2021). To assess the compatibility between our TS-based approach and the published metaMask, we evaluated the overlap in the MNI space between our LC mask and the metaMask. To warp our LC mask into the MNI space, we first co-registered the brainstem template to the 0.5-mm iso-voxel MNI template using linear (rigid, then affine), followed by nonlinear (SyN) registration (Avants et al. 2011). Then, these transformations were applied to the LC mask using a nearest-neighbor interpolation to warp the LC mask into the MNI space. The degree of compatibility between our LC mask and the metaMask was expressed using the same parameters that Dahl et al. themselves described in their study, namely specificity and sensitivity (Dahl et al. 2021). These were calculated as the ratio between the number of voxels the study-specific LC mask and the LC metaMask have in common and the total number of voxels of the former and the latter, respectively. We calculated also the “accuracy” which was defined as the mean between sensitivity and specificity of the mask (Dahl et al. 2021). For comparison, we also warped the metaMask into the brainstem template through inverse transformation, and we additionally calculated the LC parameters using the metaMask in the TS approach.

Statistical analysis

Data normality was assessed through Shapiro–Wilk test and visual checking of heteroskedasticity. Since they did not show a Gaussian distribution, variables were Z-standardized. Pearson’s correlation was used to evaluate inter-method agreement (van Stralen et al. 2008) and age effect on TS-based LC parameters. A Paired-sample t-test was used to assess side-related differences within TS-based LC variables. Multiple comparisons were adjusted with False Discovery Rate (FDR) correction to rule out type I error. The level of significance was set at p < 0.05. All statistical analyses were performed using SPSS Version 25. GraphPad Prism 8.0 was used for graphical representations.

Results

Template space-based LC reconstruction

The spatial co-registration of each LC-sensitive scan to the brainstem template was carefully visually inspected. The obtained brainstem template showed marked hyperintensities bilaterally in the LC region, while the region of the ventral pons showed a rather homogeneous distribution. The final LC mask included a total number of 234 voxels across 17 axial slices. Figure 1B shows the 3D visualization of the LC probabilistic map, reflecting the coordinates of the maximum value of the left and right LC for each slice.

Template space-based LC features

We did not find any effect of age on TS-based LC parameters, neither considering the combined LC (LCCR-TS, r = -0.291, p = 0.07, LCVOX-TS, r = -0.254, p = 0.066), nor analyzing the two LC separately (LCCR-TS, r = − 0.213, p = 0.167, LCVOX-TS, r = − 0.273, p = 0.096 for the left LC; LCCR-TS, r = − 0.322, p = 0.076, LCVOX-TS, r = − 0.254, p = 0.152, for the right LC).
A side-related difference was observed between the two LCs. LCCR-TS and LCVOX-TS values of the left LC were higher than those of the right LC (t = 5.556, df = 52, p < 0.001; t = 4.434, df = 52, p < 0.001, respectively) (Fig. 2). Remarkably, there was no significant difference between left and right reference regions intensity values (t = 0.518, df = 52, p = 0.607).

Inter-method agreement

There was a good agreement between the signal intensity measures obtained by the two methods. LCCR-NS showed a direct correlation with LCCR-TS values obtained from two LC combined (r = 0.413, p = 0.004) (Fig. 3A). It was evaluated also the correlation of left and right LC values, separately assessed with the TS-based approach, with the single (i.e., including the values from left and right LC) parameters extracted with the NS-based approach, in order to assess whether the latter ones were more related to the LC signal of one side or the other one. We found that the same trend described above for the combined LC was observed when left and right LC were analyzed separately (r = 0.383, p = 0.010 and r = 0.371, p = 0.006, respectively) (Fig. 3B and C).
The NS- and TS-based methods showed a significant agreement with each other also concerning volume-related measures (although the inter-method agreement was lower compared to the LCCR ones), when considering either the combined LC (r = 0.340, p = 0.013) (Fig. 3D) or the two LC separately (r = 0.330, p 0.032 for the left LCVOX, r = 0.305, p = 0.026 for the right LCVOX) (Fig. 3E and F).

Compatibility of the template-based approach with LC metaMask

We found a high degree of compatibility between our LC mask and the LC metaMask (specificity 69.8%, sensibility 49.5% and accuracy 59.6%; Fig. 4). Moreover, the LC-MRI parameters calculated using our LC mask showed very strong direct correlation coefficients with those calculated using the LC metaMask (Supplementary Table 1).

Discussion

In vivo LC analysis by MRI has been performed by several authors and it will likely be a matter of interest also in future years, as LC degeneration represents a promising marker in a number of neurodegenerative disorders (Betts et al. 2019a; Galgani et al. 2020). In this study, we presented the results of an LC-MRI analysis performed using both an NS- and a TS-based approach in a group of cognitively healthy subjects. We successfully built an LC-MRI template and used it to extract LC imaging parameters. Then, we compared the results obtained with both approaches, and we showed a good inter-method agreement for LCVOX, and mostly for LCCR.
LCCR appears to be more directly related to LC features, since it simply represents the ratio between the MRI signal intensity of LC and the reference regions. This might explain why LCCR showed a higher correlation coefficient between the two methods. Nonetheless, there was not a complete concordance between NS- and TS-based approaches regarding this parameter. This may depend on the higher spatial resolution of the TS-based approach, which allows the identification of many voxels that were potentially excluded from the NS-based analysis, thereby affecting LCCR values.
Such a higher spatial resolution may also explain the lower concordance between NS- and TS-based approaches concerning the parameter LCVOX. Thus, LCVOX may be useful for LC-MRI analysis studies, since it provides the estimation of authentic LC volume. Even though we have already tried to extrapolate this parameter also using the NS-based approach (Giorgi et al. 2021), LCVOX computed with the TS-based method might be more appropriate to calculate the LC anatomical volume. In fact, as shown in present paper, and in line with what already shown by the groups that used a similar approach (e.g., Betts et al. 2017; Dahl et al. 2019), the spatial distribution of LC voxels closely followed LC anatomy. Concerning this aspect, it is also worth emphasizing that the distribution of LCVOX showed a higher value in the middle part of the LC mask and a lower one in its rostral and caudal parts; this is in line with anatomical data, which repeatedly showed that LC neurons are more abundant and densely packed in the middle part of the nucleus, while they are scattered towards LC rostral and caudal poles (Schwarz and Luo 2015). Also, the length and the volume of the nucleus estimated from the LC mask were close to what measured in histological studies (Fernandes et al. 2012) (Fig. 1A).
In a previous paper, in which we profited from the NS-based approach only (Giorgi et al. 2021), we did not find any association between LC features and age in this group of subjects. Here, we confirmed this observation also with the TS-based approach, both when merging data from right and left LC, and when considering the left and right LC separately. These findings are in line with recent post-mortem data, which, by profiting from unbiased stereology, did not show any significant LC involvement during physiological aging (Theofilas et al. 2017).
The left/right side-related difference we observed in the distribution of LC-MRI parameters deserves a special emphasis. Left LC showed higher LCCR and LCVOX values compared to the right one. To our knowledge, this has never been specifically addressed in post-mortem studies of LC. MRI studies of LC carried out by other authors (Betts et al. 2017; Liu et al. 2019) are compatible with the present finding in spite of different MRI scanners and LC post-acquisition methods. In the present study, all efforts were made to avoid any potential machine-related influence on LC signal (as witnessed also by the lack of differences between left and right ventral pons reference ROIs intensity), nonetheless side-related difference may still be partly due to uncommon artifacts (see also Betts et al. 2017). Such an asymmetry needs to be validated and, when confirmed, it should be specifically analyzed to better understand the role of LC in brain activities and brain disorders.
So far, all research teams that profited from a TS-based approach developed specific LC mask based on their own subjects’ sample (e.g., Betts et al. 2017; Dahl et al. 2019). However, in a very recent study Dahl et al. (2021) developed a so-called LC metaMask. This was built-up by pooling together the LC masks developed by various research groups. Concordance of the metaMask with each specific study-dependent mask was assessed in the same study (Dahl et al. 2021). The fact that our LC mask remarkably overlaps with Dahl’s group’s metaMask, even though it was not used to build it, lends further substance to the reliability of the TS-based approach for LC imaging studies.
In conclusion, our study showed a good agreement between NS- and TS-based approaches, with the latter method offering more advantages in terms of spatial resolution and regional analysis of LC. Furthermore, since the TS-based approach drastically reduces operator-dependency, it would pave the way to a standardized methodological protocol for LC-MRI analysis and, thus, to its possible clinical application. As already mentioned, LC has been receiving growing attention in recent years for its possible role both in the pathogenesis and pathophysiology of Alzheimer’s Disease (Rorabaugh et al. 2017; Weinshenker et al., 2018), and thus it might even become a target of potential disease-modifying drugs. In such a context, LC-MRI may be used in the future to identify the Alzheimer’s Disease patient phenotype with the highest burden of LC pathology and more likely to benefit from a LC-targeted therapy.

Declarations

Conflict of interest

DDL is presently an employee of Terarecon Inc; his collaboration to the present study occurred before its present affiliation, his contribution to this article reflects entirely and only his own expertise on the matter, and he declares no competing financial interests related to the present article. All the other authors do not have competing interests to disclose concerning the present manuscript.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Neurologie & Psychiatrie

Kombi-Abonnement

Mit e.Med Neurologie & Psychiatrie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

e.Med Neurologie

Kombi-Abonnement

Mit e.Med Neurologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes, den Premium-Inhalten der neurologischen Fachzeitschriften, inklusive einer gedruckten Neurologie-Zeitschrift Ihrer Wahl.

Anhänge

Supplementary Information

Below is the link to the electronic supplementary material.
Literatur
Zurück zum Zitat Baldacci F, Mazzucchi S, dellaVecchia A et al (2020) The path to biomarker-based diagnostic criteria for the spectrum of neurodegenerative diseases. Expert Rev Mol Diagn 20(4):421–441CrossRef Baldacci F, Mazzucchi S, dellaVecchia A et al (2020) The path to biomarker-based diagnostic criteria for the spectrum of neurodegenerative diseases. Expert Rev Mol Diagn 20(4):421–441CrossRef
Zurück zum Zitat Counts SE, Mufson EJ (2012) Locus Coeruleus. In: Paxinos G (ed) Mai JK. The Human Nervous System, Third Edition, pp 427–440 Counts SE, Mufson EJ (2012) Locus Coeruleus. In: Paxinos G (ed) Mai JK. The Human Nervous System, Third Edition, pp 427–440
Metadaten
Titel
Locus Coeruleus magnetic resonance imaging: a comparison between native-space and template-space approach
verfasst von
F. S. Giorgi
N. Martini
F. Lombardo
A. Galgani
L. Bastiani
D. Della Latta
H. Hlavata
C. L. Busceti
F. Biagioni
S. Puglisi-Allegra
N. Pavese
F. Fornai
Publikationsdatum
20.03.2022
Verlag
Springer Vienna
Erschienen in
Journal of Neural Transmission / Ausgabe 4/2022
Print ISSN: 0300-9564
Elektronische ISSN: 1435-1463
DOI
https://doi.org/10.1007/s00702-022-02486-5

Weitere Artikel der Ausgabe 4/2022

Journal of Neural Transmission 4/2022 Zur Ausgabe

Neurology and Preclinical Neurological Studies - Original Article

Novel insights into the effects of levodopa on the up- and downstrokes of writing sequences

Psychiatry and Preclinical Psychiatric Studies - Original Article

Childhood adversity and approach/avoidance-related behaviour in boys

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Stuhltransfusion könnte Fortschreiten von Parkinson-Symptomen bremsen

03.05.2024 Parkinson-Krankheit Nachrichten

Kann eine frühzeitige Stuhltransplantation das Fortschreiten von Parkinson-Symptomen verlangsamen? Die Ergebnisse einer randomisierten Phase-2-Studie scheinen dafür zu sprechen.

Frühe Tranexamsäure-Therapie nützt wenig bei Hirnblutungen

02.05.2024 Hirnblutung Nachrichten

Erhalten Personen mit einer spontanen Hirnblutung innerhalb von zwei Stunden nach Symptombeginn eine Tranexamsäure-Therapie, kann dies weder die Hämatomexpansion eindämmen noch die Mortalität senken.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.