Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 3/2014

01.04.2014 | Original Article

Meta-analysis comparing locking plate fixation with hemiarthroplasty for complex proximal humeral fractures

verfasst von: Jiezhi Dai, Yimin Chai, Chunyang Wang, Gen Wen

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 3/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

There remains no consensus on the surgical treatment of complex proximal humeral fractures. In this meta-analysis, we pool available trials to compare the clinical outcomes of locking plate fixation and hemiarthroplasty for this injury.

Methods

A literature search between January 1990 and May 2012 in the main medical search engines (Pubmed, Medline, Embase search, and the Cochrane library) was included. We selected available trials that compared locking plate fixation and hemiarthroplasty in patients with complex proximal humeral fractures and that reported on functional outcomes, revisions, and method-related complications. The quality of the studies was assessed, and meta-analyses were performed with the Cochrane Collaboration’s REVMAN 5.0 software.

Results

A total of 567 patients from 9 trials were included in this meta-analysis (302 fractures treated with locking plate and 265 with hemiarthroplasty). In this comparison, we found that patients with locking plate fixation had better Constant–Murley score than with hemiarthroplasty, and hemiarthroplasty could reduce the rate of revisions and the method-related complications significantly.

Conclusions

Compared with hemiarthroplasty, patients with locking plate fixation could obtain more favorable functional outcomes, but technical detail was critical to minimize the risk of implant failure, avascular necrosis, and re-operation. As the possible significant bias and inconclusive evidence arising from the included trials, further randomized trials and observational studies should be recommended to support these finding.
Literatur
2.
Zurück zum Zitat Lind T, Kroner K, Jensen J (1989) The epidemiology of fractures of the proximal humerus. Arch Orthop Trauma Surg 108(5):285–287PubMedCrossRef Lind T, Kroner K, Jensen J (1989) The epidemiology of fractures of the proximal humerus. Arch Orthop Trauma Surg 108(5):285–287PubMedCrossRef
3.
Zurück zum Zitat Neer CS 2nd (1970) Displaced proximal humeral fractures. II. Treatment of three-part and four-part displacement. J Bone Joint Surg Am 52(6):1090–1103PubMed Neer CS 2nd (1970) Displaced proximal humeral fractures. II. Treatment of three-part and four-part displacement. J Bone Joint Surg Am 52(6):1090–1103PubMed
4.
Zurück zum Zitat Neer CS 2nd (1970) Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg Am 52(6):1077–1089PubMed Neer CS 2nd (1970) Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg Am 52(6):1077–1089PubMed
8.
Zurück zum Zitat Sudkamp N, Bayer J, Hepp P, Voigt C, Oestern H, Kaab M, Luo C, Plecko M, Wendt K, Kostler W, Konrad G (2009) Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. J Bone Joint Surg Am 91(6):1320–1328. doi:10.2106/JBJS.H.00006 PubMedCrossRef Sudkamp N, Bayer J, Hepp P, Voigt C, Oestern H, Kaab M, Luo C, Plecko M, Wendt K, Kostler W, Konrad G (2009) Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. J Bone Joint Surg Am 91(6):1320–1328. doi:10.​2106/​JBJS.​H.​00006 PubMedCrossRef
9.
Zurück zum Zitat Jobin CM, Galatz LM (2012) Proximal humerus fractures: pin, plate, or replace? Semin Arthroplasty 23(2):74–82CrossRef Jobin CM, Galatz LM (2012) Proximal humerus fractures: pin, plate, or replace? Semin Arthroplasty 23(2):74–82CrossRef
11.
Zurück zum Zitat Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J (2003) Methodological index for non-randomized studies (minors): development and validation of a new instrument. ANZ J Surg 73(9):712–716PubMedCrossRef Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J (2003) Methodological index for non-randomized studies (minors): development and validation of a new instrument. ANZ J Surg 73(9):712–716PubMedCrossRef
12.
13.
Zurück zum Zitat Begg CB, Mazumdar M (1994) Operating characteristics of a rank correlation test for publication bias. Biometrics 50(4):1088–1101PubMedCrossRef Begg CB, Mazumdar M (1994) Operating characteristics of a rank correlation test for publication bias. Biometrics 50(4):1088–1101PubMedCrossRef
14.
Zurück zum Zitat Dietrich M, Meier C, Lattmann T, Zingg U, Gruninger P, Platz A (2008) Complex fracture of the proximal humerus in the elderly. Locking plate osteosynthesis vs hemiarthroplasty. Chirurg 79(3):231–240. doi:10.1007/s00104-007-1436-z PubMedCrossRef Dietrich M, Meier C, Lattmann T, Zingg U, Gruninger P, Platz A (2008) Complex fracture of the proximal humerus in the elderly. Locking plate osteosynthesis vs hemiarthroplasty. Chirurg 79(3):231–240. doi:10.​1007/​s00104-007-1436-z PubMedCrossRef
17.
Zurück zum Zitat Wang DL, Ruan DK, Yin Q, Li HF, Wang PJ, He Q (2009) Surgical treatment for complicated proximal humeral fractures and analysis of efficacy. Chin J Bone Joint Injury 24(11):985–987 Wang DL, Ruan DK, Yin Q, Li HF, Wang PJ, He Q (2009) Surgical treatment for complicated proximal humeral fractures and analysis of efficacy. Chin J Bone Joint Injury 24(11):985–987
18.
Zurück zum Zitat Zhang J, Di Z, He Z, Feng J, Xu R (2010) Comparison of humeral head replacement and internal fixation for the treatment of 3 parts and 4 parts fractures of proximal humerus in the elderly]. China J Orthop Traumatol 23(6):435 Zhang J, Di Z, He Z, Feng J, Xu R (2010) Comparison of humeral head replacement and internal fixation for the treatment of 3 parts and 4 parts fractures of proximal humerus in the elderly]. China J Orthop Traumatol 23(6):435
19.
Zurück zum Zitat Kim DS, Lee DK, Yi CH, Park JH, Rah JH (2011) Comparison of results between internal plate fixation and hemiarthroplasty in comminuted proximal humerus fracture. J Korean Fract Soc 24(2):144–150CrossRef Kim DS, Lee DK, Yi CH, Park JH, Rah JH (2011) Comparison of results between internal plate fixation and hemiarthroplasty in comminuted proximal humerus fracture. J Korean Fract Soc 24(2):144–150CrossRef
20.
Zurück zum Zitat Wild JR, DeMers A, French R, Shipps MR, Bergin PF, Musapatika D, Jelen BA (2011) Functional outcomes for surgically treated 3- and 4-part proximal humerus fractures. Orthopedics 34(10):e629–e633. doi:10.3928/01477447-20110826-14 PubMed Wild JR, DeMers A, French R, Shipps MR, Bergin PF, Musapatika D, Jelen BA (2011) Functional outcomes for surgically treated 3- and 4-part proximal humerus fractures. Orthopedics 34(10):e629–e633. doi:10.​3928/​01477447-20110826-14 PubMed
21.
Zurück zum Zitat Lu J, Zhou TM (2012) Comparative research of the outcomes after two different methods for treatment of four-part proximal humerus fractures. J Pract Orthop 18(2):115–117 Lu J, Zhou TM (2012) Comparative research of the outcomes after two different methods for treatment of four-part proximal humerus fractures. J Pract Orthop 18(2):115–117
23.
Zurück zum Zitat Zyto K, Wallace WA, Frostick SP, Preston BJ (1998) Outcome after hemiarthroplasty for three- and four-part fractures of the proximal humerus. J Should Elbow Surg 7(2):85–89CrossRef Zyto K, Wallace WA, Frostick SP, Preston BJ (1998) Outcome after hemiarthroplasty for three- and four-part fractures of the proximal humerus. J Should Elbow Surg 7(2):85–89CrossRef
24.
Zurück zum Zitat van de Water AT, Shields N, Taylor NF (2011) Outcome measures in the management of proximal humeral fractures: a systematic review of their use and psychometric properties. J Should Elbow Surg 20(2):333–343. doi:10.1016/j.jse.2010.10.028 CrossRef van de Water AT, Shields N, Taylor NF (2011) Outcome measures in the management of proximal humeral fractures: a systematic review of their use and psychometric properties. J Should Elbow Surg 20(2):333–343. doi:10.​1016/​j.​jse.​2010.​10.​028 CrossRef
25.
Zurück zum Zitat Nijs S, Broos P (2009) Outcome of shoulder hemiarthroplasty in acute proximal humeral fractures: a frustrating meta-analysis experience. Acta Orthop Belg 75(4):445–451PubMed Nijs S, Broos P (2009) Outcome of shoulder hemiarthroplasty in acute proximal humeral fractures: a frustrating meta-analysis experience. Acta Orthop Belg 75(4):445–451PubMed
26.
Zurück zum Zitat Misra A, Kapur R, Maffulli N (2001) Complex proximal humeral fractures in adults—a systematic review of management. Injury 32(5):363–372PubMedCrossRef Misra A, Kapur R, Maffulli N (2001) Complex proximal humeral fractures in adults—a systematic review of management. Injury 32(5):363–372PubMedCrossRef
28.
Zurück zum Zitat Schliemann B, Siemoneit J, Theisen C, Kosters C, Weimann A, Raschke MJ (2012) Complex fractures of the proximal humerus in the elderly-outcome and complications after locking plate fixation. Musculoskelet Surg 96(Suppl 1):S3–S11. doi:10.1007/s12306-012-0181-8 PubMedCrossRef Schliemann B, Siemoneit J, Theisen C, Kosters C, Weimann A, Raschke MJ (2012) Complex fractures of the proximal humerus in the elderly-outcome and complications after locking plate fixation. Musculoskelet Surg 96(Suppl 1):S3–S11. doi:10.​1007/​s12306-012-0181-8 PubMedCrossRef
30.
Zurück zum Zitat Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, Kohut G, Ekelund A, Muller M, Audige L, Babst R (2009) Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma 23(3):163–172. doi:10.1097/BOT.0b013e3181920e5b PubMedCrossRef Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, Kohut G, Ekelund A, Muller M, Audige L, Babst R (2009) Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma 23(3):163–172. doi:10.​1097/​BOT.​0b013e3181920e5b​ PubMedCrossRef
32.
Zurück zum Zitat Hente R, Kampshoff J, Kinner B, Fuchtmeier B, Nerlich M (2004) Treatment of dislocated 3- and 4-part fractures of the proximal humerus with an angle-stabilizing fixation plate. Unfallchirurg 107(9):769–782. doi:10.1007/s00113-004-0818-7 PubMedCrossRef Hente R, Kampshoff J, Kinner B, Fuchtmeier B, Nerlich M (2004) Treatment of dislocated 3- and 4-part fractures of the proximal humerus with an angle-stabilizing fixation plate. Unfallchirurg 107(9):769–782. doi:10.​1007/​s00113-004-0818-7 PubMedCrossRef
33.
Zurück zum Zitat Helwig P, Bahrs C, Epple B, Oehm J, Eingartner C, Weise K (2009) Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus? A prospective series of 87 patients. Acta Orthop 80(1):92–96PubMedCentralPubMedCrossRef Helwig P, Bahrs C, Epple B, Oehm J, Eingartner C, Weise K (2009) Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus? A prospective series of 87 patients. Acta Orthop 80(1):92–96PubMedCentralPubMedCrossRef
36.
Zurück zum Zitat Fialka C, Stampfl P, Arbes S, Reuter P, Oberleitner G, Vecsei V (2008) Primary hemiarthroplasty in four-part fractures of the proximal humerus: randomized trial of two different implant systems. J Should Elbow Surg 17(2):210–215. doi:10.1016/j.jse.2007.07.002 CrossRef Fialka C, Stampfl P, Arbes S, Reuter P, Oberleitner G, Vecsei V (2008) Primary hemiarthroplasty in four-part fractures of the proximal humerus: randomized trial of two different implant systems. J Should Elbow Surg 17(2):210–215. doi:10.​1016/​j.​jse.​2007.​07.​002 CrossRef
37.
Zurück zum Zitat Kralinger F, Schwaiger R, Wambacher M, Farrell E, Menth-Chiari W, Lajtai G, Hubner C, Resch H (2004) Outcome after primary hemiarthroplasty for fracture of the head of the humerus. A retrospective multicentre study of 167 patients. J Bone Joint Surg Br 86(2):217–219PubMedCrossRef Kralinger F, Schwaiger R, Wambacher M, Farrell E, Menth-Chiari W, Lajtai G, Hubner C, Resch H (2004) Outcome after primary hemiarthroplasty for fracture of the head of the humerus. A retrospective multicentre study of 167 patients. J Bone Joint Surg Br 86(2):217–219PubMedCrossRef
38.
Zurück zum Zitat Greiner SH, Diederichs G, Kroning I, Scheibel M, Perka C (2009) Tuberosity position correlates with fatty infiltration of the rotator cuff after hemiarthroplasty for proximal humeral fractures. J Should Elbow Surg 18(3):431–436. doi:10.1016/j.jse.2008.10.007 CrossRef Greiner SH, Diederichs G, Kroning I, Scheibel M, Perka C (2009) Tuberosity position correlates with fatty infiltration of the rotator cuff after hemiarthroplasty for proximal humeral fractures. J Should Elbow Surg 18(3):431–436. doi:10.​1016/​j.​jse.​2008.​10.​007 CrossRef
39.
Zurück zum Zitat Boileau P, Krishnan SG, Tinsi L, Walch G, Coste JS, Mole D (2002) Tuberosity malposition and migration: reasons for poor outcomes after hemiarthroplasty for displaced fractures of the proximal humerus. J Should Elbow Surg 11(5):401–412CrossRef Boileau P, Krishnan SG, Tinsi L, Walch G, Coste JS, Mole D (2002) Tuberosity malposition and migration: reasons for poor outcomes after hemiarthroplasty for displaced fractures of the proximal humerus. J Should Elbow Surg 11(5):401–412CrossRef
40.
Zurück zum Zitat Mighell MA, Kolm GP, Collinge CA, Frankle MA (2003) Outcomes of hemiarthroplasty for fractures of the proximal humerus. J Should Elbow Surg 12(6):569–577CrossRef Mighell MA, Kolm GP, Collinge CA, Frankle MA (2003) Outcomes of hemiarthroplasty for fractures of the proximal humerus. J Should Elbow Surg 12(6):569–577CrossRef
42.
Zurück zum Zitat DerSimonian R, Laird N (1986) Meta-analysis in clinical trials. Control Clin Trials 7(3):177–188PubMedCrossRef DerSimonian R, Laird N (1986) Meta-analysis in clinical trials. Control Clin Trials 7(3):177–188PubMedCrossRef
43.
Zurück zum Zitat Deeks JJ, Dinnes J, D’Amico R, Sowden AJ, Sakarovitch C, Song F, Petticrew M, Altman DG (2003) Evaluating non-randomised intervention studies. Health Technol Assess 7(27):iii–x, 1–173 Deeks JJ, Dinnes J, D’Amico R, Sowden AJ, Sakarovitch C, Song F, Petticrew M, Altman DG (2003) Evaluating non-randomised intervention studies. Health Technol Assess 7(27):iii–x, 1–173
Metadaten
Titel
Meta-analysis comparing locking plate fixation with hemiarthroplasty for complex proximal humeral fractures
verfasst von
Jiezhi Dai
Yimin Chai
Chunyang Wang
Gen Wen
Publikationsdatum
01.04.2014
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 3/2014
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-013-1179-0

Weitere Artikel der Ausgabe 3/2014

European Journal of Orthopaedic Surgery & Traumatology 3/2014 Zur Ausgabe

General Review

Acrometastases

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.