Open Access 24.10.2017 | Sleep Breathing Physiology and Disorders • Original Article

Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea

verfasst von: Anders Storesund, Anders Johansson, Bjørn Bjorvatn, Sverre Lehmann

Erschienen in: Sleep and Breathing | Ausgabe 2/2018

Abstract

Background

Studies show that the therapeutic CPAP pressure is associated with oral appliance (OA) treatment outcome in obstructive sleep apnea (OSA) patients. However, these studies included either CPAP adherent patients using fixed pressure devices, or partly CPAP non-adherent patients using fixed pressure or auto-adjusting (auto-CPAP) devices. In many countries, auto-CPAP is predominately used, and only those non-adherent to therapy need a change to OA. Therefore, studies examining the relationship between CPAP pressures and OA treatment outcome should focus on patients non-adherent to auto-CPAP.

Purpose

The purpose of this paper is to assess if CPAP pressures predicted OA treatment outcome in patients non-adherent to auto-CPAP therapy.

Methods

The OA treatment responders and non-responders were defined by two success criteria ((1) AHI < 5; (2) 5 ≤ AHI < 10 and > 50% AHI reduction). Logistic regression analyses were performed for CPAP pressures and baseline variables. ROC curve analyses were used to identify CPAP pressure cutoff values, alone and combined with other explanatory variables, predicting the OA treatment outcome.

Results

Eighty-seven patients with moderate or severe OSA were included. Maximum CPAP pressures (CPAPmax) were higher in non-responders by both criteria and were, together with baseline AHI, associated with the OA treatment outcome in multivariate regression analyses. ROC curves identified an optimal CPAPmax cutoff of 12 cm H2O, corresponding to a positive predictive value (PPV) of 0.85 in predicting non-response using criterion 1. A prediction model combining CPAPmax > 12 and baseline AHI ≥ 30 had a PPV of 1.0 for non-response by both criteria.

Conclusions

Maximum CPAP pressure was a moderate predictor of OA treatment outcome, but combined with baseline AHI, the ability to identify OA non-responders was high.

Introduction

Obstructive sleep apnea (OSA) is a common condition in which the upper airways intermittently collapse during sleep, causing partial or total cessation of airflow. This results in fragmentation of sleep and oxygen desaturations and is associated with neurocognitive impairment and an increased risk of cardiovascular disease and all-cause mortality [1, 2]. The prevalence of OSA in a large Norwegian adult population has been estimated to 8% for AHI ≥ 15 [3]. Such findings imply that OSA could have an effect on public health. Continuous positive airway pressure (CPAP) has been considered as the gold standard treatment, as it alleviates obstruction, and is shown to reduce the negative consequences of OSA [4]. However, the patient adherence is often poor, reducing the efficacy of CPAP [5]. Oral appliance (OA) is a device that maintains the upper airways patency preventing collapse and is a treatment alternative to CPAP in mild to moderate OSA, or when CPAP treatment fails [6]. OA is in general inferior in terms of reducing OSA parameters based on polysomnography [7], and around one third of these patients will have minimal improvement [8]. Nevertheless, OA treatment might be as effective as CPAP in mild to moderate sleep apnea, if titrated sufficiently [9]. Furthermore, OA adherence may be higher than for CPAP suggesting similar health outcomes on a group level for the two treatment modalities [10]. Thus, predictors of the OA treatment response are desired, preferably using unsophisticated measurements that are available as part of the daily clinical practice.
Various clinical and polysomnographic characteristics, like younger age, female gender, less obesity, position dependent OSA, and lower AHI, have been reported to correlate with OA treatment success [1113]. The results, however, may be difficult to implement in a clinical setting, as they are not always consistent [12, 13], and because they rarely propose cutoff levels that precisely discriminate responders from non-responders, but merely lend support to the decision making when selecting therapy.
The pressure data from previous CPAP therapy is easily accessible. A therapeutic CPAP pressure > 10.5 cm H2O has been associated with OA treatment failure in a Japanese population [14], whereas a CPAP pressure ≥ 13 cm H2O predicted treatment failure in Australian patients [15]. In a Canadian study, a therapeutic CPAP pressure ≤ 9 cm H2O was associated with OA treatment success [16]. The two former studies selected data from fixed pressure CPAP users with acceptable adherence, whereas the latter study included both fixed pressure and auto-CPAP users, with 50% of the subjects non-tolerant to previous CPAP. In Norway, as in many other countries, the vast majority of subjects with moderate and severe OSA start with auto-adjusting CPAP machines, and only the non-adherent cases are in need of modality change to a second line treatment, such as OA.
Thus, we sought to assess the relationship between the delivered auto-CPAP pressures and the OA treatment response in a Norwegian sleep clinic population, among patients with moderate and severe OSA, all non-adherent to CPAP.

Material and methods

Patients

In this retrospective study, the patients were consecutively recruited from the Center for Sleep Medicine at the Haukeland University Hospital, Bergen, Norway, as described in a previous paper [17]. In brief, inclusion criteria were patients diagnosed with moderate or severe obstructive sleep apnea, non-adherent to CPAP therapy and subsequently treated with oral appliance. Non-adherence was defined as less than 4 h usage per night during a period of at least 3 months [18]. Exclusion criteria were central sleep apnea and contraindications to oral appliance therapy (e.g., poor dental status).

Study protocol

The study protocol was approved by the Regional Committees for Medical and Health Research Ethics (number 2015/2225). All subjects had a sleep study performed at baseline before starting CPAP and attended the follow-up appointment including a new sleep study using the OA. Data on body mass index (BMI) and AHI were retrieved from the patients’ medical records and sleep polygraphy, retrospectively.

Respiratory polygraphic evaluation

The baseline diagnosis of OSA and follow-up investigations were performed by respiratory medicine specialists or ENT specialists at the Departments of Thoracic Medicine and Otolaryngology at Haukeland University Hospital, Bergen, Norway, supported by a medical examination that included polygraphy (Embletta™, Resmed Ltd., Australia or NOX-T3®, Nox Medical, Iceland). Scoring rules were in accordance with the 2007 American Academy of Sleep Medicine manual [19].

CPAP

All patients were treated with Resmed CPAP devices in the Autoset mode. The initial pressure settings were 4–20 cm H2O. CPAP compliance, expressed as the mean number of hours and minutes machine use every 24 h, and delivered CPAP pressures were recorded using CPAP software (ResScan, ResMed Corp. San Diego, CA, USA). The mean value (cm H2O) of the maximum CPAP pressures (CPAPmax) from each treatment session was used in the subsequent analyses. The software from ResMed auto-CPAP machines has exhibited a good diagnostic accuracy to identify residual sleep apnea, delivered pressure and mask leakage curves [20].

Oral appliance

Maxillary and mandibular impressions and an occlusal protrusive wax or silicone index using George Gauge bite fork™ were made for all subjects, with a baseline fitting index at 50–80% of maximum protrusive capacity. The majority of patients received a titrable twin-block oral appliance while a few subjects were treated with monoblock appliances [17]. The first evaluation of subjective treatment effect was performed 4–8 weeks after starting OA. If not satisfactory, titrations were performed until positive subjective effect or until maximum adjustments had been done, after which an overnight polygraphy was performed.

Defining treatment outcome

Two different criteria were applied when defining successful outcome with oral appliance: criterion 1 AHI < 5 and criterion 2 5 ≤ AHI < 10 and > 50% reduction from baseline.

Statistical analysis

Comparisons between the OA outcome groups were made using student’s t test or Mann-Whitney U test for continuous variables, and chi-square test or Fisher’s exact test for categorical variables. Normality was assessed using the Shapiro-Wilk test. Anthropometrical and polygraphic data associated with the OA treatment outcomes from univariate analyses were added to the delivered CPAP pressures as explanatory variables in multivariate logistic regression models. Receiver operating characteristic (ROC) curve analyses were performed to identify CPAP pressure values with the highest sensitivity and specificity related to the OA treatment outcome. Other variables associated with OA failure from the multivariate regression models were added to CPAP pressures in the ROC curves, to assess their combined predictive utility. P values less than 0.05 were considered statistically significant. IBM SPSS (Statistics for Windows, version 23.0, IBM Corp., Armonk, NY, USA) was used for statistical analyses.

Results

During the years 2007–2013, a total of 116 patients (68% males), predominantly Caucasians, were identified with a baseline diagnosis of moderate (75%) or severe OSA, who had received OA treatment due to CPAP non-adherence. Among these, 29 patients (25%) were lost to follow up for various reasons: 17 subjects had no available CPAP data, 7 did not show up for follow-up appointment, 3 died, and 2 had their follow-up elsewhere, leaving 87 patients to be included in the final analyses. Among the 87 patients, 30% had severe OSA. The patients lost to follow up did not differ from those included in this study, whose baseline and CPAP pressure characteristics are described in Table 1. The reasons for discontinuing CPAP are shown in Table 2.
Table 1
Anthropometrical, polygraphic, and CPAP data for all patients and according to oral appliance treatment outcome
 
All patients
Criterion 1 AHI < 5
Criterion 2 5 ≤ AHI < 10 and > 50% AHI reduction
Responders
Non-responders
Responders
Non-responders
Number
87
31
56
56
31
Sex (male/female)
59/28
21/10
38/18
37/19
22/9
Age (years)
56.7 ± 11.7
55.5 ± 8.7
57.4 ± 13.1
55.3 ± 11.1
59.3 ± 12.5
BMI (kg/m2)
28.6 ± 4.2
28.2 ± 3.8
28.8 ± 4.4
28.7 ± 3.9
28.5 ± 4.7
OSA, severity (moderate/severe)
61/26
25/6
36/20
44/12*
17/14
AHI, baseline
23.8 (19.6–32.2)
20.8 (18.0–26.0)*
24.8 (20.3–39.1)
21.2 (18.2–26.9)**
28.3 (22.4–45.5)
AHI, oral appliance
6.9 (4.0–13.7)
3.1 (1.4–4.1)**
10.9 (7.1–20.0)
4.9 (3.0–6.8)***
18.2 (13.5–30.6)
AHI, CPAP
3.8 (1.9–7.7)
3.1 (0.8–9.3)
4.4 (2.2–7.7)
3.4 (2.0–5.6)
5.5 (1.6–10.7)
Maximum CPAP pressure, cm H2O
11.2 ± 2.8
10.1 ± 2.9*
11.7 ± 2.6
10.5 ± 2.6**
12.3 ± 2.9
Data are presented as numbers, mean ± standard deviation or median (25–75%)
BMI, body mass index; OSA, obstructive sleep apnea; AHI, apnea-hypopnea index; CPAP, continuous positive airway pressure
*p < 0.05 responders versus non-responders; **p < 0.01 responders versus non-responders; ***p < 0.001 responders versus non-responders
Table 2
Reasons for discontinuation of continuous positive airway pressure (CPAP)
 
No. (%) (n = 87)
Noise or discomfort of machine
26 (30)
Claustrophobia
20 (23)
Insomnia
17 (19)
Side effects (e.g., headache, sinusitis)
12 (14)
Practical issues (e.g., travelling, power supply)
6 (7)
Tears it off during sleep
4 (5)
Unknown
2 (2)
The treatment success rates were 36% by criterion 1 and 64% by criterion 2. The CPAP median usage time (hours/night) (25–75 percentile) for all subjects was 1.2 (0.5–2.2) and did not differ between the outcome groups by any criterion (results not shown).
The OA non-responders had significantly higher CPAPmax than responders (Table 1). Using univariate logistic regression analyses, the CPAPmax was a predictor of the OA outcome by both success criteria, with an odds ratio [95% CI] = 1.25 [1.04–1.49] by criterion 1 and 1.30 [1.07–1.58] by criterion 2. When adjusted for other baseline variables in multivariate regression analyses, CPAPmax retained its ability to discriminate responders from non-responders (Table 3).
Table 3
Oral appliance treatment outcome predicted by maximum CPAP pressure (cm H2O), anthropometrical data, and polygraphic variables. Multivariate logistic regression analyses
 
Criterion 1 AHI < 5
Criterion 2 5 ≤ AHI < 10 and > 50% AHI reduction
p
Odds ratio (95% CI)
p
Odds ratio (95% CI)
Sex
0.74
0.83 (0.28–2.48)
0.86
1.11 (0.34–3.64)
Age
0.35
1.02 (0.98–1.07)
0.05
1.05 (1.00–1.10)
BMI
0.43
1.05 (0.93–1.18)
0.99
1.00 (0.88–1.13)
AHI, baseline
0.02
1.07 (1.01–1.13)
0.001
1.09 (1.04–1.14)
CPAP maximum pressure
0.02
1.27 (1.05–1.55)
0.006
1.38 (1.10–1.74)
BMI, body mass index; AHI, apnea-hypopnea index; CPAP, continuous positive airway pressure
Calculating the ROC curves for CPAPmax by criterion 1 and 2, the areas under the curve indicated moderate ability to discriminate between responders and non-responders (Fig. 1). Negative and positive predictive values, as well as likelihood ratios were calculated for different CPAP cutoff pressures (Table 4). Using criterion 1, a 12 cm H2O cutoff had a positive predictive value of 0.85 in predicting non-responders, involving 39% of the study population. No such cutoff pressure was identified by criterion 2, even though a CPAPmax > 14 cm H2O correctly classified a larger proportion of the study population.
Table 4
The ability of different maximum CPAP pressure levels to discriminate oral appliance treatment responders from non-responders
AUC (95% CI)
Criterion 1 AHI < 5
Criterion 2 5 ≤ AHI < 10 and > 50% AHI reduction
0.65 (0.53–0.77)*
0.66 (0.54–0.78)*
Cutoff, cm H2O
> 10
> 11
> 12
> 13
> 14
> 10
> 11
> 12
> 13
> 14
Sensitivity
0.75
0.64
0.41
0.23
0.16
0.81
0.68
0.48
0.32
0.26
Specificity
0.32
0.58
0.87
0.90
0.94
0.32
0.50
0.79
0.89
0.95
PPV
0.67
0.74
0.85
0.82
0.82
0.40
0.43
0.56
0.63
0.73
NPV
0.42
0.47
0.45
0.40
0.38
0.75
0.74
0.73
0.70
0.70
LR+
1.11
1.53
3.18
2.58
2.49
1.19
1.35
2.26
3.01
4.82
LR−
0.78
0.62
0.68
0.83
0.90
0.60
0.65
0.66
0.76
0.78
% correctly classified
60.0
62.1
57.5
48.3
43.7
49.4
56.3
68.9
68.9
70.1
AUC, Area under curve; CI, confidence interval; PPV, positive predictive value; NPV, negative predictive value; LR+, positive likelihood ratio; LR-, negative likelihood ratio; * p < 0.05
Baseline AHI had significant predictive value by both criteria (Tables 1 and 3). By adding the baseline AHI to the CPAPmax in a simple prediction model, the ROC AUC (95% CI) increased to 0.70 (0.59–0.81, p = 0.002) and 0.73 (0.61–0.85, p < 0.001) by criterion 1 and 2, respectively (Fig. 1).
A prediction model using a CPAPmax > 12 cm H2O and baseline AHI ≥ 30 as cutoff values had a positive predictive value (PPV) of 1.0 for OA non-response both by criterion 1 and criterion 2 (Table 5).
Table 5
Positive predictive values for OA treatment failure combining maximum CPAP pressure and baseline AHI by criterion 1 AHI < 5 and criterion 2 5 ≤ AHI < 10 and > 50% AHI reduction (C1/C2)
  
AHI at baseline
≥ 20
≥ 25
≥ 30
≥ 35
≥ 40
Maximum CPAP pressure (H2O)
> 10
0.74/0.50
0.81/0.62
0.82/0.65
0.92/0.77
0.91/0.82
> 11
0.81/0.54
0.91/0.73
0.92/0.85
1.00/0.91
1.00/1.00
> 12
0.95/0.67
1.00/0.86
1.00/1.00
1.00/1.00
1.00/1.00
> 13
0.92/0.75
1.00/0.89
1.00/1.00
1.00/1.00
1.00/1.00
> 14
1.00/0.88
1.00/1.00
1.00/1.00
1.00/1.00
1.00/1.00

Discussion

In this study, we sought to investigate the relationship between auto-CPAP pressures and OA treatment outcome in moderate to severe obstructive sleep apnea patients all non-adherent to CPAP treatment. Our findings indicate that the pressures delivered from auto-CPAP machines were associated with the subsequent OA treatment outcome. Combining the easily available maximum pressure data from the CPAP software with the AHI from the baseline respiratory polygraphy, cutoff values with high predictive values for OA treatment failure were identified.
The results are in accordance with the findings in the previously mentioned studies [1416]. However, as in the Canadian study [16], the correlation between CPAP pressures and OA treatment outcome was not as strong as reported in the Japanese and Australian populations [14, 15]. There might be several reasons for this.
First, we have to consider the possible effect of the differences in the pressure modes used. All patients in the present study used CPAP in auto pressure mode, whereas fixed pressure CPAP was applied for treatment in the Japanese and Australian studies. The fixed pressure level was defined either by manual in-laboratory titration [14] or the 95th percentile pressure from auto-CPAP [15] and confirmed to be therapeutic with polysomnography. In the Canadian study [16], the pressure data were retrieved from a variety of commercially available CPAP machines, mainly of auto-adjusting type, using the 90th percentile pressure. Auto-CPAP devices adjust the treatment pressure based on feedback from various patient measures (airflow, pressure fluctuations, measures of airway resistance), applying the lowest effective pressure to splint the airways open. The mode takes into account the pressure variation during sleep over a given period of time. A single-night titration, determining the fixed pressure requirements either manually or by auto-CPAP, may be affected by an inadequate sampling of sleep position and quality [21]. Studies comparing the different modes in respect to pressure levels have shown that the therapeutic pressures are lower using an automatic mode [22]. The therapeutic pressure requirements also vary with the CPAP manufacturer and device algorithm [21]. Consequently, the differences in the pressures reported in various publications may depend on the choice of CPAP study design.
Second, in the Australian and Japanese studies [14, 15], the inclusion criteria comprised adherence to CPAP, indicating that the participants were able to sleep most of the night during treatment. Thus, breathing cessations demanding higher therapeutic pressures will occur more frequently in the CPAP adherent, sleeping patient compared to the partially awake patient struggling with mask and machine acceptance. In our study, all patients were non-adherent to CPAP therapy. However, this does not necessarily mean that they were truly non-compliant. The reasons for discontinuing CPAP treatment were diverse, some of which might relate to high pressure levels, whereas others could be “pressure independent,” e.g., lack of motivation. To receive reimbursement for OA therapy in Norway, non-adherence to previous CPAP therapy is required, which might contribute to a higher fraction of unmotivated CPAP users, using the machine for only a short period of time mostly being awake. One might speculate how this would affect the CPAP pressures recorded, most likely reducing the pressure variations.
Third, the two studies [14, 15] also included patients with mild sleep apnea in addition to moderate and severe disease, as opposed to our study, which included only patients with moderate or severe sleep apnea. Still, the baseline AHI was higher in both studies, indicating a wider range of AHI, with more patients in each end of the severity scale. An elevated AHI at baseline is associated with an increased risk of OA treatment failure [23]. Baseline AHI has also been included in mathematical equations to predict the CPAP pressure needed to alleviate airway obstruction; the higher the baseline AHI, the higher the therapeutic CPAP pressure [24]. Consequently, the pressure difference observed between responders and non-responders could be more pronounced in the referred studies than in our population.
The study populations also differ in other ways. The Japanese population had a lower BMI and included only males [14], whereas the Australian population was younger [15], compared to the present study. In the Canadian study [16], the patients were in many respects similar to ours. Accordingly, different patient selection might explain the moderate result variation between studies examining the relationship concerning CPAP pressures and OA treatment efficacy.
Sleep apnea is a heterogeneous disorder with several phenotypes related to anatomical and non-anatomical factors [25, 26]. Reliable and simple methods for identification of these phenotypes could allow for future customized therapy [26]. However, given the diverse nature of OSA and based on the findings in this and previous studies [1113], it seems unlikely that a single clinical or polysomnographic variable is sufficient to predict OA treatment outcome for every patient. A combination of several characteristics might have better predictive ability. Such models should be clinically applicable and aim for a high percentage of correctly classified treatment outcomes. This has been addressed in a previous study, which used models based on patient characteristics and OSA phenotypes [13]. However, no reliable prediction tool was found, and the authors concluded that other prediction methods were needed. A different approach could be to develop models that reliably identify a subset of the OA non-responders, i.e., models with high predictive value for OA non-response. In that way, other effective treatment strategies for these patients would be initiated earlier, saving health care resources. In a prospective study of moderate OSA patients, a combination of Mallampati score of class 4 and BMI > 24 had high predictive value for OA non-response [27]. Using these cutoff levels, about 30% of all non-responders were identified. This coincides with our results. A prediction model combining the maximum CPAP pressures and baseline AHI seemed to identify a phenotypic trait not responding to OA, predicting treatment failure with high accuracy. Other methods that examine the change of upper airways dimensions during mandibular advancement, either by sleep monitoring with the simultaneous use of a remotely controlled mandibular positioner or by endoscopic evaluation, have shown promising results [28, 29], but are invasive and operator dependent and time and cost consuming.
There are other definitions of CPAP adherence than the one used in this study, e.g., ≥ 4 h/night in ≥ 70% of nights [5]. What constitutes optimal use is not known. There seems to be a dose-response relationship between CPAP use and clinical outcome, implying that there is a lower threshold for the duration of therapy, below which the treatment effects disappear [4, 5]. Still, some patients who would otherwise be considered as CPAP non-adherent may profit on usage of shorter duration, without the need for treatment change [18]. Thus, the level of adherence must always be compared to the clinical effect. For the majority to benefit from treatment; however, the CPAP should be used most of the time asleep [30]. A cutoff of at least 4 h use per night has proven valid for various outcome measures [18, 30].
There are limitations and strengths to our study. The data were retrieved retrospectively, making room for bias. However, the information was collected from consecutive patients, using CPAP software and medical records, i.e., reliable sources. The Center for Sleep Medicine in the present study serves as a single regional center, which in addition to diagnosing OSA, also includes initiation of therapy and subsequent follow-up of all patients, even if they initially were evaluated by private health care providers. Thus, the patient assortment should be representative for the diagnosed OSA population. In Norway, CPAP is still the first line of treatment for all severity levels of OSA, and patients get their OA expenses reimbursed only if they fail CPAP therapy. These factors reduce the risk of selection bias.
In conclusion, this study shows that high CPAP maximum pressures are associated with subsequent OA treatment failure in non-compliant auto-CPAP users suffering from moderate to severe OSA. The predictive ability was further improved when pressure was combined with the baseline AHI, reflecting disease severity. A prediction model using a combination of CPAP maximum pressure > 12 cm H2O and a baseline AHI ≥ 30 as cutoff values had very high predictive values in identifying OA non-responders, but needs prospective validation.

Funding

This study was partly funded by the Norwegian Competence Center for Sleep Disorders and by Chiesi Pharma AB. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

Compliance with ethical standards

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
For this type of study formal consent is not required.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Dent – Das Online-Abo der Zahnmedizin

Online-Abonnement

Mit e.Dent erhalten Sie Zugang zu allen zahnmedizinischen Fortbildungen und unseren zahnmedizinischen und ausgesuchten medizinischen Zeitschriften.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Gottlieb DJ, Yenokyan G, Newman AB, O’Connor GT, Punjabi NM, Quan SF, Redline S, Resnick HE, Tong EK, Diener-West M, Shahar E (2010) Prospective study of obstructive sleep apnea and incident coronary heart disease and heart failure: the sleep heart health study. Circulation 122 (4):352–360. https://doi.org/10.1161/CIRCULATIONAHA.109.901801 Gottlieb DJ, Yenokyan G, Newman AB, O’Connor GT, Punjabi NM, Quan SF, Redline S, Resnick HE, Tong EK, Diener-West M, Shahar E (2010) Prospective study of obstructive sleep apnea and incident coronary heart disease and heart failure: the sleep heart health study. Circulation 122 (4):352–360. https://​doi.​org/​10.​1161/​CIRCULATIONAHA.​109.​901801
2.
Zurück zum Zitat Marshall NS, Wong KK, Cullen SR, Knuiman MW, Grunstein RR (2014) Sleep apnea and 20-year follow-up for all-cause mortality, stroke, and cancer incidence and mortality in the Busselton Health Study cohort. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 10(4):355–362. https://doi.org/10.5664/jcsm.3600 Marshall NS, Wong KK, Cullen SR, Knuiman MW, Grunstein RR (2014) Sleep apnea and 20-year follow-up for all-cause mortality, stroke, and cancer incidence and mortality in the Busselton Health Study cohort. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 10(4):355–362. https://​doi.​org/​10.​5664/​jcsm.​3600
4.
Zurück zum Zitat Antic NA, Catcheside P, Buchan C, Hensley M, Naughton MT, Rowland S, Williamson B, Windler S, McEvoy RD (2011) The effect of CPAP in normalizing daytime sleepiness, quality of life, and neurocognitive function in patients with moderate to severe OSA. Sleep 34(1):111–119CrossRefPubMedPubMedCentral Antic NA, Catcheside P, Buchan C, Hensley M, Naughton MT, Rowland S, Williamson B, Windler S, McEvoy RD (2011) The effect of CPAP in normalizing daytime sleepiness, quality of life, and neurocognitive function in patients with moderate to severe OSA. Sleep 34(1):111–119CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Ramar K, Dort LC, Katz SG, Lettieri CJ, Harrod CG, Thomas SM, Chervin RD (2015) Clinical practice guideline for the treatment of obstructive sleep apnea and snoring with oral appliance therapy: an update for 2015. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 11(7):773–827. https://doi.org/10.5664/jcsm.4858 Ramar K, Dort LC, Katz SG, Lettieri CJ, Harrod CG, Thomas SM, Chervin RD (2015) Clinical practice guideline for the treatment of obstructive sleep apnea and snoring with oral appliance therapy: an update for 2015. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 11(7):773–827. https://​doi.​org/​10.​5664/​jcsm.​4858
8.
Zurück zum Zitat Sutherland K, Vanderveken OM, Tsuda H, Marklund M, Gagnadoux F, Kushida CA, Cistulli PA (2014) Oral appliance treatment for obstructive sleep apnea: an update. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 10(2):215–227. https://doi.org/10.5664/jcsm.3460 Sutherland K, Vanderveken OM, Tsuda H, Marklund M, Gagnadoux F, Kushida CA, Cistulli PA (2014) Oral appliance treatment for obstructive sleep apnea: an update. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 10(2):215–227. https://​doi.​org/​10.​5664/​jcsm.​3460
10.
Zurück zum Zitat Phillips CL, Grunstein RR, Darendeliler MA, Mihailidou AS, Srinivasan VK, Yee BJ, Marks GB, Cistulli PA (2013) Health outcomes of continuous positive airway pressure versus oral appliance treatment for obstructive sleep apnea: a randomized controlled trial. Am J Respir Crit Care Med 187(8):879–887. https://doi.org/10.1164/rccm.201212-2223OC CrossRefPubMed Phillips CL, Grunstein RR, Darendeliler MA, Mihailidou AS, Srinivasan VK, Yee BJ, Marks GB, Cistulli PA (2013) Health outcomes of continuous positive airway pressure versus oral appliance treatment for obstructive sleep apnea: a randomized controlled trial. Am J Respir Crit Care Med 187(8):879–887. https://​doi.​org/​10.​1164/​rccm.​201212-2223OC CrossRefPubMed
11.
Zurück zum Zitat Marklund M, Stenlund H, Franklin KA (2004) Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Chest 125(4):1270–1278CrossRefPubMed Marklund M, Stenlund H, Franklin KA (2004) Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Chest 125(4):1270–1278CrossRefPubMed
13.
Zurück zum Zitat Sutherland K, Takaya H, Qian J, Petocz P, Ng AT, Cistulli PA (2015) Oral appliance treatment response and polysomnographic phenotypes of obstructive sleep apnea. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 11(8):861–868. https://doi.org/10.5664/jcsm.4934 Sutherland K, Takaya H, Qian J, Petocz P, Ng AT, Cistulli PA (2015) Oral appliance treatment response and polysomnographic phenotypes of obstructive sleep apnea. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 11(8):861–868. https://​doi.​org/​10.​5664/​jcsm.​4934
15.
Zurück zum Zitat Sutherland K, Phillips CL, Davies A, Srinivasan VK, Dalci O, Yee BJ, Darendeliler MA, Grunstein RR, Cistulli PA (2014) CPAP pressure for prediction of oral appliance treatment response in obstructive sleep apnea. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 10(9):943–949. https://doi.org/10.5664/jcsm.4020 Sutherland K, Phillips CL, Davies A, Srinivasan VK, Dalci O, Yee BJ, Darendeliler MA, Grunstein RR, Cistulli PA (2014) CPAP pressure for prediction of oral appliance treatment response in obstructive sleep apnea. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 10(9):943–949. https://​doi.​org/​10.​5664/​jcsm.​4020
16.
Zurück zum Zitat Dort LC, Savard N, Dort E, Dort M, Dort J (2016) Does CPAP pressure predict treatment outcome with oral appliances? J Dent Sleep Med 03(04):113–117CrossRef Dort LC, Savard N, Dort E, Dort M, Dort J (2016) Does CPAP pressure predict treatment outcome with oral appliances? J Dent Sleep Med 03(04):113–117CrossRef
18.
Zurück zum Zitat Weaver TE, Maislin G, Dinges DF, Bloxham T, George CF, Greenberg H, Kader G, Mahowald M, Younger J, Pack AI (2007) Relationship between hours of CPAP use and achieving normal levels of sleepiness and daily functioning. Sleep 30(6):711–719CrossRefPubMedPubMedCentral Weaver TE, Maislin G, Dinges DF, Bloxham T, George CF, Greenberg H, Kader G, Mahowald M, Younger J, Pack AI (2007) Relationship between hours of CPAP use and achieving normal levels of sleepiness and daily functioning. Sleep 30(6):711–719CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Berry RB, Budhiraja R, Gottlieb DJ, Gozal D, Iber C, Kapur VK, Marcus CL, Mehra R, Parthasarathy S, Quan SF, Redline S, Strohl KP, Davidson Ward SL, Tangredi MM, American Academy of Sleep M (2012) Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. Deliberations of the sleep apnea definitions task force of the American Academy of Sleep Medicine Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine 8 (5):597–619. doi:https://doi.org/10.5664/jcsm.2172 Berry RB, Budhiraja R, Gottlieb DJ, Gozal D, Iber C, Kapur VK, Marcus CL, Mehra R, Parthasarathy S, Quan SF, Redline S, Strohl KP, Davidson Ward SL, Tangredi MM, American Academy of Sleep M (2012) Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. Deliberations of the sleep apnea definitions task force of the American Academy of Sleep Medicine Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine 8 (5):597–619. doi:https://​doi.​org/​10.​5664/​jcsm.​2172
21.
Zurück zum Zitat Morgenthaler TI, Aurora RN, Brown T, Zak R, Alessi C, Boehlecke B, Chesson AL Jr, Friedman L, Kapur V, Maganti R, Owens J, Pancer J, Swick TJ, Standards of Practice Committee of the A, American Academy of Sleep M (2008) Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report. Sleep 31(1):141–147PubMed Morgenthaler TI, Aurora RN, Brown T, Zak R, Alessi C, Boehlecke B, Chesson AL Jr, Friedman L, Kapur V, Maganti R, Owens J, Pancer J, Swick TJ, Standards of Practice Committee of the A, American Academy of Sleep M (2008) Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report. Sleep 31(1):141–147PubMed
28.
Zurück zum Zitat Kastoer C, Dieltjens M, Oorts E, Hamans E, Braem MJ, Van de Heyning PH, Vanderveken OM (2016) The use of remotely controlled mandibular positioner as a predictive screening tool for mandibular advancement device therapy in patients with obstructive sleep apnea through single-night progressive titration of the mandible: a systematic review. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 12(10):1411–1421. https://doi.org/10.5664/jcsm.6202 Kastoer C, Dieltjens M, Oorts E, Hamans E, Braem MJ, Van de Heyning PH, Vanderveken OM (2016) The use of remotely controlled mandibular positioner as a predictive screening tool for mandibular advancement device therapy in patients with obstructive sleep apnea through single-night progressive titration of the mandible: a systematic review. J Clin Sleep Med: JCSM : Off Publ Am Acad Sleep Med 12(10):1411–1421. https://​doi.​org/​10.​5664/​jcsm.​6202
Metadaten
Titel
Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea
verfasst von
Anders Storesund
Anders Johansson
Bjørn Bjorvatn
Sverre Lehmann
Publikationsdatum
24.10.2017
Verlag
Springer International Publishing
Erschienen in
Sleep and Breathing / Ausgabe 2/2018
Print ISSN: 1520-9512
Elektronische ISSN: 1522-1709
DOI
https://doi.org/10.1007/s11325-017-1578-2

Weitere Artikel der Ausgabe 2/2018

Sleep and Breathing 2/2018 Zur Ausgabe

Sleep Breathing Physiology and Disorders • Review

Sleep-disordered breathing in patients with neuromuscular disease

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.