Abstract

Dual mobility cups (DMC) in total hip arthroplasty (THA) are becoming popular among orthopaedic surgeons. Substantial benefit of their use has been reported among high risk patients, particularly in reducing post-operative hip instability (dislocation). Many reports stated some concern when implanted in young and active people where complications such as polyethylene wear and mechanical loosening could potentially be higher. This Middle Eastern study analyses a retrospective series of THA for any aetiology other than infection, using DMC for the acetabular component in 75 patients (85 implants) less than 70 years old. No instability, intra-prosthetic dislocation or mechanical failure was reported during a mean follow-up of five years. The only major complication was a post-operative infection. The mean post- operative modified Harris hip score was 97.1 out of 100. All patients resumed their daily activities and all religious practicing patients were able to accomplish their prayer positions without pain. DMC is found to be an interesting option in reducing dislocation events in young patients. Those excellent short-term results would encourage surgeons to use DMC in an active and highly demanding population. Further research is necessary to confirm maintenance of such results at long term follow-up.
Literatur
1.
Zurück zum Zitat Bernd R, Doyle Y, Grundy E, McKee M (2009) How can health systems respond to population ageing? Heath Systems And Policy Analysis, WHO. ISSN 1997-8073 Bernd R, Doyle Y, Grundy E, McKee M (2009) How can health systems respond to population ageing? Heath Systems And Policy Analysis, WHO. ISSN 1997-8073
2.
Zurück zum Zitat Nho SJ, Kymes SM, Callaghan JJ, Felson DT (2013) The burden of hip osteoarthritis in the United States: epidemiologic and economic considerations. J Am Acad Orthop Surg 21(Suppl 1):S1–S6PubMed Nho SJ, Kymes SM, Callaghan JJ, Felson DT (2013) The burden of hip osteoarthritis in the United States: epidemiologic and economic considerations. J Am Acad Orthop Surg 21(Suppl 1):S1–S6PubMed
7.
Zurück zum Zitat De Martino I, Konstantinos G, Sculo P, Sculo T (2014) Dual mobility cups in total hip arthroplasty. World J Ortho 5(3):180–187CrossRef De Martino I, Konstantinos G, Sculo P, Sculo T (2014) Dual mobility cups in total hip arthroplasty. World J Ortho 5(3):180–187CrossRef
8.
Zurück zum Zitat Prudhon JL, Ferreira A, Verdier R (2013) Dual mobility cup: dislocation rate and survivorship at ten years of follow-up. IntOrthop 37(12):2345–2350 Prudhon JL, Ferreira A, Verdier R (2013) Dual mobility cup: dislocation rate and survivorship at ten years of follow-up. IntOrthop 37(12):2345–2350
9.
Zurück zum Zitat Leclercq S, Lemarechal P, Richter D, Aubriot JH (1999) Prothèses totales de hanche hybrides Charnley-Bousquet à plus de 10 ans. Rev Chir Orthop Reparatrice Appar Mot 85 :Suppl 3 Leclercq S, Lemarechal P, Richter D, Aubriot JH (1999) Prothèses totales de hanche hybrides Charnley-Bousquet à plus de 10 ans. Rev Chir Orthop Reparatrice Appar Mot 85 :Suppl 3
10.
Zurück zum Zitat Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R (2014) A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop 38(6):1125–9CrossRefPubMedPubMedCentral Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R (2014) A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop 38(6):1125–9CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Lachiewicz PF, Watters TS (2012) The use of dual-mobility components in total hip arthroplasty. J Am Acad Orthop Surg 20(8):481–486CrossRefPubMed Lachiewicz PF, Watters TS (2012) The use of dual-mobility components in total hip arthroplasty. J Am Acad Orthop Surg 20(8):481–486CrossRefPubMed
12.
Zurück zum Zitat Combes A, Migaud H, Girard J, Duhamel A, Fessy MH (2013) Low rate of dislocation of dual mobility cups in primary total hip arthroplasty. Clin Orthop Relat Res 471(12):3891–3900CrossRefPubMedPubMedCentral Combes A, Migaud H, Girard J, Duhamel A, Fessy MH (2013) Low rate of dislocation of dual mobility cups in primary total hip arthroplasty. Clin Orthop Relat Res 471(12):3891–3900CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Philippot R, Farizon F, Camilleri JP, Boyer B, Derhi G, Bonnan J, Fessy MH, Lecuire F (2008) Survival of cementless dual mobility socket with a mean 17 years follow-up. Rev Chir Orthop Reparatrice Appar Mot 94(8):e23CrossRefPubMed Philippot R, Farizon F, Camilleri JP, Boyer B, Derhi G, Bonnan J, Fessy MH, Lecuire F (2008) Survival of cementless dual mobility socket with a mean 17 years follow-up. Rev Chir Orthop Reparatrice Appar Mot 94(8):e23CrossRefPubMed
14.
Zurück zum Zitat Vielpeau C, Lebel B, Ardouin L, Burdin G, Lautridou C (2011) The dual mobility socket concept: experience with 668 cases. IntOrthop 35(2):225–230 Vielpeau C, Lebel B, Ardouin L, Burdin G, Lautridou C (2011) The dual mobility socket concept: experience with 668 cases. IntOrthop 35(2):225–230
15.
Zurück zum Zitat Epinette JA, Beracassat R, Tracol P, Pagazani P, Vandenbussche E (2014) Are modern dual mobility cups a valuable option in reducing instability after primary hip arthroplasty, even in younger patients? J Arthroplasty 29(6):1323–1328CrossRefPubMed Epinette JA, Beracassat R, Tracol P, Pagazani P, Vandenbussche E (2014) Are modern dual mobility cups a valuable option in reducing instability after primary hip arthroplasty, even in younger patients? J Arthroplasty 29(6):1323–1328CrossRefPubMed
16.
Zurück zum Zitat Fessy MH (2006) Dual mobility: A Stéphanois concept (St Etienne area, France). Maitrise Orthopedique March 152 Fessy MH (2006) Dual mobility: A Stéphanois concept (St Etienne area, France). Maitrise Orthopedique March 152
17.
Zurück zum Zitat Lautridou C, Lebel B, Burdin G, Vielpeau C (2008) Survival of the cementless Bousquet dual mobility cup: minimum 15-year follow-up of 437 total hip arthroplasties. Rev Chir Orthop Reparatrice Appar Mot 94:731–739CrossRefPubMed Lautridou C, Lebel B, Burdin G, Vielpeau C (2008) Survival of the cementless Bousquet dual mobility cup: minimum 15-year follow-up of 437 total hip arthroplasties. Rev Chir Orthop Reparatrice Appar Mot 94:731–739CrossRefPubMed
18.
Zurück zum Zitat Leclercq S, Benoit JY, de Rosa JP, Euvrard P, Leteurtre C, Girardin P (2008) Results of the Evora dual-mobility socket after a minimum follow-up of five years. Rev Chir Orthop Reparatrice Appar Mot 94(8):e17CrossRefPubMed Leclercq S, Benoit JY, de Rosa JP, Euvrard P, Leteurtre C, Girardin P (2008) Results of the Evora dual-mobility socket after a minimum follow-up of five years. Rev Chir Orthop Reparatrice Appar Mot 94(8):e17CrossRefPubMed
19.
Zurück zum Zitat Bouchet R, Mercier N, Saragaglia D (2011) Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res 97:2–7CrossRefPubMed Bouchet R, Mercier N, Saragaglia D (2011) Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res 97:2–7CrossRefPubMed
20.
Zurück zum Zitat Puch JM, Derhi G, Descamps L, Verdier R, Caton JH (2016) Dual-mobility cup in total hip arthroplasty in patients less than fifty five years and over ten years of follow-up: a prospective and comparative series. Int Orthop. doi:10.1007/s00264-016-3325-x Puch JM, Derhi G, Descamps L, Verdier R, Caton JH (2016) Dual-mobility cup in total hip arthroplasty in patients less than fifty five years and over ten years of follow-up: a prospective and comparative series. Int Orthop. doi:10.​1007/​s00264-016-3325-x
21.
Zurück zum Zitat Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A:9–14CrossRefPubMed Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A:9–14CrossRefPubMed
22.
Zurück zum Zitat Farizon F, de LAvison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. IntOrthop 22(4):219–224 Farizon F, de LAvison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. IntOrthop 22(4):219–224
23.
Zurück zum Zitat Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33(4):927CrossRefPubMed Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33(4):927CrossRefPubMed
24.
Zurück zum Zitat Boyer B, Philippot R, Geringer J, Farizon F (2012) Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. IntOrthop 36:511–518 Boyer B, Philippot R, Geringer J, Farizon F (2012) Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. IntOrthop 36:511–518
25.
Zurück zum Zitat Alberton GM, High WA, Morrey BF (2002) Dislocation after revision total hip arthroplasty: an analysis of risk factors and treatment options. J Bone Joint Surg Am 84-A:1788–1792CrossRefPubMed Alberton GM, High WA, Morrey BF (2002) Dislocation after revision total hip arthroplasty: an analysis of risk factors and treatment options. J Bone Joint Surg Am 84-A:1788–1792CrossRefPubMed
26.
Zurück zum Zitat Khatod M, Barber T, Paxton E, Namba R, Fithian D (2006) An analysis of the risk of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 447:19–23CrossRefPubMed Khatod M, Barber T, Paxton E, Namba R, Fithian D (2006) An analysis of the risk of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 447:19–23CrossRefPubMed
27.
Zurück zum Zitat Leiber-Wackenheim F, Brunschweiler B, Ehlinger M (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years’ follow-up. Orthop Traumatol Surg Res 97:8–13CrossRefPubMed Leiber-Wackenheim F, Brunschweiler B, Ehlinger M (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years’ follow-up. Orthop Traumatol Surg Res 97:8–13CrossRefPubMed
28.
Zurück zum Zitat Langlais FL, Ropars M, Gaucher F, Musset T, Chaix O (2008) Dual mobility cemented cups have low dislocation rates in THA revisions. Clin Orthop Relat Res 466(2):389–395CrossRefPubMedPubMedCentral Langlais FL, Ropars M, Gaucher F, Musset T, Chaix O (2008) Dual mobility cemented cups have low dislocation rates in THA revisions. Clin Orthop Relat Res 466(2):389–395CrossRefPubMedPubMedCentral
29.
Zurück zum Zitat Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J (2014) Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop 38(12):2463–8CrossRefPubMed Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J (2014) Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop 38(12):2463–8CrossRefPubMed
30.
Zurück zum Zitat Iorio R, Healy WL, Lemos DW, Appleby D, Lucchesi CA, Saleh KJ (2001) Displaced femoral neck fractures in the elderly: outcomes and cost effectiveness. Clin Orthop Relat Res 383:229–242CrossRef Iorio R, Healy WL, Lemos DW, Appleby D, Lucchesi CA, Saleh KJ (2001) Displaced femoral neck fractures in the elderly: outcomes and cost effectiveness. Clin Orthop Relat Res 383:229–242CrossRef
31.
Zurück zum Zitat Tarasevicius S, Busevicius M, Robertsson O, Wingstrand H (2010) Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture. BMC Musculoskelet Disord 11:175CrossRefPubMedPubMedCentral Tarasevicius S, Busevicius M, Robertsson O, Wingstrand H (2010) Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture. BMC Musculoskelet Disord 11:175CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Adam P, Philippe R, Ehlinger M, Roche O, Bonnomet F, Molé D, Fessy MH (2012) Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 98:296–300. doi:10.1016/j.otsr.2012.01.005 CrossRefPubMed Adam P, Philippe R, Ehlinger M, Roche O, Bonnomet F, Molé D, Fessy MH (2012) Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 98:296–300. doi:10.​1016/​j.​otsr.​2012.​01.​005 CrossRefPubMed
Metadaten
Titel
Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style
verfasst von
Chahine Assi
Elie El-Najjar
Camille Samaha
Kaissar Yammine
Publikationsdatum
10.01.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 3/2017
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3390-1

Weitere Artikel der Ausgabe 3/2017

International Orthopaedics 3/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.