Open Access 01.12.2018 | Research article

Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China

verfasst von: Armah M Akuffu, Haige Zhao, Junnan Zheng, Yiming Ni

Erschienen in: Journal of Cardiothoracic Surgery | Ausgabe 1/2018

Abstract

Background

Prosthesis–patient mismatch (PPM) may affect the clinical outcomes of patients undergoing mitral valve replacement (MVR) surgery. We aimed to investigate the incidence of PPM of the mitral position in our center and analyze the possible predictors of PPM as well as its effect on short-term outcomes.

Methods

We retrospectively examined all consecutive patients with isolated or concomitant MVR at our center from 2013 to 2015. PPM was defined as an indexed effective orifice area (iEOA) of ≤1.2 cm2/m2. After inclusion and exclusion, a total of 1067 patients were analyzed. The baseline information were collected and compared between the two groups. Multivariate logistic regression analysis was conducted to determine the preoperative predictors of PPM as well as the effect of PPM on early mortality.

Results

A total of 1067 patients were included in the study. PPM was detected in 15.9% of the patients while 12 patients (1.12%) met the criteria for severe PPM. Patients with PPM compared to the non-PPM patients had higher age, larger body surface area and were more likely to be male and obese. Logistic regression analysis showed that higher age, larger BSA, bioprosthesis and smaller left ventricle end-diastolic diameter were predictors of PPM. There were no significant differences between the PPM and non-PPM groups regarding post-operative complications. Logistic regression analysis showed that PPM was not a risk factor of short-term mortality (P = 0.654). Also, there were no significant differences regarding short−/mid-term heart function between the PPM and non PPM groups (P = 0.902).

Conclusions

Our results demonstrated that higher age, bioprosthesis, larger BSA and smaller left ventricle size were associated with mitral PPM. However, PPM was not associated with poorer early outcomes after MVR surgery. In eastern of China, the prevalence of mitral valve stenosis is high; therefore, whether the standard PPM criteria are suitable for patients of this district needs to be further verified.
Abkürzungen
AF
Atrial fibrillation
AFRA
Atrial fibrillation radio frequency surgery
BMI
Body mass index
BSA
Body surface are
CABG
Coronary artery bypass grafting
CABG
Coronary artery bypass grafting
CI
Confidence interval
CPB
Cardiopulmonary bypass
EOA
Effective orifice area
EOAi (iEOA)
Effective orifice area index
ICU
Intensive care unit
LAD
Left atrial diameter
LVDd
Left ventricular diastolic diameter
LVEF
Left ventricular ejection fracture
LVESV
Left ventricular end-systolic volume
MR
Mitral valve regurgitation
MVR
mitral valve replacement
NS
Not significant
NYHA
New York Heart Association
OR
Odd ratio
PHM
Prosthesis-patient mismatch
PPM
Prosthesis-patient mismatch
SD
Standard deviation

Background

The phenomenon of prosthesis-patient mismatch (PPM) was initially described by Rahimtoola and Murphy about 40 years ago [1, 2]. Currently, PPM is considered a condition in which the effective orifice area (EOA) of the implanted valve prosthesis does not match the patient’s body size.
PPM of the aortic position has been proved to be associated with poorer outcomes including long- and short-term cardiac death [35]. However, PPM following mitral valve replacement (MVR) has still been less investigated.
In recent years, PPM after MVR has attracted more and more attention from researchers. Researches has shown that the EOA of mitral valve prosthesis is often too small in relation to body size, thus, normally functioning mitral prosthesis often has relatively high transvalvular gradients similar to those found in mild to moderate mitral valve stenosis patients [610].
In East Asia, where rheumatic mitral valve stenosis is very common, the mitral valve annulus in patients is relatively small; therefore more patients meet the standard of mitral PPM [11]. We aim to investigate the incidence of PPM of the mitral position in our center and analyze the possible predictors of PPM as well as its effect on short-term outcomes. We will also discuss the eligibility of the current PPM standard for this population.

Methods

Patient population and data collection

We retrospectively reviewed all consecutive patients who underwent elective isolated or concomitant MVR at our center, the Department of Cardiothoracic Surgery, the First Affiliated Hospital, Zhejiang University, School of Medicine, from January 2013 to December 2015. Written informed consent waivers obtained from the Hospital Review Board were completed by all patients.
We analyzed all consecutive patients aged more than 18 years undergoing isolated MVR or MVR concomitant with other non-valve-replacement procedures. Patients with incomplete clinical data or patients who received MVR due to failed mitral valvuloplasty were excluded (Fig. 1).
In total, 1067 patients were included in this study. Baseline, intraoperative and outcome data were prospectively collected and validated, which were queried retrospectively. 30-month postoperative follow-up was conducted for discharged patients at the outpatient clinic. Patients who did not show up at the visit were contacted by telephone.

PPM definition and EOA index (EOAi) calculation

Body surface area (BSA) of the patients was calculated using the Dubois formula. The EOA of the mitral valve prosthesis was derived from in vitro measurements provided by the manufacturers and from scientific publications, as outlined in Table 1.
Table 1
In vivo effective orifice area values (cm2) corresponding to each valve
Valve prosthesis
patients
23 mm
25 mm
27 mm
29 mm
31 mm
33 mm
Ref
Mechanical
868
       
 CarboMedics Orbis Universal
680
1.8
2.2
2.2
2.4
2.4
2.3
[12]
 St.Jude Master series
154
1.0
1.5
1.8
1.8
2.0
2.0
[13, 21]
 ATS open pivot
33
1.8
2.8
2.8
2.9
2.9
[22]
Bioprosthesis
199
       
 Medtronics Hancock II
110
1.5
1.8
1.9
2.6
2.6
[12]
 Medtronics Mosaic
5
1.5
1.7
1.9
1.9
[13]
 St. Jude Bicor Stented
45
1.4
1.5
2.3
2.2
2.3
[23]
 Carpentier-Edwards perimount
39
1.7
1.9
2.3
2.8
2.7
[12]
Ref: reference
EOAi (also called indexed effective orifice area, iEOA) was obtained with EOA divided by BSA. Mitral PPM was defined as EOAi ≤1.2 cm2/m2. EOAi ≤0.9 cm2/m2 was considered severe mitral PPM.
Other definitions were listed as follows. Chronic renal insufficiency: serum creatinine ≥2 mg/dl. Peripheral arterial disease: claudication, carotid stenosis > 50% or previous/planned intervention on the abdominal aorta, limb arteries or carotids. Coronary artery disease: ≥ 50% reduction in one or more coronary vessels in single or multiple plane angiographic images. Emergency surgery: operation required within 24 h of onset of symptoms. Postoperative renal failure: increase in baseline creatinine greater than 2 mg/dl.

Surgical technique and prosthesis application

The operation records of all patients were reviewed. A total of 868 mechanical valve prostheses and 199 bioprostheses were implanted. The following prostheses were used in as followings:
Mechanical prosthesis: CarboMedics Orbis Universal (CarboMedics, Inc., Austin, TX, USA) (n = 679); St Jude Master (St Jude Medical, Inc., St Paul, MN, USA) (n = 154); ATS open pivot (ATS Medical, Inc., Minneapolis, MN, USA) (n = 33); Bioprosthesis: Hancock II Porcine Bioprosthesis (Medtronic, Inc., Minneapolis, MN, USA) (n = 110); Mosaic Porcine Bioprosthetic Valves (Medtronic, Inc., Minneapolis, MN, USA) (n = 5); Bicor Stented Bioprosthesis (St Jude Medical, Inc., St Paul, MN, USA) (n = 45); Carpentier-Edwards perimount (Baxter Healthcare Corp., Edwards Division, Santa Ana, CA, USA) (n = 39).
An isolated or concomitant MVR was performed in all patients. Concomitant procedures included tricuspid valvuloplasty, coronary artery bypass grafting, atrial septum defect repair and/or other procedures. Standard anesthesia and cardiopulmonary bypass methods were implemented. Most of the patients were approached through a full median sternotomy followed by an antegrade 4:1 cold blood cardioplegia for myocardial protection. Antegrade plus retrograde cardioplegia was applied for patients with coronary stenosis. Intermittent perfusion of cold blood cardioplegia was maintained at a frequency of once every 20 min.
After consulting with the patients preoperatively, the final decision of the type of prosthesis was made by the surgeons during operation, taking into consideration the preoperative information and intraoperative findings. When performing the MVR, sub-valvular structures were preserved as much as possible.

Statistical analysis

The Kolmogorov-Smirnov test was used to verify the distribution of all the quantitative variables. Gaussian distributed continuous variables were presented as mean ± standard deviation (SD), while non-Gaussian distributed variables were presented as medians (interquartile range). Categorical variables were expressed as an absolute number (percentage). Pearson’s χ2 test was used for descriptive, univariate statistics, such as the comparison of portions, while the Student’s unpaired t-test was used for normally distributed data comparisons. Otherwise, the Mann-Whitney U test was otherwise used for comparison of non-Gaussian distributed variables. Two-tailed P-values were derived from the calculated test statistics, and P ≤ 0.05 was considered statistically significant. Binary multivariate logistic regression analysis was performed to study the factors affecting PPM as well as mortality. IBM SPSS Statistics 20.0 software (IBM, Armonk, NY, USA) was used to analyze the data.

Results

Preoperative data and baseline information

A total of 1067 patients were included in this study. Mitral PPM was detected in 17.71% (189/1067) of the patients and only 12 (1.12%) patients met the criteria for severe PPM.
Compared with the non-PPM group, patients with PPM were older, taller and heavier and had a higher prevalence of male gender, hypertension, smoking history, coronary heart disease, and had a lower prevalence of mitral stenosis (Table 2).
Table 2
Preoperative patient baseline information
preoperative information
total
(n = 1067)
PPM group
(n = 189)
non-PPM group
(n = 878)
P value
Age, y
56(48–62)
63(55–67)
54(46–61)
< 0.001
Male
379(35.5%)
89(47.1%)
290(33.0%)
< 0.001
Height, cm
160.72 ± 7.82
163.26 ± 7.87
160.17 ± 7.71
< 0.001
Weight, kg
57.72 ± 10.33
62.42 ± 10.23
56.70 ± 10.07
< 0.001
BMI, kg/m2
22.29 ± 3.67
23.34 ± 2.86
22.07 ± 3.79
< 0.001
BSA, m2
1.57 ± 0.16
1.64 ± 0.17
1.55 ± 0.16
< 0.001
Smoking history
123(11.5%)
32(16.9%)
91(10.4%)
0.016
Diabetes
102(9.6%)
22(11.6%)
80(9.2%)
NS
Hypertention
192(18.0%)
47(24.9%)
145(16.5%)
0.009
Cerebrovascular accident
34(3.2%)
6(3.2%)
28(3.2%)
NS
Coronary heart disease
22(2.1%)
9(4.8%)
13(1.5%)
0.009
NYHA functional class (≥ III)
400(37.5%)
77(40.7%)
323(36.8%)
NS
Atrial fibrillation
533(50.0%)
92(48.7%)
441(50.2%)
NS
Previous cardiac surgery
54(5.1%)
8(4.2%)
46(5.2%)
NS
Previous MI
1(0.1%)
0(0.0%)
1(0.1%)
NS
Mitral stenosis
786(76.7%)
128(67.7%)
658(74.9%)
0.036
MR (moderate to severe)
470(44.0%)
88(46.5%)
382(43.5%)
NS
LVEF
62.11 ± 8.48
62.23 ± 8.95
62.09 ± 8.38
NS
LVdD, mm
50(45–56)
51(46–58)
50(45–56)
NS
LAD, mm
51.36 ± 12.04
51.36 ± 11.93
51.36 ± 12.07
NS
Emergency surgery
2(0.2%)
0(0.0%)
0(0.0%)
NS
Aspirin within 5 days
29(2.7%)
9(4.8%)
20(2.3%)
NS
Clopidogrel within 5 days
19(1.8%)
6(3.2%)
13(1.5%)
NS
BMI body mass index, BSA body surface area, NYHA New York Heart Association, MI myocardial infarction, MR mitral valve regurgitation, LVEF left ventricular ejection fraction, LVdD left ventricular diastolic diameter, LAD left atrial diameter, NS not significant

Patient characterize, PPM and valve prosthesis size

We analyzed the association among age, weight, height, BSA and valve size (Fig. 2). Krusal-Wallis analysis showed that weight, height and BSA are significantly associated with valve size (P < 0.01). In summary, larger mitral bioprosthetic valves were implanted in the taller and more obese patients.
Also, the PPM rate of each size of the prostheses was analyzed (Fig. 3). The results showed that the PPM rate of mechanical valve prostheses was considerably lower compared with bioprostheses (10.6% vs 48.5%, respectively, P < 0.001). As for the mechanical prostheses, there were no significant differences regarding the PPM occurrence of each valve size, whereas, the PPM rate of the 25 mm bioprosthesis was higher than that of the 27 mm and 29 mm bioprostheses (P < 0.01).
On the other hand, the PPM rate also differed among different brands of prostheses. As for mechanical prostheses, according to our data, PPM rate was highest (55.8%, 86/154) in patients underwent MVR with St. Jude Master Mechanical prostheses. And PPM rate was considerably low regarding CarboMedics mechanical prosthesis (0.9%, 6/679) and ATS open pivot mechanical prostheses (0.0%, 0/33). As for bioprosthesis, our results showed that PPM rate was high in patients using Medtronic Mosaic porcine bioprosthesis (80.0%, 4/5) or St. Jude Bicor bioprosthesis (82.2%, 37/45), whereas patients underwent MVR with Carpentier-Edwards Perimount bioprosthesis (17.7%, 5/38) and Medtronic Hancock II (45.4%, 50/110) showed lower rate of PPM.

Operative data

As shown in Table 3, there were no significant differences between PPM and non-PPM patients regarding cardiopulmonary bypass (CPB) time. However, we found that there is an average five-minute cross-clamp time reduction in the PPM group.
Table 3
Intraoperative data
 
total
PPM group
n = 189
non-PPM group
n = 878
P value
First time surgery
1013(94.9%)
181(95.8%)
832(94.7%)
NS
CPB time (min)
83(70–92)
83(70–89)
83(70–93)
NS
Cross-clamp time (min)
50(41–62)
45(40–55)
50(41–63)
< 0.001
Bioprosthesis
199(18.7%)
96(50.8%)
103(11.7%)
< 0.001
Combined procedure
 Tricuspid valve plasty
277(26.0%)
38(20.1%)
239(27.2%)
NS
 CABG
28(2.6%)
11(5.8%)
17(1.9%)
0.005
 AFRA or Maze surgery
106(9.9%)
30(15.9%)
76(8.7%)
0.005
 Others
139(13.0%)
30(15.9%)
109(12.4%)
NS
CPB cardiopulmonary bypass, CABG coronary artery bypass grafting surgery, AFRA atrial fibrillation radio frequency surgery, NS not significant
Not surprisingly, remarkably more patients with a PPM were implanted with a bioprosthetic mitral valve. And as for patients who received a bioprosthesis, the prevalence of mitral stenosis was higher for mismatch patients (58.3% vs 41.7%, P = 0.019), whereas patients of mechanical prostheses did not differ in the prevalence of mitral stenosis, whether PPM or not (77.4% vs 79.4%, P > 0.05).
As for combined procedures, there were more combined coronary artery bypass grafting (CABG) and surgical ablation for atrial fibrillation in the PPM group.

Factors affecting PPM

According to a multivariate binary logistic regression analysis including all preoperative and intraoperative variables, higher age (P = 0.011), larger BSA (P < 0.001), smaller left ventricular diastolic diameter (LVDd) (P < 0.001) and bioprosthesis (P < 0.001) were factors affecting mitral PPM (Table 4).
Table 4
Logistic regression analysis for prosthesis-patient mismatch
Factors
mean or %
OR
95% CI
P value
Age
54
1.029
1.006–1.051
0.011
BSA (m2)
1.57
152.111
45.261–511.208
< 0.001
LVDd (mm)
51.26
0.964
0.944–0.984
< 0.001
bioprosthesis
18.7%
7.539
4.632–12.273
< 0.001
OR odds ratio, CI confidence interval, BSA body surface area, LVDd left ventricular diastolic diameter

Postoperative outcomes and factors affecting postoperative mortality

There were no obvious differences between the two groups regarding early post-operative complications including blood transfusion, ventilation time, reintubation, intensive care unit (ICU) time, postop stroke, postop atrial fibrillation and short-term mortality. Also, there were no other reoperation for valve-rated complications including PPM or other cardiac disease during hospital-stay except that two patients underwent emergency percutaneous coronary intervention for acute myocardium ischemia. Interestingly, we found that there was a small increase in hospitalization expense as well as a slightly prolonged hospital stay for the PPM patients (Table 5).
Table 5
Postoperative outcomes
 
total
PPM group
non-PPM group
P
Perioperative transfusion
269(25.2%)
47(24.9%)
222(25.3%)
NS
Ventilation time (hr)
21(20–23)
21(20–23)
21(20–23)
NS
Reintubation
3(0.3%)
0(0.0%)
3(0.3%)
NS
Duration of first time ICU
72(72–96)
72(72–96)
72(72–96)
NS
Reentering ICU
2(0.2%)
2(1.1%)
0(0.0%)
NS
Chest tube output (ml)
545.88 ± 365.82
555.15 ± 295.51
543.87 ± 379.47
NS
Reoperation for bleeding
18(1.7%)
1(0.5%)
17(1.9%)
NS
Sternal wound infection
3(0.3%)
0(0.0%)
3(0.3%)
NS
Cerebral infarction
5(0.5%)
0(0.0%)
5(0.6%)
NS
Postoperative stroke
1(0.1%)
0(0.0%)
1(0.1%)
NS
Newly onset AF
3(0.3%)
0(0.0%)
3(0.3%)
NS
Mortality within 30 days
9(0.8%)
2(1.1%)
7(0.8%)
NS
Hospitalization expense (USD)
13,726
(11632–16,030)
14,446
(12538–17,010)
13,628
(11509–15,775)
0.032
Length of stay (d)
14(12–18)
15(13–19)
14(12–18)
0.011
ICU intensive care unit, AF atrial fibrillation, NS not significant
Altogether there were nine patients died within 30 days after surgery. Among them, five patients died due to malignant arrhythmia or cardiac arrest, two patient died of sever systematic infection, one patient died of uncontrollable bleeding and one patient died because of stroke. Among these short-term deaths, 2 patients underwent MVR with Hancock II bioprostheses, whereas 7 patients were replaced with CarboMedics mechanical prostheses.
Logistic regression analysis showed that smoking history and preoperative low left ventricular ejection fraction (LVEF) were independent factors predicting post-operative short-term all-cause mortality. However, PPM was not a risk factor for short-term mortality (Table 6).
Table 6
Logistic regression model for postoperative 30-day global mortaliy
Factors
mean or %
Odds ratio
95% CI
P value
smoking history
11.5%
3.199
0.729–14.041
0.004
preoperative LVEF
62.11
0.955
0.887–1.029
0.001
PPM
17.7%
1.138
0.226–5.743
0.654
CI confidence interval, LVEF left ventricular ejection fraction

Mid-term follow-up

During mid-term follow-up, two patients underwent re-operative for stuck of the mechanical prostheses (both CarboMedics Mechanical prostheses). Both of the patients had an irregular medication history of Warfarin.
Mid-term deaths occurred in eight patients who all underwent MVR with a mechanical prosthesis, adding to the previously mentioned nine short-term deaths. Cumulative mid-term overall survival is 0.986 for both PPM and non-PPM patients (Fig. 4), and there were no significant difference regarding mid-term mortality for the two groups (SE 0.037, Log-rank p = 0.847). All the later occurring eight deaths were coagulation-related death. The overall mortality at 30 months was approximately 1.6% (Table 7). During follow-up, about 9.2% of the patients presented compromised cardiac functions with New York Heart Association (NYHA) functional classes III to IV. However, there were no significant differences between the PPM and non-PPM patients.
Table 7
Mid-term follow-up information
 
Total
PPM group
non-PPM group
P value
Follow-up time (months)
31(23–35)
32(24–35)
31(23–33)
P = 0.362
NYHA functional class (III-IV)
9.2%
9.0%
9.6%
P = 0.902
Mortality
17(1.6%)
3(1.6%)
14(1.6%)
P = 0.994
NYHA New York Heart Association

Discussion

PPM occurrence and its risk factors

Although highly variable, PPM rates for mitral position in most of the literature ranged from 20 to 70% [1116]. However, the incidence of PPM after MVR in our single-centered cohort was 17.7% and only 1.2% of the cases met the criteria for severe PPM.
We performed logistic regression analysis and found that larger BSA, higher age, implantation of bioprosthesis and smaller LVDd were risk factors for PPM. Besides BSA, EOA was the only variable defining the EOAi which determined the occurrence of PPM. Bioprosthesis possessed smaller EOA compared with mechanical prosthesis of the same valve size, leading to an increased rate of PPM. Also, bioprostheses were more prone to late degenerative calcification, which may further decrease its EOA. Thus, the more common use of bioprosthesis for degenerative mitral regurgitation might explain the lower prevalence of mitral stenosis of the PPM group in the preoperative data. As for LVDd, it was an indirect reflection of the mitral annulus diameter, which was another decisive factor in choosing prosthesis size, affecting the EOA of the prosthesis implanted. Higher age was then associated with more bioprosthesis implantation, thus leading to the increase in PPM occurrence. Hence, the difference of patient baseline characteristics between the PPM and non-PPM patients in hypertension and coronary heart disease could be explained by the higher age and obesity of the PPM patients.
In the Asian population, especially the eastern Chinese population, mitral stenosis and small size mitral prosthesis implantation might generally be considered to occur more frequently than in Western populations due to rheumatic causes associated with a small annulus. However, due to rheumatic etiology, the episode age of these patients was considerably younger than patients with valvular degeneration as predominant causes in Western countries. Thus, a larger ratio of patients of this population were implanted with mechanical mitral prostheses which possessed larger EOA than bioprosthesis. Also, patients of this population had a smaller body surface area than those in Western populations, leading to a further reduction in PPM occurrence. The aforementioned factors altogether help explain the low PPM rate in our study population.

PPM and patient outcomes

Since its first description in 1978 by Rahimtoola [1], PPM after MVR has been suggested to potentially correlate with poor clinical outcomes including late tricuspid regurgitation and persistent pulmonary hypertension [11, 14, 17], similar to the outcomes of residual mitral stenosis. However, there were also reports suggesting that PPM did not affect survival after MVR [18, 19].
In our analysis, no impact of PPM on patient mortality was detected either in the postoperative short-term period or in the mid-term follow-up. Our findings are consistent with several large sample multi-centered analyses [15, 19]. Our results showed that smoking history and low preoperative LVEF were associated with higher short-term mortality, but not PPM.
Interestingly, our study showed that cross-clamp times were shorter in patients with PPM, with an average shortened time of 5 min. This might be explained because less time was spent suturing the mitral prosthesis due to the smaller mitral annulus diameter of the PPM patients. The longer hospitalization time of the PPM patients shown in the results might be due to the their higher average age and because their recovery time might be longer than in younger patients. Also, the elevated hospitalization expense could be explained by higher price of the bioprosthesis which was more common in the PPM group.

Clinical implication for east Asian population

Currently, the most precise parameter in characterizing PPM is the EOAi [20], which is defined as the EOA of the prosthesis divided by the patient’s BSA. EOAi is in fact the only parameter found to consistently correlate with the postoperative gradient; therefore it is the most widely used. In Western countries, the predominant cause of mitral valve disease is degenerative mitral valve regurgitation. For this population, patients with mitral valve diseases usually have a larger left ventricle volume (left ventricular diastolic diameter) than the eastern Asian population; therefore, implantation of a large size prosthesis to avoid PPM will not have an obvious effect on left ventricular function. Hence, the parameter of EOAi has high feasibility in characterizing PPM for Western populations.
However, in a rheumatic population such as the eastern Asian population, the incidence of mitral valve stenosis is much higher than mitral valve regurgitation [11]. A larger proportion of this population has small left ventricle size, with part of the patients’ LVDd even smaller than the mitral annulus diameter. For these patients, implantation of a large sized prosthesis might compromise the effective cardiac muscular contraction of the left ventricle, causing left ventricular systolic dysfunction or, even worse, increase the risk of left ventricular rupture.
In our opinion, whether the current PPM standard is suitable for a rheumatic population such as the eastern Chinese is worth further exploration. Our results showed that there were no differences regarding the PPM occurrence of each valve size in the mechanical prosthesis. In our future study, we hope that we can explore a more precise parameter in predicting PPM then the current one, hence providing a more accurate prediction of patient outcomes for patients who underwent MVR in our population.

Limitations of the study

There are limitations of the study which must be recognized. First, this is a retrospective analysis, and, as an inherent disadvantage, the recorded differences in patient outcomes could have originated from smaller recorded or unrecorded differences between PPM and non-PPM patients. Second, in our study, EOA was predicted by reference tables, which might not reflect the actual in vivo values of the EOAi. Moreover, this is a single-centered short/mid-term study, and sample size and follow-up time were limited. Therefore, a randomized prospective multi-centered clinical trial with a long follow-up time is needed to study the effect of mitral PPM on longer-term patient outcomes.

Conclusions

Our results demonstrated that higher age, bioprosthesis, larger BSA and smaller left ventricle were associated with mitral PPM. However, PPM was not associated with poorer early outcomes after MVR surgery. In eastern China, the prevalence of mitral valve stenosis is high; therefore, whether the standard PPM criteria are suitable for patients of this district needs to be further verified.

Acknowledgements

The authors would like to thank the anesthetists, intensivists, heart surgeons, nursing staff, perfusionists and the laboratory department at the First Affiliated Hospital, Zhejiang University for the collection and management of the data presented in this report.

Availability of data and materials

The datasets during and/or analysed during the current study available from the corresponding author on reasonable request.
written informed consent waived by the Hospital Review Board.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation. 1978;58(1):20–4.CrossRef Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation. 1978;58(1):20–4.CrossRef
2.
Zurück zum Zitat Rahimtoola SH, Murphy E. Valve prosthesis--patient mismatch. A long-term sequela. Br Heart J. 1981;45(3):331–5.CrossRef Rahimtoola SH, Murphy E. Valve prosthesis--patient mismatch. A long-term sequela. Br Heart J. 1981;45(3):331–5.CrossRef
3.
Zurück zum Zitat Hong S, Yi GJ, Youn YN, Lee S, Yoo KJ, Chang BC. Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: a prospective observational study. J Thorac Cardiov Sur. 2013;146(5):1098–104.CrossRef Hong S, Yi GJ, Youn YN, Lee S, Yoo KJ, Chang BC. Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: a prospective observational study. J Thorac Cardiov Sur. 2013;146(5):1098–104.CrossRef
4.
Zurück zum Zitat Fuster RG, Montero Argudo JA, Albarova OG, et al. Patient-prosthesis mismatch in aortic valve replacement: really tolerable? Eur J Cardiothorac Surg. 2005;27(3):441–9 discussion 9.CrossRef Fuster RG, Montero Argudo JA, Albarova OG, et al. Patient-prosthesis mismatch in aortic valve replacement: really tolerable? Eur J Cardiothorac Surg. 2005;27(3):441–9 discussion 9.CrossRef
5.
Zurück zum Zitat Guo L, Zheng J, Chen L, et al. Impact of prosthesis-patient mismatch on short-term outcomes after aortic valve replacement: a retrospective analysis in East China. J Cardiothorac Surg. 2017;12(1):42.CrossRef Guo L, Zheng J, Chen L, et al. Impact of prosthesis-patient mismatch on short-term outcomes after aortic valve replacement: a retrospective analysis in East China. J Cardiothorac Surg. 2017;12(1):42.CrossRef
6.
Zurück zum Zitat Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of mitral prosthetic valvular areas calculated by Doppler echocardiography. Am J Cardiol. 1990;65(22):1443–8.CrossRef Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of mitral prosthetic valvular areas calculated by Doppler echocardiography. Am J Cardiol. 1990;65(22):1443–8.CrossRef
7.
Zurück zum Zitat Dumesnil JG, Yoganathan AP. Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients. Eur J Cardiothorac Surg. 1992;6(Suppl 1):S34–7 discussion S8.CrossRef Dumesnil JG, Yoganathan AP. Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients. Eur J Cardiothorac Surg. 1992;6(Suppl 1):S34–7 discussion S8.CrossRef
8.
Zurück zum Zitat Leavitt JI, Coats MH, Falk RH. Effects of exercise on transmitral gradient and pulmonary artery pressure in patients with mitral stenosis or a prosthetic mitral valve: a Doppler echocardiographic study. J Am Coll Cardiol. 1991;17(7):1520–6.CrossRef Leavitt JI, Coats MH, Falk RH. Effects of exercise on transmitral gradient and pulmonary artery pressure in patients with mitral stenosis or a prosthetic mitral valve: a Doppler echocardiographic study. J Am Coll Cardiol. 1991;17(7):1520–6.CrossRef
9.
Zurück zum Zitat Rosenhek R, Binder T, Maurer G, Baumgartner H. Normal values for Doppler echocardiographic assessment of heart valve prostheses. J Am Soc Echocardiogr. 2003;16(11):1116–27.CrossRef Rosenhek R, Binder T, Maurer G, Baumgartner H. Normal values for Doppler echocardiographic assessment of heart valve prostheses. J Am Soc Echocardiogr. 2003;16(11):1116–27.CrossRef
10.
Zurück zum Zitat Dumesnil JG, Pibarot P. Prosthesis-patient mismatch: an update. Curr Cardiol Rep. 2011;13(3):250–7.CrossRef Dumesnil JG, Pibarot P. Prosthesis-patient mismatch: an update. Curr Cardiol Rep. 2011;13(3):250–7.CrossRef
11.
Zurück zum Zitat Lee SH, Chang BC, Youn YN, Joo HC, Yoo KJ, Lee S. Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: does mitral position prosthesis-patient mismatch really exist? J Cardiothorac Surg. 2017;12(1):88.CrossRef Lee SH, Chang BC, Youn YN, Joo HC, Yoo KJ, Lee S. Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: does mitral position prosthesis-patient mismatch really exist? J Cardiothorac Surg. 2017;12(1):88.CrossRef
12.
Zurück zum Zitat Lam BK, Chan V, Hendry P, et al. The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement. J Thorac Cardiovasc Surg. 2007;133(6):1464–73.CrossRef Lam BK, Chan V, Hendry P, et al. The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement. J Thorac Cardiovasc Surg. 2007;133(6):1464–73.CrossRef
13.
Zurück zum Zitat Magne J, Mathieu P, Dumesnil JG, et al. Impact of prosthesis-patient mismatch on survival after mitral valve replacement. Circulation. 2007;115(11):1417–25.CrossRef Magne J, Mathieu P, Dumesnil JG, et al. Impact of prosthesis-patient mismatch on survival after mitral valve replacement. Circulation. 2007;115(11):1417–25.CrossRef
14.
Zurück zum Zitat Li M, Dumesnil JG, Mathieu P, Pibarot P. Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement. J Am Coll Cardiol. 2005;45(7):1034–40.CrossRef Li M, Dumesnil JG, Mathieu P, Pibarot P. Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement. J Am Coll Cardiol. 2005;45(7):1034–40.CrossRef
15.
Zurück zum Zitat Jamieson WR, Germann E, Ye J, et al. Effect of prosthesis-patient mismatch on long-term survival with mitral valve replacement: assessment to 15 years. Ann Thorac Surg. 2009;87(4):1135–41 discussion 42.CrossRef Jamieson WR, Germann E, Ye J, et al. Effect of prosthesis-patient mismatch on long-term survival with mitral valve replacement: assessment to 15 years. Ann Thorac Surg. 2009;87(4):1135–41 discussion 42.CrossRef
16.
Zurück zum Zitat Aziz A, Lawton JS, Maniar HS, Pasque MK, Damiano RJ Jr, Moon MR. Factors affecting survival after mitral valve replacement in patients with prosthesis-patient mismatch. Ann Thorac Surg. 2010;90(4):1202–10 discussion 10-1.CrossRef Aziz A, Lawton JS, Maniar HS, Pasque MK, Damiano RJ Jr, Moon MR. Factors affecting survival after mitral valve replacement in patients with prosthesis-patient mismatch. Ann Thorac Surg. 2010;90(4):1202–10 discussion 10-1.CrossRef
17.
Zurück zum Zitat Angeloni E, Melina G, Pibarot P, et al. Impact of prosthesis-patient mismatch on the regression of secondary mitral regurgitation after isolated aortic valve replacement with a bioprosthetic valve in patients with severe aortic stenosis. Circ Cardiovasc Imaging. 2012;5(1):36–42.CrossRef Angeloni E, Melina G, Pibarot P, et al. Impact of prosthesis-patient mismatch on the regression of secondary mitral regurgitation after isolated aortic valve replacement with a bioprosthetic valve in patients with severe aortic stenosis. Circ Cardiovasc Imaging. 2012;5(1):36–42.CrossRef
18.
Zurück zum Zitat Sakamoto H, Watanabe Y. Does patient-prosthesis mismatch affect long-term results after mitral valve replacement? Ann Thorac Cardiovasc Surg. 2010;16(3):163–7.PubMed Sakamoto H, Watanabe Y. Does patient-prosthesis mismatch affect long-term results after mitral valve replacement? Ann Thorac Cardiovasc Surg. 2010;16(3):163–7.PubMed
19.
Zurück zum Zitat Shi WY, Yap CH, Hayward PA, et al. Impact of prosthesis--patient mismatch after mitral valve replacement: a multicentre analysis of early outcomes and mid-term survival. Heart. 2011;97(13):1074–81.CrossRef Shi WY, Yap CH, Hayward PA, et al. Impact of prosthesis--patient mismatch after mitral valve replacement: a multicentre analysis of early outcomes and mid-term survival. Heart. 2011;97(13):1074–81.CrossRef
20.
Zurück zum Zitat Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart. 2006;92(8):1022–9.CrossRef Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart. 2006;92(8):1022–9.CrossRef
21.
Zurück zum Zitat Bitar JN, Lechin ME, Salazar G, Zoghbi WA. Doppler echocardiographic assessment with the continuity equation of St. Jude Medical mechanical prostheses in the mitral valve position. Am J Cardiol. 1995;76(4):287–93.CrossRef Bitar JN, Lechin ME, Salazar G, Zoghbi WA. Doppler echocardiographic assessment with the continuity equation of St. Jude Medical mechanical prostheses in the mitral valve position. Am J Cardiol. 1995;76(4):287–93.CrossRef
22.
Zurück zum Zitat Cohn LH, Edmunds LH. Cardiac surgery in the adult. 3rd ed. New York: McGraw-Hill Medical; 2008. Cohn LH, Edmunds LH. Cardiac surgery in the adult. 3rd ed. New York: McGraw-Hill Medical; 2008.
23.
Zurück zum Zitat Borracci RA, Rubio M, Sestito ML, Ingino CA, Barrero C, Rapallo CA. Incidence of prosthesis-patient mismatch in patients receiving mitral Biocor(R) porcine prosthetic valves. Cardiol J. 2016;23(2):178–83.CrossRef Borracci RA, Rubio M, Sestito ML, Ingino CA, Barrero C, Rapallo CA. Incidence of prosthesis-patient mismatch in patients receiving mitral Biocor(R) porcine prosthetic valves. Cardiol J. 2016;23(2):178–83.CrossRef
Metadaten
Titel
Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China
verfasst von
Armah M Akuffu
Haige Zhao
Junnan Zheng
Yiming Ni
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
Journal of Cardiothoracic Surgery / Ausgabe 1/2018
Elektronische ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-018-0788-4

Weitere Artikel der Ausgabe 1/2018

Journal of Cardiothoracic Surgery 1/2018 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.