Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 1/2010

01.01.2010

Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical results

verfasst von: Marcus Wieczorek, Reinhard Hoeltgen, Martin Brueck, Dirk Bandorski, Elvan Akin, Ali Reza Salili

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 1/2010

Einloggen, um Zugang zu erhalten

Abstract

Background

The electrical disconnection of the pulmonary veins (PV) plays an important role in the ablation strategy of paroxysmal atrial fibrillation (PAF). Circumferential antral ablation with a conventional ablation technique using a steerable ablation catheter is sometimes difficult to perform and does not always result in isolation of the targeted PV.

Methods

Patients with symptomatic PAF were treated with a novel circular mapping/ablation catheter (PVAC). Ablation was performed in the antral region of the PV with a power-modulated bipolar/unipolar RF generator using 8–10 W until isolation of the vein was achieved. Seven-day Holter monitor recordings were performed off antiarrhythmic drugs at 3 and 6 months after the initial procedure. A subgroup of patients had received an implantable recorder before ablation, and the device was interrogated at the same time. The primary objective of this study is acute isolation of the targeted PV, and the second objective is clinical efficacy with a short-term follow-up.

Results

In 73 patients, 290 PV could be reached with the PVAC. Antral ablation was performed in 244 PV showing PV potentials. Acutely, 243 PV (99%) were isolated with the PVAC after 21 ± 7 energy applications per patient with a mean fluoroscopy time of 20 ± 11 min. Total procedure time was 122 ± 27 min. No complications were observed. Follow-up at 3 and 6 months showed freedom from AF in 61 of 73 (84%) patients and 38 of 45 patients (85%), respectively, off antiarrhythmic drugs.

Conclusions

PV isolation by duty-cycled unipolar/bipolar RF ablation can be effectively and safely performed with a circular, decapolar catheter. Clinical results at 3 and 6 months after ablation are encouraging with the need for longer follow-up intervals.
Literatur
1.
Zurück zum Zitat Boersma, L. V., Wijffels, M. C., Oral, H., Wever, E. F., & Morady, F. (2008). Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter. Heart Rhythm, 5, 1635–1642.CrossRefPubMed Boersma, L. V., Wijffels, M. C., Oral, H., Wever, E. F., & Morady, F. (2008). Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter. Heart Rhythm, 5, 1635–1642.CrossRefPubMed
2.
Zurück zum Zitat Bugge, E., Nicholson, I. A., & Thomas, S. P. (2005). Comparison of bipolar and unipolar radiofrequency ablation in an in vivo experimental model. European Journal of Cardio-thoracic Surgery, 28, 76–80.CrossRefPubMed Bugge, E., Nicholson, I. A., & Thomas, S. P. (2005). Comparison of bipolar and unipolar radiofrequency ablation in an in vivo experimental model. European Journal of Cardio-thoracic Surgery, 28, 76–80.CrossRefPubMed
3.
Zurück zum Zitat Scharf, C., Boersma, L. V. A., & Kanagaratnam, P. (2008). Long term efficacy when using multi-array catheters and phased radiofrequency energy for ablation of chronic atrial fibrillation (abstract). Journal of the American College of Cardiology, 51, A8. Scharf, C., Boersma, L. V. A., & Kanagaratnam, P. (2008). Long term efficacy when using multi-array catheters and phased radiofrequency energy for ablation of chronic atrial fibrillation (abstract). Journal of the American College of Cardiology, 51, A8.
4.
Zurück zum Zitat Michaud, G., Martin, D., & John, R. (2008). Safety using novel multi-array catheters and phased radiofrequency energy in left atrial ablation for persistent atrial fibrillation (abstract). Heart Rhythm, 5(Suppl), S313–S314. Michaud, G., Martin, D., & John, R. (2008). Safety using novel multi-array catheters and phased radiofrequency energy in left atrial ablation for persistent atrial fibrillation (abstract). Heart Rhythm, 5(Suppl), S313–S314.
5.
Zurück zum Zitat Wijffels, M. C., Oosterhout, M., & Vos, M. (2008). Characterization of atrial lesions using multipolar ablation catheters in pigs (abstract suppl). European Heart Journal, 29, 412. Wijffels, M. C., Oosterhout, M., & Vos, M. (2008). Characterization of atrial lesions using multipolar ablation catheters in pigs (abstract suppl). European Heart Journal, 29, 412.
6.
Zurück zum Zitat Iwasa, A., Storey, A., Tashakkor, B., & Feld, K. (2003). Identification of pulmonary vein potentials by differential site atrial pacing in patients with paroxysmal atrial fibrillation: enhanced detection by pulmonary vein pacing. Journal of Cardiovascular Electrophysiology, 14, 1311–1318.CrossRefPubMed Iwasa, A., Storey, A., Tashakkor, B., & Feld, K. (2003). Identification of pulmonary vein potentials by differential site atrial pacing in patients with paroxysmal atrial fibrillation: enhanced detection by pulmonary vein pacing. Journal of Cardiovascular Electrophysiology, 14, 1311–1318.CrossRefPubMed
7.
Zurück zum Zitat Arentz, T., von Rosenthal, J., Blum, T., Stockinger, J., Burkle, G., Weber, R., et al. (2003). Feasibility and safety of pulmonary vein isolation using a new mapping and navigation system in patients with refractory atrial fibrillation. Circulation, 108, 2484–2490.CrossRefPubMed Arentz, T., von Rosenthal, J., Blum, T., Stockinger, J., Burkle, G., Weber, R., et al. (2003). Feasibility and safety of pulmonary vein isolation using a new mapping and navigation system in patients with refractory atrial fibrillation. Circulation, 108, 2484–2490.CrossRefPubMed
8.
Zurück zum Zitat Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., et al. (2000). Circumferential radiofrequency ablation of pulmonary vein ostia: a new anatomic approach for curing atrial fibrillation. Circulation, 102, 2619–2628.PubMed Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., et al. (2000). Circumferential radiofrequency ablation of pulmonary vein ostia: a new anatomic approach for curing atrial fibrillation. Circulation, 102, 2619–2628.PubMed
9.
Zurück zum Zitat Arentz, T., von Rosenthal, J., Weber, R., Burkle, G., Blum, T., Stockinger, J., et al. (2005). Effects of circumferential ostial radiofrequency lesions on pulmonary vein activation recorded with a multipolar basket catheter. Journal of Cardiovascular Electrophysiology, 16, 302–308.CrossRefPubMed Arentz, T., von Rosenthal, J., Weber, R., Burkle, G., Blum, T., Stockinger, J., et al. (2005). Effects of circumferential ostial radiofrequency lesions on pulmonary vein activation recorded with a multipolar basket catheter. Journal of Cardiovascular Electrophysiology, 16, 302–308.CrossRefPubMed
10.
Zurück zum Zitat Tondo, C., Mantica, M., Russo, G., Karapatsoudi, E., Lucchina, A., Nigro, F., et al. (2005). A new nonfluoroscopic navigation system to guide pulmonary vein isolation. Pacing and Clinical Electrophysiology, 28(Suppl 1), S102–S105.CrossRefPubMed Tondo, C., Mantica, M., Russo, G., Karapatsoudi, E., Lucchina, A., Nigro, F., et al. (2005). A new nonfluoroscopic navigation system to guide pulmonary vein isolation. Pacing and Clinical Electrophysiology, 28(Suppl 1), S102–S105.CrossRefPubMed
11.
Zurück zum Zitat Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Salvati, A., et al. (2001). Prospects of the treatment of atrial fibrillation. Circumferential radiofrequency ablation of pulmonary vein ostia. Recenti Prog Med, 92, 508–512.PubMed Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Salvati, A., et al. (2001). Prospects of the treatment of atrial fibrillation. Circumferential radiofrequency ablation of pulmonary vein ostia. Recenti Prog Med, 92, 508–512.PubMed
12.
Zurück zum Zitat Ouyang, F., Bansch, D., Ernst, S., Schaumann, A., Hachiya, H., Chen, M., et al. (2004). Complete isolation of left atrium surrounding the pulmonary veins: new insights from the double-Lasso technique in paroxysmal atrial fibrillation. Circulation, 110, 2090–2096.CrossRefPubMed Ouyang, F., Bansch, D., Ernst, S., Schaumann, A., Hachiya, H., Chen, M., et al. (2004). Complete isolation of left atrium surrounding the pulmonary veins: new insights from the double-Lasso technique in paroxysmal atrial fibrillation. Circulation, 110, 2090–2096.CrossRefPubMed
13.
Zurück zum Zitat Cheema, A., Vasamreddy, C. R., Dalal, D., Marine, J. E., Dong, J., Henrikson, C. A., et al. (2006). Long-term single procedure efficacy of catheter ablation of atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 15, 145–155.CrossRefPubMed Cheema, A., Vasamreddy, C. R., Dalal, D., Marine, J. E., Dong, J., Henrikson, C. A., et al. (2006). Long-term single procedure efficacy of catheter ablation of atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 15, 145–155.CrossRefPubMed
14.
Zurück zum Zitat Cheema, A., Dong, J., Dalal, D., Vasamreddy, C. R., Marine, J. E., Henrikson, C. A., et al. (2006). Long-term safety and efficacy of circumferential ablation with pulmonary vein isolation. Journal of Cardiovascular Electrophysiology, 17, 1080–1085.CrossRefPubMed Cheema, A., Dong, J., Dalal, D., Vasamreddy, C. R., Marine, J. E., Henrikson, C. A., et al. (2006). Long-term safety and efficacy of circumferential ablation with pulmonary vein isolation. Journal of Cardiovascular Electrophysiology, 17, 1080–1085.CrossRefPubMed
15.
Zurück zum Zitat Hocini, M., Sanders, P., Jais, P., Hsu, L. F., Takahashi, Y., Rotter, M., et al. (2004). Techniques for curative treatment of atrial fibrillation. Journal of Cardiovascular Electrophysiology, 15, 1467–1471.CrossRefPubMed Hocini, M., Sanders, P., Jais, P., Hsu, L. F., Takahashi, Y., Rotter, M., et al. (2004). Techniques for curative treatment of atrial fibrillation. Journal of Cardiovascular Electrophysiology, 15, 1467–1471.CrossRefPubMed
16.
Zurück zum Zitat Verma, A., Patel, D., Famy, T., Martin, D. O., Burkhardt, J. D., Elayi, S. C., et al. (2007). Efficacy of adjuvant anterior left atrial ablation during intracardiac echocardiography-guided pulmonary vein antrum isolation for atrial fibrillation. Journal of Cardiovascular Electrophysiology, 18, 151–156.CrossRefPubMed Verma, A., Patel, D., Famy, T., Martin, D. O., Burkhardt, J. D., Elayi, S. C., et al. (2007). Efficacy of adjuvant anterior left atrial ablation during intracardiac echocardiography-guided pulmonary vein antrum isolation for atrial fibrillation. Journal of Cardiovascular Electrophysiology, 18, 151–156.CrossRefPubMed
17.
Zurück zum Zitat Saliba, W., Wilber, D., Packer, D., Marrouche, N., Schweikert, R., Pisano, E., et al. (2002). Circumferential ultrasound ablation for pulmonary vein isolation: analysis of acute and chronic failures. Journal of Cardiovascular Electrophysiology, 13, 957–961.CrossRefPubMed Saliba, W., Wilber, D., Packer, D., Marrouche, N., Schweikert, R., Pisano, E., et al. (2002). Circumferential ultrasound ablation for pulmonary vein isolation: analysis of acute and chronic failures. Journal of Cardiovascular Electrophysiology, 13, 957–961.CrossRefPubMed
18.
Zurück zum Zitat Natale, A., Pisano, E., Shewchik, J., Bash, D., Fanelli, R., Potenza, D., et al. (2000). First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation. Circulation, 102, 1879–1882.PubMed Natale, A., Pisano, E., Shewchik, J., Bash, D., Fanelli, R., Potenza, D., et al. (2000). First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation. Circulation, 102, 1879–1882.PubMed
19.
Zurück zum Zitat Reddy, V. Y., Houghtaling, C., Fallon, J., Fischer, G., Farr, N., Clarke, J., et al. (2004). Use of a diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model. Pacing and Clinical Electrophysiology, 27, 52–57.CrossRefPubMed Reddy, V. Y., Houghtaling, C., Fallon, J., Fischer, G., Farr, N., Clarke, J., et al. (2004). Use of a diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model. Pacing and Clinical Electrophysiology, 27, 52–57.CrossRefPubMed
20.
Zurück zum Zitat Wong, T., Markides, V., Peters, N. S., & Davies, D. W. (2004). Percutaneous pulmonary vein cryoablation to treat atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 11, 117–126.CrossRefPubMed Wong, T., Markides, V., Peters, N. S., & Davies, D. W. (2004). Percutaneous pulmonary vein cryoablation to treat atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 11, 117–126.CrossRefPubMed
21.
Zurück zum Zitat Arruda, M. S., He, D. S., Friedman, P., Nakagawa, H., Bruce, C., Azegami, K., et al. (2007). A novel mesh electrode catheter for mapping and radiofrequency delivery at the left atrium–pulmonary vein junction: a single-catheter approach to pulmonary vein antrum isolation. Journal of Cardiovascular Electrophysiology, 18, 206–211.CrossRefPubMed Arruda, M. S., He, D. S., Friedman, P., Nakagawa, H., Bruce, C., Azegami, K., et al. (2007). A novel mesh electrode catheter for mapping and radiofrequency delivery at the left atrium–pulmonary vein junction: a single-catheter approach to pulmonary vein antrum isolation. Journal of Cardiovascular Electrophysiology, 18, 206–211.CrossRefPubMed
22.
Zurück zum Zitat Steinwender, C., Honig, S., Leisch, F., & Hofmann, R. (2008). Acute results of pulmonary vein isolation in patients with paroxysmal atrial fibrillation using a single mesh catheter. Journal of Cardiovascular Electrophysiology, 20, 147–152.CrossRefPubMed Steinwender, C., Honig, S., Leisch, F., & Hofmann, R. (2008). Acute results of pulmonary vein isolation in patients with paroxysmal atrial fibrillation using a single mesh catheter. Journal of Cardiovascular Electrophysiology, 20, 147–152.CrossRefPubMed
23.
Zurück zum Zitat Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., et al. (2005). Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation, 111, 1100–1105.CrossRefPubMed Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., et al. (2005). Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation, 111, 1100–1105.CrossRefPubMed
24.
Zurück zum Zitat Saito, T., Waki, K., & Becker, A. E. (2000). Left atrial myocardial extension onto pulmonary veins in humans: anatomic observations relevant for atrial arrhythmias. Journal of Cardiovascular Electrophysiology, 11, 888–894.CrossRefPubMed Saito, T., Waki, K., & Becker, A. E. (2000). Left atrial myocardial extension onto pulmonary veins in humans: anatomic observations relevant for atrial arrhythmias. Journal of Cardiovascular Electrophysiology, 11, 888–894.CrossRefPubMed
25.
Zurück zum Zitat Hertervig, E., Kongstad, O., Ljungstrom, E., Olsson, B., & Yuan, S. (2008). Pulmonary vein potentials in patients with and without atrial fibrillation. Europace, 10, 692–697.CrossRefPubMed Hertervig, E., Kongstad, O., Ljungstrom, E., Olsson, B., & Yuan, S. (2008). Pulmonary vein potentials in patients with and without atrial fibrillation. Europace, 10, 692–697.CrossRefPubMed
26.
Zurück zum Zitat Hocini, M., Sanders, P., Jais, P., Hsu, L. F., Weerasoriya, R., Scavee, C., et al. (2005). Prevalence of pulmonary vein disconnection after anatomical ablation for atrial fibrillation: consequences of wide atrial encircling of the pulmonary veins. European Heart Journal, 26, 696–704.CrossRefPubMed Hocini, M., Sanders, P., Jais, P., Hsu, L. F., Weerasoriya, R., Scavee, C., et al. (2005). Prevalence of pulmonary vein disconnection after anatomical ablation for atrial fibrillation: consequences of wide atrial encircling of the pulmonary veins. European Heart Journal, 26, 696–704.CrossRefPubMed
27.
Zurück zum Zitat Macle, L., Jais, P., Scavee, C., Weerasooriya, R., Shah, D. C., Hocini, M., et al. (2003). Electrophysiologically guided pulmonary vein isolation during sustained atrial fibrillation. Journal of Cardiovascular Electrophysiology, 14, 255–260.CrossRefPubMed Macle, L., Jais, P., Scavee, C., Weerasooriya, R., Shah, D. C., Hocini, M., et al. (2003). Electrophysiologically guided pulmonary vein isolation during sustained atrial fibrillation. Journal of Cardiovascular Electrophysiology, 14, 255–260.CrossRefPubMed
28.
Zurück zum Zitat Karch, M. R., Zrenner, B., Deisenhofer, I., Schreieck, J., Ndrepepa, G., Dong, J., et al. (2005). Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation: a randomized comparison between 2 current ablation strategies. Circulation, 111, 2875–2880.CrossRefPubMed Karch, M. R., Zrenner, B., Deisenhofer, I., Schreieck, J., Ndrepepa, G., Dong, J., et al. (2005). Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation: a randomized comparison between 2 current ablation strategies. Circulation, 111, 2875–2880.CrossRefPubMed
29.
Zurück zum Zitat Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., et al. (2007). Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. European Heart Journal, 28, 2231–2237.CrossRefPubMed Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., et al. (2007). Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. European Heart Journal, 28, 2231–2237.CrossRefPubMed
30.
Zurück zum Zitat Schmidt, B., Antz, M., Ernst, S., Ouyang, F., Falk, P., Chun, J. K., et al. (2007). Pulmonary vein isolation by high-intensity focused ultrasound: first-in-man study with a steerable balloon catheter. Heart Rhythm, 4, 575–584.CrossRefPubMed Schmidt, B., Antz, M., Ernst, S., Ouyang, F., Falk, P., Chun, J. K., et al. (2007). Pulmonary vein isolation by high-intensity focused ultrasound: first-in-man study with a steerable balloon catheter. Heart Rhythm, 4, 575–584.CrossRefPubMed
31.
Zurück zum Zitat Fredersdorf, S., Weber, S., Jilek, C., Heinicke, N., VON Bary, C., Jungbauer, C., et al. (2009). Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator. Journal of Cardiovascular Electrophysiology, 20, 1097–1101. Fredersdorf, S., Weber, S., Jilek, C., Heinicke, N., VON Bary, C., Jungbauer, C., et al. (2009). Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator. Journal of Cardiovascular Electrophysiology, 20, 1097–1101.
Metadaten
Titel
Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical results
verfasst von
Marcus Wieczorek
Reinhard Hoeltgen
Martin Brueck
Dirk Bandorski
Elvan Akin
Ali Reza Salili
Publikationsdatum
01.01.2010
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 1/2010
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-009-9446-z

Weitere Artikel der Ausgabe 1/2010

Journal of Interventional Cardiac Electrophysiology 1/2010 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.