Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 2/2022

Open Access 14.06.2021 | Original Article

Orbital floor fractures: epidemiology and outcomes of 1594 reconstructions

verfasst von: Lukas Benedikt Seifert, Tim Mainka, Carlos Herrera-Vizcaino, Rene Verboket, Robert Sader

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 2/2022

Abstract

Objective

The aim of this study was to retrospectively review the midface and orbital floor fractures treated at our institution with regard to epidemiological aspects, surgical treatment options and postoperative complications and discuss this data with the current literature.

Study design

One thousand five hundred and ninety-four patients with midface and orbital fractures treated at the Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery of the Goethe University Hospital in Frankfurt (Germany) between 2007 and 2017 were retrospectively reviewed. The patients were evaluated by age, gender, etiology, fracture pattern, defect size, surgical treatment and complications.

Results

The average patient age was 46.2 (± 20.8). Most fractures (37.5%) occurred in the age between 16 and 35. Seventy-two percent of patients were male while 28% were female. The most common cause of injury was physical assault (32.0%) followed by falls (30.8%) and traffic accidents (17.0%). The average orbital wall defect size was 297.9 mm2 (± 190.8 mm2). For orbital floor reconstruction polydioxanone sheets (0.15 mm 38.3%, 0.25 mm 36.2%, 0.5 mm 2.8%) were mainly used, followed by titanium meshes (11.5%). Reconstructions with the 0.15 mm polydioxanone sheets showed the least complications (p < 0.01, r = 0.15). Eighteen percent of patients who showed persistent symptoms and post-operative complications: 12.9% suffered from persistent hypoesthesia, 4.4% suffered from post-operative diplopia and 3.9% showed intra-orbital hematoma.

Conclusion

Results of the clinical outcome in our patients show that 0.15 mm resorbable polydioxanone sheets leads to significantly less post-operative complications for orbital floor defects even for defects beyond the recommended 200 mm2.

Introduction

Epidemiological studies involving 600 hospitals in Germany from the TraumaNetzwerk DGU® reported from a pooled number of patients of 102,887, that 11,451 (11.1%) suffered from facial trauma [1]. The orbit is especially susceptible to injury because of its very complex anatomical structure with hard and soft tissue. Blunt trauma in this facial region may cause an isolated orbital “blowout” fracture or a combined orbital fracture and midface fracture [2]. Today, there are a variety of classifications for midface fractures which include fractures of the orbit [35]. However, only the recently introduced AO classification for facial fractures permits a very precise description of the orbital injury pattern [5]. Depending on the type of fracture, patients can suffer from a variety of complications. Incarceration of the surrounding soft tissue (Fig. 1) can result in limitations of ocular movement [6], Diplopia [7] or enophthalmos. Another frequent complication is the irritation of the infraorbital nerve which runs in close proximity of the orbit and can result in temporary or permanent infraorbital hypoesthesia [8]. Furthermore, a retrobulbar hematoma can lead to a reduced or total loss of vision [9]. In addition to the clinical parameters, the computer tomography (Fig. 1) presents the gold standard to confirm the diagnosis [10].
The indication for a surgical intervention is controversially discussed throughout the last years. [11]. There is a general agreement that an acute loss of the visual function in the presence of a retrobulbar hematoma, severe enophthalmos, incarceration of peribulbar soft tissue and large defect sizes over 50% of the orbital floor require immediate surgical intervention to restore the anatomical structure of the orbit and improve the visual function as well as the orbital appearance [1214].
There are a variety of surgical approaches to reconstruct the orbit. The infraorbital, the subcilliary and the transconjunctival incision are commonly used whereby last is often recommended in the literature [1518]. For a long time, autologous bone grafts were seen as the gold standard [19] to reconstruct the orbital floor. However, the unpredictable resorption rate as well as the missing optimal volume reconstruction led to the increasing use of resorbable alloplastic biomaterials, such as poly-p-dioxanon (PDS®) [20] (Fig. 2) and polyglactin (Ethisorb®) [21] and non-resorbable alloplastic materials, such as the titanium mesh (Fig. 3), which today can be individually preformed to the patients anatomy in a CAD-CAM process [22, 23].
There is a still a controversy about which material is suited best for orbital floor reconstruction regarding the post-operative outcome. In 2003, Ellis and Tan were the first to show that titanium meshes are more accurate in orbital reconstruction compared to bone grafts [24]. Other retrospective studies supported their results [25, 26]. Later Ellis and Messo estimated that titanium meshes are better suited to reconstruct the orbit compared to alloplastic materials, such as Teflon® or PDS® membranes, due to their incomplete degradation process which can result in sterile inflammation and development of granulomas [27]. On the other hand, it has been reported that titanium meshes cause inflammatory reactions [28] as well and are associated with significantly more post-operative complications, such as infections, extrusion and residual diplopia [29]. In 2002, Baumann et al. concluded that PDS® membranes (0.25 mm or 0.5 mm) should only be used up to a defect size of 2.5 cm2 because of the high risk of developing enophthalmos due to the instability of the membrane [30]. Other authors extended this indication and could show that 0.25 mm PDS® membranes were suitable even for larger defects (median 4.32 cm2) without significantly more complications, [20, 31] Unfortunately, none of the aforementioned studies included more than 78 patients which could be a limitation to their statistical power. To our knowledge, there is only one study that included more than 500 patients [32]. In their retrospective study, Holtmann et al. found that the use of 0.15 mm PDS® membranes resulted in the best post-operative outcome for defect sizes between 250 and 300 mm2 [32].
The present literature is still divided regarding which material should preferably be used to reconstruct the orbit since no material only has advantages. Furthermore, it is unclear up to which defect size which material should be used. Therefore, the primary aim of this study was to retrospectively analyze different materials i.e. PDS® membranes (0.15 mm; 0.25 mm; 0.5 mm) and titanium meshes in a large number of patients (1594) to evaluate which material could be recommended for which defect size. A secondary goal was to analyze and discuss the existing data with regard to epidemiological aspects, surgical treatment options and postoperative complications with the current literature.

Methods

Study design and methods

A retrospective study with a collective of 1874 patients with isolated or combined orbital fractures that were treated at the Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery, University Hospital Frankfurt, Germany in the years between 2007 and 2017 was conducted. Patients were diagnosed after clinical examination and radiological evaluation. Two hundred eighty (280) patients which were treated conservatively were excluded from the study, which resulted in 1594 included patients. Data was extracted from the internal patient management program “Orbis” from Agfa® HealthCare GmbH (Bonn, Germany) and included pre- and post-operative radiological data, surgical documentation, follow-up clinical documentation, pre- and post-operative ophthalmological consultations. Target parameters included patient age and gender, time and causation of the accident, pre-operative clinical symptoms, such as hypoesthesia or diplopia, time between accident and treatment, type of fracture (isolated vs. combined), defect size, type of surgical incision, type of reconstruction material (0.15 mm, 0.25 mm, 0.5 mm polydioxanone sheets or titanium mesh) and the number of pre-, peri- and post-operative complications, such as retrobulbar hematoma, diplopia, hypoesthesia, visual impairment, displacement of the reconstruction material, infections and others. Typically, patients were followed up in the first four weeks after discharge and finally three months after discharge.
The size of the orbital floor defect was calculated according to Ellis and Ten [24] by measuring the widest range of the defect in the coronal slices of the CT scans multiplied with the number of slices in which the defect was still visible and the layer thickness of the coronal slices (Fig. 2).
The study was approved by the ethical board of the University Hospital Frankfurt with the trial registration number 391/18 and carried out under the regulations of the Declaration of Helsinki.

Statistical analysis

Patient data were anonymized and transferred into Microsoft Excel® (Microsoft Corporation, Redmond WA, USA, Version 16.35 for Mac). Statistical analysis was carried out using GraphPad Prism 8 for Mac, Version 8.4.2 (San Diego CA, USA). A statistically significant correlation between the collected parameters was tested using simple linear regression. Effect sizes were calculated according to Cohen [33]. An r value of < 0.10 was regarded as weak, < 0.30 as intermediate and > 0.50 as strong effect. Data collection and statistical analysis were carried out by one of the authors of this study.

Results

Patient collective

Overall, 1594 patients that were surgically treated because of an isolated or combined orbital fracture in the years between 2007 and 2017 were included in the study. Patients median age was 42.5 years (SD = 20.8 years), 37.5% of patients were in the age between 15 and 35 years. Younger patient age correlated positively with smaller defect sizes (p ≤ 0.001; r = 0.106; n = 1198). Four-hundred-forty-four patients were female (28%) while 1150 patients were male (72%). There was a positive correlation between the male gender (p ≤ 0.001; r = 0.34; n = 1594) and a younger patient age (p ≤ 0.001; r = 0.34; n = 1594) and physical assault as the cause of injury. Older patient age strongly correlated with accident or falls as the cause of injury (p ≤ 0.001; r = 0.58; n = 1594). The most common causes of injury were physical assault (32.0%, n = 511), followed by falls (30.8%, n = 491), traffic accidents (17.0%, n = 272), sport injuries (6.5%, n = 104), injuries during work (5.3%, n = 85) and polytrauma (1.8%, n = 29).

Preoperative clinic

In 74.2% (n = 1182) of patients, no preoperative symptoms (excluding pain) were recorded. Most often hypoesthesia was described by 13% (n = 208) of patients, followed by diplopia (7%, n = 112), anisocoria (2.3%, n = 36) and visual impairment of the affected eye (1.2%, n = 19). Eleven patients were admitted to the clinic with a retrobulbar hematoma (0.7%, n = 11) and six patients (0.4%) presented an exophthalmos. Combined fractures patients correlated positively with the occurrence of preoperative symptoms (p = 0.003; r = 0.13; n = 416) and patients that had symptoms prior to surgery also were more likely to have postoperative complications (p = 0.011; r = 0.29; n = 75).

Fracture morphology

Sixty-two percent (n = 987) of patients presented orbital fractures combined with other facial fractures while 38% (n = 601) presented isolated orbital fractures. In six cases, it was not possible to collect data due to a lack of documentation. Positive correlations between the occurrence of combined fractures and traffic accidents as a cause of injury (p ≤ 0.001; r = 0.1914; n = 1486) as well as with male gender (p = 0.018; r = 0.05948; n = 1486) could be observed. In 40% (n = 630) of fractures a prolapse of orbital soft tissue occurred. The possibility of a prolapse and entrapment of soft tissue increased with the occurrence of a combined fracture (p ≤ 0.001; r = 0.32; n = 1495). The average defect size was 297.8 mm2 (SD = 190.8 mm2, min = 5.47mm2, max = 1500mm2). The prolapse of soft tissue occurred more frequently as the defect size increased (p ≤ 0.001; r = 0.1642; n = 1123) and showed a positive correlation with the period between the accident event and the operation (p = 0.026; r = 0.06613; n = 1135).

Operative procedure

On average, surgery was performed 6.4 days after the injury. With increasing patient age, a longer time between injury and surgical treatment was observed (p ≤ 0.001; r = 0.1369; n = 1469), which was mostly related to existing co-morbidities in elder patients. Post-operative complications were more likely when the time between injury and surgical treatment increased (p = 0.007; r = 0.07102; n = 1458).
The trans-conjunctival incision was (83%, n = 1323) the most commonly used approach to the orbit, followed by the infra-orbital incision (5.5%, n = 83), which was mainly used in more severe cases and the medial eyebrow incision (5%, n = 79). In twenty-nine patients (1.8%), an already existing wound was used for an incision. In 43 patients (2.7%), it was not possible to determine which type of incision had been selected due to a lack of data. The infra-orbital approach was significantly chosen more often with increasing patient age (p ≤ 0.001; r = 0.1698; n = 1551).

Reconstruction Material.

In 38.3% (n = 611), the 0.15 mm PDS® membrane was used to reconstruct the orbital floor defects, followed by the 0.25 mm PDS® membrane (36.2%, n = 577) and the titanium mesh (11.5%, n = 184). The 0.5 mm PDS® membrane was only used in forty-five patients (2.8%). In 2.6% (n = 41) a combination of titanium mesh and PDS® membrane was used. In 5.1% of cases, no data were recorded because of missing documentation. On average, the 0.15 mm PDS® membrane was used for a mean defect size of 225.17 mm2 (min = 31.5 mm2, max = 750.0, SD = 151.5 mm2), the 0.25 mm PDS® membrane for 278.5 mm2 (min = 44.6 mm2, max = 1019.0 mm2, SD = 157.6 mm2) and the 0.5 mm PDS® membrane for 282.0 mm2 (min = 68.3 mm2, max = 750.0 mm2, SD = 182.2 mm2). The average defect size for a titanium mesh was 455.2 mm2 (min = 64.7 mm2, max = 1371.2 mm2, SD = 196.0 mm2). The use of the 0.15 mm PDS® membrane correlated with significantly less postoperative complications (p < 0.001; r = 0.1932; n = 1492), in contrast, the use of a titanium mesh correlated with more postoperative complications (p < 0.001; r = 0.1763; n = 1492). With increasing defect size, the use of the 0.25 mm PDS® membrane and the titanium mesh increased (p < 0.001; r = 0.4015; n = 1135).

Postoperative complications.

In total, 18% (n = 296) of patients presented post-operative complications (Table 1). Most frequently patients presented post-operative hypesthesia (12.9%, n = 206), diplopia (4.1%, n = 66), followed by intra-orbital hematoma (4.0%, n = 62) and displacement of the used reconstruction material (2.1%, n = 34). Twenty-five patients with intra-orbital hematomas required drainage and underwent a second operation. Furthermore, twenty patients (1.2%) presented an exophthalmos and eleven patients (0.6%) presented a permanently reduced eyesight after surgery. With increasing defect size, a post-operative complication was more likely (p < 0.001; r = 0.1703; n = 1187). The infra-orbital incision showed a higher risk of post-operative complications (p = 0.002; r = 0.0761; n = 305), such as reduced vision (p = 0.028; r = 0.05511; n = 305) and retrobulbar hematoma (p = 0.009; r = 0.06531; n = 305). Moreover, thirty-six patients (2.2%) developed other post-operative complications that were not directly related to the surgery, such as urinary tract infections, pneumonia or hypertensive crisis.
Table 1
Results of the statistical analysis between the collected parameters
Parameter
Age
Gender
Defect size
Type of accident
Fracture morphology
Postoperative complications
Reconstruction material
Time between accident and surgery
Type of incision
Age
  
 < 0.001
 < 0.001
0.29
 < 0.001
0.025
 < 0.001
 < 0.001
Gender
  
0.131
 < 0.001
0.018
    
Defect size
 < 0.001
0.131
 
0.365
0.056
 < 0.001
 < 0.001
0.026
 
Type of accident
 < 0.001
 < 0.001
0.365
 
 < 0.001
    
Fracture morphology
0.29
0.018
0.056
 < 0.001
 
0.021
 < 0.001
  
Postoperative complications
 < 0.001
 
 < 0.001
 
0.021
 
0.059
0.618
0.0014
Reconstruction material
0.025
 
 < 0.001
 
 < 0.001
0.059
   
Time between accident and surgery
 < 0.001
 
0.026
  
0.618
   
Type of incision
 < 0.001
    
0.0014
   
P values < 0.05 were regarded as statistically significant
Bold headings are used for significant correlations

Discussion

This retrospective study was conducted on 1594 patients who had been operatively treated for orbital floor fractures between 2007 and 2017 at the Department of Oral and Maxillofacial and facial plastic Surgery of the Goethe University Hospital in Frankfurt (Germany). The primary goal of this study was to evaluate which reconstruction material would be best suited for which type and size of orbital floor fracture. A secondary goal was to analyze and discuss the existing data with regard to epidemiological aspects, surgical treatment options and postoperative complications with the current literature.
In the course of the demographic change in most western societies and the increasing number of multimorbid patients, a rigorous patient selection and indication for surgical treatment become more important. Factors, such as age and diabetes mellitus [34, 35], cardio-pulmonary disease [36] and anti-coagulant medication, can significantly increase the risk of post-operative complications and nosocomial infections [37]. In our patient collectively, thirty-six patients (2.2%) developed post-operative symptoms associated with urinary tract infections, pneumonia or hypertension. More than halve of these patients were older than 75 years. Moreover, the risk of domestic falls increases with age [38] which is reflected by the data of our study. Twenty-three percent of our patients were older than 65 years and with patient age the average size of the defect also significantly increased, which could be related to loss of bone elasticity with increasing age. Interestingly, no significant correlation could be found between patient age and post-operative complications in our study which can be an indication for a good patient selection for surgical treatment especially in elder people.
Generally orbital floor fractures can be treated conservatively or operatively. The indication for the latter is still being debated in the present literature. However, it is undisputed that certain symptoms, such as an enophtalmus > 2 mm, a defect size > 1 cm2, a severe dislocation of fragments, a limited motility of the bulb with double vision or a prolapse and incarceration of orbital soft tissue must be treated operatively [3942]. The defect size (> 1 cm2) is most often used as an indication for surgery. In our patient collective only fifty-four (3.4%) presented defect sizes < 1 cm2 which corresponds to the current recommendations.
The ideal time of surgical intervention is still being debated in the present literature. Burnstine et al. distinguished between an intermediate intervention which should be carried out in case of an early enophthalmos with facial asymmetry with signs of a bulbo-cardial reflex or decreased vision of the affected eye and an early intervention within the first 14 days which should be carried out in case of significant lowering of the affected eye, hypoesthesia of the infraorbital nerve, defect sizes > 1 cm2 and double-vision with radiological signs of soft tissue incarceration [43]. This recommendation is also reflected in the present guidelines of the German Society of Oral and Maxillofacial Surgery [44]. Early intervention is recommended by most authors since it is associated with significantly less post-operative complications, such as diplopia or enophthalmos [42, 4448]. Nevertheless, the decline of soft tissue swelling which usually takes place within five to seven days should be awaited. In the present study, the average time between trauma and operation was 6.46 days (SD = 11). Interestingly, we could observe a significant correlation between the time between trauma and operation and post-operative complications which support the current literature and guidelines that recommend an early intervention. A possible explanation for this correlation could be, that older patients in our cohort were operated significantly later after trauma due to co-morbidities and these patients also had significantly bigger defect sizes, which can result in more post-operative complications.
The vast majority (77.5%, n = 1236) of our patients was treated with PDS® membranes (0.15 mm; n = 614; 0.25 mm; n = 577; 0.5 mm; n = 45). Hiding et al. were the first to postulate certain requirements for the ideal reconstruction material like easy handling, good plasticity, natural resorption and sufficient stability and found that PDS® membranes meet most of these criteria. They also found that the degradation of PDS® membranes is associated with an inflammatory reaction and the development a scar tissue that stabilizes the defect after complete resorption within six months [49]. Most authors recommend the use of a PDS membrane only up to a defect size of 200 mm2 and argue that the scar tissue could be insufficient in stabilizing bigger defects which could result in more post-operative complications [30, 39]. In our study, the average defect sizes for 0.15 mm and 0.25 mm PDS membranes were 225,17 mm2 and 278.5 mm2, respectively, which surpasses the general recommendations. The biggest defect that was treated with a 0.25 mm PDS membrane measured more than 1019 mm2 and 750 mm2 for a 0.5 mm PDS membrane. However, none of those patients presented post-operative complications. Since the reconstruction with the 0.15 mm membrane was associated with significantly less post-operative complications (p ≤ 0.001; r = 0.1932; n = 1492) it can be recommended as alternative for orbital floor defects beyond the 2 cm2 which can be found in the current literature.
For bigger (> 300 mm2) or instable fractures that include the medial or lateral orbital wall, titanium meshes are generally recommended in the literature [24, 42, 50]. Their rigidity makes them ideal for more complex fractures, and today, pre-bent or CAD-CAM individualized titanium meshes are easy to insert [51]. In our study, 184 patients (11%) were reconstructed using a titanium mesh. Ellis and Tan were the first to show that titanium meshes are an accurate material for orbital reconstruction compared to bone grafts and present a high bio-compatibility to bone tissue [24]. However, there are studies and case reports that associate titanium with hyper sensory and even allergic reactions [52]. Sugar et al. (1992) listed foreign body reactions, complications when inserting or explanting and frequent infections as some of the disadvantages of titanium meshes. We also could observe significantly more post-operative complications in patients that were treated with a titanium mesh compared to the patients that were reconstructed using a PDS® membrane. However, it has to be taken into account that titanium meshes were more often used for bigger and instable fractures (median 421.6 mm2) and defect size significantly correlated with post-operative complications. Although not implemented in our patients collective, an additional alloplastic implant that requires consideration for the treatment of large defects, is porous high-density polyethylene (Medpor) [53]. However, this material has also been associated to complications [54]. Randomized and controlled studies that investigate the use of different reconstruction materials for equal size defects are needed, to investigate whether complications are related to the reconstruction material or to the size of the defect alone.
The surgical incision should allow a sufficient overview of the operation area without leaving functional and esthetic impairment [42]. The trans-conjunctival incision was by far (83%, n = 1323) the most commonly used approach to the orbit in the present study. Critics of this approach say that it is associated with a reduced overview of the operation area and that it leads to more complications, such as lower eye lid ulceration, entropium and epiphora [55]. In the present study, the complication rate associated with the trans-conjunctival approach was 0.4% and therefore regarded as very low, which is in line with previous studies that also found low complications rates and recommend this approach especially for younger patients because of the ideal esthetic results [56, 57]. However, it should be noted that complications, such as entropium and epiphora, must be regarded as long-term complications and therefore might not be detected because of the three-month clinical follow-up. The infra-orbital incision was rarely used (5.5%, n = 83) in the present study because of the visible post-operative scar even though there are studies that report an equal esthetic outcome of the this approach compared to the transconjunctival approach [55]. However, the infra-orbital incision showed a significantly higher risk of post-operative complications, even though the effect was rather weak, so that we would recommend this approach only for emergency treatment where a wide overview of the operation area has to established in short time.
In the present study, a complication rate of 18% was found. In the literature, an interval of complication rates between 1.8% and 44% is given [14, 5860]. Consequently, a comparatively low rate could be observed in the present study. Moreover, the definition of a post-operative complication in the literature differ widely from severe complications, such as a retrobulbar hematoma to frequent complications, such as post-operative hypesthesia, which explains the wide the range of complication rates published. In this study, the occurrence of post-operative hypesthesia was the most common postoperative complication with 206 cases (12.9%) which is comparatively low to the incidence that is reported in the literature with an interval between 5 and 33% [47, 50]. It should be mentioned that the hypoesthesia specified here was observed and documented during the clinical follow-up within three months. In the literature, depending on the injury pattern, regeneration of neural tissue is generally only expected after 2 weeks to 6 months [61] which permits the assumption that some of these cases a restitutio ad integrum could be expected.
Within the patient collective, a prolapse of the peribulbar soft tissue into the maxillary sinus was observed in 40% of the cases (n = 630). On the one hand, this can indicate a “blow-out” fracture in which the volume of the orbital funnel is increased. On the other hand, a prolapse, which is shown as a “hanging drop” in the CT scan, can also be caused by an incarceration of fat or muscle tissue. Independent of the mechanisms, the results show that enophthalmos can appear until days or weeks after the accident or treatment. This is because swelling or a developed hematoma can hide a decrease in volume of the orbital funnel.
In this study, too, corresponding to existing results, a preoperative retro- or infraorbital hematoma in 11 cases (0.7%) and an exophthalmos in six cases (0.4%) could be observed, which are rare spontaneous symptoms after trauma. All six patients with an exophthalmos reported reduced or lost visual acuity. These were due to an increase in pressure of the orbit. The symptom of a retro- / infraorbital hematoma with the formation of an exophthalmos as well as an accompanying change in visual acuity is an emergency indication for lateral canthotomy. Each of these patients was therefore treated with this procedure according to lege artis.
In six cases (9.5%), this corresponds to 0.4% in the entire group, the revision was due to a postoperative visual impairment or visual acuity loss. Permanent blindness was observed in one case. However, this was due to a direct trauma to the bulb and consecutively the visual nerve and not related to the performed surgery. This corresponds to a share of 0.06% in the entire patient collective. In the literature, the postoperative complication of blindness is not consistently stated; a complication rate of 0.04 to 8.3% is reported. [6264]
The data analysis showed that a revision, which was indicated due to an incorrect reconstruction, occurred significantly more frequently with increasing defect size (p = 0.003). In these cases, it could often be determined on the basis of the operation report that the reconstruction of the orbital floor or the insertion of the implant was problematic. Day et al. showed in 2018 that with the help of custom-made titanium mesh, a reduction in complication rates is possible, also with regard to position correction [65]. In the present study, too, an individual CAD/CAM technology-supported production of a titanium mesh was implanted in one patient. The defect was measured with a size of 260.83 mm2 and its extent was mainly posterior. However, due to the limitation of the results from one individual case, a general recommendation cannot be made.
Within our data analysis, a correlation between the preoperative and postoperative diplopia was observed. Orbital fractures can be regarded as one of several conditions in the development of a diplopia [55]. Therefore, the probability of double-image perception occurring increases with increasing defect size [48]. On the other hand, a significant correlation between the presence of preoperative symptoms of diplopia and the postoperative occurrence of double vision (p = 0.012) could be found. Ramphul and Hoffmann published a review in 2017 in which they examined the same relationship. As a result, they stated that no significance could be determined between the pre- and post-operative occurrences of diplopia. Due to the different etiologies of diplopia, in their opinion, different courses are possible. In this way, a diplopia can be completely eliminated, reduced, intensified or induced by the operation, whereby a statistical normal distribution is generated [66].
A remaining limitation of this study is the retrospective, mono centric design of the study, which may restrict the interpretation of the data. However, this disadvantage is compensated by the highest number of patients with orbital floor fractures evaluated in the literature so far.

Conclusion

Since the reconstruction of orbital wall fractures with polydioxanone sheets leads to significantly less post-operative complications (especially 0.15 mm polydioxanone sheets) even for defects beyond the recommended 200 mm2, they can be preferably recommended for orbital floor reconstruction. Reconstruction with the titanium mesh correlated with significantly more post-operative complications which limit its indication only to large and instable fractures that include multiple orbital walls. The present study could also show that a higher patient age does not necessarily correlate with more post-operative complications providing a strict indication for surgery. Moreover, we could confirm that an early surgery within the first seven days after trauma presents an ideal timeframe and that the trans-conjunctival incision led to significantly less post-operative complications compared to the infraorbital incision and should therefore be the preferred approach.

Declarations

Conflict of interest

All authors declare that they have no financial or non-financial competing interests that might create a conflict of interest with the information presented in this article.

Ethics approval

The study was approved by the ethical board of the University Hospital Frankfurt with the trial registration number 391/18 and carried out under the regulations of the Declaration of Helsinki. All participants of the study gave their written consent for participation, which they could withdraw at any time.
All participants of the study gave their written consent for participation, which they could withdraw at any time.
Patients signed informed consent regarding publishing their data and photographs.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Neuer Inhalt

Print-Titel

Literatur
2.
Zurück zum Zitat Zhou HH, Liu Q, Yang RT, Li Z, Li ZB. Ocular trauma in patients with maxillofacial fractures. J Craniofac Surg. 2014;25:519–23.PubMed Zhou HH, Liu Q, Yang RT, Li Z, Li ZB. Ocular trauma in patients with maxillofacial fractures. J Craniofac Surg. 2014;25:519–23.PubMed
3.
Zurück zum Zitat Frakes MA, Evans T. Evaluation and management of the patient with LeFort facial fractures. J Trauma Nurs. 2004;11:95–101.PubMed Frakes MA, Evans T. Evaluation and management of the patient with LeFort facial fractures. J Trauma Nurs. 2004;11:95–101.PubMed
4.
Zurück zum Zitat Zhang Y, Gu XM, Cai YJ, Duan DH. A revised scheme for LeFort classification of upper jaw fractures. Zhonghua Kou Qiang Yi Xue Za Zhi. 2005;40:134–6.PubMed Zhang Y, Gu XM, Cai YJ, Duan DH. A revised scheme for LeFort classification of upper jaw fractures. Zhonghua Kou Qiang Yi Xue Za Zhi. 2005;40:134–6.PubMed
5.
Zurück zum Zitat Cornelius C-P, Audigé L, Kunz C, Buitrago-Téllez C, Neff A, Rasse M, et al. Die neue AO-CMF-Traumaklassifikation für Erwachsene—Überblick, Präzisions-Level und anatomische Module für Unterkiefer, Kiefergelenkfortsätze. Mittelgesicht und Orbita OP-J. 2014;50:490–4. Cornelius C-P, Audigé L, Kunz C, Buitrago-Téllez C, Neff A, Rasse M, et al. Die neue AO-CMF-Traumaklassifikation für Erwachsene—Überblick, Präzisions-Level und anatomische Module für Unterkiefer, Kiefergelenkfortsätze. Mittelgesicht und Orbita OP-J. 2014;50:490–4.
6.
Zurück zum Zitat Shah HA, Shipchandler T, Vernon D, Baumanis M, Chan D, Nunery WR, et al. Extra-ocular movement restriction and diplopia following orbital fracture repair. Am J Otolaryngol. 2018;39:34–6.PubMed Shah HA, Shipchandler T, Vernon D, Baumanis M, Chan D, Nunery WR, et al. Extra-ocular movement restriction and diplopia following orbital fracture repair. Am J Otolaryngol. 2018;39:34–6.PubMed
7.
Zurück zum Zitat Fielding UNA. Blowout fractures—clinic, imaging and applied anatomy of the orbit. Dan Med J. 2018;65:B5459. Fielding UNA. Blowout fractures—clinic, imaging and applied anatomy of the orbit. Dan Med J. 2018;65:B5459.
8.
Zurück zum Zitat Sakavicius D, Juodzbalys G, Kubilius R, Sabalys GP. Investigation of infraorbital nerve injury following zygomaticomaxillary complex fractures. J Oral Rehabil. 2008;35:903–16.PubMed Sakavicius D, Juodzbalys G, Kubilius R, Sabalys GP. Investigation of infraorbital nerve injury following zygomaticomaxillary complex fractures. J Oral Rehabil. 2008;35:903–16.PubMed
9.
Zurück zum Zitat Gerbino G, Ramieri GA, Nasi A. Diagnosis and treatment of retrobulbar haematomas following blunt orbital trauma: a description of eight cases. Int J Oral Maxillofac Surg. 2005;34:127–31.PubMed Gerbino G, Ramieri GA, Nasi A. Diagnosis and treatment of retrobulbar haematomas following blunt orbital trauma: a description of eight cases. Int J Oral Maxillofac Surg. 2005;34:127–31.PubMed
10.
Zurück zum Zitat Hopper RA, Salemy S, Sze RW. Diagnosis of midface fractures with CT: what the surgeon needs to know. Radiographics. 2006;26:783–93.PubMed Hopper RA, Salemy S, Sze RW. Diagnosis of midface fractures with CT: what the surgeon needs to know. Radiographics. 2006;26:783–93.PubMed
11.
Zurück zum Zitat Burnstine MA. Clinical recommendations for repair of orbital facial fractures. Curr Opin Ophthalmol. 2003;14:236–40.PubMed Burnstine MA. Clinical recommendations for repair of orbital facial fractures. Curr Opin Ophthalmol. 2003;14:236–40.PubMed
12.
Zurück zum Zitat Saggese NP, Mohammadi E, Cardo VA. The ‘white-eyed’ orbital blowout fracture: an easily overlooked injury in maxillofacial trauma. Cureus. 2019;11:4412. Saggese NP, Mohammadi E, Cardo VA. The ‘white-eyed’ orbital blowout fracture: an easily overlooked injury in maxillofacial trauma. Cureus. 2019;11:4412.
13.
Zurück zum Zitat Cobb A, Murthy R, Manisali M, Uddin J, Toma A. Oculovagal reflex in paediatric orbital floor fractures mimicking head injury. Emerg Med J. 2009;26:351–3.PubMed Cobb A, Murthy R, Manisali M, Uddin J, Toma A. Oculovagal reflex in paediatric orbital floor fractures mimicking head injury. Emerg Med J. 2009;26:351–3.PubMed
14.
Zurück zum Zitat Iliff NT. The ophthalmic implications of the correction of late enophthalmos following severe midfacial trauma. Trans Am Ophthalmol Soc. 1991;89:477–548.PubMedPubMedCentral Iliff NT. The ophthalmic implications of the correction of late enophthalmos following severe midfacial trauma. Trans Am Ophthalmol Soc. 1991;89:477–548.PubMedPubMedCentral
15.
Zurück zum Zitat Pausch NC, Sirintawat N, Wagner R, Halama D, Dhanuthai K. Lower eyelid complications associated with transconjunctival versus subciliary approaches to orbital floor fractures. Oral Maxillofac Surg. 2016;20:51–5.PubMed Pausch NC, Sirintawat N, Wagner R, Halama D, Dhanuthai K. Lower eyelid complications associated with transconjunctival versus subciliary approaches to orbital floor fractures. Oral Maxillofac Surg. 2016;20:51–5.PubMed
16.
Zurück zum Zitat De Riu G, Meloni SM, Gobbi R, Soma D, Baj A, Tullio A. Subciliary versus swinging eyelid approach to the orbital floor. J Cranio-Maxillofacial Surg. 2008;36:439–42. De Riu G, Meloni SM, Gobbi R, Soma D, Baj A, Tullio A. Subciliary versus swinging eyelid approach to the orbital floor. J Cranio-Maxillofacial Surg. 2008;36:439–42.
17.
Zurück zum Zitat Bahr W, Bagambisa FB, Schlegel G, Schilli W. Comparison of transcutaneous incisions used for exposure of the infraorbital rim and orbital floor: a retrospective study. Plast Reconstr Surg. 1992;90:585–91.PubMed Bahr W, Bagambisa FB, Schlegel G, Schilli W. Comparison of transcutaneous incisions used for exposure of the infraorbital rim and orbital floor: a retrospective study. Plast Reconstr Surg. 1992;90:585–91.PubMed
18.
Zurück zum Zitat Kothari NA, Avashia YJ, Lemelman BT, Mir HS, Thaller SR. Incisions for orbital floor exploration. J Craniofac Surg. 2012;23:S43–7. Kothari NA, Avashia YJ, Lemelman BT, Mir HS, Thaller SR. Incisions for orbital floor exploration. J Craniofac Surg. 2012;23:S43–7.
19.
Zurück zum Zitat Gierloff M, Karl Seeck NG, Springer I, Becker S, Kandzia C, Wiltfang J. Orbital floor reconstruction with resorbable polydioxanone implants. J Craniofac Surg. 2012;23:161–4.PubMed Gierloff M, Karl Seeck NG, Springer I, Becker S, Kandzia C, Wiltfang J. Orbital floor reconstruction with resorbable polydioxanone implants. J Craniofac Surg. 2012;23:161–4.PubMed
20.
Zurück zum Zitat Pohlenz P, Adler W, Li L, Schmelzle R, Klatt J. Medial orbital wall reconstruction with flexible Ethisorb® patches. Clin Oral Investig. 2013;17:511–6.PubMed Pohlenz P, Adler W, Li L, Schmelzle R, Klatt J. Medial orbital wall reconstruction with flexible Ethisorb® patches. Clin Oral Investig. 2013;17:511–6.PubMed
21.
Zurück zum Zitat Pohlenz P, Adler W, Li L, Schmelzle R, Klatt J. Medial orbital wall reconstruction with flexible Ethisorb® patches. Clin Oral Investig. 2013;17:511–6.PubMed Pohlenz P, Adler W, Li L, Schmelzle R, Klatt J. Medial orbital wall reconstruction with flexible Ethisorb® patches. Clin Oral Investig. 2013;17:511–6.PubMed
22.
Zurück zum Zitat Banica B, Ene P, Vranceanu D, Ene R. Titanium preformed implants in orbital floor reconstruction—case presentation, review of literature. Maedica (Buchar). 2013;8:34–9. Banica B, Ene P, Vranceanu D, Ene R. Titanium preformed implants in orbital floor reconstruction—case presentation, review of literature. Maedica (Buchar). 2013;8:34–9.
23.
Zurück zum Zitat Metzger MC, Schön R, Schulze D, Carvalho C, Gutwald R, Schmelzeisen R. Individual preformed titanium meshes for orbital fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endodontol. 2006;35:990–5. Metzger MC, Schön R, Schulze D, Carvalho C, Gutwald R, Schmelzeisen R. Individual preformed titanium meshes for orbital fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endodontol. 2006;35:990–5.
24.
Zurück zum Zitat Ellis E, Tan Y. Assessment of internal orbital reconstructions for pure blowout fractures: cranial bone grafts versus titanium mesh. J Oral Maxillofac Surg. 2003;61:442–53.PubMed Ellis E, Tan Y. Assessment of internal orbital reconstructions for pure blowout fractures: cranial bone grafts versus titanium mesh. J Oral Maxillofac Surg. 2003;61:442–53.PubMed
25.
Zurück zum Zitat Kirby EJ, Turner JB, Davenport DL, Vasconez HC. Orbital floor fractures: outcomes of reconstruction. Ann Plast Surg. 2011;66:508–12.PubMed Kirby EJ, Turner JB, Davenport DL, Vasconez HC. Orbital floor fractures: outcomes of reconstruction. Ann Plast Surg. 2011;66:508–12.PubMed
26.
Zurück zum Zitat Rosado P, De Vicente JC. Retrospective analysis of 314 orbital fractures. Oral Surg Oral Med Oral Pathol Oral Radiol. 2012;113:168–71.PubMed Rosado P, De Vicente JC. Retrospective analysis of 314 orbital fractures. Oral Surg Oral Med Oral Pathol Oral Radiol. 2012;113:168–71.PubMed
27.
Zurück zum Zitat Ellis E, Messo E. Use of nonresorbable alloplastic implants for internal orbital reconstruction. J Oral Maxillofac Surg. 2004;62:873–81.PubMed Ellis E, Messo E. Use of nonresorbable alloplastic implants for internal orbital reconstruction. J Oral Maxillofac Surg. 2004;62:873–81.PubMed
28.
Zurück zum Zitat Kersey TL, Ng SGJ, Rosser P, Sloan B, Hart R. Orbital adherence with titanium mesh floor implants: a review of 10 cases. Orbit. 2013;32:8–11.PubMed Kersey TL, Ng SGJ, Rosser P, Sloan B, Hart R. Orbital adherence with titanium mesh floor implants: a review of 10 cases. Orbit. 2013;32:8–11.PubMed
29.
Zurück zum Zitat Hwang K, You SH. Analysis of facial bone fractures: an 11-year study of 2,094 patients. Indian J Plast Surg. 2010;43:42–8.PubMedPubMedCentral Hwang K, You SH. Analysis of facial bone fractures: an 11-year study of 2,094 patients. Indian J Plast Surg. 2010;43:42–8.PubMedPubMedCentral
30.
Zurück zum Zitat Baumann A, Burggasser G, Gauss N, Ewers R. Orbital floor reconstruction with an alloplastic resorbable polydioxanone sheet. Int J Oral Maxillofac Surg. 2002;31:367–73.PubMed Baumann A, Burggasser G, Gauss N, Ewers R. Orbital floor reconstruction with an alloplastic resorbable polydioxanone sheet. Int J Oral Maxillofac Surg. 2002;31:367–73.PubMed
31.
Zurück zum Zitat Gerressen M, Gilleßen S, Riediger D, Hölzle F, Modabber A, Ghassemi A. Radiologic and facial morphologic long-term results in treatment of orbital floor fracture with flexible absorbable alloplastic material. J Oral Maxillofac Surg. 2012;70:2375–85.PubMed Gerressen M, Gilleßen S, Riediger D, Hölzle F, Modabber A, Ghassemi A. Radiologic and facial morphologic long-term results in treatment of orbital floor fracture with flexible absorbable alloplastic material. J Oral Maxillofac Surg. 2012;70:2375–85.PubMed
33.
Zurück zum Zitat Cohen J. Quantitative methods in psychology: a power primer. Psychol Bull. 1992;112(1):155–9.PubMed Cohen J. Quantitative methods in psychology: a power primer. Psychol Bull. 1992;112(1):155–9.PubMed
34.
Zurück zum Zitat Peters TTA, Van Dijk BAC, Roodenburg JLN, Van Der Laan BFAM, Halmos GB. Relation between age, comorbidity, and complications in patients undergoing major surgery for head and neck cancer. Ann Surg Oncol. 2014;21:963–70.PubMed Peters TTA, Van Dijk BAC, Roodenburg JLN, Van Der Laan BFAM, Halmos GB. Relation between age, comorbidity, and complications in patients undergoing major surgery for head and neck cancer. Ann Surg Oncol. 2014;21:963–70.PubMed
35.
Zurück zum Zitat Ko HH, Chien WC, Lin YH, Chung CH, Cheng SJ. Examining the correlation between diabetes and odontogenic infection: a nationwide, retrospective, matched-cohort study in Taiwan. PLOS ONE. 2017;12:e0178941 (Public Library of Science).PubMedPubMedCentral Ko HH, Chien WC, Lin YH, Chung CH, Cheng SJ. Examining the correlation between diabetes and odontogenic infection: a nationwide, retrospective, matched-cohort study in Taiwan. PLOS ONE. 2017;12:e0178941 (Public Library of Science).PubMedPubMedCentral
36.
Zurück zum Zitat Guarracino F, Baldassarri R. The anesthetic management of transcatheter aortic valve implantation. Semin Cardiothorac Vasc Anesth. 2015;20:141–6.PubMed Guarracino F, Baldassarri R. The anesthetic management of transcatheter aortic valve implantation. Semin Cardiothorac Vasc Anesth. 2015;20:141–6.PubMed
37.
Zurück zum Zitat Vilela MC, Ferreira GZ, Santos PS, Rezende NP. Oral care and nosocomial pneumonia: a systematic review. Einstein (Sao Paulo). 2015;13(2):290–6. Vilela MC, Ferreira GZ, Santos PS, Rezende NP. Oral care and nosocomial pneumonia: a systematic review. Einstein (Sao Paulo). 2015;13(2):290–6.
38.
Zurück zum Zitat Shimada H, Suzukawa M, Ishizaki T, Kobayashi K, Kim H, Suzuki T. Relationship between subjective fall risk assessment and falls and fall-related fractures in frail elderly people. BMC Geriatr. 2011;11:40.PubMedPubMedCentral Shimada H, Suzukawa M, Ishizaki T, Kobayashi K, Kim H, Suzuki T. Relationship between subjective fall risk assessment and falls and fall-related fractures in frail elderly people. BMC Geriatr. 2011;11:40.PubMedPubMedCentral
39.
Zurück zum Zitat Jank S, Schuchter B, Emshoff R, Strobl H, Koehler J, Nicasi A, et al. Clinical signs of orbital wall fractures as a function of anatomic location. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2003;96:149–53.PubMed Jank S, Schuchter B, Emshoff R, Strobl H, Koehler J, Nicasi A, et al. Clinical signs of orbital wall fractures as a function of anatomic location. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2003;96:149–53.PubMed
40.
Zurück zum Zitat Burm JS. Internal fixation in trapdoor-type orbital blowout fracture. Plast Reconstr Surg. 2005;116:962–70.PubMed Burm JS. Internal fixation in trapdoor-type orbital blowout fracture. Plast Reconstr Surg. 2005;116:962–70.PubMed
41.
Zurück zum Zitat Yano H, Nakano M, Anraku K, Suzuki Y, Ishida H, Murakami R, et al. A consecutive case review of orbital blowout fractures and recommendations for comprehensive management. Plast Reconstr Surg. 2009;124:602–11.PubMed Yano H, Nakano M, Anraku K, Suzuki Y, Ishida H, Murakami R, et al. A consecutive case review of orbital blowout fractures and recommendations for comprehensive management. Plast Reconstr Surg. 2009;124:602–11.PubMed
42.
Zurück zum Zitat Cole P, Boyd V, Banerji S, Hollier LH. Comprehensive management of orbital fractures. Plast Reconstr Surg. 2007;120:57S-63S.PubMed Cole P, Boyd V, Banerji S, Hollier LH. Comprehensive management of orbital fractures. Plast Reconstr Surg. 2007;120:57S-63S.PubMed
43.
Zurück zum Zitat Burnstine MA. Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis. Ophthalmology. 2002;109:1207–10.PubMed Burnstine MA. Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis. Ophthalmology. 2002;109:1207–10.PubMed
45.
Zurück zum Zitat Petrigliano FA, Williams RJ. Orbital fractures in sport: a review. Sport Med. 2003;33:317–22. Petrigliano FA, Williams RJ. Orbital fractures in sport: a review. Sport Med. 2003;33:317–22.
46.
Zurück zum Zitat Boyette JR, Pemberton JD, Bonilla-Velez J. Management of orbital fractures: challenges and solutions. Clin Ophthalmol (Auckland, NZ). 2015;9:2127–37. Boyette JR, Pemberton JD, Bonilla-Velez J. Management of orbital fractures: challenges and solutions. Clin Ophthalmol (Auckland, NZ). 2015;9:2127–37.
47.
Zurück zum Zitat Poeschl PW, Baumann A, Dorner G, Russmueller G, Seemann R, Fabian F, et al. Functional outcome after surgical treatment of orbital floor fractures. Clin Oral Investig. 2012;16:1297–303.PubMed Poeschl PW, Baumann A, Dorner G, Russmueller G, Seemann R, Fabian F, et al. Functional outcome after surgical treatment of orbital floor fractures. Clin Oral Investig. 2012;16:1297–303.PubMed
48.
Zurück zum Zitat Converse JM, Smith B, Obear MF, Wood-Smith D, Converse JM. Orbital blowout fractures: a ten-year survey. Plast Reconstr Surg. 1967;39:20–36.PubMed Converse JM, Smith B, Obear MF, Wood-Smith D, Converse JM. Orbital blowout fractures: a ten-year survey. Plast Reconstr Surg. 1967;39:20–36.PubMed
49.
Zurück zum Zitat Hidding J, Deitmer T, Hemprich A, Ahrberg W. Primary correction of orbital fractures using PDS-foil. Fortschr Kiefer Gesichtschir. 1991;36:195–6.PubMed Hidding J, Deitmer T, Hemprich A, Ahrberg W. Primary correction of orbital fractures using PDS-foil. Fortschr Kiefer Gesichtschir. 1991;36:195–6.PubMed
50.
Zurück zum Zitat Rinna C, Ungari C, Saltarel A, Cassoni A, Reale G. Orbital floor restoration. J Craniofac Surg. 2005;16:968–72.PubMed Rinna C, Ungari C, Saltarel A, Cassoni A, Reale G. Orbital floor restoration. J Craniofac Surg. 2005;16:968–72.PubMed
51.
Zurück zum Zitat Raisian S, Fallahi HR, Khiabani KS, Heidarizadeh M, Azdoo S. Customized titanium mesh based on the 3D printed model vs. manual intraoperative bending of titanium mesh for reconstructing of orbital bone fracture: a randomized clinical trial. Rev Recent Clin Trials. 2017;12:154–8.PubMed Raisian S, Fallahi HR, Khiabani KS, Heidarizadeh M, Azdoo S. Customized titanium mesh based on the 3D printed model vs. manual intraoperative bending of titanium mesh for reconstructing of orbital bone fracture: a randomized clinical trial. Rev Recent Clin Trials. 2017;12:154–8.PubMed
52.
Zurück zum Zitat Thomas P, Bandl WD, Maier S, Summer B, Przybilla B. Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: case report and review of the literature. Contact Dermatitis. 2006;55:199–202.PubMed Thomas P, Bandl WD, Maier S, Summer B, Przybilla B. Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: case report and review of the literature. Contact Dermatitis. 2006;55:199–202.PubMed
53.
Zurück zum Zitat Ram H, Singh RK, Mohammad S, Gupta AK. Efficacy of iliac crest vs. medpor in orbital floor reconstruction. J Maxillofac Oral Surg. 2010;9:134–41.PubMedPubMedCentral Ram H, Singh RK, Mohammad S, Gupta AK. Efficacy of iliac crest vs. medpor in orbital floor reconstruction. J Maxillofac Oral Surg. 2010;9:134–41.PubMedPubMedCentral
54.
Zurück zum Zitat Bittermann G, Metzger MC, Schlager S, Lagrèze WA, Gross N, Cornelius C-P, et al. Orbital reconstruction: prefabricated implants, data transfer, and revision surgery. Facial Plast Surg Facial Plast Surg. 2014;30:554–60.PubMed Bittermann G, Metzger MC, Schlager S, Lagrèze WA, Gross N, Cornelius C-P, et al. Orbital reconstruction: prefabricated implants, data transfer, and revision surgery. Facial Plast Surg Facial Plast Surg. 2014;30:554–60.PubMed
55.
Zurück zum Zitat Kaufman Y, Stal D, Cole P, Hollier L. Orbitozygomatic fracture management. Plast Reconstr Surg. 2008;121:1370–4.PubMed Kaufman Y, Stal D, Cole P, Hollier L. Orbitozygomatic fracture management. Plast Reconstr Surg. 2008;121:1370–4.PubMed
56.
Zurück zum Zitat Chung J-H, You H-J, Hwang N-H, Kim D-W, Yoon E-S. Transconjuctival incision with lateral paracanthal extension for corrective osteotomy of malunioned zygoma. Arch Craniofacial Surg. 2016;17:119. Chung J-H, You H-J, Hwang N-H, Kim D-W, Yoon E-S. Transconjuctival incision with lateral paracanthal extension for corrective osteotomy of malunioned zygoma. Arch Craniofacial Surg. 2016;17:119.
57.
Zurück zum Zitat Appling WD, Patrinely JR, Salzer TA. Transconjunctival approach vs subciliary skin-muscle flap approach for orbital fracture repair. Arch Otolaryngol Neck Surg. 1993;9:1000. Appling WD, Patrinely JR, Salzer TA. Transconjunctival approach vs subciliary skin-muscle flap approach for orbital fracture repair. Arch Otolaryngol Neck Surg. 1993;9:1000.
58.
Zurück zum Zitat Ozturk S, Sengezer M, Isik S, Turegun M, Deveci M, Cil Y. Long-term outcomes of ultra-thin porous polyethylene implants used for reconstruction of orbital floor defects. J Craniofac Surg. 2005;16:973.PubMed Ozturk S, Sengezer M, Isik S, Turegun M, Deveci M, Cil Y. Long-term outcomes of ultra-thin porous polyethylene implants used for reconstruction of orbital floor defects. J Craniofac Surg. 2005;16:973.PubMed
59.
Zurück zum Zitat Gosau M, Schöneich M, Draenert FG, Ettl T, Driemel O, Reichert TE. Retrospective analysis of orbital floor fractures-complications, outcome, and review of literature. Clin Oral Investig. 2011;15:305–13.PubMed Gosau M, Schöneich M, Draenert FG, Ettl T, Driemel O, Reichert TE. Retrospective analysis of orbital floor fractures-complications, outcome, and review of literature. Clin Oral Investig. 2011;15:305–13.PubMed
60.
Zurück zum Zitat Dietz A, Ziegler CM, Dacho A, Althof F, Conradt C, Kolling G, et al. Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor. J Cranio-Maxillofacial Surg. 2001;29:82–8 (Churchill Livingstone). Dietz A, Ziegler CM, Dacho A, Althof F, Conradt C, Kolling G, et al. Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor. J Cranio-Maxillofacial Surg. 2001;29:82–8 (Churchill Livingstone).
61.
Zurück zum Zitat Brucoli M, Arcuri F, Cavenaghi R, Benech A. Analysis of complications after surgical repair of orbital fractures. J Craniofac Surg. 2011;22:1387–90.PubMed Brucoli M, Arcuri F, Cavenaghi R, Benech A. Analysis of complications after surgical repair of orbital fractures. J Craniofac Surg. 2011;22:1387–90.PubMed
62.
Zurück zum Zitat Breuer T, Grossenbacher R. Erblindung nach reposition einer jochbeinfraktur. HNO Springer. 2007;55:211–6. Breuer T, Grossenbacher R. Erblindung nach reposition einer jochbeinfraktur. HNO Springer. 2007;55:211–6.
63.
Zurück zum Zitat Girotto JA, Gamble WB, Robertson B, Redett R, Muehlberger T, Mayer M, et al. Blindness after reduction of facial fractures. Plast Reconstr Surg. 1998;102:1821–34 (Lippincott Williams and Wilkins).PubMed Girotto JA, Gamble WB, Robertson B, Redett R, Muehlberger T, Mayer M, et al. Blindness after reduction of facial fractures. Plast Reconstr Surg. 1998;102:1821–34 (Lippincott Williams and Wilkins).PubMed
64.
Zurück zum Zitat Lentrodt J, Unsöld R, Bosche J. Amaurosis following surgical management of orbital floor fractures–an unforeseeable complication? Fortschr Kiefer Gesichtschir. 1991;36:150–1.PubMed Lentrodt J, Unsöld R, Bosche J. Amaurosis following surgical management of orbital floor fractures–an unforeseeable complication? Fortschr Kiefer Gesichtschir. 1991;36:150–1.PubMed
65.
Zurück zum Zitat Day KM, Phillips PM, Sargent LA. Correction of a posttraumatic orbital deformity using three-dimensional modeling, virtual surgical planning with computer-assisted design, and three-dimensional printing of custom implants. Craniomaxillofac Trauma Reconstr. 2018;11:78–82 (SAGE Publications).PubMed Day KM, Phillips PM, Sargent LA. Correction of a posttraumatic orbital deformity using three-dimensional modeling, virtual surgical planning with computer-assisted design, and three-dimensional printing of custom implants. Craniomaxillofac Trauma Reconstr. 2018;11:78–82 (SAGE Publications).PubMed
66.
Zurück zum Zitat Ramphul A, Hoffman G. Does preoperative diplopia determine the incidence of postoperative diplopia after repair of orbital floor fracture? An institutional review. J Oral Maxillofac Surg. 2017;75:565–75 (W.B. Saunders).PubMed Ramphul A, Hoffman G. Does preoperative diplopia determine the incidence of postoperative diplopia after repair of orbital floor fracture? An institutional review. J Oral Maxillofac Surg. 2017;75:565–75 (W.B. Saunders).PubMed
Metadaten
Titel
Orbital floor fractures: epidemiology and outcomes of 1594 reconstructions
verfasst von
Lukas Benedikt Seifert
Tim Mainka
Carlos Herrera-Vizcaino
Rene Verboket
Robert Sader
Publikationsdatum
14.06.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 2/2022
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-021-01716-x

Weitere Artikel der Ausgabe 2/2022

European Journal of Trauma and Emergency Surgery 2/2022 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.