Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 5/2013

01.05.2013 | Trauma Surgery

Percutaneous navigated screw fixation of glenoid fractures

verfasst von: Florian Gras, Ivan Marintschev, Matthias Aurich, Sascha Rausch, Kajetan Klos, Gunther O. Hofmann

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 5/2013

Einloggen, um Zugang zu erhalten

Abstract

Background

Open or percutaneous arthroscopic-based procedures are reported to fix unstable or displaced intra-articular glenoid fractures. Approach related morbidity has to be considered for open procedures, and arthroscopic-based procedures are demanding. Therefore an alternative percutaneous navigated approach is described.

Technical procedure

In an experimental setting an operative workflow was simulated to evaluate the best position of the patient on the operation table, the operating room set up and the fixation technique for the dynamic reference base of the navigation system. Based on two clinical cases, screw fixation of glenoid fractures via a posterior percutaneous approach is described, using a 2D-fluoroscopic based navigation system. Compared to the common approaches, the advantages and disadvantages of this procedure are discussed.

Conclusion

The described technique of percutaneous navigated screw fixation of glenoid fractures is an alternative minimal invasive procedure. A reduction of approach related morbidity and more rapid return to function could be expected. The intraoperative results and postoperative functional outcome of both cases are promising.
Literatur
1.
Zurück zum Zitat Mayo KA, Benirschke SK, Mast JW (1998) Displaced fractures of the glenoid fossa. Results of open reduction and internal fixation. Clin Orthop Relat Res 347:122–130PubMedCrossRef Mayo KA, Benirschke SK, Mast JW (1998) Displaced fractures of the glenoid fossa. Results of open reduction and internal fixation. Clin Orthop Relat Res 347:122–130PubMedCrossRef
2.
Zurück zum Zitat Goss TP (1992) Fractures of the glenoid cavity. J Bone Jt Surg Am 74:299–305 Goss TP (1992) Fractures of the glenoid cavity. J Bone Jt Surg Am 74:299–305
3.
Zurück zum Zitat Jones CB, Cornelius JP, Sietsema DL, Ringler JR, Endres TJ (2009) Modified Judet approach and minifragment fixation of scapular body and glenoid neck fractures. J Orthop Trauma 23:558–564PubMedCrossRef Jones CB, Cornelius JP, Sietsema DL, Ringler JR, Endres TJ (2009) Modified Judet approach and minifragment fixation of scapular body and glenoid neck fractures. J Orthop Trauma 23:558–564PubMedCrossRef
4.
Zurück zum Zitat Bauer G, Fleischmann W, Dussler E (1995) Displaced scapular fractures: indication and long-term results of open reduction and internal fixation. Arch Orthop Trauma Surg 114:215–219PubMedCrossRef Bauer G, Fleischmann W, Dussler E (1995) Displaced scapular fractures: indication and long-term results of open reduction and internal fixation. Arch Orthop Trauma Surg 114:215–219PubMedCrossRef
5.
Zurück zum Zitat Bauer T, Abadie O, Hardy P (2006) Arthroscopic treatment of glenoid fractures arthroscopy. J Arthrosc Relat Surg 22(569):e561–e566 Bauer T, Abadie O, Hardy P (2006) Arthroscopic treatment of glenoid fractures arthroscopy. J Arthrosc Relat Surg 22(569):e561–e566
6.
Zurück zum Zitat Raiss P, Baumann F, Akbar M, Rickert M, Loew M (2009) Open screw fixation of large anterior glenoid rim fractures: mid- and long-term results in 29 patients. Knee Surg Sports Traumatol Arthrosc 17:195–203PubMedCrossRef Raiss P, Baumann F, Akbar M, Rickert M, Loew M (2009) Open screw fixation of large anterior glenoid rim fractures: mid- and long-term results in 29 patients. Knee Surg Sports Traumatol Arthrosc 17:195–203PubMedCrossRef
7.
Zurück zum Zitat Marsland D, Ahmed HA (2011) Arthroscopically assisted fixation of glenoid fractures: a cadaver study to show potential applications of percutaneous screw insertion and anatomic risks. J Should Elb Surg 20:481–490CrossRef Marsland D, Ahmed HA (2011) Arthroscopically assisted fixation of glenoid fractures: a cadaver study to show potential applications of percutaneous screw insertion and anatomic risks. J Should Elb Surg 20:481–490CrossRef
8.
Zurück zum Zitat Ideberg R, Grevsten S, Larsson S (1995) Epidemiology of scapular fractures. Incidence and classification of 338 fractures. Acta Orthop Scand 66:395–397PubMedCrossRef Ideberg R, Grevsten S, Larsson S (1995) Epidemiology of scapular fractures. Incidence and classification of 338 fractures. Acta Orthop Scand 66:395–397PubMedCrossRef
9.
Zurück zum Zitat Rosenberger RE, Dolati B, Larndorfer R, Blauth M, Krappinger D, Bale RJ (2010) Accuracy of minimally invasive navigated acetabular and iliosacral fracture stabilization using a targeting and noninvasive registration device. Arch Orthop Trauma Surg 130:223–230PubMedCrossRef Rosenberger RE, Dolati B, Larndorfer R, Blauth M, Krappinger D, Bale RJ (2010) Accuracy of minimally invasive navigated acetabular and iliosacral fracture stabilization using a targeting and noninvasive registration device. Arch Orthop Trauma Surg 130:223–230PubMedCrossRef
10.
Zurück zum Zitat Gras F, Marintschev I, Klos K, Muckley T, Hofmann GO, Kahler DM (2012) Screw placement for acetabular fractures; which navigation modality (2-dimensional vs. 3-dimensional) should be used? an experimental study. J Orthop Trauma 26:466–473 Gras F, Marintschev I, Klos K, Muckley T, Hofmann GO, Kahler DM (2012) Screw placement for acetabular fractures; which navigation modality (2-dimensional vs. 3-dimensional) should be used? an experimental study. J Orthop Trauma 26:466–473
11.
Zurück zum Zitat Ohnsorge JA, Schkommodau E, Wirtz DC, Wildberger JE, Prescher A, Siebert CH (2003) Accuracy of fluoroscopically navigated drilling procedures at the hip. Z Orthop Ihre Grenzgeb 141:112–119PubMedCrossRef Ohnsorge JA, Schkommodau E, Wirtz DC, Wildberger JE, Prescher A, Siebert CH (2003) Accuracy of fluoroscopically navigated drilling procedures at the hip. Z Orthop Ihre Grenzgeb 141:112–119PubMedCrossRef
12.
Zurück zum Zitat Gramstad GD, Marra G (2002) Treatment of glenoid fractures. Tech Should Elb Surg 3:102–110CrossRef Gramstad GD, Marra G (2002) Treatment of glenoid fractures. Tech Should Elb Surg 3:102–110CrossRef
13.
Zurück zum Zitat Bicknell RT, DeLude JA, Kedgley AE, Ferreira LM, Dunning CE, King GJ, Faber KJ, Johnson JA, Drosdowech DS (2007) Early experience with computer-assisted shoulder hemiarthroplasty for fractures of the proximal humerus: development of a novel technique and an in vitro comparison with traditional methods. J Should Elb Surg 16:S117–S125CrossRef Bicknell RT, DeLude JA, Kedgley AE, Ferreira LM, Dunning CE, King GJ, Faber KJ, Johnson JA, Drosdowech DS (2007) Early experience with computer-assisted shoulder hemiarthroplasty for fractures of the proximal humerus: development of a novel technique and an in vitro comparison with traditional methods. J Should Elb Surg 16:S117–S125CrossRef
14.
Zurück zum Zitat Edwards TB, Gartsman GM, O’Connor DP, Sarin VK (2008) Safety and utility of computer-aided shoulder arthroplasty. J Should Elb Surg 17:503–508CrossRef Edwards TB, Gartsman GM, O’Connor DP, Sarin VK (2008) Safety and utility of computer-aided shoulder arthroplasty. J Should Elb Surg 17:503–508CrossRef
15.
Zurück zum Zitat Kedgley AE, DeLude JA, Drosdowech DS, Johnson JA, Bicknell RT (2008) Humeral head translation during glenohumeral abduction following computer-assisted shoulder hemiarthroplasty. J Bone Jt Surg Brit 90:1256–1259CrossRef Kedgley AE, DeLude JA, Drosdowech DS, Johnson JA, Bicknell RT (2008) Humeral head translation during glenohumeral abduction following computer-assisted shoulder hemiarthroplasty. J Bone Jt Surg Brit 90:1256–1259CrossRef
16.
Zurück zum Zitat Kircher J, Wiedemann M, Magosch P, Lichtenberg S, Habermeyer P (2009) Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: a prospective-randomized clinical study. J Should Elb Surg 18:515–520CrossRef Kircher J, Wiedemann M, Magosch P, Lichtenberg S, Habermeyer P (2009) Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: a prospective-randomized clinical study. J Should Elb Surg 18:515–520CrossRef
17.
Zurück zum Zitat Nguyen D, Ferreira LM, Brownhill JR, King GJ, Drosdowech DS, Faber KJ, Johnson JA (2009) Improved accuracy of computer assisted glenoid implantation in total shoulder arthroplasty: an in vitro randomized controlled trial. J Should Elb Surg 18:907–914CrossRef Nguyen D, Ferreira LM, Brownhill JR, King GJ, Drosdowech DS, Faber KJ, Johnson JA (2009) Improved accuracy of computer assisted glenoid implantation in total shoulder arthroplasty: an in vitro randomized controlled trial. J Should Elb Surg 18:907–914CrossRef
18.
Zurück zum Zitat Verborgt O, De Smedt T, Vanhees M, Clockaerts S, Parizel PM, Van Glabbeek F (2011) Accuracy of placement of the glenoid component in reversed shoulder arthroplasty with and without navigation. J Should Elb Surg 20:21–26CrossRef Verborgt O, De Smedt T, Vanhees M, Clockaerts S, Parizel PM, Van Glabbeek F (2011) Accuracy of placement of the glenoid component in reversed shoulder arthroplasty with and without navigation. J Should Elb Surg 20:21–26CrossRef
19.
Zurück zum Zitat Koulalis D, Kendoff D, Citak M, O’Loughlin PF, Pearle AD (2011) Freehand versus navigated glenoid anchor positioning in anterior labral repair arthoscopy. Knee Surg Sports Traumatol Arthrosc 19:1554–1557PubMedCrossRef Koulalis D, Kendoff D, Citak M, O’Loughlin PF, Pearle AD (2011) Freehand versus navigated glenoid anchor positioning in anterior labral repair arthoscopy. Knee Surg Sports Traumatol Arthrosc 19:1554–1557PubMedCrossRef
20.
Zurück zum Zitat Itoi E, Lee SB, Berglund LJ, Berge LL, An KN (2000) The effect of a glenoid defect on antero-inferior stability of the shoulder after Bankart repair: a cadaveric study. J Bone Jt Surg Am 82:35–46 Itoi E, Lee SB, Berglund LJ, Berge LL, An KN (2000) The effect of a glenoid defect on antero-inferior stability of the shoulder after Bankart repair: a cadaveric study. J Bone Jt Surg Am 82:35–46
21.
Zurück zum Zitat Scheibel M, Magosch P, Lichtenberg S, Habermeyer P (2004) Open reconstruction of anterior glenoid rim fractures. Knee Surg Sports Traumatol Arthrosc 12:568–573PubMedCrossRef Scheibel M, Magosch P, Lichtenberg S, Habermeyer P (2004) Open reconstruction of anterior glenoid rim fractures. Knee Surg Sports Traumatol Arthrosc 12:568–573PubMedCrossRef
22.
Zurück zum Zitat Carro LP, Nunez MP, Llata JI (1999) Arthroscopic-assisted reduction and percutaneous external fixation of a displaced intra-articular glenoid fracture arthroscopy. J arthrosc Relat Surg 15:211–214 Carro LP, Nunez MP, Llata JI (1999) Arthroscopic-assisted reduction and percutaneous external fixation of a displaced intra-articular glenoid fracture arthroscopy. J arthrosc Relat Surg 15:211–214
23.
Zurück zum Zitat Gigante A, Marinelli M, Verdenelli A, Lupetti E, Greco F (2003) Arthroscopy-assisted reduction and percutaneous fixation of a multiple glenoid fracture. Knee Surg Sports Traumatol Arthrosc 11:112–115PubMed Gigante A, Marinelli M, Verdenelli A, Lupetti E, Greco F (2003) Arthroscopy-assisted reduction and percutaneous fixation of a multiple glenoid fracture. Knee Surg Sports Traumatol Arthrosc 11:112–115PubMed
24.
Zurück zum Zitat Cameron SE (1998) Arthroscopic reduction and internal fixation of an anterior glenoid fracture. J Arthrosc Relat Surg 14:743–746CrossRef Cameron SE (1998) Arthroscopic reduction and internal fixation of an anterior glenoid fracture. J Arthrosc Relat Surg 14:743–746CrossRef
25.
Zurück zum Zitat Yallapragada R, Patel K, Davuluri P, Sloan A, Marynissen H (2007) Arthroscopy-assisted percutaneous fixation of glenoid fossa fracture. Int J Should Surg 1:96–99CrossRef Yallapragada R, Patel K, Davuluri P, Sloan A, Marynissen H (2007) Arthroscopy-assisted percutaneous fixation of glenoid fossa fracture. Int J Should Surg 1:96–99CrossRef
26.
Zurück zum Zitat Yang HB, Wang D, He XJ (2011) Arthroscopic-assisted reduction and percutaneous cannulated screw fixation for Ideberg type III glenoid fractures: a minimum 2-year follow-up of 18 cases. Am J Sports Med 39:1923–1928PubMedCrossRef Yang HB, Wang D, He XJ (2011) Arthroscopic-assisted reduction and percutaneous cannulated screw fixation for Ideberg type III glenoid fractures: a minimum 2-year follow-up of 18 cases. Am J Sports Med 39:1923–1928PubMedCrossRef
27.
Zurück zum Zitat Frush TJ, Hasan SS (2010) Arthroscopic reduction and cannulated screw fixation of a large anterior glenoid rim fracture. J Should Elb Surg 19:e16–e19CrossRef Frush TJ, Hasan SS (2010) Arthroscopic reduction and cannulated screw fixation of a large anterior glenoid rim fracture. J Should Elb Surg 19:e16–e19CrossRef
28.
Zurück zum Zitat Gras F, Marintschev I, Klos K, Fujak A, Muckley T, Hofmann GO (2010) Navigated Percutaneous Screw Fixation of a Periprosthetic Acetabular Fracture. J Arthroplast 25(1169):e1161–e1164 Gras F, Marintschev I, Klos K, Fujak A, Muckley T, Hofmann GO (2010) Navigated Percutaneous Screw Fixation of a Periprosthetic Acetabular Fracture. J Arthroplast 25(1169):e1161–e1164
29.
Zurück zum Zitat Atesok K, Schemitsch EH (2010) Computer-assisted trauma surgery. J Am Acad Orthop Surg 18:247–258PubMed Atesok K, Schemitsch EH (2010) Computer-assisted trauma surgery. J Am Acad Orthop Surg 18:247–258PubMed
Metadaten
Titel
Percutaneous navigated screw fixation of glenoid fractures
verfasst von
Florian Gras
Ivan Marintschev
Matthias Aurich
Sascha Rausch
Kajetan Klos
Gunther O. Hofmann
Publikationsdatum
01.05.2013
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 5/2013
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-013-1699-4

Weitere Artikel der Ausgabe 5/2013

Archives of Orthopaedic and Trauma Surgery 5/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.