Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 7/2012

01.10.2012 | Original paper

Patterns of myocardial perfusion in humans evaluated with contrast-enhanced 320 multidetector computed tomography

verfasst von: J. Tobias Kühl, Jesper J. Linde, Andreas Fuchs, Thomas S. Kristensen, Henning Kelbæk, Richard T. George, Jens D. Hove, Klaus Fuglsang Kofoed

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 7/2012

Einloggen, um Zugang zu erhalten

Abstract

Left ventricular (LV) myocardial contrast enhancement can be recorded using 320 multi detector computed tomography (MDCT). We aimed to (1) assess patterns of regional myocardial perfusion at rest and compare them with NH3 positron emission tomography (PET) (2) and to assess the effect of intravenous adenosine infusion on regional myocardial perfusion. To evaluate myocardial perfusion patterns at rest, we scanned 14 healthy subjects with PET and 14 age and gender matched subjects with 320 MDCT. To evaluate the effect of adenosine stress on relative perfusion patterns 14 subjects with near-normal epicardial coronary arteries were studied at rest and during adenosine stress. Relative perfusion was assessed as attenuation density (AD) in 16 segments of the LV, and each segment was divided into 3 layers: endo-, mid- and epi-cardial. During rest the relative AD by MDCT was lower in the lateral wall compared with the remainder of the LV (P < 0.002). A similar pattern was found by PET-imaging. LV endocardial AD was higher than mid- and epicardial AD (P < 0.05). At rest the endocardial/epicardial ratio in the septum was 0.99 compared with 1.23 in non-septal segments (P < 0.001). During adenosine infusion transmural AD increased due to significant increases in the mid- and epicardium and the endocardial/epicardial ratio decreased by 18% in non-septal segments (from 1.23 to 1.05 P < 0.001). Relative perfusion at rest is lower in the lateral wall of the LV with both PET and MDCT compared to the remainder of the myocardium. During adenosine stress endocardial/epicardial ratio decrease significantly.
Literatur
1.
Zurück zum Zitat George RT, Jerosch-Herold M, Silva C, Kitagawa K, Bluemke DA, Lima JA, Lardo AC (2007) Quantification of myocardial perfusion using dynamic 64-detector computed tomography. Invest Radiol 42:815–822PubMedCrossRef George RT, Jerosch-Herold M, Silva C, Kitagawa K, Bluemke DA, Lima JA, Lardo AC (2007) Quantification of myocardial perfusion using dynamic 64-detector computed tomography. Invest Radiol 42:815–822PubMedCrossRef
2.
Zurück zum Zitat Rumberger JA, Feiring AJ, Lipton MJ, Higgins CB, Ell SR, Marcus ML (1987) Use of ultrafast computed tomography to quantitate regional myocardial perfusion: a preliminary report. J Am Coll Cardiol 9:59–69PubMedCrossRef Rumberger JA, Feiring AJ, Lipton MJ, Higgins CB, Ell SR, Marcus ML (1987) Use of ultrafast computed tomography to quantitate regional myocardial perfusion: a preliminary report. J Am Coll Cardiol 9:59–69PubMedCrossRef
3.
Zurück zum Zitat Wolfkiel CJ, Ferguson JL, Chomka EV, Law WR, Labin IN, Tenzer ML, Booker M, Brundage BH (1987) Measurement of myocardial blood flow by ultrafast computed tomography. Circulation 76:1262–1273PubMedCrossRef Wolfkiel CJ, Ferguson JL, Chomka EV, Law WR, Labin IN, Tenzer ML, Booker M, Brundage BH (1987) Measurement of myocardial blood flow by ultrafast computed tomography. Circulation 76:1262–1273PubMedCrossRef
4.
Zurück zum Zitat Blankstein R, Shturman LD, Rogers IS, Rocha-Filho JA, Okada DR, Sarwar A, Soni AV, Bezerra H, Ghoshhajra BB, Petranovic M, Loureiro R, Feuchtner G, Gewirtz H, Hoffmann U, Mamuya WS, Brady TJ, Cury RC (2009) Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography. J Am Coll Cardiol 54:1072–1084PubMedCrossRef Blankstein R, Shturman LD, Rogers IS, Rocha-Filho JA, Okada DR, Sarwar A, Soni AV, Bezerra H, Ghoshhajra BB, Petranovic M, Loureiro R, Feuchtner G, Gewirtz H, Hoffmann U, Mamuya WS, Brady TJ, Cury RC (2009) Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography. J Am Coll Cardiol 54:1072–1084PubMedCrossRef
5.
Zurück zum Zitat George RT, Rbab-Zadeh A, Miller JM, Kitagawa K, Chang HJ, Bluemke DA, Becker L, Yousuf O, Texter J, Lardo AC, Lima JA (2009) Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging 2:174–182PubMedCrossRef George RT, Rbab-Zadeh A, Miller JM, Kitagawa K, Chang HJ, Bluemke DA, Becker L, Yousuf O, Texter J, Lardo AC, Lima JA (2009) Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging 2:174–182PubMedCrossRef
6.
Zurück zum Zitat Okada DR, Ghoshhajra BB, Blankstein R, Rocha-Filho JA, Shturman LD, Rogers IS, Bezerra HG, Sarwar A, Gewirtz H, Hoffmann U, Mamuya WS, Brady TJ, Cury RC (2010) Direct comparison of rest and adenosine stress myocardial perfusion CT with rest and stress SPECT. J Nucl Cardiol 17:27–37PubMedCrossRef Okada DR, Ghoshhajra BB, Blankstein R, Rocha-Filho JA, Shturman LD, Rogers IS, Bezerra HG, Sarwar A, Gewirtz H, Hoffmann U, Mamuya WS, Brady TJ, Cury RC (2010) Direct comparison of rest and adenosine stress myocardial perfusion CT with rest and stress SPECT. J Nucl Cardiol 17:27–37PubMedCrossRef
7.
Zurück zum Zitat Rocha-Filho JA, Blankstein R, Shturman LD, Bezerra HG, Okada DR, Rogers IS, Ghoshhajra B, Hoffmann U, Feuchtner G, Mamuya WS, Brady TJ, Cury RC (2010) Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography. Radiology 254:410–419PubMedCrossRef Rocha-Filho JA, Blankstein R, Shturman LD, Bezerra HG, Okada DR, Rogers IS, Ghoshhajra B, Hoffmann U, Feuchtner G, Mamuya WS, Brady TJ, Cury RC (2010) Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography. Radiology 254:410–419PubMedCrossRef
8.
Zurück zum Zitat Rodriguez-Granillo GA, Rosales MA, Degrossi E, Rodriguez AE (2010) Signal density of left ventricular myocardial segments and impact of beam hardening artifact: implications for myocardial perfusion assessment by multidetector CT coronary angiography. Int J Cardiovasc Imaging 26:345–354PubMedCrossRef Rodriguez-Granillo GA, Rosales MA, Degrossi E, Rodriguez AE (2010) Signal density of left ventricular myocardial segments and impact of beam hardening artifact: implications for myocardial perfusion assessment by multidetector CT coronary angiography. Int J Cardiovasc Imaging 26:345–354PubMedCrossRef
9.
Zurück zum Zitat Kitagawa K, George RT, rbab-Zadeh A, Lima JA, Lardo AC (2010) Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion. Radiology 256:111–118PubMedCrossRef Kitagawa K, George RT, rbab-Zadeh A, Lima JA, Lardo AC (2010) Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion. Radiology 256:111–118PubMedCrossRef
10.
Zurück zum Zitat George RT, Silva C, Cordeiro MA, DiPaula A, Thompson DR, McCarthy WF, Ichihara T, Lima JA, Lardo AC (2006) Multidetector computed tomography myocardial perfusion imaging during adenosine stress. J Am Coll Cardiol 48:153–160PubMedCrossRef George RT, Silva C, Cordeiro MA, DiPaula A, Thompson DR, McCarthy WF, Ichihara T, Lima JA, Lardo AC (2006) Multidetector computed tomography myocardial perfusion imaging during adenosine stress. J Am Coll Cardiol 48:153–160PubMedCrossRef
11.
Zurück zum Zitat Porenta G, Kuhle W, Czernin J, Ratib O, Brunken RC, Phelps ME, Schelbert HR (1992) Semiquantitative assessment of myocardial blood flow and viability using polar map displays of cardiac PET images. J Nucl Med 33:1628–1636PubMed Porenta G, Kuhle W, Czernin J, Ratib O, Brunken RC, Phelps ME, Schelbert HR (1992) Semiquantitative assessment of myocardial blood flow and viability using polar map displays of cardiac PET images. J Nucl Med 33:1628–1636PubMed
12.
Zurück zum Zitat Nieman K, Shapiro MD, Ferencik M, Nomura CH, Abbara S, Hoffmann U, Gold HK, Jang IK, Brady TJ, Cury RC (2008) Reperfused myocardial infarction: contrast-enhanced 64-Section CT in comparison to MR imaging. Radiology 247:49–56PubMedCrossRef Nieman K, Shapiro MD, Ferencik M, Nomura CH, Abbara S, Hoffmann U, Gold HK, Jang IK, Brady TJ, Cury RC (2008) Reperfused myocardial infarction: contrast-enhanced 64-Section CT in comparison to MR imaging. Radiology 247:49–56PubMedCrossRef
13.
Zurück zum Zitat de Jong RM, Blanksma PK, Willemsen AT, Anthonio RL, Meeder JG, Pruim J, Vaalburg W, Lie KI (1995) Posterolateral defect of the normal human heart investigated with nitrogen-13-ammonia and dynamic PET. J Nucl Med 36:581–585PubMed de Jong RM, Blanksma PK, Willemsen AT, Anthonio RL, Meeder JG, Pruim J, Vaalburg W, Lie KI (1995) Posterolateral defect of the normal human heart investigated with nitrogen-13-ammonia and dynamic PET. J Nucl Med 36:581–585PubMed
14.
Zurück zum Zitat Kofoed KF, Hove JD, Freiberg J, Host U, Hesse B, Kelbaek H (2001) Relationship between regional 18F-fluorodeoxyglucose and 13N ammonia uptake in normal myocardium assessed by positron emission tomography: patterns of mismatch and effects of aging. Int J Cardiovasc Imaging 17:361–370PubMedCrossRef Kofoed KF, Hove JD, Freiberg J, Host U, Hesse B, Kelbaek H (2001) Relationship between regional 18F-fluorodeoxyglucose and 13N ammonia uptake in normal myocardium assessed by positron emission tomography: patterns of mismatch and effects of aging. Int J Cardiovasc Imaging 17:361–370PubMedCrossRef
15.
Zurück zum Zitat Loghin C, Sdringola S, Gould KL (2004) Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: clinical significance, causes, and solutions. J Nucl Med 45:1029–1039PubMed Loghin C, Sdringola S, Gould KL (2004) Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: clinical significance, causes, and solutions. J Nucl Med 45:1029–1039PubMed
16.
Zurück zum Zitat Bastarrika G, Ramos-Duran L, Rosenblum MA, Kang DK, Rowe GW, Schoepf UJ (2010) Adenosine-stress dynamic myocardial CT perfusion imaging: initial clinical experience. Invest Radiol 45:306–313PubMedCrossRef Bastarrika G, Ramos-Duran L, Rosenblum MA, Kang DK, Rowe GW, Schoepf UJ (2010) Adenosine-stress dynamic myocardial CT perfusion imaging: initial clinical experience. Invest Radiol 45:306–313PubMedCrossRef
17.
Zurück zum Zitat Duncker DJ, Bache RJ (2008) Regulation of coronary blood flow during exercise. Physiol Rev 88:1009–1086PubMedCrossRef Duncker DJ, Bache RJ (2008) Regulation of coronary blood flow during exercise. Physiol Rev 88:1009–1086PubMedCrossRef
18.
Zurück zum Zitat Radjenovic A, Biglands JD, Larghat A, Ridgway JP, Ball SG, Greenwood JP, Jerosch-Herold M, Plein S (2010) Estimates of systolic and diastolic myocardial blood flow by dynamic contrast-enhanced MRI. Magn Reson Med 64:1696–1703PubMedCrossRef Radjenovic A, Biglands JD, Larghat A, Ridgway JP, Ball SG, Greenwood JP, Jerosch-Herold M, Plein S (2010) Estimates of systolic and diastolic myocardial blood flow by dynamic contrast-enhanced MRI. Magn Reson Med 64:1696–1703PubMedCrossRef
19.
Zurück zum Zitat James TN, Burge GE (1958) Blood supply of the human interventricular septum. Circulation 17:391–396PubMedCrossRef James TN, Burge GE (1958) Blood supply of the human interventricular septum. Circulation 17:391–396PubMedCrossRef
20.
Zurück zum Zitat Armstrong RB, Essen-Gustavsson B, Hoppeler H, Jones JH, Kayar SR, Laughlin MH, Lindholm A, Longworth KE, Taylor CR, Weibel ER (1992) O2 delivery at VO2 max and oxidative capacity in muscles of standardbred horses. J Appl Physiol 73:2274–2282PubMed Armstrong RB, Essen-Gustavsson B, Hoppeler H, Jones JH, Kayar SR, Laughlin MH, Lindholm A, Longworth KE, Taylor CR, Weibel ER (1992) O2 delivery at VO2 max and oxidative capacity in muscles of standardbred horses. J Appl Physiol 73:2274–2282PubMed
21.
Zurück zum Zitat Duncker DJ, Ishibashi Y, Bache RJ (1998) Effect of treadmill exercise on transmural distribution of blood flow in hypertrophied left ventricle. Am J Physiol 275:H1274–H1282PubMed Duncker DJ, Ishibashi Y, Bache RJ (1998) Effect of treadmill exercise on transmural distribution of blood flow in hypertrophied left ventricle. Am J Physiol 275:H1274–H1282PubMed
22.
Zurück zum Zitat Bache RJ, Cobb FR (1977) Effect of maximal coronary vasodilation on transmural myocardial perfusion during tachycardia in the awake dog. Circ Res 41:648–653PubMedCrossRef Bache RJ, Cobb FR (1977) Effect of maximal coronary vasodilation on transmural myocardial perfusion during tachycardia in the awake dog. Circ Res 41:648–653PubMedCrossRef
Metadaten
Titel
Patterns of myocardial perfusion in humans evaluated with contrast-enhanced 320 multidetector computed tomography
verfasst von
J. Tobias Kühl
Jesper J. Linde
Andreas Fuchs
Thomas S. Kristensen
Henning Kelbæk
Richard T. George
Jens D. Hove
Klaus Fuglsang Kofoed
Publikationsdatum
01.10.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 7/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9986-z

Weitere Artikel der Ausgabe 7/2012

The International Journal of Cardiovascular Imaging 7/2012 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.