Skip to main content
Erschienen in: Pediatric Cardiology 4/2012

Open Access 01.04.2012 | Original Article

Psychological Functioning and Disease-Related Quality of Life in Pediatric Patients With an Implantable Cardioverter Defibrillator

verfasst von: H. M. Koopman, C. M. J. Vrijmoet-Wiersma, J. N. D. Langius, F. van den Heuvel, S. A. Clur, C. A. Blank, N. A. Blom, A. D. J. ten Harkel

Erschienen in: Pediatric Cardiology | Ausgabe 4/2012

Abstract

The objective of this multicenter study was to evaluate psychological functioning and disease-related quality of life (DRQoL) in pediatric patients with an implantable cardioverter defibrillator (ICD) in The Netherlands. Thirty patients were investigated; the mean age was 16.3 years, and the mean duration of implantation was 3.6 years. To assess psychological problems, three domains of the Symptom Checklist (SCL-90-R) were administered to the 25 patients >13 years old. DRQoL was assessed with a disease-specific pediatric questionnaire, the short-form 11-item Worries About (WA)ICDs Scale. Patients ≥13 years old scored significantly higher than the reference group on the domains of anxiety, depression, and sleeping problems of the SCL-90-R (T = 7.5, p < 0.001; T = 5.4, p < 0.001; and T = 7.8, p < 0.001, respectively). Patients who had received an (in)appropriate shock reported more depressive symptoms (T = 2.1, p < 0.03). Patients with >2 years implant duration (N = 19) or who had received an (in)appropriate shock (N = 13) showed lower DRQoL scores on the modified WAICD (T = 2.1, p < 0.04; T = 2.1, p < 0.5, respectively). Age at implantation or underlying disease did not influence psychological problems or DRQoL. Young ICD patients showed more anxiety, depression, and sleeping disorders. Worries were increased among patients with ICD shocks and in those who had their ICD implanted for >2 years. To determine psychological problems and help children to learn to cope with shocks, proper guidance and monitoring of young ICD patients are recommended.

Introduction

Treatment with an implantable cardioverter defibrillator (ICD) has significantly improved survival in patients with life-threatening arrhythmias. During the last two decades, ICD therapy has played an increasing role in the management of a diverse population of cardiac patients, such as ischemic and nonischemic cardiomyopathies and inherited proarrhythmic syndromes [4, 11]. Although ICD implantations in children are only 1% of those in adults, outcome data of ICD therapy in children are comparable with adult clinical trial data [2, 28, 29]. However, complication rate, incidence of infection, and frequency of inappropriate ICD shocks appear to be greater in children [6, 16, 17].
With the increasing prevalence of ICD therapy in children, measurement of disease-related quality of life (DRQoL) and psychological assessment have become more essential [14]. Adult studies indicate that ICD treatment can have a negative impact on the DRQoL and psychological functioning of patients [3, 9, 15]. Adult ICD patients show significantly worse psychological and physical functioning [3], and behavioral changes, such as decreased activity, avoidance, depression, and anxiety [13, 18, 21], have been reported. Receiving ICD shocks is a risk factor for psychological distress in adults [23]. However, the adult ICD population differs from the pediatric population in that ischemic heart disease and cardiomyopathy are most prevalent. Furthermore, children have a more active lifestyle compared with most adults [25].
A few studies on quality of life (QoL) in children with an ICD have been published so far [7, 9, 10, 25, 26]. Dubin et al. [9] found difficulties with social interactions in a young ICD population with a mean age of 28 years. DeMaso et al. [7] studied 20 children (median age 15.1 years [range 9–19]) with ICDs. Half of the patients had underlying congenital heart disease. Feelings of anxiety (total and physiological anxiety, social concerns, and worry/oversensitivity) and depression were significantly more prevalent, and their QoL was strongly correlated with these feelings. Feelings of anxiety and depression were also reported by Eicken et al. [10], who studied a group of 16 children (median age 12.2 years [range 4–16]). Seven patients showed signs of generalized depression and/or anxiety. In 3 patients with severe signs of anxiety, ICD shock had occurred within 6 months preceding the investigation. Although studies in adults suggested a negative influence of appropriate or inappropriate shocks on QoL, this has not been confirmed in these pediatric series [26]. Sears et al. [26] described in their recent article QoL to be independent of the occurrence of shocks in pediatric patients. Furthermore, it is unclear if feelings of anxiety and depression are time dependent and may change during longer-term follow-up.
We therefore studied 30 young patients after ICD implantation and analyzed psychological functioning and DRQoL, with special attention paid to the association with shocks and follow-up time.

Methods

Patients

The study was approved by the Medical Ethical Committee of the Leiden University Medical Center and adhered to the Declaration of Helsinki. Pediatric patients were recruited from the cardiology departments of four academic medical centers in the Netherlands: Amsterdam Medical Center (11 patients), University Medical Center Groningen (7 patients), University Medical Center Utrecht (2 patients), and Leiden University Medical Center (10 patients). These hospitals have a shared patient database for all ICD patients. Participants were eligible for this study if implantation had been performed before the age of 18 years and if they were able to comprehend Dutch. In total, 35 patients met the enrollment criteria. The treating physicians of the different hospitals asked the patients to participate. Four patients chose not to participate for reasons they did not share. One patient had to be excluded because too many data were missing. The participation rate was 85%.
During a period of 4 months, 30 patients were recruited into the study. First, they received written information about the study and were asked to return the informed consent form. Consent was given by parents for children <12 years old; Consent was given by both patient and parents for children 12–18 years old. Next, one researcher interviewed all children at home or, in four cases because of practical reasons (i.e., distance to the hospital), in the hospital. Information was obtained from the parents about age, sex, number of hospitalizations, parental marital status, and parental educational level. Patients filled in questionnaires in another room than their parents, which took approximately 30–35 min.

Measures

Patient characteristics included age, weight, and length at the time of ICD implantation, use of antiarrhythmic medication, underlying cardiovascular disease, ICD characteristics, and the occurrence of appropriate or inappropriate shocks. Both chart review and device interrogation were used to assess the presence of shocks.
To assess psychological problems, the SCL-90-R [1, 19] was used. This self-report rating scale consists of 90 items divided into 9 subscales. The SCL-90-R was administered to the participants >13 years old (N = 25). The Dutch norm group consists of 2366 randomly selected persons from the general population. For this study, the SCL-90-R subscales anxiety (7 items), depressive symptoms (13 items), and sleeping problems (3 items) were used. Respondents report, on a scale ranging from 1 (not at all) to 5 (very often), whether the described symptom had occurred in the previous week. A greater score represents more symptoms of anxiety, depression, or sleep problems. Cronbach’s α for the 3 subscales in this study group ranged from 0.84 to 0.89, which was in line with the Dutch norm group [1].
ICD is a very specific treatment, so we aimed to use a disease-specific measure to assess DRQoL in this group: the WAICD. This instrument is an adaptation of the 26-item Index of Subjective Concerns for People with ICDs (ISCP-ICD) [30] for use with pediatric ICD patients (DeMaso et al. [7]). Items are scored on a 5-point scale ranging form 0 (not at all true) to 4 (extremely true). Items 7, 20, and 26 are reverse-scored to reflect the opposite valence of these questions. Total WAICD score is determined by the total of items with a scoring range of 0 (no worry at all) to 104 (extremely worried). Greater WAICD scores indicate more worries. The internal consistency of the WAICD (26 items) in our study was adequate (Cronbach’s α 0.77). However, a number of items in our study showed a very low (e.g., items 8, 9, 12, 19, 26) or even negative (item 20) item–total correlation or lack of variance [20]. Therefore, the WAICD Short Form (11-items) was constructed (Cronbach’s α 0.83) and used for further analysis with permission of the original investigator (see Table 1). The two forms (WAICD 26 and 11-item version) correlated well (Pearson’s correlation coefficient [PCC] = 0.086) [20].
Table 1
WAICD-SF: 11 items, item–total correlations, and responses
WAICD-SF items (N = 30)
WAICD item no. 26
Item–total correlation
Not at all true
A little true
Sort of true
Quite a bit true
Extremely true
1. It bothers me not knowing when the ICD will fire.
1
0.45
12
11
2
1
3
2. I worry about the ICD firing and creating a scene.
2
0.49
18
3
3
3
2
3. I am afraid of being alone if the ICD fires and I need help.
3
0.63
10
9
3
2
5
4. I worry about the ICD not firing sometime when I need it.
4
0.37
18
7
3
1
5. I can’t stop thinking about the ICD.
6
0.42
16
6
6
1
6. I worry that the ICD will fire when it’s not supposed to.
14
0.56
17
6
3
3
7. I worry about how I will feel when the ICD fires.
15
0.66
12
7
5
2
3
8. I am nervous that if I exercise my heart might start beating faster and make the ICD fire.
16
0.54
13
7
3
3
3
9. I worry about not being able to get a job in future because of the ICD.
19
0.38
21
3
5
10. I worry about traveling to a place where there aren’t any doctors who know about ICDs.
23
0.42
17
9
1
2
11. I worry that paramedics don’t know how the ICD works.
24
0.59
17
7
3
1
1
SF short form

Statistical Analyses

Data were analyzed with the use of SPSS 17.0 software (Chicago, IL). Mean scores (M) of anxiety, depression, and sleeping problems in children with an ICD were compared with the instrument norms using Student t test. Scores on the WAICD-SF were compared with scores of the original instrument. Pearson and Spearman correlations were calculated between DRQoL, psychological problems, time since implantation, and having had shocks or not. Especially this last variable has been identified as possible determinants of well-being in ICD patients [7, 10, 21]. Time since implantation was a variable added by the researchers of the current study. χ2 tests were performed to test the relationship between categorical data and DRQoL and psychological problems. PCCs were calculated to measure relations between the WAICD-SF and the SCL-90-R. For all calculations, p ≤ 0.05 was considered significant. Results were compared with age- and sex-matched reference groups where possible.

Results

Study Subjects

Mean age at time of assessment was 16.3 years (range 9–23) with a mean duration since ICD implantation of 3.6 years (range 1–9). Only seven children were <13 years old at the time of assessment. Table 2 lists the demographic and illness-specific characteristics of the participants. No differences were found between the children interviewed at home or those interviewed in the hospital regarding demographic or disease-related variables and study outcomes. Twelve participants had been admitted to hospital during follow-up. Five underwent battery replacement, 4 underwent lead replacement, and 3 were monitored because of multiple shocks. No differences were found between hospitalized and nonhospitalized patients. Nineteen children were taking beta-blockers. Fifteen patients received ≥1 shock: 10 patients received an appropriate shock, and 7 patients received an inappropriate shock. Lifestyle limitations for this group were to avoid competitive sports (both before and after implantation) and to avoid contact sports after implantation.
Table 2
Sample characteristics and cardiac illness description in 30 pediatric patients with an ICD
No. of patients included
30
Age at implant (years)
13.7 ± 3.6a (range 4.8–22.4)
Sex (male/female)
15/15
Weight (kg) at implant
48.4 ± 17.0 (range 15–94)
Height (cm) at implant
160.3 ± 19.5 (range 105–190)
Beta-blockers used (no.)
19
ICD indication
 SCD survivor
13
 Primary prevention
17
Cardiovascular disease
 Cardiomyopathy
6
 Primary electrical disease
17
 Congenital
7
Implant characteristics
 Epicardial/transvenous approach
2/28
 Single/dual chamber
26/4
 Generator abdominal/subpectoral
4/26
 DFT at implant (mean)
15.1 ± 5.7
Follow-up
 Follow-up after implantation (y)
3.6 ± 2.6
SCD sudden cardiac death, DFT defibrillation threshold
aPlus–minus values are expressed as mean ± SD
At the time of evaluation, 25 children were living with both parents, and 5 children were living with one of their parents. Seven children were in primary school (ages ≤12 years); 19 patients were in secondary school (ages 12–19 years); and 4 patients were working >20 h per week (ages >19 years).

DRQoL of Pediatric Patients with an ICD

Results of the WAICD-SF showed that mean total scores were comparable with the norm group in the original study by DeMaso et al. [7] (M = 29.5 vs. 37.2, respectively). The main worries of the respondents in our study group reported on the WAICD-SF (see Table 3) were as follows: “I am afraid of being alone if the ICD fires and I need help” (66%) followed by “I worry about how I will feel when the ICD fires” (59%) and “I am nervous that if I exercise my heart might start beating faster and make the ICD fire” (55%). Nearly 40% of the pediatric patients were a little concerned about not knowing when the ICD would fire.
Table 3
Psychological problems reported on three SCL-90-R subscales
Groups
Mean (SD) depressive symptoms (N = 16 items [range 16–80])
Mean (SD) anxiety (N = 10 items [range 10–50])
Mean (SD) sleep problems (N = 3 items [range 3–15])
ICD sample (N = 23)
31.6* (6.2)
17.3* (3.9)
7.6* (1.9)
Reference group (N = 2366)a
21.6 (7.6)
12.8 (4.4)
4.5 (2.2)
p < 0.001
aDutch reference group of the SCL-90-R: characteristics of reference group [20]: 50% female, mean age = 41.1, SD = 14.5, age range 17–88 years

Psychological Problems of Pediatric Patients with an ICD

Scores of the patients with an ICD who were ≥13 years old on the domains of anxiety, depression, and sleeping problems of the SCL-90-R were significantly greater than the reference group (T = 7.5, p < 0.001; T = 5.4, p < 0.001; and T = 7.8, p < 0.001, respectively) (see Table 3). No sex differences were found. Patients who had received one or more shocks (both appropriate and inappropriate) reported more depressive symptoms (T = 2.1, p < 0.03). There were no differences between the patients with underlying primary electrical disease, cardiomyopathy, or congenital heart disease, although the number of patients in the respective subgroups were relatively low, thus causing a lack of power.

Correlates of DRQOL

Pediatric patients with an implantation duration >2 years (N = 19) showed significantly more worries on the WAICD-SF (T = 2.1, p < 0.04). Patients who had not yet received a shock (both appropriate and inappropriate) (N = 15) worried less than the other patients (T = 2.1, p < 0.05) (see Table 4). Age at implantation and sex were not associated with worrying or ICD-related HRQoL. There were no differences between the patients with underlying primary electrical disease, cardiomyopathy, or congenital heart disease. Because more than half of the patients (N = 17) had a primary electrical disease and therefore had no restrictions outside of their ICD, no correlation could be found between severity of illness and QoL.
Table 4
Mean (SD) differences between time since implantation and number of shocks and DRQoL (WAICD-SF)
Variables
WAICD-SF mean (SD) p
Time since implantation
 <2 years (N = 11)
5.6 (4.3)
 
 >2 years (N = 19)
11.9 (8.7)
0.049*
Number of shocks
 0 (N = 15)
7.2 (5.3)
 
 ≥1 (N = 15)
12.9 (9.6)
0.045*
SF short form
p < 0.05

Discussion

In this multicenter study, we investigated psychological functioning and DRQoL in pediatric patients with an ICD. A significantly increased rate of anxiety, depression, and sleep problems, as well as worries about their ICD, were reported. These results are in line with previous research with pediatric patients [7]. We found that length of implantation (>2 years) was associated with more worries. The number of shocks, both appropriate and inappropriate, also showed an important impact on worries in our pediatric ICD population. Patients who had received one or more shocks reported significantly more worries compared with those who had not received a shock. This finding is consistent with previous research showing that the unpredictability and frequency of ICD shock delivery [6, 10, 15] are associated with negative emotions.
Studies evaluating QoL in adults with an ICD found greater depression and anxiety levels compared with the general population [1315]. However, it seems that the survival of an out-of-hospital cardiac arrest [14], persistence of ventricular arrhythmias [3], or severity of the underlying disease [13] is more important than ICD implantation itself. Studies in young ICD patients show more signs of depression and anxiety as well [7, 10]. However, these studies did not differentiate between the effect of the underlying disease and the ICD implantation.
Cardiac problems have a major (physical) impact on general HRQoL. For example, in the study by Sears et al. [26], pediatric ICD patients (N = 60) reported on the PedsQL significantly lower psychosocial and physical HRQoL than healthy peers and lower physical HRQoL than chronically ill samples. Moreover, female ICD patients (N = 25) reported lower psychosocial, physical, and cardiac-specific HRQoL than male patients.
In our study, more than half of the patients had a primary electrical disease and were therefore a relatively healthy population. A previous study showed that children who were carrier for an inherited cardiovascular disease, including long QT syndrome, did not show differences in QoL compared with their healthy peers [27]. However, ICD implantation in children with primary electrical disease might have a significant impact on their QoL [22]. These studies make it more likely that ICD implantation has a much greater influence than the presence of the primary electrical disease itself. In the present study, we found a significant effect of the occurrence of shocks on QoL. This has not been found previously in young patients [26], whereas adult studies showed conflicting results: Some of them showed an influence of shocks [13, 15, 18], whereas others did not [21]. The effect of duration of ICD therapy on worrying has neither been found previously. This finding shows that pediatric patients do not necessarily accommodate well to their ICD (more than four of five pediatric patients avoided places or activities after ICD implantation [26] (female patients avoided places significantly more), and they probably need psychological support not only before and immediately after ICD implantation but also during long-term follow-up [5, 8, 25].

Limitations

However, different limitations should be given consideration. One of the major restrictions of this study is the small sample size, which makes statistical analyses difficult to conduct and interpret (low statistical power), a common problem in this illness group [10, 16]. Furthermore, the large range of duration of ICD therapy, the heterogeneity of the underlying diseases, and the variety of the age of the patients also cause problems in the generalization of the results. Because most of these young patients led a relatively normal life besides the presence of their ICD, no correlation could be found between severity of illness and QoL. Another limitation is the fact that the age range of the reference group of the SCL-90-R (see Table 3) was not congruent with the ages of the ICD patients under study. Limited SCL-90-R data are available from pediatric patients with a chronic disease or handicap. In one study [12], SCL-90-R data of 17 patients with pectus excavatum (13 male and 4 female, M 19.6 years, SD 2.5 years at the second time [4 years later] of investigation) were within the normal range. A fourth limitation is the fact that a newly developed disease specific measure (WAICD) had to be adapted because of insufficient psychometric properties in our population under study. Its value as a DRQoL assessment tool must be proven in clinical practice, in conjunction with other more widely used measures, to provide a better understanding of the impact of ICD treatment in children.

Conclusion

The present study shows that young ICD patients experience psychological- and disease-related consequences of their treatment (e.g., do not feel safe, tire easily, and worry about needing an ICD). Compared with normal controls, ICD patients showed more anxiety, depression, and sleeping disorders. Depression level was increased among patients with ICD shocks. In addition, worries about their ICD were increased in patients with ICD shocks and in those who had their ICD for >2 years. These findings underscore the necessity of proper guidance and monitoring of ICD patients to cope with the shocks and hence determine possible psychological problems [24]. Patients with frequent shocks and longer ICD treatment are especially at risk. Last, these findings support the necessity to decrease both appropriate and inappropriate shocks to the lowest possible incidence.

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Pädiatrie

Kombi-Abonnement

Mit e.Med Pädiatrie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Pädiatrie, den Premium-Inhalten der pädiatrischen Fachzeitschriften, inklusive einer gedruckten Pädiatrie-Zeitschrift Ihrer Wahl.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Arrindell WA, Ettema JHM (2005) Symptom checklist SCL-90. Harcourt Test Publishers, Amsterdam Arrindell WA, Ettema JHM (2005) Symptom checklist SCL-90. Harcourt Test Publishers, Amsterdam
2.
Zurück zum Zitat Blom NA (2008) Implantable cardioverter-defibrillators in children. Pacing Clin Electrophysiol 31(Suppl 1):S32–S34PubMedCrossRef Blom NA (2008) Implantable cardioverter-defibrillators in children. Pacing Clin Electrophysiol 31(Suppl 1):S32–S34PubMedCrossRef
3.
Zurück zum Zitat Burke JL, Hallas CN, Clark-Carter D, White D, Connelly D (2003) The psychosocial impact of the implantable cardioverter defibrillator: a meta-analytic review. Br J Health Psychol 8:165–178PubMedCrossRef Burke JL, Hallas CN, Clark-Carter D, White D, Connelly D (2003) The psychosocial impact of the implantable cardioverter defibrillator: a meta-analytic review. Br J Health Psychol 8:165–178PubMedCrossRef
4.
Zurück zum Zitat Cesario DA, Dec GW (2006) Implantable cardioverter-defibrillator therapy in clinical practice. J Am Coll Cardiol 47:1507–1517PubMedCrossRef Cesario DA, Dec GW (2006) Implantable cardioverter-defibrillator therapy in clinical practice. J Am Coll Cardiol 47:1507–1517PubMedCrossRef
5.
Zurück zum Zitat Cohen M, Mansoor D, Langut H, Lorber A (2007) Quality of life, depressed mood, and self-esteem in adolescents with heart disease. Psychosom Med 69:313–318PubMedCrossRef Cohen M, Mansoor D, Langut H, Lorber A (2007) Quality of life, depressed mood, and self-esteem in adolescents with heart disease. Psychosom Med 69:313–318PubMedCrossRef
6.
Zurück zum Zitat Costa R, Silva KR, Mendonça RC, Nishioka SA, Siqueira Sde F, Tamaki WT et al (2007) Incidence of shock and quality of life in young patients with implantable cardioverter-defibrillator. Arq Bras Cardiol 88:228–264 Costa R, Silva KR, Mendonça RC, Nishioka SA, Siqueira Sde F, Tamaki WT et al (2007) Incidence of shock and quality of life in young patients with implantable cardioverter-defibrillator. Arq Bras Cardiol 88:228–264
7.
Zurück zum Zitat DeMaso DR, Lauretti A, Spieth L, Van Der Feen JR, Jay KS, Gauvreau K et al (2004) Psychosocial factors and quality of life in children and adolescents with implantable cardioverter-defibrillators. Am J Cardiol 93:582–587PubMedCrossRef DeMaso DR, Lauretti A, Spieth L, Van Der Feen JR, Jay KS, Gauvreau K et al (2004) Psychosocial factors and quality of life in children and adolescents with implantable cardioverter-defibrillators. Am J Cardiol 93:582–587PubMedCrossRef
8.
Zurück zum Zitat DeMaso DR, Neto LB, Hirshberg J (2009) Psychological and quality of life issues in the young patient with an implantable cardioverter defibrillator. Heart Rhythm 6:130–132PubMedCrossRef DeMaso DR, Neto LB, Hirshberg J (2009) Psychological and quality of life issues in the young patient with an implantable cardioverter defibrillator. Heart Rhythm 6:130–132PubMedCrossRef
9.
Zurück zum Zitat Dubin AM, Batsford WP, Lewis RJ, Rosenfeld LE (1996) Quality-of-life in patients receiving implantable cardioverter defibrillators at or before age 40. Pacing Clin Electrophysiol 19:1555–1559PubMedCrossRef Dubin AM, Batsford WP, Lewis RJ, Rosenfeld LE (1996) Quality-of-life in patients receiving implantable cardioverter defibrillators at or before age 40. Pacing Clin Electrophysiol 19:1555–1559PubMedCrossRef
10.
Zurück zum Zitat Eicken A, Kolb C, Lange S, Brodherr-Heberlein S, Zrenner B, Schreiber C et al (2006) Implantable cardioverter defibrillator (ICD) in children. Int J Cardiol 107:30–35PubMedCrossRef Eicken A, Kolb C, Lange S, Brodherr-Heberlein S, Zrenner B, Schreiber C et al (2006) Implantable cardioverter defibrillator (ICD) in children. Int J Cardiol 107:30–35PubMedCrossRef
11.
Zurück zum Zitat Ezekowitz JA, Armstrong PW, McAlister FA (2003) Implantable cardioverter defibrillators in primary and secondary prevention: a systematic review of randomized, controlled trials. Ann Intern Med 138:445–452PubMed Ezekowitz JA, Armstrong PW, McAlister FA (2003) Implantable cardioverter defibrillators in primary and secondary prevention: a systematic review of randomized, controlled trials. Ann Intern Med 138:445–452PubMed
12.
Zurück zum Zitat Hadolt B, Wallisch A, Egger JW, Höllwarth ME (2011) Body-image, self-concept and mental exposure in patients with pectus excavatum. Pediatr Surg Int 27:665–670PubMedCrossRef Hadolt B, Wallisch A, Egger JW, Höllwarth ME (2011) Body-image, self-concept and mental exposure in patients with pectus excavatum. Pediatr Surg Int 27:665–670PubMedCrossRef
13.
Zurück zum Zitat Herrmann C, von zur Mühen F, Buss U, Kemper S, Wantzen C, Gonska BD (1997) Standardized assessment of psychological well-being and quality-of-life in patients with implanted defibrillators. Pacing Clin Electrophysiol 20:95–103PubMedCrossRef Herrmann C, von zur Mühen F, Buss U, Kemper S, Wantzen C, Gonska BD (1997) Standardized assessment of psychological well-being and quality-of-life in patients with implanted defibrillators. Pacing Clin Electrophysiol 20:95–103PubMedCrossRef
14.
Zurück zum Zitat Kamphuis HCM, de Leeuw JRJ, Derksen R, Hauer R, Winnubst JAM (2002) A 12-month quality of life assessment of cardiac arrest survivors treated with or without an implantable cardioverter defibrillator. Europace 4:417–425PubMedCrossRef Kamphuis HCM, de Leeuw JRJ, Derksen R, Hauer R, Winnubst JAM (2002) A 12-month quality of life assessment of cardiac arrest survivors treated with or without an implantable cardioverter defibrillator. Europace 4:417–425PubMedCrossRef
15.
Zurück zum Zitat Kamphuis HCM, de Leeuw JRJ, Derksen R, Hauer RNW, Winnubst JAM (2003) Implantable cardioverter defibrillator recipients: quality of life in recipients with and without ICD shock delivery: a prospective study. Europace 5:381–389PubMedCrossRef Kamphuis HCM, de Leeuw JRJ, Derksen R, Hauer RNW, Winnubst JAM (2003) Implantable cardioverter defibrillator recipients: quality of life in recipients with and without ICD shock delivery: a prospective study. Europace 5:381–389PubMedCrossRef
16.
Zurück zum Zitat Korte T, Koditz H, Niehaus M, Paul T, Tebbenjohanns J (2004) High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator. Pacing Clin Electrophysiol 27:924–932PubMedCrossRef Korte T, Koditz H, Niehaus M, Paul T, Tebbenjohanns J (2004) High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator. Pacing Clin Electrophysiol 27:924–932PubMedCrossRef
17.
Zurück zum Zitat Link MS, Hill SL, Cliff DL, Swygman CA, Foote CB, Homoud MK et al (1999) Comparison of frequency of complications of implantable cardioverter-defibrillators in children versus adults. Am J Cardiol 83:263–266PubMedCrossRef Link MS, Hill SL, Cliff DL, Swygman CA, Foote CB, Homoud MK et al (1999) Comparison of frequency of complications of implantable cardioverter-defibrillators in children versus adults. Am J Cardiol 83:263–266PubMedCrossRef
18.
Zurück zum Zitat Luyster FS, Hughes JW, Waechter D, Josephson R (2006) Resource loss predicts depression and anxiety among patients treated with an implantable cardioverter defibrillator. Psychosom Med 68:794–800PubMedCrossRef Luyster FS, Hughes JW, Waechter D, Josephson R (2006) Resource loss predicts depression and anxiety among patients treated with an implantable cardioverter defibrillator. Psychosom Med 68:794–800PubMedCrossRef
19.
Zurück zum Zitat Müller JM, Postert C, Beyer T, Furniss T, Achtergarde S (2010) Comparison of eleven short versions of the Symptom Checklist 90-Revised (SCL-90-R) for use in the assessment of general psychopathology. J Psychopathol Behav Assess 32:246–254CrossRef Müller JM, Postert C, Beyer T, Furniss T, Achtergarde S (2010) Comparison of eleven short versions of the Symptom Checklist 90-Revised (SCL-90-R) for use in the assessment of general psychopathology. J Psychopathol Behav Assess 32:246–254CrossRef
20.
Zurück zum Zitat Nunnally JC, Bernstein IR (1994) Psychometric theory, 3rd edn. McGraw-Hill, New York Nunnally JC, Bernstein IR (1994) Psychometric theory, 3rd edn. McGraw-Hill, New York
21.
Zurück zum Zitat Pedersen SS, van Domburg RT, Theuns DAMJ, Jordaens L, Erdman RAM (2005) Concerns about the implantable cardioverter defibrillator: a determinant of anxiety and depressive symptoms independent of experienced shocks. Am Heart J 149:664–669PubMedCrossRef Pedersen SS, van Domburg RT, Theuns DAMJ, Jordaens L, Erdman RAM (2005) Concerns about the implantable cardioverter defibrillator: a determinant of anxiety and depressive symptoms independent of experienced shocks. Am Heart J 149:664–669PubMedCrossRef
22.
Zurück zum Zitat Schwartz PJ, Crotti L (2008) Ion channel diseases in children: manifestations and management. Curr Opin Cardiol 23:184–191PubMedCrossRef Schwartz PJ, Crotti L (2008) Ion channel diseases in children: manifestations and management. Curr Opin Cardiol 23:184–191PubMedCrossRef
23.
Zurück zum Zitat Sears SF, Burns JL, Handberg E, Sotile WM, Conti JB (2001) Young at heart: understanding the unique psychosocial adjustment of young implantable cardioverter defibrillator recipients. Pacing Clin Electrophysiol 24:1113–1117PubMedCrossRef Sears SF, Burns JL, Handberg E, Sotile WM, Conti JB (2001) Young at heart: understanding the unique psychosocial adjustment of young implantable cardioverter defibrillator recipients. Pacing Clin Electrophysiol 24:1113–1117PubMedCrossRef
24.
Zurück zum Zitat Sears SF, Sowell LD, Kuhl EA, Kovacs AH, Serber ER, Handberg E et al (2007) The ICD shock and stress management program: a randomized trial of psychosocial treatment to optimize quality of life in ICD patients. Pacing Clin Electrophysiol 30:1–7CrossRef Sears SF, Sowell LD, Kuhl EA, Kovacs AH, Serber ER, Handberg E et al (2007) The ICD shock and stress management program: a randomized trial of psychosocial treatment to optimize quality of life in ICD patients. Pacing Clin Electrophysiol 30:1–7CrossRef
25.
Zurück zum Zitat Sears SF, St. Amant JB, Zeigler V (2009) Psychosocial considerations for children and young adolescents with implantable cardioverter defibrillators: an update. Pacing Clin Electrophysiol 32(Suppl):S80–S82PubMedCrossRef Sears SF, St. Amant JB, Zeigler V (2009) Psychosocial considerations for children and young adolescents with implantable cardioverter defibrillators: an update. Pacing Clin Electrophysiol 32(Suppl):S80–S82PubMedCrossRef
26.
Zurück zum Zitat Sears SF, Hazelton G, St. Amant JB, Matchett M, Kovacs A, Vazquez LD et al (2011) Quality of life in pediatric patients with implantable cardioverter defibrillators. Am J Cardiol 107:1023–1027PubMedCrossRef Sears SF, Hazelton G, St. Amant JB, Matchett M, Kovacs A, Vazquez LD et al (2011) Quality of life in pediatric patients with implantable cardioverter defibrillators. Am J Cardiol 107:1023–1027PubMedCrossRef
27.
Zurück zum Zitat Smets EMA, Stam MMH, Meulenkamp TM, Van Langen IM, Wilde AAM, Wiegman A et al (2008) Health-related quality of life of children with a positive carrier status for inherited cardiovascular diseases. Am J Med Genet A 146A:700–707PubMedCrossRef Smets EMA, Stam MMH, Meulenkamp TM, Van Langen IM, Wilde AAM, Wiegman A et al (2008) Health-related quality of life of children with a positive carrier status for inherited cardiovascular diseases. Am J Med Genet A 146A:700–707PubMedCrossRef
28.
Zurück zum Zitat Stefanelli CB, Bradley DJ, Leroy S, Dick MI, Serwer GA, Fischbach PS (2002) Implantable cardioverter defibrillator therapy for life-threatening arrhythmias in young patients. J Interv Card Electrophysiol 6:235–244PubMedCrossRef Stefanelli CB, Bradley DJ, Leroy S, Dick MI, Serwer GA, Fischbach PS (2002) Implantable cardioverter defibrillator therapy for life-threatening arrhythmias in young patients. J Interv Card Electrophysiol 6:235–244PubMedCrossRef
29.
Zurück zum Zitat ten Harkel AD, Blom NA, Reimer AG, Tukkie R, Sreeram N, Bink-Boelkens MT (2005) Implantable cardioverter defibrillator implantation in children in The Netherlands. Eur J Pediatr 164:436–441PubMedCrossRef ten Harkel AD, Blom NA, Reimer AG, Tukkie R, Sreeram N, Bink-Boelkens MT (2005) Implantable cardioverter defibrillator implantation in children in The Netherlands. Eur J Pediatr 164:436–441PubMedCrossRef
30.
Zurück zum Zitat Vitale MB, Funk M (1995) Quality of life in younger persons with an implantable defibrillator. Dimens Crit Care Nurs 14:100–111PubMedCrossRef Vitale MB, Funk M (1995) Quality of life in younger persons with an implantable defibrillator. Dimens Crit Care Nurs 14:100–111PubMedCrossRef
Metadaten
Titel
Psychological Functioning and Disease-Related Quality of Life in Pediatric Patients With an Implantable Cardioverter Defibrillator
verfasst von
H. M. Koopman
C. M. J. Vrijmoet-Wiersma
J. N. D. Langius
F. van den Heuvel
S. A. Clur
C. A. Blank
N. A. Blom
A. D. J. ten Harkel
Publikationsdatum
01.04.2012
Verlag
Springer-Verlag
Erschienen in
Pediatric Cardiology / Ausgabe 4/2012
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-012-0175-1

Weitere Artikel der Ausgabe 4/2012

Pediatric Cardiology 4/2012 Zur Ausgabe

From Other Journals

From Other Journals

Die „Zehn Gebote“ des Endokarditis-Managements

30.04.2024 Endokarditis Leitlinie kompakt

Worauf kommt es beim Management von Personen mit infektiöser Endokarditis an? Eine Kardiologin und ein Kardiologe fassen die zehn wichtigsten Punkte der neuen ESC-Leitlinie zusammen.

Strenge Blutdruckeinstellung lohnt auch im Alter noch

30.04.2024 Arterielle Hypertonie Nachrichten

Ältere Frauen, die von chronischen Erkrankungen weitgehend verschont sind, haben offenbar die besten Chancen, ihren 90. Geburtstag zu erleben, wenn ihr systolischer Blutdruck < 130 mmHg liegt. Das scheint selbst für 80-Jährige noch zu gelten.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Dihydropyridin-Kalziumantagonisten können auf die Nieren gehen

30.04.2024 Hypertonie Nachrichten

Im Vergleich zu anderen Blutdrucksenkern sind Kalziumantagonisten vom Diyhdropyridin-Typ mit einem erhöhten Risiko für eine Mikroalbuminurie und in Abwesenheit eines RAS-Blockers auch für ein terminales Nierenversagen verbunden.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.