Skip to main content
Erschienen in: Cardiovascular Engineering 4/2010

01.12.2010 | Original Paper

Pulse Pressure, Arterial Compliance and Wave Reflection Under Differential Vasoactive and Mechanical Loading

verfasst von: John K-J. Li, Ying Zhu, Pamela S. Geipel

Erschienen in: Cardiovascular Engineering | Ausgabe 4/2010

Einloggen, um Zugang zu erhalten

Abstract

Similar pulse pressure increases and flow reductions have been reported by many investigators, despite dissimilar forms of arterial loading applied. Increased vascular load is most commonly observed due to mechanical and vasoactive interventions. The present study intended to differentiate the hemodynamic contributions of these two forms of arterial loading at closely matched blood pressure levels. To accomplish this, proximal aortic characteristic impedance (Z o ), total arterial compliance (C), peripheral vascular resistance (R s ) and time-domain resolved forward (P f ) and reflected (P r ) waves were obtained in six anesthetized, thoracotomized and ventilated dogs. Acute loading was accomplished by brief descending thoracic aorta (DTA) occlusion or by intravenous bolus infusion of methoxamine (MTX:5 mg/ml) Systolic pressure increases were matched to a similar extent. Results showed that pulse pressures were drastically increased, reflecting large increases in wave reflections and decreases in arterial compliances. Changes in Z o , R s and C were quantitatively different between the two forms of loading. DTA occlusion primarily increased Z o and R s with a concurrently large reduction in C. MTX infusion significantly increased small vessel R s to the same extent as DTA occlusion, but with a slight decrease in C secondary to an increase in pressure, with Z o unchanged. Examination of dynamic loading showed similar increases in reflection coefficients, but P f and P r were qualitatively different. We conclude that vasoactive methoxamine infusion provides primarily an increased resistive load, while mechanical DTA occlusion provides an increased complex load to the left ventricle. These loads also occur earlier and variably during ventricular ejection.
Literatur
Zurück zum Zitat Berger DS, Li JK-J. Concurrent compliance reduction and increased peripheral resistance in the manifestation of isolated systolic hypertension. Am J Cardiol. 1990;65:67–71.CrossRefPubMed Berger DS, Li JK-J. Concurrent compliance reduction and increased peripheral resistance in the manifestation of isolated systolic hypertension. Am J Cardiol. 1990;65:67–71.CrossRefPubMed
Zurück zum Zitat Brin KP, Yin FCP. Effect of nitroprusside on wave reflections in patients with heart failure. Ann Biomed Eng. 1984;12:135–50.CrossRefPubMed Brin KP, Yin FCP. Effect of nitroprusside on wave reflections in patients with heart failure. Ann Biomed Eng. 1984;12:135–50.CrossRefPubMed
Zurück zum Zitat Cohn JN, Franciosa JA. Vasodilator therapy of cardiac failure. N Engl J Med. 1977;297:254–8.CrossRefPubMed Cohn JN, Franciosa JA. Vasodilator therapy of cardiac failure. N Engl J Med. 1977;297:254–8.CrossRefPubMed
Zurück zum Zitat Du FY, Chen X-L, Drzewiecki G, Li JK-J, Kedem J. Hypervolemia improves global and local function and efficiency in postischemic myocardium. Clin Exp Pharmacol Physiol. 2001;28:630–6.CrossRefPubMed Du FY, Chen X-L, Drzewiecki G, Li JK-J, Kedem J. Hypervolemia improves global and local function and efficiency in postischemic myocardium. Clin Exp Pharmacol Physiol. 2001;28:630–6.CrossRefPubMed
Zurück zum Zitat Ferguson JJ III, Randall OS. Hemodynamic correlates of arterial compliance. Cathet Cardiovasc Diagn. 1986;12:376–80.CrossRefPubMed Ferguson JJ III, Randall OS. Hemodynamic correlates of arterial compliance. Cathet Cardiovasc Diagn. 1986;12:376–80.CrossRefPubMed
Zurück zum Zitat Geipel PS, Li JK-J. Assessing wave reflections in the systemic arterial tree. In: Proc. IEEE 9th Ann. Conf. Eng. Med. Biol. 1987. p. 880–1. Geipel PS, Li JK-J. Assessing wave reflections in the systemic arterial tree. In: Proc. IEEE 9th Ann. Conf. Eng. Med. Biol. 1987. p. 880–1.
Zurück zum Zitat Geipel PS, Li JK-J, Laskey WK, Noordergraaf A. Ventricular performance evaluated from load sensitivity. In: Proc. 9th. Int. Cardiovasc. System Dynamics Conf. 1989. p. 309–12. Geipel PS, Li JK-J, Laskey WK, Noordergraaf A. Ventricular performance evaluated from load sensitivity. In: Proc. 9th. Int. Cardiovasc. System Dynamics Conf. 1989. p. 309–12.
Zurück zum Zitat Gundel W, Cherry G, Rajagopalan B, Tan L-B, Lee G, Schultz D. Aortic input impedance in man: acute response to vasodilator drugs. Circulation. 1981;63:1305–14.PubMed Gundel W, Cherry G, Rajagopalan B, Tan L-B, Lee G, Schultz D. Aortic input impedance in man: acute response to vasodilator drugs. Circulation. 1981;63:1305–14.PubMed
Zurück zum Zitat Imai S, Shigei T, Hashimoto K. Cardiac actions of methoxamine. Circ Res. 1961;9:552–60.PubMed Imai S, Shigei T, Hashimoto K. Cardiac actions of methoxamine. Circ Res. 1961;9:552–60.PubMed
Zurück zum Zitat Li JK-J. Dynamics of the vascular system. Singapore: World Scientific Publishing Co; 2004. Li JK-J. Dynamics of the vascular system. Singapore: World Scientific Publishing Co; 2004.
Zurück zum Zitat Li JK-J. The arterial circulation: physical principles and clinical applications. Totowa: Humana Press; 2000. Li JK-J. The arterial circulation: physical principles and clinical applications. Totowa: Humana Press; 2000.
Zurück zum Zitat Li JK-J, Melbin J, Noordergraaf A. Directional disparity of pulse wave reflections in dog arteries. Am J Physiol. 1984;247:H95–9.PubMed Li JK-J, Melbin J, Noordergraaf A. Directional disparity of pulse wave reflections in dog arteries. Am J Physiol. 1984;247:H95–9.PubMed
Zurück zum Zitat Li JK-J. Time domain resolution of forward and reflected waves in the aorta. IEEE Trans Biomed Eng. 1986;BME-33:783–5. Li JK-J. Time domain resolution of forward and reflected waves in the aorta. IEEE Trans Biomed Eng. 1986;BME-33:783–5.
Zurück zum Zitat Li JK-J. Increased arterial pulse wave reflections and pulsatile energy loss in acute hypertension. Angiology J Vasc Dis. 1989;40:730–5. Li JK-J. Increased arterial pulse wave reflections and pulsatile energy loss in acute hypertension. Angiology J Vasc Dis. 1989;40:730–5.
Zurück zum Zitat Li JK-J, Cui T, Drzewiecki G. A nonlinear model of the arterial system incorporating a pressure-dependent compliance. IEEE Trans. Biomed. Eng., 1990;BME-37:673–8. Li JK-J, Cui T, Drzewiecki G. A nonlinear model of the arterial system incorporating a pressure-dependent compliance. IEEE Trans. Biomed. Eng., 1990;BME-37:673–8.
Zurück zum Zitat Li JK-J, Zhu Y. Arterial compliance and its pressure-dependence in hypertension and vasodilation. Angiology J Vasc Dis. 1994;45:113–7. Li JK-J, Zhu Y. Arterial compliance and its pressure-dependence in hypertension and vasodilation. Angiology J Vasc Dis. 1994;45:113–7.
Zurück zum Zitat Li JK-J, Zhu Y, Drzewiecki G. Pulse pressure is a significant determinant of arterial compliance in hypertension and vasodilation. Circulation. 1994;90:I166. Li JK-J, Zhu Y, Drzewiecki G. Pulse pressure is a significant determinant of arterial compliance in hypertension and vasodilation. Circulation. 1994;90:I166.
Zurück zum Zitat Li JK-J, Zhu Y, O’Hara D, Khaw K. Allometric hemodynamic analysis of isolated systolic hypertension and aging. Cardiovasc Eng. 2007;7:135–9.CrossRefPubMed Li JK-J, Zhu Y, O’Hara D, Khaw K. Allometric hemodynamic analysis of isolated systolic hypertension and aging. Cardiovasc Eng. 2007;7:135–9.CrossRefPubMed
Zurück zum Zitat Liao J, Li JK-J. Modeling of the coronary circulatory system. Cardiovasc Eng. 2005;5:141–50.CrossRef Liao J, Li JK-J. Modeling of the coronary circulatory system. Cardiovasc Eng. 2005;5:141–50.CrossRef
Zurück zum Zitat Lucas CL, Wilcox BR, Henry GW. Comparison of time domain algorithms for estimating aortic characteristic impedance in humans. IEEE Trans Biomed Eng. 1988;35:62–7.CrossRefPubMed Lucas CL, Wilcox BR, Henry GW. Comparison of time domain algorithms for estimating aortic characteristic impedance in humans. IEEE Trans Biomed Eng. 1988;35:62–7.CrossRefPubMed
Zurück zum Zitat Matonick JP, Li JK-J. Pressure-dependent and frequency domain characteristics of systemic arterial compliance. Cardiovasc Eng. 2001;1:21–30.CrossRef Matonick JP, Li JK-J. Pressure-dependent and frequency domain characteristics of systemic arterial compliance. Cardiovasc Eng. 2001;1:21–30.CrossRef
Zurück zum Zitat Murgo JP, Westerhof N, Giolma JP, Altobelli S. Manipulation of ascending aorta pressure and flow wave reflections with the valsalva maneuver: relationship to input impedance. Circulation. 1981;63:122–32.PubMed Murgo JP, Westerhof N, Giolma JP, Altobelli S. Manipulation of ascending aorta pressure and flow wave reflections with the valsalva maneuver: relationship to input impedance. Circulation. 1981;63:122–32.PubMed
Zurück zum Zitat Noordergraaf A. Circulatory system dynamics. New York: Academic Press; 1978. Noordergraaf A. Circulatory system dynamics. New York: Academic Press; 1978.
Zurück zum Zitat Ohtsuka S, Kakihana M, Sugishita Y, Ito I. Effects on the rise in aortic pressure on coronary flow reserve in dogs. Jpn Heart J. 1987;28:403–11.PubMed Ohtsuka S, Kakihana M, Sugishita Y, Ito I. Effects on the rise in aortic pressure on coronary flow reserve in dogs. Jpn Heart J. 1987;28:403–11.PubMed
Zurück zum Zitat Pepine CJ, Nichols WW, Curry RC, Conti R. Aortic input impedance during nitroprusside infusion. J Clin Invest. 1979;64:643–54.CrossRefPubMed Pepine CJ, Nichols WW, Curry RC, Conti R. Aortic input impedance during nitroprusside infusion. J Clin Invest. 1979;64:643–54.CrossRefPubMed
Zurück zum Zitat Randall OS. Effect of arterial compliance on systolic blood pressure and cardiac function. Clin Exp Hypertens Theory Pract. 1982;4(7):1045–57.CrossRef Randall OS. Effect of arterial compliance on systolic blood pressure and cardiac function. Clin Exp Hypertens Theory Pract. 1982;4(7):1045–57.CrossRef
Zurück zum Zitat Safar ME, Laurent P. Pulse pressure and arterial stiffness in rats: comparison with humans. Am J Physiol. 2003;285:H1363–9. Safar ME, Laurent P. Pulse pressure and arterial stiffness in rats: comparison with humans. Am J Physiol. 2003;285:H1363–9.
Zurück zum Zitat Stergiopoulos N, Segers P, Westerhof N. Use of pulse pressure method for estimating total arterial compliance in vivo. Am J Physiol. 1999;276:H424–8. Stergiopoulos N, Segers P, Westerhof N. Use of pulse pressure method for estimating total arterial compliance in vivo. Am J Physiol. 1999;276:H424–8.
Zurück zum Zitat Stokland O, Miller MM, Ilebekk A, Kiil F. Mechanism of hemodynamic responses to occlusion of the descending thoracic aorta. Am J Physiol. 1980;238:H423–9.PubMed Stokland O, Miller MM, Ilebekk A, Kiil F. Mechanism of hemodynamic responses to occlusion of the descending thoracic aorta. Am J Physiol. 1980;238:H423–9.PubMed
Zurück zum Zitat Van den Bos GC, Westerhof N, Elzinga G, Sipkema P. Reflection in the systemic arterial arterial system effects of aortic and carotid occlusion. Cardiovasc Res. 1976;10:565–73.CrossRef Van den Bos GC, Westerhof N, Elzinga G, Sipkema P. Reflection in the systemic arterial arterial system effects of aortic and carotid occlusion. Cardiovasc Res. 1976;10:565–73.CrossRef
Zurück zum Zitat Vogt A, Neuhaus K-L, Kreuzer H. Pathophysiologic arguments for vasodilators in heart failure. Cardiovasc Drugs Ther. 1988;2:647–51.CrossRefPubMed Vogt A, Neuhaus K-L, Kreuzer H. Pathophysiologic arguments for vasodilators in heart failure. Cardiovasc Drugs Ther. 1988;2:647–51.CrossRefPubMed
Zurück zum Zitat Yin FCP, Guzman PA, Brin KP, Maughan WL, Brinker JA, Traill TA, Weiss JL, Weisfeldt ML. Effect of nitroprusside on hydraulic vascular loads on the right and left ventricle of patients with heart failure. Circulation. 1983;67:1330–9.PubMed Yin FCP, Guzman PA, Brin KP, Maughan WL, Brinker JA, Traill TA, Weiss JL, Weisfeldt ML. Effect of nitroprusside on hydraulic vascular loads on the right and left ventricle of patients with heart failure. Circulation. 1983;67:1330–9.PubMed
Zurück zum Zitat Zandberg P, Timmermans PBMWM, van Zwieten PA. Hemodynamic profiles of methoxamine and B-HT933 in spinalized ganglion-blocked dogs. J Cardiovasc Pharmacol. 1984;6:256–62.CrossRefPubMed Zandberg P, Timmermans PBMWM, van Zwieten PA. Hemodynamic profiles of methoxamine and B-HT933 in spinalized ganglion-blocked dogs. J Cardiovasc Pharmacol. 1984;6:256–62.CrossRefPubMed
Metadaten
Titel
Pulse Pressure, Arterial Compliance and Wave Reflection Under Differential Vasoactive and Mechanical Loading
verfasst von
John K-J. Li
Ying Zhu
Pamela S. Geipel
Publikationsdatum
01.12.2010
Verlag
Springer US
Erschienen in
Cardiovascular Engineering / Ausgabe 4/2010
Print ISSN: 1567-8822
Elektronische ISSN: 1573-6806
DOI
https://doi.org/10.1007/s10558-010-9107-y

Weitere Artikel der Ausgabe 4/2010

Cardiovascular Engineering 4/2010 Zur Ausgabe

Triglyzeridsenker schützt nicht nur Hochrisikopatienten

10.05.2024 Hypercholesterinämie Nachrichten

Patienten mit Arteriosklerose-bedingten kardiovaskulären Erkrankungen, die trotz Statineinnahme zu hohe Triglyzeridspiegel haben, profitieren von einer Behandlung mit Icosapent-Ethyl, und zwar unabhängig vom individuellen Risikoprofil.

Gibt es eine Wende bei den bioresorbierbaren Gefäßstützen?

In den USA ist erstmals eine bioresorbierbare Gefäßstütze – auch Scaffold genannt – zur Rekanalisation infrapoplitealer Arterien bei schwerer PAVK zugelassen worden. Das markiert einen Wendepunkt in der Geschichte dieser speziellen Gefäßstützen.

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.