Skip to main content
Erschienen in: Journal of Cardiothoracic Surgery 1/2013

Open Access 01.12.2013 | Case report

Multiple paravalvular leak 17 years after a second mitral valve replacement

verfasst von: Tae-Eun Jung, Dong-Hyup Lee

Erschienen in: Journal of Cardiothoracic Surgery | Ausgabe 1/2013

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Paravalvular leak (PVL) after prosthetic valve implantation is a significant complication and it usually occurs early in the postoperative period. We report a case of multiple PVL 17 years after the second mitral valve replacement without evidence of infection. The valve sutures were neither cut nor loosened. None of the sewing cuff of the mitral valve was covered with fibrous tissue. The sewing cuff was floated over the native annulus and large and multiple leakage was developed. The valve was easily removed and replaced with a new mechanical prosthesis.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1749-8090-8-24) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

TJ wrote the draft of the manuscript and obtained the written consent. DL performed the literature review and participated in the manuscript writing and helped to the final writing of the paper and gave final approval of the manuscript. All authors have read and approved the final manuscript.

Background

Paravalvular leak (PVL) after prosthetic valve implantation is a significant complication and it usually occurs early in the postoperative period [1]. The patient underwent a mitral valve replacement two times before this operation, which makes this surgery a third-time operation. We report a rare case of multiple PVL 17 years after the second mitral valve replacement without evidence of infection.

Case presentation

A 62-year-old female was admitted due to easy fatigue and dyspnea on exertion. She had undergone mitral valve replacement twice before this admission. The first operation was done with a tissue valve (29 mm, Carpentier-Edwards, Edwards Lifesciences, Irvine, CA, USA) 25 years before this admission. She suffered from degenerative changes in the valve 8 years after the first operation and underwent a redo mitral valve replacement with a mechanical prosthesis (29 mm, St. Jude Medical, Inc. St. Paul, MN, USA). She had been studied by serial transthoracic echocardiography (TTE) for years, but no sign of PVL had ever been detected. One year before the reoperation, when the mild dyspnea was first found, we were able to find the minimal multiple PVL by TTE. She had been treated with medication and her symptoms had improved.
After one year on medication, the patient was slightly icteric. A grade II/IV systolic murmur was heard at the apex. A chest radiograph showed the typical pattern of pulmonary edema and an increased cardiothoracic ratio of 65.0%. Her blood test revealed hemoglobin of 7.9 mg/dL and lactate dehydrogenase of 4,421 IU/L. Total bilirubin was 3.38 mg/dL and direct bilirubin was 0.58 mg/dL. The endoscopic examination did not reveal gastrointestinal bleeding or an ulcer, and the peripheral blood smear was compatible with hemolytic anemia.
TTE revealed severe mitral regurgitation and moderate tricuspid regurgitation. The pulmonary artery pressure was 45 mmHg, and the left ventricular ejection fraction was 56%. Transesophageal echography (TEE) revealed PVL in multiple areas (Figure 1). Mitral regurgitation due to the PVL, causing heart failure and hemolytic anemia, was diagnosed, and we performed repeat open heart surgery for valve replacement.
After a median sternotomy, the pericardium was carefully dissected. A standard cardiopulmonary bypass was established by bicaval cannulation and an aortic cannulation at the distal end of the ascending aorta. Cold blood cardioplegia was delivered with both the antegrade and subsequent retrograde methods. A right atriotomy and atrial septal incision was made for both mitral and tricuspid valve management. None of the sewing cuffs of the mitral valve were covered with fibrous tissue, and the neoendothelialization between the sewing cuff and annulus was not seen. There was no abscess or fragile tissue suggesting prosthetic valve endocarditis. The sutures were neither cut nor loosened. The sewing cuff was floated over the native annulus in multiple areas and lead to paravalvular leakage (Figure 2).
We planned to replace it with a new prosthesis instead of repairing it because the dehiscence sites were multiple and the remaining sutures looked weak. The valve was easily removed (Figure 3) and replaced with a new mechanical prosthesis (27 mm, ATS Medical, Inc.; Minneapolis, MN, USA) in the same annular position. The slightly deep everted mattress sutures were done while avoiding injury of important adjacent tissue. After closing the atrial septum, a tricuspid valve annuloplasty was performed with a ring (30 mm, MC3 ring, Edwards Lifesciences, Irvine, CA, USA). The cross-clamp time was 177 min, and the cardiopulmonary bypass time was 222 min.
The patient’s postoperative course was good, and she was extubated on the next day and transferred to the general ward two days after surgery. Postoperatively, the LDH decreased dramatically to 699 IU/l and the dyspnea was disappeared. TTE showed that the pressure of the right ventricle decreased to 30 mmHg, and there was no PVL. The patient’s postoperative recovery was uneventful, and she was discharged 9 days after surgery.

Discussion

PVL is a rare complication after mitral valve replacement. The incidence of PVL is higher in mechanical valves than bioprosthesis [2]. The reoperation rate due to PVL after use of the Björk-Shiley prosthesis was reported at 2.2% [3] and at 2.5% in the isolated MVR of 372 patients [4]. Lindblom reported that the PVL in the mitral position was 3.5 times higher than in the aortic position in Björk-Shiley prostheses [5]. It occurs most frequently in the early postoperative period. Genoni et al. [1] reported a median time of 119 days (range: 1 day to 23 years) after primary mitral valve replacement in 96 patients.
Once PVL occurs, it may causes morbidity due to hemolytic anemia or heart failure. The most frequent cause of PVL was found to be fragile native tissue, such as is seen with endocarditis. Annular calcification and continuous running sutures in placing a prosthesis are associated with the development of PVL [6].
In our patient, there was no apparent annular calcification, and no stitch loosening or disruption. Furthermore, with the intraoperative findings and laboratory data of this case, an infection did not seem to be the cause. It was uncertain why PVL appeared a long time after second mitral valve replacement.
The only unusual finding was that not all of the entire sewing ring was covered by tissue, which was different than what is usually found in repeat operations and the sewing cuff was floated over the native annulus in multiple areas without cutting or loosening.
Minami et al. [7] proposed three possible causes of late PVL: (1) The suture site of the remnant valve tissue under the sewing cuff could have undergone long-term degenerative calcified change. (2) A small tear might have occurred in the calcified portion, and the accumulated stress on the annulus allowed the small area of detachment. (3) There might have been an “unidentified cured infective process” in the remnant valve tissue. Because we could not find any fibrous tissue growth in the sewing cuff, we thought possible cause of PVL is weakening of the suture site by lack of fibrous tissue between the sewing cuff and annulus tissue.
If the PVL is small and the surrounding tissue is clear, direct suture closure or device closure maybe possible. If the leak is large or in multiple sites, the effective treatment is valve replacement.

Conclusion

Careful follow-up is necessary for PVL in patients who have undergone valve replacement, even if many years ago. We successfully treated a rare case of multiple PVL that was detected 17 years after the second valve replacement.
Written informed consent was obtained from the patient for publication of this case report and accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Acknowledgements

This research was supported by Yeungnam University research grants in 2012.
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

TJ wrote the draft of the manuscript and obtained the written consent. DL performed the literature review and participated in the manuscript writing and helped to the final writing of the paper and gave final approval of the manuscript. All authors have read and approved the final manuscript.
Anhänge

Authors’ original submitted files for images

Literatur
1.
Zurück zum Zitat Genoni M, Franzen D, Vogt P: Paravalvular leakage after mitral valve replacement: improved long-term survival with aggressive surgery?. Eur J Cardiothorac Surg. 2000, 17: 14-19. 10.1016/S1010-7940(99)00358-9.CrossRefPubMed Genoni M, Franzen D, Vogt P: Paravalvular leakage after mitral valve replacement: improved long-term survival with aggressive surgery?. Eur J Cardiothorac Surg. 2000, 17: 14-19. 10.1016/S1010-7940(99)00358-9.CrossRefPubMed
2.
Zurück zum Zitat Hammermeister KE, Sethi GK, Henderson WG, Oprian C, Kim T, Rahimtoola S: A comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis: veterans affairs cooperative study on valvular heart disease. N Engl J Med. 1993, 328: 1289-1296. 10.1056/NEJM199305063281801.CrossRefPubMed Hammermeister KE, Sethi GK, Henderson WG, Oprian C, Kim T, Rahimtoola S: A comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis: veterans affairs cooperative study on valvular heart disease. N Engl J Med. 1993, 328: 1289-1296. 10.1056/NEJM199305063281801.CrossRefPubMed
3.
Zurück zum Zitat Horstkotte D, Korfer R, Seipel L, Bircks W, Loogen F: Late complications in patients with Bjork-Shiley and St. Jude Medical heart valve replacement. Circulation. 1983, 68 (Pt 2): II175-84.PubMed Horstkotte D, Korfer R, Seipel L, Bircks W, Loogen F: Late complications in patients with Bjork-Shiley and St. Jude Medical heart valve replacement. Circulation. 1983, 68 (Pt 2): II175-84.PubMed
4.
Zurück zum Zitat Fernandez G, Deville C, Horovitz S, Thibaud D, Fontan F: Long-term results (6 to 17 years) of 372 mitral valve replacements using the Bjork-Shiley prosthesis. Ann Chir. 1989, 43: 94-98.PubMed Fernandez G, Deville C, Horovitz S, Thibaud D, Fontan F: Long-term results (6 to 17 years) of 372 mitral valve replacements using the Bjork-Shiley prosthesis. Ann Chir. 1989, 43: 94-98.PubMed
5.
Zurück zum Zitat Lindblom D: Long-term clinical results after aortic valve replacement with the Bjork-Shiley prosthesis. J Thorac Cardiovasc Surg. 1988, 95: 658-667.PubMed Lindblom D: Long-term clinical results after aortic valve replacement with the Bjork-Shiley prosthesis. J Thorac Cardiovasc Surg. 1988, 95: 658-667.PubMed
6.
Zurück zum Zitat Dhasmana JP, Blackstone EH, Kirklin JW, Kouchoukos NT: Factors associated with periprosthetic leakage following primary mitral valve replacement: with special consideration of the suture technique. Ann Thorac Surg. 1983, 35: 170-178. 10.1016/S0003-4975(10)61456-7.CrossRefPubMed Dhasmana JP, Blackstone EH, Kirklin JW, Kouchoukos NT: Factors associated with periprosthetic leakage following primary mitral valve replacement: with special consideration of the suture technique. Ann Thorac Surg. 1983, 35: 170-178. 10.1016/S0003-4975(10)61456-7.CrossRefPubMed
7.
Zurück zum Zitat Minami H, Asada T, Gan K: Perivalvular leakage 25 years after initial mitral valve replacement with a Björk-Shiley prosthesis. Gen Thorac Cardiovasc Surg. 2008, 56: 462-464. 10.1007/s11748-008-0275-2.CrossRefPubMed Minami H, Asada T, Gan K: Perivalvular leakage 25 years after initial mitral valve replacement with a Björk-Shiley prosthesis. Gen Thorac Cardiovasc Surg. 2008, 56: 462-464. 10.1007/s11748-008-0275-2.CrossRefPubMed
Metadaten
Titel
Multiple paravalvular leak 17 years after a second mitral valve replacement
verfasst von
Tae-Eun Jung
Dong-Hyup Lee
Publikationsdatum
01.12.2013
Verlag
BioMed Central
Erschienen in
Journal of Cardiothoracic Surgery / Ausgabe 1/2013
Elektronische ISSN: 1749-8090
DOI
https://doi.org/10.1186/1749-8090-8-24

Weitere Artikel der Ausgabe 1/2013

Journal of Cardiothoracic Surgery 1/2013 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.