Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 5/2007

01.10.2007 | Original Paper

Multislice computed tomography coronary angiography in patients admitted with a suspected acute coronary syndrome

verfasst von: Duncan R. Coles, Peter Wilde, Martin Oberhoff, Chris A. Rogers, Karl R. Karsch, Andreas Baumbach

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 5/2007

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The aim of this prospective clinical study was to assess the accuracy and clinical relevance of multislice computed tomography coronary angiography (MSCTCA) in patients presenting with acute chest pain.

Background

Multislice computed tomography coronary angiography has shown ability to detect accurately coronary artery disease (CAD) in selected elective patient groups.

Methods

One hundred and twenty patients presenting with acute chest pain (<24 h) underwent MSCTCA (Siemens Sensation 16) before a scheduled inpatient conventional coronary angiogram (CCA). Exclusion criteria included patients with STEMI, non-sinus rhythm, contraindication to β blockers and renal impairment. Blinded visual assessment of MSCTCA to detect CAD was performed on an 11-segment model. The accuracy of MSCTCA was compared to CCA to detect significant stenoses (≥50%).

Results

One hundred and thirteen patients underwent both investigations. The prevalence of significant CAD was 74%. 1,243 native segments were assessed by MSCTCA. The overall ability of MSCTCA to detect the presence of ≥1 significant stenosis in all native segments had a sensitivity of 92% (95%CI 83–97%), specificity of 55% (95%CI 35–74%), positive predictive value of 86% (95%CI 76–93%) and negative predictive value of 70% (95%CI 47–87%). 22% of all segments (mostly distal) were non-analyzable. Coronary calcification was a major cause of false positivity.

Conclusion

In a prospective study of unselected patients presenting with acute chest pain, the diagnostic accuracy of 16-slice CT coronary angiography was moderate and less than reported from studies in elective patients. The clinical relevance of this technology to screen patients with acute chest pain is limited.
Literatur
1.
Zurück zum Zitat Achenbach S, Ulzheimer S, Baum U et al (2000) Non-invasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102(23):2823–2828PubMed Achenbach S, Ulzheimer S, Baum U et al (2000) Non-invasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102(23):2823–2828PubMed
2.
Zurück zum Zitat Kopp AF, Schroeder S, Kuettner A et al (2002) Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients. Eur Heart J 23(21):1714–1725PubMed Kopp AF, Schroeder S, Kuettner A et al (2002) Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients. Eur Heart J 23(21):1714–1725PubMed
3.
Zurück zum Zitat Nieman K, Cademartiri F, Lemos PA et al (2002) Reliable non-invasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106(16):2051–2054PubMedCrossRef Nieman K, Cademartiri F, Lemos PA et al (2002) Reliable non-invasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106(16):2051–2054PubMedCrossRef
4.
Zurück zum Zitat Ropers D, Baum U, Pohle K et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107(5):664–666PubMedCrossRef Ropers D, Baum U, Pohle K et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107(5):664–666PubMedCrossRef
5.
Zurück zum Zitat Mollet NR, Cademartiri F, Nieman K et al (2004) Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 43(12):2265–2270PubMedCrossRef Mollet NR, Cademartiri F, Nieman K et al (2004) Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 43(12):2265–2270PubMedCrossRef
6.
Zurück zum Zitat Kuettner A, Trabold T, Schroeder S et al (2004) Non-invasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 44(6):1230–1237PubMed Kuettner A, Trabold T, Schroeder S et al (2004) Non-invasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 44(6):1230–1237PubMed
7.
Zurück zum Zitat Morgan-Hughes GJ, Roobottom CA, Owens PE, Marshall AJ (2005) Highly accurate coronary angiography with submillimetre, 16 slice computed tomography. Heart 91(3):308–313PubMedCrossRef Morgan-Hughes GJ, Roobottom CA, Owens PE, Marshall AJ (2005) Highly accurate coronary angiography with submillimetre, 16 slice computed tomography. Heart 91(3):308–313PubMedCrossRef
8.
Zurück zum Zitat Mollet NR, Cademartiri F, Krestin GP et al (2005) Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. J Am Coll Cardiol 45(1):128–132PubMedCrossRef Mollet NR, Cademartiri F, Krestin GP et al (2005) Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. J Am Coll Cardiol 45(1):128–132PubMedCrossRef
9.
Zurück zum Zitat Hoffmann U, Moselewski F, Cury RC et al (2004) Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation 110(17):2638–2643PubMedCrossRef Hoffmann U, Moselewski F, Cury RC et al (2004) Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation 110(17):2638–2643PubMedCrossRef
10.
Zurück zum Zitat Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220(3):712–719PubMedCrossRef Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220(3):712–719PubMedCrossRef
11.
Zurück zum Zitat Hoffmann MHK, Shi H, Schmitz BL et al (2005) Non-invasive coronary angiography with multislice computed tomography. JAMA 293(20):2471–2478PubMedCrossRef Hoffmann MHK, Shi H, Schmitz BL et al (2005) Non-invasive coronary angiography with multislice computed tomography. JAMA 293(20):2471–2478PubMedCrossRef
12.
Zurück zum Zitat Kuettner A, Beck T, Drosch T et al (2005) Diagnostic accuracy of non-invasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol 45(1):123–127PubMedCrossRef Kuettner A, Beck T, Drosch T et al (2005) Diagnostic accuracy of non-invasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol 45(1):123–127PubMedCrossRef
13.
Zurück zum Zitat Achenbach S, Ropers D, Pohle FK et al (2005) Detection of coronary artery stenoses using multi-detector CT with 16 × 0.75 collimation and 375 ms rotation. Eur Heart J 26(19):1978–1986PubMedCrossRef Achenbach S, Ropers D, Pohle FK et al (2005) Detection of coronary artery stenoses using multi-detector CT with 16 × 0.75 collimation and 375 ms rotation. Eur Heart J 26(19):1978–1986PubMedCrossRef
14.
Zurück zum Zitat Kaiser C, Bremerich J, Haller S et al (2005) Limited diagnostic yield of non-invasive coronary angiography by 16-slice multi-detector spiral computed tomography in routine patients referred for evaluation of coronary artery disease. Eur Heart J 26(19):1987–1992PubMedCrossRef Kaiser C, Bremerich J, Haller S et al (2005) Limited diagnostic yield of non-invasive coronary angiography by 16-slice multi-detector spiral computed tomography in routine patients referred for evaluation of coronary artery disease. Eur Heart J 26(19):1987–1992PubMedCrossRef
15.
Zurück zum Zitat Garcia MJ, Lessick J, Hoffmann MHK et al (2006) Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA 296(4):403–411PubMedCrossRef Garcia MJ, Lessick J, Hoffmann MHK et al (2006) Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA 296(4):403–411PubMedCrossRef
16.
Zurück zum Zitat Kuettner A, Kopp AF, Schroeder S et al (2004) Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease. J Am Coll Cardiol 43(5):831–839PubMedCrossRef Kuettner A, Kopp AF, Schroeder S et al (2004) Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease. J Am Coll Cardiol 43(5):831–839PubMedCrossRef
17.
Zurück zum Zitat Cademartiri F, Mollet NR, Runza G et al (2006) Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates. Int J Cardiovasc Imaging 22(1):101–105PubMedCrossRef Cademartiri F, Mollet NR, Runza G et al (2006) Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates. Int J Cardiovasc Imaging 22(1):101–105PubMedCrossRef
18.
Zurück zum Zitat Schmermund A, Erbel R (2005) Non-invasive computed tomographic coronary angiography: the end of the beginning. Eur Heart J 26(15):1451–1453PubMedCrossRef Schmermund A, Erbel R (2005) Non-invasive computed tomographic coronary angiography: the end of the beginning. Eur Heart J 26(15):1451–1453PubMedCrossRef
19.
Zurück zum Zitat Garcia S, Canoniero M, Peter A, de Marchena E, Ferreira A (2004) Correlation of TIMI risk score with angiographic severity and extent of coronary artery disease in patients with non-ST-elevation acute coronary syndromes. Am J Cardiol 93(7):813–816PubMedCrossRef Garcia S, Canoniero M, Peter A, de Marchena E, Ferreira A (2004) Correlation of TIMI risk score with angiographic severity and extent of coronary artery disease in patients with non-ST-elevation acute coronary syndromes. Am J Cardiol 93(7):813–816PubMedCrossRef
20.
Zurück zum Zitat Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and non-obstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46(1):147–154PubMedCrossRef Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and non-obstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46(1):147–154PubMedCrossRef
21.
Zurück zum Zitat Leschka S, Alkadhi H, Plass A et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26(15):1482–1487PubMedCrossRef Leschka S, Alkadhi H, Plass A et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26(15):1482–1487PubMedCrossRef
22.
Zurück zum Zitat Raff GL, Gallagher MJ, O’Neill WW et al (2005) Diagnostic accuracy of non-invasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol Aug 2; 46(3):552–557 Raff GL, Gallagher MJ, O’Neill WW et al (2005) Diagnostic accuracy of non-invasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol Aug 2; 46(3):552–557
23.
Zurück zum Zitat Coles DR, Smail MA, Negus IS et al (2006) Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol 47(9):1840–1845PubMedCrossRef Coles DR, Smail MA, Negus IS et al (2006) Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol 47(9):1840–1845PubMedCrossRef
Metadaten
Titel
Multislice computed tomography coronary angiography in patients admitted with a suspected acute coronary syndrome
verfasst von
Duncan R. Coles
Peter Wilde
Martin Oberhoff
Chris A. Rogers
Karl R. Karsch
Andreas Baumbach
Publikationsdatum
01.10.2007
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 5/2007
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-006-9193-5

Weitere Artikel der Ausgabe 5/2007

The International Journal of Cardiovascular Imaging 5/2007 Zur Ausgabe

Die „Zehn Gebote“ des Endokarditis-Managements

30.04.2024 Endokarditis Leitlinie kompakt

Worauf kommt es beim Management von Personen mit infektiöser Endokarditis an? Eine Kardiologin und ein Kardiologe fassen die zehn wichtigsten Punkte der neuen ESC-Leitlinie zusammen.

Strenge Blutdruckeinstellung lohnt auch im Alter noch

30.04.2024 Arterielle Hypertonie Nachrichten

Ältere Frauen, die von chronischen Erkrankungen weitgehend verschont sind, haben offenbar die besten Chancen, ihren 90. Geburtstag zu erleben, wenn ihr systolischer Blutdruck < 130 mmHg liegt. Das scheint selbst für 80-Jährige noch zu gelten.

Dihydropyridin-Kalziumantagonisten können auf die Nieren gehen

30.04.2024 Hypertonie Nachrichten

Im Vergleich zu anderen Blutdrucksenkern sind Kalziumantagonisten vom Diyhdropyridin-Typ mit einem erhöhten Risiko für eine Mikroalbuminurie und in Abwesenheit eines RAS-Blockers auch für ein terminales Nierenversagen verbunden.

Frauen bekommen seltener eine intensive Statintherapie

30.04.2024 Statine Nachrichten

Frauen in den Niederlanden erhalten bei vergleichbarem kardiovaskulärem Risiko seltener eine intensive Statintherapie als Männer. Ihre LDL-Zielwerte erreichen sie aber fast ähnlich oft.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.