Abstract

Computer-assisted total knee replacement (TKR) has been shown to improve radiographic alignment. Continuous feedback from the navigation system allows accurate adjustment of the bone cuts, thus reducing errors. The aim of this study was to determine the impact of experience both with computer navigation and knee replacement surgery on the frequency of errors in intraoperative bone cuts and implant alignment. Three homogeneous patient groups undergoing computer assisted TKR were included in the study. Each group was treated by one of three surgeons with varying experience in computer-aided and knee replacement surgery. Surgeon A had extensive experience in knee replacement and computer-assisted surgery. Surgeon B was an experienced knee replacement surgeon. A general orthopaedic surgeon with limited knee replacement surgery experience performed all surgeries in group C. The cutting errors and the number of re-cuts were determined intraoperatively. The complications and mean surgical time were collected for each group. The postoperative frontal femoral component angle, frontal tibial component angle, hip–knee–ankle angle and component slopes were evaluated. The results showed that the number of cutting errors were lowest for TKR performed by the surgeon with experience in navigation. This difference was statistically significant when compared to the general orthopaedic surgeon. A statistically significant superior result was achieved in final mechanical axis alignment for the surgeon experienced in computer-guided surgery compared to the other two groups (179.3° compared to 178.9° and 178.1°). However, the total number of outliers was similar, with no statistically significant differences among the three surgeons. Experience with navigation significantly reduced the surgical time.
Literatur
1.
Zurück zum Zitat Bathis H, Perlick L, Tingart M, Perlick C, Luring C, Grifka J (2005) Intraoperative cutting errors in total knee arthroplasty. Arch Orthop Trauma Surg 125(1):16–20CrossRefPubMed Bathis H, Perlick L, Tingart M, Perlick C, Luring C, Grifka J (2005) Intraoperative cutting errors in total knee arthroplasty. Arch Orthop Trauma Surg 125(1):16–20CrossRefPubMed
2.
Zurück zum Zitat Carter RE 3rd, Rush PF, Smid JA, Smith WL (2008) Experience with computer-assisted navigation for total knee arthroplasty in a community setting. J Arthroplasty 23(5):707–713CrossRefPubMed Carter RE 3rd, Rush PF, Smid JA, Smith WL (2008) Experience with computer-assisted navigation for total knee arthroplasty in a community setting. J Arthroplasty 23(5):707–713CrossRefPubMed
3.
Zurück zum Zitat Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626CrossRefPubMed Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626CrossRefPubMed
4.
Zurück zum Zitat Cobb JP, Kannan V, Brust K, Thevendran G (2007) Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res 463:90–97PubMed Cobb JP, Kannan V, Brust K, Thevendran G (2007) Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res 463:90–97PubMed
5.
Zurück zum Zitat Confalonieri N, Manzotti A, Pullen C, Ragone V (2005) Computer-assisted technique versus intramedullary and extramedullary alignment systems in total knee replacement: a radiological comparison. Acta Orthop Belg 71:703–709PubMed Confalonieri N, Manzotti A, Pullen C, Ragone V (2005) Computer-assisted technique versus intramedullary and extramedullary alignment systems in total knee replacement: a radiological comparison. Acta Orthop Belg 71:703–709PubMed
6.
Zurück zum Zitat Daubresse F, Vajeu C, Loquet R (2005) Total knee arthroplasty with conventional or navigated technique: comparison of the learning curves in a community hospital. Acta Orthop Belg 71(6):710–713PubMed Daubresse F, Vajeu C, Loquet R (2005) Total knee arthroplasty with conventional or navigated technique: comparison of the learning curves in a community hospital. Acta Orthop Belg 71(6):710–713PubMed
7.
Zurück zum Zitat Ek ET, Dowsey MM, Tse LF, Riazi A, Love BR, Stoney JD, Choong PF (2008) Comparison of functional and radiological outcomes after computer-assisted versus conventional total knee arthroplasty: a matched-control retrospective study. J Orthop Surg (Hong Kong) 16(2):192–196 Ek ET, Dowsey MM, Tse LF, Riazi A, Love BR, Stoney JD, Choong PF (2008) Comparison of functional and radiological outcomes after computer-assisted versus conventional total knee arthroplasty: a matched-control retrospective study. J Orthop Surg (Hong Kong) 16(2):192–196
8.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA, 5 (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed Jeffery RS, Morris RW, Denham RA, 5 (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed
9.
Zurück zum Zitat Jenny JY, Mielke RK, Giurea A (2008) Learning curve in navigated total knee replacement: A multi-centre study comparing experienced and beginner centers. Knee 15(2):80–84PubMed Jenny JY, Mielke RK, Giurea A (2008) Learning curve in navigated total knee replacement: A multi-centre study comparing experienced and beginner centers. Knee 15(2):80–84PubMed
10.
Zurück zum Zitat Lewold S, Knutson K, Lidgren L (1993) Reduced failure rate in knee prosthetic surgery with improved implantation technique. Clin Orthop Relat Res (287):94–97 Lewold S, Knutson K, Lidgren L (1993) Reduced failure rate in knee prosthetic surgery with improved implantation technique. Clin Orthop Relat Res (287):94–97
11.
Zurück zum Zitat Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 24(4):570–578 Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 24(4):570–578
12.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed
13.
Zurück zum Zitat Lüring C, Oczipka F, Perlick L, Tingart M, Grifka J, Bäthis H (2009) Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction. Knee Surg Sports Traumatol Arthrosc 17(3):228–232 Lüring C, Oczipka F, Perlick L, Tingart M, Grifka J, Bäthis H (2009) Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction. Knee Surg Sports Traumatol Arthrosc 17(3):228–232
14.
Zurück zum Zitat Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640CrossRefPubMed Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640CrossRefPubMed
15.
Zurück zum Zitat Manley M, Ong K, Lau E, Kurtz SM (2008) Total knee arthroplasty survivorship in the United States Medicare population effect of hospital and surgeon procedure volume. J Arthroplasty; Oct 31 [Epub ahead of print] Manley M, Ong K, Lau E, Kurtz SM (2008) Total knee arthroplasty survivorship in the United States Medicare population effect of hospital and surgeon procedure volume. J Arthroplasty; Oct 31 [Epub ahead of print]
16.
Zurück zum Zitat Otani T, Whiteside LA, White SE (1993) Cutting errors in preparation of femoral components in total knee arthroplasty. J Arthroplasty 8(5):503–510CrossRefPubMed Otani T, Whiteside LA, White SE (1993) Cutting errors in preparation of femoral components in total knee arthroplasty. J Arthroplasty 8(5):503–510CrossRefPubMed
17.
Zurück zum Zitat Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17(6):698–705CrossRefPubMed Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17(6):698–705CrossRefPubMed
18.
Zurück zum Zitat Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12(6):677–682CrossRefPubMed Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12(6):677–682CrossRefPubMed
19.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 153–156 Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 153–156
20.
Zurück zum Zitat Sampath SA, Voon SH, Sangster M, Davies H (2008) The statistical relationship between varus deformity, surgeon's experience, BMI and tourniquet time for computer assisted total knee replacements. Knee 16(2):121–124 Sampath SA, Voon SH, Sangster M, Davies H (2008) The statistical relationship between varus deformity, surgeon's experience, BMI and tourniquet time for computer assisted total knee replacements. Knee 16(2):121–124
21.
Zurück zum Zitat Santini AJ, Raut VT (2008) Ten-year survival analysis of the PFC total knee arthroplasty—a surgeon's first 99 replacements. Int Orthop 32(4):459–465CrossRefPubMed Santini AJ, Raut VT (2008) Ten-year survival analysis of the PFC total knee arthroplasty—a surgeon's first 99 replacements. Int Orthop 32(4):459–465CrossRefPubMed
22.
Zurück zum Zitat Seon JK, Park SJ, Lee KB, Li G, Kozanek M, Song EK (2008) Functional comparison of total knee arthroplasty performed with and without a navigation system. Int Orthop; Jun 28 [Epub ahead of print] Seon JK, Park SJ, Lee KB, Li G, Kozanek M, Song EK (2008) Functional comparison of total knee arthroplasty performed with and without a navigation system. Int Orthop; Jun 28 [Epub ahead of print]
23.
Zurück zum Zitat Slover JD, Tosteson AN, Bozic KJ, Rubash HE, Malchau H (2008) Impact of hospital volume on the economic value of computer navigation for total knee replacement. J Bone Joint Surg Am 90(7):1492–1500CrossRefPubMed Slover JD, Tosteson AN, Bozic KJ, Rubash HE, Malchau H (2008) Impact of hospital volume on the economic value of computer navigation for total knee replacement. J Bone Joint Surg Am 90(7):1492–1500CrossRefPubMed
24.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomized study. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomized study. J Bone Joint Surg Br 85:830–835PubMed
25.
Zurück zum Zitat Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP (2008) Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res 466(4):935–945CrossRefPubMed Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP (2008) Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res 466(4):935–945CrossRefPubMed
Metadaten
Titel
Relationship between cutting errors and learning curve in computer-assisted total knee replacement
verfasst von
Alfonso Manzotti
Pietro Cerveri
Elena De Momi
Chris Pullen
Norberto Confalonieri
Publikationsdatum
01.06.2010
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 5/2010
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0816-z

Weitere Artikel der Ausgabe 5/2010

International Orthopaedics 5/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.