Skip to main content
Erschienen in: Journal of Nuclear Cardiology 3/2018

01.06.2018 | Original Article

Prognosis of stress-only SPECT myocardial perfusion imaging with prone imaging

verfasst von: Ariel Gutstein, MD, Tamir Bental, MD, Ajejandro Solodky, MD, Israel Mats, MD, Nili Zafrir, MD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

Background

Stress-only single-photon emission computed tomography myocardial perfusion imaging (SO SPECT MPI) is associated with similarly benign prognosis as stress-rest SPECT MPI. However, previous studies have used attenuation correction rather than prone imaging to increase the rate of SO studies.

Objectives

To assess the prognosis of SO SPECT MPI performed with prone imaging.

Methods

We performed a retrospective cohort analysis of all patients who underwent a Tc-99m gated SPECT MPI over a 58-month period.

Results

Two thousand four hundred and sixty five patients were followed up. Of them, 1114 (45.2%) patients had a SO supine test, 388 (15.7%) underwent a SO supine and prone test, and the remaining 963 (39.1%) patients underwent a full stress-rest SPECT MPI. There was a similar annual mortality rate between the SO supine/prone group (1.3%), the SO supine (1.5%), and the stress-rest (1.5%) group (P = 0.47). Patients in the stress-rest group were significantly more likely to suffer from myocardial infarction (MI) as compared to the other two groups with an annual rate of 0.7% as compared to 0.4% (P = 0.049).

Conclusions

Normal supine-prone SO SPECT MPI is associated with a similarly benign prognosis as stress-rest SPECT MPI. The adjunction of prone imaging to the stress supine significantly increases the rate of SO SPECT MPI
Literatur
1.
Zurück zum Zitat Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/ SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foun- dation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol 2009;53:2201-29.CrossRefPubMed Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/ SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foun- dation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol 2009;53:2201-29.CrossRefPubMed
2.
Zurück zum Zitat Henzlova MJ, Croft LB, Duvall WL. Stress-only imaging: Faster, cheaper, less radiation. So what’s the hold up? J Nucl Cardiol 2012;19:1092-3.CrossRef Henzlova MJ, Croft LB, Duvall WL. Stress-only imaging: Faster, cheaper, less radiation. So what’s the hold up? J Nucl Cardiol 2012;19:1092-3.CrossRef
3.
Zurück zum Zitat Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.CrossRefPubMed Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.CrossRefPubMed
4.
Zurück zum Zitat Thompson RC, Cullom SJ. Issues regarding radiation dosage of cardiac nuclear and radiography procedures. J Nucl Cardiol 2006;13:19-23.CrossRefPubMed Thompson RC, Cullom SJ. Issues regarding radiation dosage of cardiac nuclear and radiography procedures. J Nucl Cardiol 2006;13:19-23.CrossRefPubMed
5.
Zurück zum Zitat Bhavnani SP, Heller GV. Stress-only myocardial perfusion imaging…it is time for a change! J Nucl Cardiol 2011;18:836-9.CrossRefPubMed Bhavnani SP, Heller GV. Stress-only myocardial perfusion imaging…it is time for a change! J Nucl Cardiol 2011;18:836-9.CrossRefPubMed
6.
Zurück zum Zitat Mahmarian JJ. Stress only myocardial perfusion imaging: Is it time for a change? J Nucl Cardiol 2010;17:529-35.CrossRefPubMed Mahmarian JJ. Stress only myocardial perfusion imaging: Is it time for a change? J Nucl Cardiol 2010;17:529-35.CrossRefPubMed
7.
Zurück zum Zitat Iskandrian AE. Stress-only myocardial perfusion imaging a new paradigm. J Am Coll Cardiol 2010;55:231-3.CrossRefPubMed Iskandrian AE. Stress-only myocardial perfusion imaging a new paradigm. J Am Coll Cardiol 2010;55:231-3.CrossRefPubMed
8.
Zurück zum Zitat Duvall WL, Guma KA, Kamen J, Croft LB, Parides M, George T, et al. Reduction in occupational and patient radiation exposure from myocardial perfusion imaging: Impact of stress-only imaging and high-efficiency SPECT camera technology. J Nucl Med 2013;54:1251-7.CrossRefPubMed Duvall WL, Guma KA, Kamen J, Croft LB, Parides M, George T, et al. Reduction in occupational and patient radiation exposure from myocardial perfusion imaging: Impact of stress-only imaging and high-efficiency SPECT camera technology. J Nucl Med 2013;54:1251-7.CrossRefPubMed
9.
Zurück zum Zitat Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress- only versus standard stress/rest myocardial perfusion imaging: Similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55:221-30.CrossRefPubMed Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress- only versus standard stress/rest myocardial perfusion imaging: Similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55:221-30.CrossRefPubMed
10.
Zurück zum Zitat Gibson PB, Demus D, Noto R, Hudson W, Johnson LL. Low event rate for stress-only perfusion imaging in patients evaluated for chest pain. J Am Coll Cardiol 2002;39:999-1004.CrossRefPubMed Gibson PB, Demus D, Noto R, Hudson W, Johnson LL. Low event rate for stress-only perfusion imaging in patients evaluated for chest pain. J Am Coll Cardiol 2002;39:999-1004.CrossRefPubMed
11.
Zurück zum Zitat Mathur S, Heller GV, Bateman TM, Ruffin R, Yekta A, Katten D, et al. Clinical value of stress-only Tc-99m SPECT imaging: Importance of attenuation correction. J Nucl Cardiol 2013;20:27-37.CrossRefPubMed Mathur S, Heller GV, Bateman TM, Ruffin R, Yekta A, Katten D, et al. Clinical value of stress-only Tc-99m SPECT imaging: Importance of attenuation correction. J Nucl Cardiol 2013;20:27-37.CrossRefPubMed
12.
Zurück zum Zitat Duvall WL, Wijetunga MN, Klein TM, Hingorani R, Bewley B, Khan SM, et al. Stress-only Tc-99m myocardial perfusion imaging in an Emergency Department Chest Pain Unit. J Emerg Med 2011;42:642-50.CrossRefPubMed Duvall WL, Wijetunga MN, Klein TM, Hingorani R, Bewley B, Khan SM, et al. Stress-only Tc-99m myocardial perfusion imaging in an Emergency Department Chest Pain Unit. J Emerg Med 2011;42:642-50.CrossRefPubMed
13.
Zurück zum Zitat Tragardh E, Valind S, Edenbrandt L. Adding attenuation corrected images in myocardial perfusion imaging reduces the need for a rest study. BMC Med Imaging 2013;13:14.CrossRefPubMedPubMedCentral Tragardh E, Valind S, Edenbrandt L. Adding attenuation corrected images in myocardial perfusion imaging reduces the need for a rest study. BMC Med Imaging 2013;13:14.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Duvall WL, Wijetunga MN, Klein TM, Razzouk L, Godbold J, Croft LB, et al. The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study. J Nucl Cardiol 2010;17:370-7.CrossRefPubMed Duvall WL, Wijetunga MN, Klein TM, Razzouk L, Godbold J, Croft LB, et al. The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study. J Nucl Cardiol 2010;17:370-7.CrossRefPubMed
15.
Zurück zum Zitat Ueyama T, Takehana K, Maeba H, Iwasaka T. Prognostic value of normal stress-only technetium-99 m myocardial perfusion imaging protocol comparison with standard stress-rest protocol. Circ Jpn 2012;76:2386-91.CrossRef Ueyama T, Takehana K, Maeba H, Iwasaka T. Prognostic value of normal stress-only technetium-99 m myocardial perfusion imaging protocol comparison with standard stress-rest protocol. Circ Jpn 2012;76:2386-91.CrossRef
16.
Zurück zum Zitat Slomka PJ, Berman DS, Germano G. New cardiac cameras: single-photon emission CT and PET. Semin Nucl Med 2014;44:232-51.CrossRefPubMed Slomka PJ, Berman DS, Germano G. New cardiac cameras: single-photon emission CT and PET. Semin Nucl Med 2014;44:232-51.CrossRefPubMed
17.
Zurück zum Zitat Nishina H, Slomka PJ, Abidov A, Yoda S, Akincioglu C, Kang X, et al. Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8.PubMed Nishina H, Slomka PJ, Abidov A, Yoda S, Akincioglu C, Kang X, et al. Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8.PubMed
18.
Zurück zum Zitat Hayes SW, De Lorenzo A, Hachamovitch R, Dhar SC, Hsu P, Cohen I, et al. Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT. J Nucl Med 2003;44:1633-40.PubMed Hayes SW, De Lorenzo A, Hachamovitch R, Dhar SC, Hsu P, Cohen I, et al. Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT. J Nucl Med 2003;44:1633-40.PubMed
19.
Zurück zum Zitat Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 2002;105:539-42.CrossRefPubMed Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 2002;105:539-42.CrossRefPubMed
20.
Zurück zum Zitat Gal R, Ahmad M. Cost-saving approach to normal technetium- 99m sestamibi myocardial perfusion scan. Am J Cardiol 1996;78:1047-9.CrossRefPubMed Gal R, Ahmad M. Cost-saving approach to normal technetium- 99m sestamibi myocardial perfusion scan. Am J Cardiol 1996;78:1047-9.CrossRefPubMed
21.
Zurück zum Zitat Ferreira MJ, Cunha MJ, Albuquerque A, Moreira AP, Ramos D, Costa G, et al. Prognosis of normal stress-only gated-SPECT myocardial perfusion imaging: A single center study. Int J Cardiovasc Imaging 2013;29:1639-44.CrossRefPubMed Ferreira MJ, Cunha MJ, Albuquerque A, Moreira AP, Ramos D, Costa G, et al. Prognosis of normal stress-only gated-SPECT myocardial perfusion imaging: A single center study. Int J Cardiovasc Imaging 2013;29:1639-44.CrossRefPubMed
22.
Zurück zum Zitat Einstein AJ, Johnson LL, DeLuca AJ, Kontak AC, Groves DW, Stant J, Pozniakoff T, Cheng B, Rabbani LE, Bokhari S. Radiation dose and prognosis of ultra-low-dose stress-first myocardial perfusion SPECT in patients with chest pain using a high-efficiency camera. J Nucl Med 2015;56:545-51.CrossRefPubMed Einstein AJ, Johnson LL, DeLuca AJ, Kontak AC, Groves DW, Stant J, Pozniakoff T, Cheng B, Rabbani LE, Bokhari S. Radiation dose and prognosis of ultra-low-dose stress-first myocardial perfusion SPECT in patients with chest pain using a high-efficiency camera. J Nucl Med 2015;56:545-51.CrossRefPubMed
23.
Zurück zum Zitat Malkerneker D, Brenner R, Martin WH, Sampson UK, Feurer ID, Kronenberg MW, et al. CT-based attenuation correction versus prone imaging to decrease equivocal interpretations of rest/stress Tc-99m tetrofosmin SPECT MPI. J Nucl Cardiol 2007;14:314-23.CrossRefPubMed Malkerneker D, Brenner R, Martin WH, Sampson UK, Feurer ID, Kronenberg MW, et al. CT-based attenuation correction versus prone imaging to decrease equivocal interpretations of rest/stress Tc-99m tetrofosmin SPECT MPI. J Nucl Cardiol 2007;14:314-23.CrossRefPubMed
Metadaten
Titel
Prognosis of stress-only SPECT myocardial perfusion imaging with prone imaging
verfasst von
Ariel Gutstein, MD
Tamir Bental, MD
Ajejandro Solodky, MD
Israel Mats, MD
Nili Zafrir, MD
Publikationsdatum
01.06.2018
Verlag
Springer US
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 3/2018
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-016-0617-x

Weitere Artikel der Ausgabe 3/2018

Journal of Nuclear Cardiology 3/2018 Zur Ausgabe

VHF-Ablation nützt wohl nur bei reduzierter Auswurfleistung

02.05.2024 Ablationstherapie Nachrichten

Ob die Katheterablation von Vorhofflimmern bei Patienten mit Herzinsuffizienz die Komplikationsraten senkt, scheint davon abzuhängen, ob die Auswurfleistung erhalten ist oder nicht. Das legen die Ergebnisse einer Metaanalyse nahe.

Das Risiko für Vorhofflimmern in der Bevölkerung steigt

02.05.2024 Vorhofflimmern Nachrichten

Das Risiko, im Lauf des Lebens an Vorhofflimmern zu erkranken, ist in den vergangenen 20 Jahren gestiegen: Laut dänischen Zahlen wird es drei von zehn Personen treffen. Das hat Folgen weit über die Schlaganfallgefährdung hinaus.

Weniger Extremitätenischämien mit dualer Plättchenhemmung

02.05.2024 Thrombozytenaggregationshemmer Nachrichten

Eine Behandlung mit Ticagrelor zusätzlich zu ASS kann das Risiko für Revaskularisierungen und Amputationen von Extremitäten bei Diabetikern mit stabiler KHK deutlich reduzieren, vor allem für solche mit PAVK. Dafür spricht eine Auswertung der Interventionsstudie THEMIS.

Beutel versus Maschine: Beste Beatmungstechnik bei Herzstillstand gesucht

02.05.2024 Kardiopulmonale Reanimation Nachrichten

Stehen die Chancen auf eine Rückkehr der Spontanzirkulation nach Herz-Kreislauf-Stillstand bei manueller oder maschineller Beatmung besser? Und unterscheidet sich das neurologische Outcome nach der Reanimation? Das belgische Herzstillstand-Register liefert die Daten für einen direkten Vergleich zwischen Beutel und Beatmungsgerät.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.