Patient Identification Based on Deep Metric Learning for Preventing Human Errors in Follow-up X-Ray Examinations

verfasst von: Yasuyuki Ueda, Junji Morishita

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 5/2023

Abstract

Biological fingerprints extracted from clinical images can be used for patient identity verification to determine misfiled clinical images in picture archiving and communication systems. However, such methods have not been incorporated into clinical use, and their performance can degrade with variability in the clinical images. Deep learning can be used to improve the performance of these methods. A novel method is proposed to automatically identify individuals among examined patients using posteroanterior (PA) and anteroposterior (AP) chest X-ray images. The proposed method uses deep metric learning based on a deep convolutional neural network (DCNN) to overcome the extreme classification requirements for patient validation and identification. It was trained on the NIH chest X-ray dataset (ChestX-ray8) in three steps: preprocessing, DCNN feature extraction with an EfficientNetV2-S backbone, and classification with deep metric learning. The proposed method was evaluated using two public datasets and two clinical chest X-ray image datasets containing data from patients undergoing screening and hospital care. A 1280-dimensional feature extractor pretrained for 300 epochs performed the best with an area under the receiver operating characteristic curve of 0.9894, an equal error rate of 0.0269, and a top-1 accuracy of 0.839 on the PadChest dataset containing both PA and AP view positions. The findings of this study provide considerable insights into the development of automated patient identification to reduce the possibility of medical malpractice due to human errors.
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Patient misidentification due to human error remains a major concern in the healthcare industry [18]. According to a previous study [3], the average rate of misfiled cases for radiography at a hospital is 0.075%.
A previous paper [5] reported that “a 2006 study [6] reviewing several adverse events databases in the United States estimated that between 1,300 and 2,700 adverse events relating to wrong side or site, wrong procedure, and wrong patient occurred annually. It identified radiology as the second most common hospital department (after the operating room) to perform wrong-site procedures.” Although the primary risk of patient misidentification in clinical X-ray examinations is radiation exposure of the wrong patient, it can lead to serious incidents or accidents, such as operating of the wrong patient [6].
Risk management in clinics and hospitals employs a standard process for patient verification because confirming patient-specific information (such as the full name and date of birth) is critical [9]. Although using two patient identifiers can improve the reliability of patient identification, such a process is not the most effective for preventing human errors, resulting in misfiling and misidentification [10, 11]. To minimize the risk of human error and improve healthcare workflow and utility, clinics and hospitals may use biometrics, such as fingerprints and face recognition, for routine examinations. However, the use of these methods can increase the workload of healthcare providers.
Digital transformation in healthcare can be realized using various technologies to streamline operations for healthcare providers and ensure patient safety. Several types of clinical images, such as chest X-ray or scout images, exhibit considerable potential for use in biometric patient verification [13, 1227] and forensic personal identification [2835]. The potential risk of patient registration errors owing to multiple factors, including human errors, can be reduced by consolidating clinical information and using it for patient identity verification. Furthermore, such a technology has the potential to identify the personal information of a patient without the patient verbally stating their name or date of birth. Several biometric methods based on clinical images have been proposed to achieve satisfactory patient verification and identification [13, 1224].
Deep learning-based technologies have been applied to several tasks using clinical X-ray images [3639] of the chest [12, 28, 36, 4046], including lesion detection and estimation of individual attributes, such as gender and age. Some issues need to be addressed for deep learning-based biometric systems to be utilized in clinics or hospitals. In hospitals and clinics, a biometric system can identify a large number of patients during the second examination without retraining the system for each new patient. Several methods have been reported for the classification of chest X-ray images used in clinics or hospitals [12]; however, such methods are yet to be used in actual clinical applications.
The performance of such biometric techniques applied to clinics and hospitals can degrade owing to variabilities in the clinical chest X-ray images, including variations in posteroanterior (PA) and anteroposterior (AP) view positions, image processing, and patient conditions (pre- and post-operative or trauma) [13, 14]. In particular, regarding view positions, healthy subjects are examined in the standing and PA view positions in routine chest X-ray imaging. However, depending on the patient’s condition (such as inability to stand or postmortem), the examination is performed in the spine or in the sitting AP view position. Previous studies have revealed that classification between PA and AP view positions is possible in chest X-ray images [36]; this also implies that there is a domain-shift problem between PA and AP view positions. Therefore, differences in the positions of PA and AP views, including differences in the patient’s condition and imaging geometry, can have a significant impact on their biometric performance. Although some studies have addressed this problem [28], the domain-shift problem caused by differences in view position has not been resolved, and concerns regarding its clinical application are yet to be addressed. Biometric systems for clinics and hospitals are expected to not only have adequate biometric performance based on clinical images [4749] but also exhibit robustness under clinical image variabilities; therefore, such a biometric system, which exhibits good performance under varied view positions, will potentially be effective for use in clinics and hospitals.
The objective of the study was to (a) develop a deep learning-based feature extractor and classifier using the similarity index to perform patient identity verification during chest X-ray examination and (b) quantitatively evaluate the outcomes of the proposed method on clinical chest X-ray datasets with clinical variabilities, such as different view positions.

Materials and Methods

Outline of the Proposed Method

The proposed deep learning metric-based patient verification and identification system is illustrated in Fig. 1. The system comprises three units: (i) image acquisition and preprocessing, (ii) feature extraction, and (iii) identification. The first unit acquires an image with a routine chest X-ray examination and performs image postprocessing. Healthcare providers are not required to perform any additional work in biometric patient verification. In the second unit, the feature extractor trained by the proposed model extracts the features that identify an individual from chest X-ray images. In the final unit, the similarity index of the extracted features between clinical chest X-ray images and stored clinical datasets is used to determine whether the patients are the same.
The proposed method was evaluated using four test datasets different from the dataset used for training and validation. Two datasets were public datasets, whereas the other two were clinical chest X-ray image datasets.

Datasets

The experiment was a retrospective, observational study and was approved by the Institutional Review Boards at Osaka University (Approval Number: 19422–6). Therefore, informed consent was not mandatory. All procedures performed in this study conformed to the guidelines and ethics set by the Helsinki Declaration.
Table 1 summarizes the patient demographics in the five datasets used for training, validating, and testing the DCNN used in the proposed method. The ChestX-Ray8 dataset [50], used for training and validation, included 57,452 chest X-ray images from 3,245 patients with at least eight chest X-ray images per patient that were examined on both PA and AP view positions. All 57,452 chest X-ray images were used in either training or validating subsets, but not both. Of the 57,452 chest X-ray images of 3,245 patients, 50,962 images were used for training and 6,490 images for validating the trained model. To enable mini-batch learning within the computation limitations for training and validation, the image pixel spacing of all the images was resampled to 1.0 × 1.0 mm2 (276 to 495 and 261 to 495 pixels for rows and columns, respectively) using bicubic interpolation and by cropping the central 320 × 320 pixels.
Table 1
Datasets used for DCNN training, validation, and testing
Public dataset
ChestXray8
CheXpert
PadChest
 
Number of patients
3,245
10,224
6,376
Patients
Number of images
57,452
32,972
19,713
Images
Gender
   
Patients
Male
1,892
5,272
3,594
 
Female
1,353
4,952
2,780
 
Others
0
0
2
 
View position
   
Images
PA
26,018
6
7,867
 
AP
31,434
32,966
11,846
 
Age categories
   
Patients
Neonate, infant (0 years)
0
 
152
 
Young child (1–4 years)
0
 
222
 
Older child (5–10 years)
0
 
85
 
Adolescent (11–19 years)
0
 
62
 
Adult (20 years or more)
3,245
 
5,855
 
Examination interval categories (from baseline to follow-up X-ray examination dates)
Image–pairs
Under 1 year
  
10,559
 
From 1 to 5 years
  
2,241
 
Over 5 years
  
537
 
Clinical dataset
ML
YU
 
Number of images
81,109
25,547
images
Number of patients
31,366
12,517
patients
Examined baseline X-rays
12,790
8,417
 
Examined baseline and follow-up X-rays
18,576
4,100
 
Age (at the baseline examination)
  
years
Mean ± SD
55 ± 15
64 ± 16
 
Range
15–95
20–100
 
Gender
  
patients
Male
13,845
6,653
 
Female
17,521
5,864
 
View position
  
images
PA
81,109
23,953
 
AP
0
1,594
 
Subsets of clinical dataset (with at least two examinations per patient)
Number of images
68,319
17,130
images
Number of patients
18,576
4,100
patients
Pair of view positions (baseline and follow-up)
pairs
PA–PA
49,743
11,487
 
AP–PA
0
613
 
PA–AP
0
306
 
AP–AP
0
624
 
Examination intervals between the baseline and follow-up X-ray examination dates
days
Mean ± SD
1,051 ± 635
100 ± 115
 
Range
0–2,932
0–489
 
ML Morishita Laboratory, YU Yamaguchi University, PA Posteroanterior, AP Anteroposterior, SD Standard Deviation, PA–PA subset for PA view at both examinations, AP–PA subset for AP view at baseline and PA view at follow–up examinations, PA–AP subset for PA view at baseline and AP view at follow–up examinations, AP–AP subset for AP view for both examinations
Two public datasets and two clinical datasets were used for testing. The first public dataset, PadChest [51], included 19,713 chest X-ray images from 6376 patients with at least two PA or AP chest X-ray images per patient. The image pixel spacing of all images was resampled to 1.0 × 1.0 mm2 (151 to 431 and 158 to 431 pixels for rows and columns, respectively) using bicubic interpolation. Furthermore, the bit depth was rescaled linearly down to 8 bits. The second public dataset, CheXpert [52], included 32,972 chest X-ray images from 10,224 patients. We used the CheXpert-V1.0-Small dataset in which the image pixel size and bit depth of all images were 512 × 512 pixels and 8 bits, respectively.
The first clinical dataset named “Morishita Laboratory (ML)” comprised 81,109 chest X-ray images from 31,366 patients who underwent chest X-ray screening examinations between March 1986 and October 2004 in Iwate, Japan. Images of patients in the ML dataset were acquired using a computed radiography system (Fujifilm, Tokyo, Japan) under a matrix size of 1760 × 1760 pixels, pixel spacing of 0.2 × 0.2 mm2, and 10-bit greyscale. The second clinical dataset named “Yamaguchi University (YU)” comprised 25,547 chest X-ray images from 12,517 patients obtained by random sampling from patients aged 20 years or older who underwent routine chest X-ray examinations between October 2015 and March 2017 at Yamaguchi University Hospital, Japan. All the images in the YU dataset were acquired using a flat-panel detector system (AeroDR; Konica Minolta Inc., Tokyo, Japan) or a computed radiography system (REGIUS MODEL 110; Konica Minolta Inc., Tokyo, Japan) with a matrix size of 2430 × 1994 pixels, pixel spacing of 0.175 × 0.175 mm2, and 12-bit greyscale. The data were processed using the diagnostic imaging workstation (model CS-7 version 1.20–1.30; Konica Minolta Inc., Tokyo, Japan). In addition to the public dataset, we resampled all the images in the two clinical datasets to images with a pixel spacing of 1.0 × 1.0 mm2 using bicubic interpolation. Furthermore, the bit depth was rescaled linearly down to 8 bits.

DCNN Learning

Outline of DCNN Learning by the Proposed Model

The EfficientNetV2-S backbone network with metric learning was used to train the DCNN for classifying individual examined patients based on chest X-ray images. Deep learning was performed using a computer with a GeForce 3090 Ti (NVIDIA, Santa Clara, Calif) graphics processing unit, Core i9-10900X 3.70 GHz (Intel, Corp., Santa Clara, Calif) central processing unit, and 128 GB of random-access memory.
Python 3.10.8 and PyTorch 1.13.0 + cu117 were used to perform DCNN training, validation, and testing using the element-wise adaptive sharpness-aware minimization optimizer [53] (base optimizer, SGD with a momentum of 0.8, and a weight decay of 0.0005) with a neighborhood size, rho, of 2.0, batch size of 60, smooth cross-entropy loss function with a label smoothing of 0.1, and cosine-decay learning rate scheduler (initial–last: 0.02–0.0004) without warmup. During each training epoch, each image was augmented to correspond to the variabilities in clinical chest X-ray images as follows: random rotation between − 10° and 10° and random perspective transformation with a probability of 0.1 and distortion scale of 0.25 with bicubic resampling. The training time of the proposed method was approximately 70 h for 300 epochs of learning.

Feature Extractor Used by the Proposed Model

The EfficientNetV2-S backbone network with metric learning was used to train the DCNN for classifying individual examined patients based on chest X-ray images. EfficientNet uses mobile inverted bottleneck convolution (MBConv), similar to MobileNetV2 [54] and MnasNet [55]. A compound scaling method that uniformly scales each dimension with a fixed set of scaling coefficients is incorporated in the system [56]. In EfficientNetV2, fused-MBConv layers replace the 3 × 3 depth-wise convolution (conv3 × 3), and the 1 × 1 boosted convolution (conv1 × 1) is expanded in MBConv in the original EfficientNet with a normal 3 × 3 convolution to improve training performance [57]. The output values of the feature extractor trained using the proposed method were used as features to characterize individuals.

Classifier Used by the Proposed Model

Conventional image classifiers cannot achieve high generalizability even with deep learning and require numerous training samples of medical images and a long training time, which degrades the performance of the DCNN. By contrast, deep metric learning is a technique for improving the accuracy of classifiers [58]. Deep metric learning can be used to develop a feature extractor with high generalizability using fewer classes and images [58].
Figure 2 displays the classifier used by the proposed method that converts the features in the feature extractor output into the prediction of the 3245 classes of patients for the training subset. The classifier network comprises a nonlinear fully connected (FC) layer with metric learning layer (Fig. 2). The nonlinear FC layers comprise the following sequential layers: a linear layer, dropout layer, rectified linear unit (ReLU) activation function, and linear layer. Linear function applies a linear transformation to input matrices. ReLU is an activation function that renders the network nonlinear and fits complex data. Dropout is a regularization method for reducing overfitting in neural networks during training. Furthermore, we introduced AdaCos [59], which is a deep metric learning technique, to control dimensionality reduction complexity while preserving the individual characteristics of each patient. AdaCos [59] can automatically determine hyperparameters and successfully perform deep metric learning without additional tuning steps.

Similarity Index by the Proposed Model

The cosine similarity between the features in the follow-up and baseline chest X-ray images was used as the similarity index. The cosine similarity ranged from − 1 to 1 and was used for distinguishing same or distinct matched patient pairs. Values closer to 1 present the same patient pair. The cosine similarity is considered superior to the distance measurement in face verification [60].

Hyperparameter Evaluation of the Proposed Model

Several hyperparameter settings of the proposed method were evaluated in terms of each top-1 accuracy on the PadChest dataset divided into the following four subsets in terms of view position combinations at the baseline and each follow-up examination: PA view at both examinations (PA–PA), AP view at the baseline and PA view at follow-up examinations (AP–PA), PA view at the baseline and AP view at follow-up examinations (PA–AP), and AP view for both examinations (AP–AP).
In this study, we evaluated the following hyperparameters: number of epochs and number of features in the feature extractor output. The number of features was varied by further applying a linear transformation to the output from the feature extractor.

Verification Performance Evaluation of the Proposed Method

The image with the oldest examination date in the PadChest, YU, and ML datasets was used as the baseline image, and the other images were used as follow-up images. To evaluate the verification performance, this study used all image pairs from the same patient and the image pairs from different patients by random sampling: PadChest (6376 and 6376 of respective same and different patient pairs), YU (4100 and 4100 of respective same and different patient pairs), and ML (18,576 and 18,576 of respective same and different patient pairs) datasets. For the CheXpert dataset, we used the image-pair list, of which 8243 were of same patient pairs and 8243 of different patient pairs, used in a previous study [12].
The verification performance of the proposed method was evaluated in terms of the area under the receiver operating characteristic (ROC) curve (AUC) and equal error rate (EER). The ROC curves were statistically compared using the unpaired DeLong’s test [61].

Closed-Set Identification Performance Evaluation of the Proposed Method

The image with the oldest examination date in the PadChest, YU, and ML datasets was used as the baseline image, and the other images were used as the follow-up image by employing all combinations for closed-set identification performance evaluation: PadChest (baseline 6,376 images of 6376 patients and follow-up 13,337 images of 6376 patients), YU (baseline 12,517 images of 12,517 patients and follow-up 13,030 images of 4100 patients), and ML (baseline 31,366 images of 31,366 patients and follow-up 49,743 images of 18,576 patients) datasets.
The closed-set identification performance of the proposed method was evaluated in terms of top-1 and top-2 accuracies. Top-2 accuracy refers to the accuracy when any of the pairs within the top-two higher cosine similarities in all patient comparisons are the same patient pairs. The top-1 accuracy on each subset by view position combinations was compared statistically using the two proportion Z-test.

Results

Figure 3 shows the top-1 accuracy transition of the hyperparameter variabilities on the PadChest dataset and four subsets, which are PA–PA, PA–AP, AP–PA, and AP–AP, using the proposed method. As can be observed in Fig. 3a, the performance of the proposed method improved with the increase in the number of epochs to 300. As shown in Fig. 3b, the top-1 accuracy transition remains flat regardless of the number of features.
Figure 4 shows the top-1 accuracy transition of (a) patient age in the baseline examination and (b) examination interval between the variabilities in the baseline and follow-up categories on the PadChest dataset using the proposed method with the result of the two proportion Z-test. In Fig. 4a, it can be observed that the top-1 accuracy increased until the age category reached adolescent. The top-1 accuracy of the adult category was significantly lower than that of adolescent (p < 0.05). Furthermore, in Fig. 4b, it is seen that the top-1 accuracy with an examination interval of less than one year was not significantly different from those with examination intervals from one to five years and greater than five years.
Table 2 summarizes the verification performance of the proposed method in terms of AUC and EER values on two public and two clinical datasets with 300 epochs and 1,280 features. Significant differences were observed between each different dataset (p < 0.01). The AUC values of the proposed method on the CheXpert (AUC = 0.9943) and ML datasets (AUC = 0.9999) were superior to those of the methods proposed by Packhäuser et al. on the CheXpert dataset (AUC = 0.9870) [12], Morishita et al. on the ML dataset (AUC = 0.993) [16], and Shimizu et al. on the ML dataset (AUC = 0.994) [17].
Table 2
Verification performance of the proposed method on two public and two clinical datasets
Dataset
EER
AUC
p value
vs. CheXpert
vs. ML
vs. YU
PadChest
2.70 × 10−2
0.9899
2.02 × 10−7
2.20 × 10−16
2.20 × 10−16
CheXpert
2.96 × 10−2
0.9943
2.20 × 10−16
2.98 × 10−6
ML
5.65 × 10−4
0.9999
9.10 × 10−4
YU
5.12 × 10−3
0.9980
p value calculated for AUC values by the unpaired DeLong test. ML Morishita Laboratory, YU Yamaguchi University, EER Equal Error Rate, AUC Area under the receiver operating characteristic curve
Table 3 summarizes the closed-set identification performance of the proposed method in terms of top-1 and top-2 accuracies on a public and two clinical datasets with 300 epochs and 1280 features. The closed-set identification performance of follow-up examinations with different view positions (PA–AP or AP–PA) was significantly lower than that with a same view position (PA–PA or AP–AP). Furthermore, although the top-2 accuracy increased to 0.984, the top-1 accuracy showed a sharp decrease to 0.749 on the YU dataset.
Table 3
Identification performance of the proposed method on a public and two clinical datasets
Dataset
Subset
Number of patients
Top-1 accuracy
p value
Top-2 accuracy
PadChest
PA–PA
3,584
0.910
1.42 × 10–68
 
PA–AP
1,412
0.717
 
AP–AP
7,184
0.818
1.01 × 10–16
 
AP–PA
1,157
0.713
 
All view positions
13,337
0.823
 
0.875
ML
PA–PA
49,743
0.993
 
0.999
YU
PA–PA
11,487
0.738
0.742
 
PA–AP
613
0.731
 
AP–AP
624
0.923
1.23 × 10–9
 
AP–PA
306
0.781
 
All view positions
13,030
0.747
 
0.981
p value calculated for top-1 accuracy by the two proportion Z-test. ML Morishita Laboratory, YU Yamaguchi University, PA–PA subset for PA view at both examinations, AP–PA subset for AP view at baseline and PA view at follow-up examinations, PA–AP subset for PA view at baseline and AP view at follow-up examinations, AP–AP subset for AP view for both examinations
Figure 5 shows an important area visualization that identifies the patient using the model trained based on the proposed method by Grad-CAM [62]. Grad-CAM generates heat maps of characteristic features and superimposes them on the original X-ray image to visualize the important regions that affect patient verification.

Discussion

In this study, a DCNN feature extractor and classifier based on the similarity index was used to verify the identity of examined patients using clinical chest X-ray images. The proposed method is available for use not only from the second examination onwards without additional training but also extracts robust features regarding different view positions. The number of features output by the EfficientNetV2-S backbone is used as a hyperparameter in the proposed method. We set the number of features to 1280 and the number of epochs to 300. The results revealed that this evaluation method achieved high performance not only on public datasets containing a large amount data and different view positions but also on clinical datasets that include clinical image variabilities (Tables 23). Packhäuser et al. [12] achieved an AUC value of 0.9870 on the CheXpert dataset. Furthermore, Morishita et al. [16] and Shimizu et al. [17] achieved the highest AUC values of 0.993 and 0.994, respectively, on the ML dataset. In comparison, the proposed method achieved AUC values of 0.9999 and 0.9943 on the ML and CheXpert datasets, respectively, which are both higher than those achieved by the previous methods [12, 16, 17].
In the comparison (PA–AP and AP–PA subsets in the PadChest dataset) between the combinations of different view positions shown in Fig. 3a, the top-1 accuracy improved when the number of epochs was increased to 300. The results in the PA–PA and AP–AP comparisons, that is, combinations of the same view position, were sufficiently accurate even with 200 epochs, and increasing the number of epochs did not improve the accuracy. Therefore, the optimal number of epochs depends on the type of view positions present in the dataset. These results suggest that underfitting may occur in feature extraction at different view positions up to 300 epochs. More than 300 epochs are required to extract robust features for different view positions. We assume that, depending on the model, when the number of epochs exceeds 300 during training, techniques such as regularization and data augmentation are needed to suppress overfitting in the proposed method.
An increase in the interval between two examinations negligibly affected the top-1 accuracy of the proposed method, as shown in Fig. 4b; therefore, the examination intervals are expected to not be problematic for clinical applications of this method.
Areas around the devices implanted in the three patient examples shown in Fig. 5 are hardly recognized as important areas for feature extraction. Although we are concerned that the devices might be recognized as characteristic features, we believe that the proposed method has the potential to be applied to patient verification and identification from chest X-ray images even if high-contrast objects, such as accessories (removable) or metal implants (not removable), are present in the imaging area. Furthermore, changes in lung condition due to pneumonia or slightly oblique patient positions do not affect the performance of the proposed method in extracting patient-characteristic features.
This study has certain limitations. First, the results suggest that patient identification using chest X-ray images has a domain-shift problem in different view positions, including the reproducibility of the positioning. The performance of the proposed method on the ML dataset was consistently superior to that on the YU, PadChest, and CheXpert datasets in terms of AUC, EER, and top-1 and top-2 accuracies, likely because all patients in the ML dataset underwent the chest X-ray imaging in a standing or sitting PA view position. In terms of the reproducibility of positioning, the ML dataset, which does not include the AP view position, is comprehensively superior to the YU, PadChest, and CheXpert datasets. Furthermore, results revealed a degradation in the top-1 accuracy performance between different view positions (AP–PA or PA–AP) compared with images from the same view position (PA–PA or AP–AP). We demonstrated that one of the solutions to this problem is to increase the number of epochs and suppress underfitting. Although the performance on the YU, PadChest, and CheXpert datasets was not as effective as that on the ML dataset, the metrics showed reasonably good results. However, there is a statistically significant difference between the top-1 accuracies for the same and different view positions. We expect further accuracy improvements using applications such as domain adaptation techniques [12, 28].
Second, in Fig. 4a, significant differences can be observed in the performance of the proposed method in terms of the top-1 accuracies for each patient age category. The top-1 accuracies were significantly lower for the neonate-infant, young child, and older child categories compared with the adult category. We concluded that the performance degradation was because the model underfitted to the changes in the patient’s body over the growth period, which could be attributed to no images of patients aged under 20 in the training dataset. Further research is required on efficient learning with small datasets.
Third, although the top-2 accuracy increased to 0.984, the top-1 accuracy showed a sharp decrease to 0.749 on the YU dataset. At the hospital that provided the YU dataset, a new patient identifier (ID) is issued when a patient visits for the first time; however, in some cases, an already registered patient with a patient ID was assigned a new patient ID. In this case, two patient IDs were assigned to the same patient. In this study, the patient ID registered in the DICOM header was treated as one patient with one ID. Therefore, if the patient ID recorded in the DICOM header is different, it will be regarded as the image of a different patient, even if it is the same patient. However, if the similarity is high because it is the same patient, the top-1 accuracy still degrades. Furthermore, the YU dataset contains some inadequate X-ray images resulting from errors that occur while reading and transferring the images. However, the patient ID is correctly recorded in the header of these images. Although it is the same patient on the ID recorded in the DICOM images, the results show that the similarity index is low between inadequate and other adequate images. A record that has been assigned two IDs is managed in the hospital information system (HIS) or radiology information system (RIS). It is, therefore, desirable to use the patient IDs recorded in HIS/RIS information, not the patient IDs recorded in DICOM images, for lists used in biometric systems in clinical applications. Moreover, we believe that measures to disable inadequate images presented above are desirable.
In addition, in this study, each clinical dataset was obtained using X-ray imaging devices with the same model and similar acquisition parameters. Different X-ray imaging devices have different image contrast in chest X-ray images; therefore, the performance achieved in this study may not be reproducible. To evaluate the biometric performance on a variety of image contrasts, a dataset consisting of clinical X-ray images from several clinics or hospitals using common patient identifier is required.
The proposed method can confirm that the patient who underwent chest X-ray examination and the patient to be examined are the same. Moreover, the proposed method is available for checking the misfiling patient identifier on the picture archiving and communication system. We thereby expect that the proposed method will be useful for safety systems that could prevent these patient misidentification problems and will be able to contribute to the reduction of the risk of incorrectly identifying patient due to human error.

Conclusions

Potential risks that can lead to medical malpractice, such as patient misidentification in clinical examinations and misfiling of images stored in picture archiving and communication systems, are still inherent in clinical work. In this study, a patient verification and identification method was proposed using a deep feature extractor with robustness under different view positions from images obtained by clinical chest X-ray examination. The performance of the proposed method was verified not only on two public datasets but also on two clinical image datasets, namely ML and YU. Clinical chest X-ray examinations that utilize cutting-edge technology (such as the technique presented in this study) provide a key solution to prevent patient misidentification resulting from human errors.

Acknowledgements

The authors thank Dr. Shohei Kudomi at Yamaguchi University Hospital, Japan, for his valuable insights on improving our manuscript; Drs. Masatoshi Yamane and Takuya Uehara at Yamaguchi University Hospital, Japan, for organizing the Yamaguchi University Dataset; Drs. Yongsu Yoon at Dongseo University, Republic of Korea, and Yoichiro Shimizu at Yamaguchi University Hospital, Japan, for organizing the Morishita Lab. Dataset; and Editage (http://​www.​editage.​com) for providing English language editing.

Declarations

Ethics Approval

All procedures in this study were in conformance with the ethical standards of the Institutional Review Board at each authors’ affiliated institutions and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
Written informed consent was not required for this study because of the retrospective nature of the study.
Written consent of the study participants or their legal guardians was not required for publishing the data of the individuals in the manuscript because of the retrospective nature of this study.

Competing Interests

The authors declare no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Radiologie

Kombi-Abonnement

Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.

Literatur
2.
Zurück zum Zitat Morishita J, Katsuragawa S, Kondo K, Doi K: An automated patient recognition method based on an image-matching technique using previous chest radiographs in the picture archiving and communication system environment. Med Phys 28(6):1093–1097, 2001. https://doi.org/10.1118/1.1373403 Morishita J, Katsuragawa S, Kondo K, Doi K: An automated patient recognition method based on an image-matching technique using previous chest radiographs in the picture archiving and communication system environment. Med Phys 28(6):1093–1097, 2001. https://​doi.​org/​10.​1118/​1.​1373403
25.
Zurück zum Zitat Koike-Akino T, Mahajan R, Marks TK, et al.: High-accuracy user identification using EEG biometrics. Conf Proc IEEE Eng Med Biol Soc 2016: 854-858, 2016. Koike-Akino T, Mahajan R, Marks TK, et al.: High-accuracy user identification using EEG biometrics. Conf Proc IEEE Eng Med Biol Soc 2016: 854-858, 2016.
26.
27.
Zurück zum Zitat Sakai Y, Takahashi K, Shimizu Y, Ishibashi E, Kato T, Morishita J: Clinical application of biological fingerprints extracted from averaged chest radiographs and template-matching technique for preventing left-right flipping mistakes in chest radiography. Radiol Phys Technol 12:216-223, 2019. https://doi.org/10.1007/s12194-019-00504-y Sakai Y, Takahashi K, Shimizu Y, Ishibashi E, Kato T, Morishita J: Clinical application of biological fingerprints extracted from averaged chest radiographs and template-matching technique for preventing left-right flipping mistakes in chest radiography. Radiol Phys Technol 12:216-223, 2019. https://​doi.​org/​10.​1007/​s12194-019-00504-y
28.
Zurück zum Zitat Nguyen K, Nguyen HH, Tiulpin A: AdaTriplet: Adaptive gradient triplet loss with automatic margin learning for forensic medical image matching. In: Wang L, Dou Q, Fletcher PT, Speidel S, Li S (eds) Medical Image Computing and Computer Assisted Intervention – MICCAI 2022. MICCAI 2022. Lecture Notes in Computer Science, vol 13438, 725–735, 2022. https://doi.org/10.1007/978-3-031-16452-1_69 Nguyen K, Nguyen HH, Tiulpin A: AdaTriplet: Adaptive gradient triplet loss with automatic margin learning for forensic medical image matching. In: Wang L, Dou Q, Fletcher PT, Speidel S, Li S (eds) Medical Image Computing and Computer Assisted Intervention – MICCAI 2022. MICCAI 2022. Lecture Notes in Computer Science, vol 13438, 725–735, 2022. https://​doi.​org/​10.​1007/​978-3-031-16452-1_​69
38.
Zurück zum Zitat Suzuki T, Maki S, Yamazaki T, Wakita H, Toguchi Y, Horii M, Yamauchi T, Kawamura K, Aramomi M, Sugiyama H, Matsuura Y, Yamashita T, Orita S, Ohtori S: Detecting distal radial fractures from wrist radiographs using a deep convolutional neural network with an accuracy comparable to hand orthopedic surgeons. J Digit Imaging. 35:39-46, 2022. https://doi.org/10.1007/s10278-021-00519-1CrossRefPubMed Suzuki T, Maki S, Yamazaki T, Wakita H, Toguchi Y, Horii M, Yamauchi T, Kawamura K, Aramomi M, Sugiyama H, Matsuura Y, Yamashita T, Orita S, Ohtori S: Detecting distal radial fractures from wrist radiographs using a deep convolutional neural network with an accuracy comparable to hand orthopedic surgeons. J Digit Imaging. 35:39-46, 2022. https://​doi.​org/​10.​1007/​s10278-021-00519-1CrossRefPubMed
46.
Zurück zum Zitat Kawakubo M, Waki H, Shirasaka T, Kojima T, Mikayama R, Hamasaki H, Akamine H, Kato T, Baba S, Ushiro S, Ishigami K: A deep learning model based on fusion images of chest radiography and X-ray sponge images supports human visual characteristics of retained surgical items detection. Int J Comput Assist Radiol Surg 2022. https://doi.org/10.1007/s11548-022-02816-8.CrossRefPubMed Kawakubo M, Waki H, Shirasaka T, Kojima T, Mikayama R, Hamasaki H, Akamine H, Kato T, Baba S, Ushiro S, Ishigami K: A deep learning model based on fusion images of chest radiography and X-ray sponge images supports human visual characteristics of retained surgical items detection. Int J Comput Assist Radiol Surg 2022. https://​doi.​org/​10.​1007/​s11548-022-02816-8.CrossRefPubMed
48.
Zurück zum Zitat Finizola J, Targino J, Teodoro F, Lima C: Comparative study between deep face, autoencoder and traditional machine learning techniques aiming at biometric facial recognition. 2019 International Joint Conference on Neural Networks (IJCNN) 1–8, 2022. https://doi.org/10.1109/IJCNN.2019.8852273 Finizola J, Targino J, Teodoro F, Lima C: Comparative study between deep face, autoencoder and traditional machine learning techniques aiming at biometric facial recognition. 2019 International Joint Conference on Neural Networks (IJCNN) 1–8, 2022. https://​doi.​org/​10.​1109/​IJCNN.​2019.​8852273
50.
Zurück zum Zitat Wang X, Peng Y, Lu L, Lu Z, Bagheri M, Summers RM: ChestX-Ray8: Hospital-scale chest X-ray database and benchmarks on weakly-supervised classification and localization of common thorax diseases. 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Honolulu, HI, USA, 3462–3471, 2017. https://doi.org/10.1109/CVPR.2017.369 Wang X, Peng Y, Lu L, Lu Z, Bagheri M, Summers RM: ChestX-Ray8: Hospital-scale chest X-ray database and benchmarks on weakly-supervised classification and localization of common thorax diseases. 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Honolulu, HI, USA, 3462–3471, 2017. https://​doi.​org/​10.​1109/​CVPR.​2017.​369
52.
Zurück zum Zitat Irvin J, Rajpurkar P, Ko M, Yu Y, Ciurea-Ilcus S, Chute C, Marklund H, Haghgoo B, Ball R, Shpanskaya K, Seekins J. CheXpert: A large chest radiograph dataset with uncertainty labels and expert comparison. In Proceedings of the AAAI Conference on Artificial Intelligence 33:590-597, 2019. https://doi.org/10.1609/aaai.v33i01.3301590CrossRef Irvin J, Rajpurkar P, Ko M, Yu Y, Ciurea-Ilcus S, Chute C, Marklund H, Haghgoo B, Ball R, Shpanskaya K, Seekins J. CheXpert: A large chest radiograph dataset with uncertainty labels and expert comparison. In Proceedings of the AAAI Conference on Artificial Intelligence 33:590-597, 2019. https://​doi.​org/​10.​1609/​aaai.​v33i01.​3301590CrossRef
56.
Zurück zum Zitat Tan M, Le Q: EfficientNet: Rethinking model scaling for convolutional neural networks. Proceedings of the 36th International Conference on Machine Learning, ICML 2019. 6105–6114, 2019. Tan M, Le Q: EfficientNet: Rethinking model scaling for convolutional neural networks. Proceedings of the 36th International Conference on Machine Learning, ICML 2019. 6105–6114, 2019.
57.
Zurück zum Zitat Tan M, Le Q: EfficientNetV2: Smaller models and faster training. Proceedings of the 38th International Conference on Machine Learning, PMLR 139:10096–10106, 2021. Tan M, Le Q: EfficientNetV2: Smaller models and faster training. Proceedings of the 38th International Conference on Machine Learning, PMLR 139:10096–10106, 2021.
59.
Metadaten
Titel
Patient Identification Based on Deep Metric Learning for Preventing Human Errors in Follow-up X-Ray Examinations
verfasst von
Yasuyuki Ueda
Junji Morishita
Publikationsdatum
12.06.2023
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 5/2023
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-023-00850-9

Weitere Artikel der Ausgabe 5/2023

Journal of Digital Imaging 5/2023 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.