08.09.2017 | Brief Communication

Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta

verfasst von: Eiji Okamoto, Tetsuya Yano, Hidekazu Miura, Yasuyuki Shiraishi, Tomoyuki Yambe, Yoshinori Mitamura

Erschienen in: Journal of Artificial Organs | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Abstract

We have developed various axial flow blood pumps to realize the concept of the Valvo pump, and we have studied hemodynamic changes under cardiac assistance using an axial flow blood pump in series with the natural heart. In this study, we measured hemodynamic changes of not only systemic circulation but also cerebral circulation and coronary circulation under cardiac support using our latest axial flow blood pump placed in the descending aorta in an acute animal experiment. The axial flow blood pump was installed at the thoracic descending aorta through a left thoracotomy of a goat (43.8 kg, female). When the pump was on, the aortic pressure and aortic flow downstream of the pump increased with preservation of pulsatilities. The pressure drop upstream of the pump caused reduction of afterload pressure, and it may lead to reduction of left ventricular wall stress. However, cerebral blood flow and coronary blood flow were decreased when the pump was on. The axial flow blood pump enables more effective blood perfusion into systemic circulation, but it has the potential risk of blood perfusion disturbance into cerebral circulation and coronary circulation. The results indicate that the position before the coronary ostia might be suitable for implantation of the axial flow blood pump in series with the natural heart to avoid blood perfusion disturbances.
Literatur
1.
Zurück zum Zitat Kirklin JK, Naftel DC, Pagani FD, Komos RL, Stevenson LW, Blume ED, Myers SL, Miller MA, Baldwin JT, Young JB. Seventh INTERMACS annual report: 15,000 patients and counting. J Heart Lung Trans. 2013;34:1495–1504.CrossRef Kirklin JK, Naftel DC, Pagani FD, Komos RL, Stevenson LW, Blume ED, Myers SL, Miller MA, Baldwin JT, Young JB. Seventh INTERMACS annual report: 15,000 patients and counting. J Heart Lung Trans. 2013;34:1495–1504.CrossRef
2.
Zurück zum Zitat Yozu R. Circulation apparatus. US Patent No.4994917, 1991. Yozu R. Circulation apparatus. US Patent No.4994917, 1991.
3.
Zurück zum Zitat Mitamura Y, Yozu R, Tanaka T. The valvo-pump: axial nonplusatile blood pump. ASAIO Trans. 1991;37:M510–512.PubMed Mitamura Y, Yozu R, Tanaka T. The valvo-pump: axial nonplusatile blood pump. ASAIO Trans. 1991;37:M510–512.PubMed
4.
Zurück zum Zitat Mitamura Y, Nakamura H, Okamoto E, Yozu R, Kawada S, Kim DW. Development of the Valvo Pump: An axial flow pump implanted at the heart valve position. Artif Org. 1999;23(6):566–71.CrossRef Mitamura Y, Nakamura H, Okamoto E, Yozu R, Kawada S, Kim DW. Development of the Valvo Pump: An axial flow pump implanted at the heart valve position. Artif Org. 1999;23(6):566–71.CrossRef
5.
Zurück zum Zitat Okamoto E, Ishida Y, Yano T, Mitamura Y. Passive magnetic bearing in the 3rd generation miniature axial flow pump-the Valvo pump 2. J Artif Org. 2015;18:181–184.CrossRef Okamoto E, Ishida Y, Yano T, Mitamura Y. Passive magnetic bearing in the 3rd generation miniature axial flow pump-the Valvo pump 2. J Artif Org. 2015;18:181–184.CrossRef
6.
Zurück zum Zitat Okamoto E, Yano T, Shiraishi Y, Miura H, Yambe T, Mitamura Y. Initial acute animal experiment using a new miniature axial flow pump in series with the natural heart. Artif Org. 2015;39:701–704.CrossRef Okamoto E, Yano T, Shiraishi Y, Miura H, Yambe T, Mitamura Y. Initial acute animal experiment using a new miniature axial flow pump in series with the natural heart. Artif Org. 2015;39:701–704.CrossRef
7.
Zurück zum Zitat Reitan O, Steen S, Ohilin H. Hemodynamic effects of a new percutaneous circulatory support device in a left ventricular failure model. ASAIO J. 2003;49:731–6.CrossRefPubMed Reitan O, Steen S, Ohilin H. Hemodynamic effects of a new percutaneous circulatory support device in a left ventricular failure model. ASAIO J. 2003;49:731–6.CrossRefPubMed
8.
Zurück zum Zitat Rezaienia MA, Rahideh A, Rothman MT, Sell SA, Mitchell K, Korakianitis T. In vitro comparison of two different mechanical circulatory support devices installed in series and in parallel. Artif Org. 2014 38:800–809. Rezaienia MA, Rahideh A, Rothman MT, Sell SA, Mitchell K, Korakianitis T. In vitro comparison of two different mechanical circulatory support devices installed in series and in parallel. Artif Org. 2014 38:800–809.
9.
Zurück zum Zitat Rezaienia MA, Rahideh A, Hamedani BA, Bosak DEM, Zustiask S, Korakianitis T. Numerical and in vitro investigation of a novel mechanical circulatory support device installed in descending aorta. Artif Org. 2015;39:502–13.CrossRef Rezaienia MA, Rahideh A, Hamedani BA, Bosak DEM, Zustiask S, Korakianitis T. Numerical and in vitro investigation of a novel mechanical circulatory support device installed in descending aorta. Artif Org. 2015;39:502–13.CrossRef
10.
Zurück zum Zitat Rezaienia MA, Paul G, Avital E, Paul G, Avital E, Rahideh A, Rothman MT, Korakiantitis T. In-vitro investigation of cerebral-perfusion effects of a rotary blood pump installed in the descending aorta. J Biomech. 2016;49:1865–72.CrossRefPubMed Rezaienia MA, Paul G, Avital E, Paul G, Avital E, Rahideh A, Rothman MT, Korakiantitis T. In-vitro investigation of cerebral-perfusion effects of a rotary blood pump installed in the descending aorta. J Biomech. 2016;49:1865–72.CrossRefPubMed
11.
Zurück zum Zitat Guyton G. Physiology of the human body. 6th ed. Philadelphia: Saunders college publishing; 1984. Guyton G. Physiology of the human body. 6th ed. Philadelphia: Saunders college publishing; 1984.
Metadaten
Titel
Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta
verfasst von
Eiji Okamoto
Tetsuya Yano
Hidekazu Miura
Yasuyuki Shiraishi
Tomoyuki Yambe
Yoshinori Mitamura
Publikationsdatum
08.09.2017
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 4/2017
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-017-0985-2

Weitere Artikel der Ausgabe 4/2017

Journal of Artificial Organs 4/2017 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.