Skip to main content
Erschienen in: Journal of Orthopaedic Science 6/2014

01.11.2014 | Original Article

Long-term clinical results of Charnley total hip arthroplasty using a matte satin-finished stem: a 30-year average follow-up study

verfasst von: Eiji Goto, Tadashi Teranishi, Muneharu Tsuji, Mifumi Ando

Erschienen in: Journal of Orthopaedic Science | Ausgabe 6/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Although 50 years have passed since Charnley started performing total hip arthroplasties, there are relatively few patient studies with a follow-up period of over 30 years. We studied radiograms of patients who had undergone Charnley total hip arthroplasty between 1975 and 1981 and evaluated the results at 26–35 years (mean 30.5 years) after the operation.

Methods

The operations were performed in 87 joints of 82 patients (26 males and 56 females) aged 26–81 years (mean age 56 years) at the time of surgery. A monoblock-type Charnley stem with a 22-mm head was used in all patients. The stem had a matte satin surface finish and a flange or round-back shoulder. The socket was made of ultra-high-density polyethylene without a flange. All operations were performed by one surgeon using the original Charnley method in all patients, excluding the first five.

Results

Thirty years after the operation, 48 patients have died, 5 had an infection, 9 were lost to follow-up, and 20 patients with 24 joints are still alive. In 77 patients (82 joints), after excluding the 5 with infection, the socket and stem survival rates were 54 and 75 % at 30 years after the operation when radiographic loosening or revision surgery was defined as the end point. With revision surgery as the end point, the rates were 68 and 82 %, respectively.

Conclusions

These results were as favorable as those with surgical techniques (including the first-generation cement technique) and implants in the early period. Although new techniques and implants have since been introduced, their long-term results should exceed those in this study. The results of this study should provide a valuable index with which to compare the long-term studies of current total hip arthroplasty.
Literatur
1.
Zurück zum Zitat Charnley J. Low friction arthroplasty of the hip. Theory and practice. Berlin: Springer; 1979.CrossRef Charnley J. Low friction arthroplasty of the hip. Theory and practice. Berlin: Springer; 1979.CrossRef
2.
Zurück zum Zitat Kaplan EL, Meier P. Nonparametric estimation from incomplete observasions. J Am Statist Assn. 1958;53:457–81.CrossRef Kaplan EL, Meier P. Nonparametric estimation from incomplete observasions. J Am Statist Assn. 1958;53:457–81.CrossRef
3.
Zurück zum Zitat Hodgkinson JP, Shelley P, Wroblewski BM. The correlation between the roentogenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop Relat Res. 1988;228:105–9.PubMed Hodgkinson JP, Shelley P, Wroblewski BM. The correlation between the roentogenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop Relat Res. 1988;228:105–9.PubMed
4.
Zurück zum Zitat Harris WH, McGann WA. Loosening of the femoral component after use of the medullary plug cement technique. Follow-up note with a minimum five-year follow-up. J Bone Joint Surg Am. 1986;68(7):1064–6.PubMed Harris WH, McGann WA. Loosening of the femoral component after use of the medullary plug cement technique. Follow-up note with a minimum five-year follow-up. J Bone Joint Surg Am. 1986;68(7):1064–6.PubMed
5.
Zurück zum Zitat Charnley J. The long-term results of low friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br. 1972;54(1):61–76.PubMed Charnley J. The long-term results of low friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br. 1972;54(1):61–76.PubMed
6.
Zurück zum Zitat Sporer SM, Callaghan JJ, Olejniczak BA, Goetz DD, Johnston RC. The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. J Bone Joint Surg Am. 1999;81(4):481–92.PubMed Sporer SM, Callaghan JJ, Olejniczak BA, Goetz DD, Johnston RC. The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. J Bone Joint Surg Am. 1999;81(4):481–92.PubMed
7.
Zurück zum Zitat Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72(4):518–28.PubMed Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72(4):518–28.PubMed
8.
Zurück zum Zitat Ando M, Goto E. The influence of follow-up rate on clinical results of operative treatment. From the follow-up study on total hip replacement. Rinsyou Seikeigeka (Clini Orthop Surg). 1985;20(9):1077–81. Ando M, Goto E. The influence of follow-up rate on clinical results of operative treatment. From the follow-up study on total hip replacement. Rinsyou Seikeigeka (Clini Orthop Surg). 1985;20(9):1077–81.
9.
Zurück zum Zitat Callaghan JJ, Templeton JE, Liu SS, Pedersen DR, Goetz DD, Sullivan PM, Jhonston RC. Results of Charnley total hip arthroplasty at a minimum of thirty years. A concise follow-up of a previous report. J Bone Joint Surg Am. 2004;86(4):690–5.PubMed Callaghan JJ, Templeton JE, Liu SS, Pedersen DR, Goetz DD, Sullivan PM, Jhonston RC. Results of Charnley total hip arthroplasty at a minimum of thirty years. A concise follow-up of a previous report. J Bone Joint Surg Am. 2004;86(4):690–5.PubMed
10.
Zurück zum Zitat Wroblewski BM, Siney PD, Fleming PA. Charnley low friction arthroplasty. Survival patterns to 38 years. J Bone Joint Surg Br. 2007;89(8):1015–8.PubMedCrossRef Wroblewski BM, Siney PD, Fleming PA. Charnley low friction arthroplasty. Survival patterns to 38 years. J Bone Joint Surg Br. 2007;89(8):1015–8.PubMedCrossRef
11.
Zurück zum Zitat Callaghan JJ, Bracha S, Liu SS, Piyaworakhum S, Goetz DD, Johnston RC. Survivorship of a Charnley total hip arthroplasty. A concise follow-up, at a minimum of thirty-five years, of previous reports. J Bone Joint Surg Am. 2009;91(11):2617–20.PubMedCrossRef Callaghan JJ, Bracha S, Liu SS, Piyaworakhum S, Goetz DD, Johnston RC. Survivorship of a Charnley total hip arthroplasty. A concise follow-up, at a minimum of thirty-five years, of previous reports. J Bone Joint Surg Am. 2009;91(11):2617–20.PubMedCrossRef
12.
Zurück zum Zitat Sundfeldt M, Carison LV, Johanson CB, Thomsen P, Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop. 2006;77(2):177–97.PubMedCrossRef Sundfeldt M, Carison LV, Johanson CB, Thomsen P, Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop. 2006;77(2):177–97.PubMedCrossRef
13.
Zurück zum Zitat Schmalzried TP, Kwong LM, Jasty M, Sedlacek RC, Haire TC, O’connor DO, Bragdon CR, Kabo JM, Malcolm AJ, Harris WH. The mechanism of loosening of cemented acetabular components in total hip arthroplasty; analysis of specimens retrieved at autopsy. Clin Orthop Relat Res. 1992;274:60–78.PubMed Schmalzried TP, Kwong LM, Jasty M, Sedlacek RC, Haire TC, O’connor DO, Bragdon CR, Kabo JM, Malcolm AJ, Harris WH. The mechanism of loosening of cemented acetabular components in total hip arthroplasty; analysis of specimens retrieved at autopsy. Clin Orthop Relat Res. 1992;274:60–78.PubMed
14.
Zurück zum Zitat Sochart DH. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res. 1999;363:135–50.PubMedCrossRef Sochart DH. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res. 1999;363:135–50.PubMedCrossRef
15.
Zurück zum Zitat Oparaugo PC, Clarke IC, Malchau H, Herberts P. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene. Acta Orthop Scand. 2001;72(1):22–8.PubMedCrossRef Oparaugo PC, Clarke IC, Malchau H, Herberts P. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene. Acta Orthop Scand. 2001;72(1):22–8.PubMedCrossRef
16.
Zurück zum Zitat Johanson PE, Digas G, Herberts P, Thanner J, Karrholm J. Highly cross-linked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study. Clin Orthop Relat Res. 2012;470:3083–93.PubMedCentralPubMedCrossRef Johanson PE, Digas G, Herberts P, Thanner J, Karrholm J. Highly cross-linked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study. Clin Orthop Relat Res. 2012;470:3083–93.PubMedCentralPubMedCrossRef
17.
Zurück zum Zitat Charnley J. Long-term results of low friction arthroplasty. In: Nelson JP, editor. The Hip. Mosby: St Louis; 1982. p. 42–9. Charnley J. Long-term results of low friction arthroplasty. In: Nelson JP, editor. The Hip. Mosby: St Louis; 1982. p. 42–9.
18.
Zurück zum Zitat Hodgkinson JP, Maskel AP, Paul A. Flanged acetabular component in cemented Charnley hip arthroplasty. J Bone Joint Surg Br. 1993;75(3):464–7.PubMed Hodgkinson JP, Maskel AP, Paul A. Flanged acetabular component in cemented Charnley hip arthroplasty. J Bone Joint Surg Br. 1993;75(3):464–7.PubMed
19.
Zurück zum Zitat Kobayashi S, Terayama K. Radiology of low friction arthroplasty of the hip. A comparison of socket fixation technique. J Bone Joint Surg Br. 1990;72(3):439–43.PubMed Kobayashi S, Terayama K. Radiology of low friction arthroplasty of the hip. A comparison of socket fixation technique. J Bone Joint Surg Br. 1990;72(3):439–43.PubMed
20.
Zurück zum Zitat Ranawat CS, Rawlins BA, Harju VT. Effect of modern cement technique on acetabular fixation total hip arthroplasty. Orthop Clin North Am. 1988;19(3):599–601.PubMed Ranawat CS, Rawlins BA, Harju VT. Effect of modern cement technique on acetabular fixation total hip arthroplasty. Orthop Clin North Am. 1988;19(3):599–601.PubMed
21.
Zurück zum Zitat Okamoto T, Inao S, Goto E, Ando M. Primary Charnley total hip arthroplasty for congenital dysplasia. J Bone Joint Surg Br. 1997;79(1):83–6.PubMedCrossRef Okamoto T, Inao S, Goto E, Ando M. Primary Charnley total hip arthroplasty for congenital dysplasia. J Bone Joint Surg Br. 1997;79(1):83–6.PubMedCrossRef
22.
Zurück zum Zitat Crites BM, Berend ME, Ritter MA. Technical considerations of cemented acetabular components. Clin Orthop Relat Res. 2000;381:114–9.PubMedCrossRef Crites BM, Berend ME, Ritter MA. Technical considerations of cemented acetabular components. Clin Orthop Relat Res. 2000;381:114–9.PubMedCrossRef
23.
Zurück zum Zitat Gilbody J. The case for removing the subchondral bone plate. J Bone Joint Surg Br. 2011;93(4):435–8.PubMedCrossRef Gilbody J. The case for removing the subchondral bone plate. J Bone Joint Surg Br. 2011;93(4):435–8.PubMedCrossRef
24.
Zurück zum Zitat Howie DW, Middleton RG, Costi K. Loosening of matt and polished cemented femoral stem. J Bone Joint Surg Br. 1998;80(4):573–6.PubMedCrossRef Howie DW, Middleton RG, Costi K. Loosening of matt and polished cemented femoral stem. J Bone Joint Surg Br. 1998;80(4):573–6.PubMedCrossRef
25.
Zurück zum Zitat Dall DM, Learmonth ID, Solomon MI, Miles AW, Davenport JM. Fracture and loosening of Charnley femoral stems. Comparison between first-generation and subsequent designs. J Bone Joint Surg Br. 1993;75(2):259–65.PubMed Dall DM, Learmonth ID, Solomon MI, Miles AW, Davenport JM. Fracture and loosening of Charnley femoral stems. Comparison between first-generation and subsequent designs. J Bone Joint Surg Br. 1993;75(2):259–65.PubMed
26.
Zurück zum Zitat Wroblewski BM, Siney PD, Fleming PA, Bobak P. The calcar femorale in cemented stem fixation in total hip arthroplasty. J Bone Joint Surg Br. 2000;82(6):842–5.PubMedCrossRef Wroblewski BM, Siney PD, Fleming PA, Bobak P. The calcar femorale in cemented stem fixation in total hip arthroplasty. J Bone Joint Surg Br. 2000;82(6):842–5.PubMedCrossRef
27.
Zurück zum Zitat Callaghan JJ, Liu SS, Firestone DE, Yehyawi TM, Goetz DD, Sullivan J, Vittetoe DA, O’Rourke MR, Johnston RC. Total hip arthroplasty with cement and use oif a collared matte-finish femoral component. J Bone Joint Surg Am. 2008;90(2):299–306.PubMedCrossRef Callaghan JJ, Liu SS, Firestone DE, Yehyawi TM, Goetz DD, Sullivan J, Vittetoe DA, O’Rourke MR, Johnston RC. Total hip arthroplasty with cement and use oif a collared matte-finish femoral component. J Bone Joint Surg Am. 2008;90(2):299–306.PubMedCrossRef
28.
Zurück zum Zitat Wroblewski BM, Ritj AJ. Intramedullary cancellous bone block to improve femoral stem fixation in the Charnley low friction arthroplasty. J Bone Joint Surg Br. 1984;66(5):639–44.PubMed Wroblewski BM, Ritj AJ. Intramedullary cancellous bone block to improve femoral stem fixation in the Charnley low friction arthroplasty. J Bone Joint Surg Br. 1984;66(5):639–44.PubMed
29.
Zurück zum Zitat Smith SW, Estok DM, Harris WH. Total hip arthroplasty with use of second-generation cementing technique. J Bone Joint Surg Am. 1998;80(11):1632–40.PubMed Smith SW, Estok DM, Harris WH. Total hip arthroplasty with use of second-generation cementing technique. J Bone Joint Surg Am. 1998;80(11):1632–40.PubMed
Metadaten
Titel
Long-term clinical results of Charnley total hip arthroplasty using a matte satin-finished stem: a 30-year average follow-up study
verfasst von
Eiji Goto
Tadashi Teranishi
Muneharu Tsuji
Mifumi Ando
Publikationsdatum
01.11.2014
Verlag
Springer Japan
Erschienen in
Journal of Orthopaedic Science / Ausgabe 6/2014
Print ISSN: 0949-2658
Elektronische ISSN: 1436-2023
DOI
https://doi.org/10.1007/s00776-014-0619-y

Weitere Artikel der Ausgabe 6/2014

Journal of Orthopaedic Science 6/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.