Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 5/2019

19.01.2019 | Original Paper

Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 5/2019

Einloggen, um Zugang zu erhalten

Abstract

Prosthesis-patient mismatch (PPM) occurs when the effective orifice area of the prosthesis is too small in relation to the patient's body surface area. There are few data available on the frequency and prognostic impact of PPM after transcatheter aortic valve implantation (TAVI). Our aim was to determine the prevalence of PPM and to investigate its association with medium-term clinical course of patients undergoing TAVI. We included 185 patients undergoing TAVI (79 ± 5 years, 49% male, 98% CoreValve) between April-2008 and December-2014. The effective orifice area (EOA) was determined by transthoracic echocardiography prior and after the procedure. We defined PPM as indexed EOA ≤ 0.85 cm2/m2 (severe PPM if ≤ 0.65 cm2/m2). All cause death, stroke and hospitalization for heart failure were considered as major clinical events. 45 patients (24%) showed PPM (severe 11 patients, 6%). PPM was associated with a higher EuroSCORE (OR 1.06, IC 95% 1.01–1.12, p = 0.03), body surface area ≥ 1.72 m2 (OR 3.58, IC 95% 1.30–9.87, p = 0.01) and small aortic annulus (OR 0.73, IC 95% 0.55–0.92, p = 0.03); and severe PPM with small prostheses size (OR 17.79, IC 95% 1.87–169.78, p = 0.012). The mean event-free survival was 34 ± 26 months. Patients with severe PPM showed lower rates of event free survival than the rest of the series (52% vs. 84%, p = 0.04) at 34 months follow up. In our series, PPM was present in a quarter of the patients after TAVI. Higher EuroSCORE, smaller prosthesis size, larger body surface area and smaller aortic annulus diameter were associated with PPM. Severe PPM was an independent factor associated with major events at medium-term follow up.
Literatur
1.
Zurück zum Zitat Grube E, Schuler G, Buellesfeld L, Gerckens U, Linke A, Zickmann B et al (2007) Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding Core-Valve Prosthesis. J Am Coll Cardiol 50:69–76CrossRefPubMed Grube E, Schuler G, Buellesfeld L, Gerckens U, Linke A, Zickmann B et al (2007) Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding Core-Valve Prosthesis. J Am Coll Cardiol 50:69–76CrossRefPubMed
2.
Zurück zum Zitat Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G et al (2011) Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients. Circulation 123:299–308CrossRefPubMed Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G et al (2011) Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients. Circulation 123:299–308CrossRefPubMed
3.
Zurück zum Zitat Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607CrossRefPubMed Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607CrossRefPubMed
4.
Zurück zum Zitat Smith C, Leon M, Mack M, Miller D, Moses J, Svensson L et al (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364(23):2187–2198CrossRefPubMed Smith C, Leon M, Mack M, Miller D, Moses J, Svensson L et al (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364(23):2187–2198CrossRefPubMed
5.
Zurück zum Zitat Kodali S, Williams M, Smith S, Lars G, Webb JG, Makkar RR et al (2012) Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 366:1686–1695CrossRefPubMed Kodali S, Williams M, Smith S, Lars G, Webb JG, Makkar RR et al (2012) Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 366:1686–1695CrossRefPubMed
6.
Zurück zum Zitat Hahn R, Pibarot P, Stewart W, Weissman NJ, Gopalakrishnan D, Keane MG et al (2013) Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis a longitudinal study of echocardiography parameters in Cohort A of the PARTNER trial (placement of aortic transcatheter valves). JACC 61(25):2514–21CrossRefPubMed Hahn R, Pibarot P, Stewart W, Weissman NJ, Gopalakrishnan D, Keane MG et al (2013) Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis a longitudinal study of echocardiography parameters in Cohort A of the PARTNER trial (placement of aortic transcatheter valves). JACC 61(25):2514–21CrossRefPubMed
7.
Zurück zum Zitat Holmes DR, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR et al (2012) 2012 ACCF / AATS / SCAI / STS expert consensus document on transcatheter aortic valve replacement. Cathet Cardiovasc Interv 79:1023–1082CrossRef Holmes DR, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR et al (2012) 2012 ACCF / AATS / SCAI / STS expert consensus document on transcatheter aortic valve replacement. Cathet Cardiovasc Interv 79:1023–1082CrossRef
8.
Zurück zum Zitat Avanzas P, Pascual I, Muñoz-García AJ, Segura J, Alonso-briales JH, Suárez de Lezo J et al (2017) Seguimiento a largo plazo de pacientes con estenosis aórtica grave tratados con prótesis autoexpandible. Rev Esp Cardiol 70(4):247–253CrossRefPubMed Avanzas P, Pascual I, Muñoz-García AJ, Segura J, Alonso-briales JH, Suárez de Lezo J et al (2017) Seguimiento a largo plazo de pacientes con estenosis aórtica grave tratados con prótesis autoexpandible. Rev Esp Cardiol 70(4):247–253CrossRefPubMed
9.
Zurück zum Zitat Lancellotti P, Pibarot P, Chambers J et al (2016) Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging 17:589–590CrossRefPubMed Lancellotti P, Pibarot P, Chambers J et al (2016) Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging 17:589–590CrossRefPubMed
10.
Zurück zum Zitat Kappetein AP, Head SJ, Genereux P, Piazza N, Van Mieghem NM, Blackstone EH et al (2012) Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. Eur J Cardiothorac Surg 42:S45–S60CrossRefPubMed Kappetein AP, Head SJ, Genereux P, Piazza N, Van Mieghem NM, Blackstone EH et al (2012) Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. Eur J Cardiothorac Surg 42:S45–S60CrossRefPubMed
11.
Zurück zum Zitat Dumesnil J, Pibarot P (2011) Prosthesis-patient mismatch: an update. Curr Cardiol Rep 13(3):250–257CrossRefPubMed Dumesnil J, Pibarot P (2011) Prosthesis-patient mismatch: an update. Curr Cardiol Rep 13(3):250–257CrossRefPubMed
12.
Zurück zum Zitat Takagi H, Yamamoto H, Iwata K, Goto SN, Umemoto T (2012) A meta-analysis of effects of prosthesis-patient mismatch after aortic valve replacement on late mortality. Int J Cardiol 159(2):150–154CrossRefPubMed Takagi H, Yamamoto H, Iwata K, Goto SN, Umemoto T (2012) A meta-analysis of effects of prosthesis-patient mismatch after aortic valve replacement on late mortality. Int J Cardiol 159(2):150–154CrossRefPubMed
13.
Zurück zum Zitat Chen J, Lin Y, Kang B, Wang Z (2014) Indexed effective orifice area is a significant predictor of higher mid- and long-term mortality rates following aortic valve replacement in patients with prosthesis-patient mismatch. Eur J Cardio-thoracic Surg 45(2):234–240CrossRef Chen J, Lin Y, Kang B, Wang Z (2014) Indexed effective orifice area is a significant predictor of higher mid- and long-term mortality rates following aortic valve replacement in patients with prosthesis-patient mismatch. Eur J Cardio-thoracic Surg 45(2):234–240CrossRef
14.
Zurück zum Zitat Takagi H, Umemoto T (2016) Prosthesis-patient mismatch after transcatheter aortic valve implantation. Ann Thorac Surg 101(3):872–880CrossRefPubMed Takagi H, Umemoto T (2016) Prosthesis-patient mismatch after transcatheter aortic valve implantation. Ann Thorac Surg 101(3):872–880CrossRefPubMed
15.
Zurück zum Zitat Pibarot P, Weissman NJ, Stewart WJ, Hahn RT, Lindman BR, McAndrew T et al (2014) Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort-a analysis. J Am Coll Cardiol 64(13):1323–1334CrossRefPubMedPubMedCentral Pibarot P, Weissman NJ, Stewart WJ, Hahn RT, Lindman BR, McAndrew T et al (2014) Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort-a analysis. J Am Coll Cardiol 64(13):1323–1334CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Muñoz-García AJ, Muñoz-García M, Carrasco-Chinchilla F, Molina-Mora MJ, Rodríguez-Bailón I, Domínguez-Franco AJ et al (2013) Incidence and clinical outcome of prosthesis-patient mismatch after transcatheter aortic valve implantation with the CoreValve prosthesis. Int J Cardiol 167(3):1074–1076CrossRefPubMed Muñoz-García AJ, Muñoz-García M, Carrasco-Chinchilla F, Molina-Mora MJ, Rodríguez-Bailón I, Domínguez-Franco AJ et al (2013) Incidence and clinical outcome of prosthesis-patient mismatch after transcatheter aortic valve implantation with the CoreValve prosthesis. Int J Cardiol 167(3):1074–1076CrossRefPubMed
17.
Zurück zum Zitat Zorn GL, Little SH, Tadros P, Deeb GM, Gleason TG, Heiser J et al (2016) Prosthesis-patient mismatch in high-risk patients with severe aortic stenosis: a randomized trial of a self-expanding prosthesis. J Thorac Cardiovasc Surg 151(4):1014–1023CrossRefPubMed Zorn GL, Little SH, Tadros P, Deeb GM, Gleason TG, Heiser J et al (2016) Prosthesis-patient mismatch in high-risk patients with severe aortic stenosis: a randomized trial of a self-expanding prosthesis. J Thorac Cardiovasc Surg 151(4):1014–1023CrossRefPubMed
18.
Zurück zum Zitat da Silva C, Sahlen A, Winter R, Bäck M, Rück A, Settergren M et al (2014) Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography. Int J Cardiovasc Imaging 30:1549–1557CrossRefPubMed da Silva C, Sahlen A, Winter R, Bäck M, Rück A, Settergren M et al (2014) Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography. Int J Cardiovasc Imaging 30:1549–1557CrossRefPubMed
19.
Zurück zum Zitat Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA et al (2009) Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound. A report from the American Society of Echocardiography’s guidelines and standards committee and the task force on prosthetic valves, developed in conjunction. J Am Soc Echocardiogr 22(9):975–1014CrossRefPubMed Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA et al (2009) Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound. A report from the American Society of Echocardiography’s guidelines and standards committee and the task force on prosthetic valves, developed in conjunction. J Am Soc Echocardiogr 22(9):975–1014CrossRefPubMed
20.
Zurück zum Zitat Quiñones M, Douglas P, Foster E, Gorcsan J, Lewis J, Pearlman A et al (2003) ACC/AHA clinical competence statement on echocardiography: a report of the American College of Cardiology/American Heart Association/American College of Physicians–American Society of Internal Medicine. Task force on clinical competence. JACC 41:687–708CrossRefPubMed Quiñones M, Douglas P, Foster E, Gorcsan J, Lewis J, Pearlman A et al (2003) ACC/AHA clinical competence statement on echocardiography: a report of the American College of Cardiology/American Heart Association/American College of Physicians–American Society of Internal Medicine. Task force on clinical competence. JACC 41:687–708CrossRefPubMed
21.
Zurück zum Zitat Evangelista A, María Á, Gómez A, Durán RM, Yagüela MM, María J et al (2000) Guías de práctica clínica de la Sociedad Española de Cardiología en ecocardiografía. Rev Esp Cardiol 53(5):663–683CrossRef Evangelista A, María Á, Gómez A, Durán RM, Yagüela MM, María J et al (2000) Guías de práctica clínica de la Sociedad Española de Cardiología en ecocardiografía. Rev Esp Cardiol 53(5):663–683CrossRef
22.
Zurück zum Zitat Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA et al (2006) Recommendations for chamber quantification. Eur J Echocardiogr 7(2):79–108CrossRefPubMed Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA et al (2006) Recommendations for chamber quantification. Eur J Echocardiogr 7(2):79–108CrossRefPubMed
23.
Zurück zum Zitat Dubois D, Dubois E (1916) A formula to estimate the approximate surface area of height and weight be known. Arch Intern Med 17:863–871CrossRef Dubois D, Dubois E (1916) A formula to estimate the approximate surface area of height and weight be known. Arch Intern Med 17:863–871CrossRef
24.
Zurück zum Zitat Mesa D, Suárez de Lezo J, Alvarez-Ossorio M, Ruiz Ortiz M, Delgado Ortega M, León del Pino M et al (2011) Measurement of aortic valve annulus using different cardiac imaging techniques in transcatheter aortic valve implantation: agreement with finally implanted prosthesis size. Echocardiography 28:388–396CrossRef Mesa D, Suárez de Lezo J, Alvarez-Ossorio M, Ruiz Ortiz M, Delgado Ortega M, León del Pino M et al (2011) Measurement of aortic valve annulus using different cardiac imaging techniques in transcatheter aortic valve implantation: agreement with finally implanted prosthesis size. Echocardiography 28:388–396CrossRef
25.
Zurück zum Zitat León C, Suárez de Lezo J, Mesa D, Pan M, Ruiz M, Delgado M et al (2011) Early development of leaks in the CoreValve percutaneous aortic valve prosthesis: echocardiographic assessment. Rev Esp Cardiol 64:67–70CrossRefPubMed León C, Suárez de Lezo J, Mesa D, Pan M, Ruiz M, Delgado M et al (2011) Early development of leaks in the CoreValve percutaneous aortic valve prosthesis: echocardiographic assessment. Rev Esp Cardiol 64:67–70CrossRefPubMed
26.
Zurück zum Zitat Cejudo Díaz del Campo L, Mesa Rubio D, Ruiz Ortiz M, Delgado Ortega M, Pan M, Ojeda Pineda S et al (2012) Usefulness of transesophageal echocardiography during implantation of the CoreValve percutaneous aortic prosthesis: Influence of the learning curve. Catheter Cardiovasc Interv 80:964–971CrossRef Cejudo Díaz del Campo L, Mesa Rubio D, Ruiz Ortiz M, Delgado Ortega M, Pan M, Ojeda Pineda S et al (2012) Usefulness of transesophageal echocardiography during implantation of the CoreValve percutaneous aortic prosthesis: Influence of the learning curve. Catheter Cardiovasc Interv 80:964–971CrossRef
27.
Zurück zum Zitat Avanzas P, Munoz-Garcia A, Segura J, Pan M, Alonso-Briales J, Lozano I et al (2010) Percutaneous Implantation of the CoreValve(registered trademark) self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain. Rev Esp Cardiol 63(2):141–148CrossRefPubMed Avanzas P, Munoz-Garcia A, Segura J, Pan M, Alonso-Briales J, Lozano I et al (2010) Percutaneous Implantation of the CoreValve(registered trademark) self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain. Rev Esp Cardiol 63(2):141–148CrossRefPubMed
28.
Zurück zum Zitat Rodés-cabau J, Pibarot P, Suri RM, Kodali S, Thourani VH, Szeto WY et al (2014) Impact of aortic annulus size on valve hemodynamics and clinical outcomes after transcatheter and surgical aortic valve replacement insights from the PARTNER trial. Circ Cardiovasc Interv 7:701–711CrossRefPubMed Rodés-cabau J, Pibarot P, Suri RM, Kodali S, Thourani VH, Szeto WY et al (2014) Impact of aortic annulus size on valve hemodynamics and clinical outcomes after transcatheter and surgical aortic valve replacement insights from the PARTNER trial. Circ Cardiovasc Interv 7:701–711CrossRefPubMed
29.
Zurück zum Zitat Pibarot P, Clavel M, Dahou A (2015) Patient and procedure selection for the prevention of prosthesis-patient mismatch following aortic valve replacement. EuroIntervention 11:106–109CrossRef Pibarot P, Clavel M, Dahou A (2015) Patient and procedure selection for the prevention of prosthesis-patient mismatch following aortic valve replacement. EuroIntervention 11:106–109CrossRef
30.
Zurück zum Zitat Lebera A, Eichingerc W, Rieberb J, Lieberc M, Schlegerc S, Ebersbergerb U et al (2013) MSCT guided sizing of the Edwards Sapien XT TAVI device: Impact of different degrees of oversizing on clinical outcome. Int J Cardiol 168(3):2658–2664CrossRef Lebera A, Eichingerc W, Rieberb J, Lieberc M, Schlegerc S, Ebersbergerb U et al (2013) MSCT guided sizing of the Edwards Sapien XT TAVI device: Impact of different degrees of oversizing on clinical outcome. Int J Cardiol 168(3):2658–2664CrossRef
31.
Zurück zum Zitat Samim M, Stella PR, Agostoni P, Kluin J, Ramjankhan F, Sieswerda G et al (2013) A prospective “oversizing” strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation. J Thorac Cardiovasc Surg 145(2):398–405CrossRefPubMed Samim M, Stella PR, Agostoni P, Kluin J, Ramjankhan F, Sieswerda G et al (2013) A prospective “oversizing” strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation. J Thorac Cardiovasc Surg 145(2):398–405CrossRefPubMed
32.
Zurück zum Zitat Dayan V, Soca G, Stanham R, Lorenzo A, Ferreiro A (2015) Is patient–prosthesis mismatch a predictor of survival or a surrogate marker of co-morbidities in cardiac surgery? Int J Cardiol 190:389–392CrossRefPubMed Dayan V, Soca G, Stanham R, Lorenzo A, Ferreiro A (2015) Is patient–prosthesis mismatch a predictor of survival or a surrogate marker of co-morbidities in cardiac surgery? Int J Cardiol 190:389–392CrossRefPubMed
33.
Zurück zum Zitat Tzikas A, Piazza N, Geleijnse ML, Van Mieghem N, Nuis RJ, Schultz C et al (2010) Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic corevalve system in patients with aortic stenosis. Am J Cardiol 106(2):255–260CrossRefPubMed Tzikas A, Piazza N, Geleijnse ML, Van Mieghem N, Nuis RJ, Schultz C et al (2010) Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic corevalve system in patients with aortic stenosis. Am J Cardiol 106(2):255–260CrossRefPubMed
34.
Zurück zum Zitat Nishimura R, Otto C, Bonow R, Mack M, Carabello B, McLeod C et al (2017) 2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association task force on clinical practice guidelines. Circulation 135(21):1–123 Nishimura R, Otto C, Bonow R, Mack M, Carabello B, McLeod C et al (2017) 2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association task force on clinical practice guidelines. Circulation 135(21):1–123
Metadaten
Titel
Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact
Publikationsdatum
19.01.2019
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 5/2019
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-01519-z

Weitere Artikel der Ausgabe 5/2019

The International Journal of Cardiovascular Imaging 5/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.