Skip to main content
Erschienen in: European Spine Journal 4/2020

01.04.2020 | Review Article

Reliability and validity of lateral curvature assessments using clinical ultrasound for the patients with scoliosis: a systematic review

verfasst von: Hui-Dong Wu, Wei Liu, Man-Sang Wong

Erschienen in: European Spine Journal | Ausgabe 4/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Clinical ultrasound is radiation-free, low cost and user friendly, which makes it probable in assessment of scoliosis. Numerous studies have been conducted about the feasibility of using clinical ultrasound to assess scoliosis; thus, an inclusive review of the literature would be beneficial for researchers, clinicians and patients. This study aimed to systematically review the reliability and validity of coronal curvature assessments obtained from different clinical ultrasound imaging methods.

Methods

A comprehensive search of 6 databases and Google Scholar search engine was performed for retrieving articles assessing reliability and/or validity of spinal curvature measurements obtained from clinical ultrasound. Two reviewers assessed the methodological quality of selected articles independently using criteria appraisal instrument. The results were analysed and synthesized qualitatively using level of evidence method.

Results

Fourteen articles were included. Thirteen articles investigated both the reliability and validity, of which nine were of high quality; and one article evaluated only the reliability and was of high quality. Totally five ultrasound methods were evaluated. Very high reliability (intra-class correlation coefficient = 0.80–1.00) but limited levels of evidence were found for the majority of the studied ultrasound methods. Almost all the methods showed good to excellent validity (correlation coefficient = 0.76–1.00) but limited to moderate levels of evidence.

Conclusion

A high level of evidence was found in support of the reliability and validity of the COL (centre of lamina) ultrasound method. Further reliability and validity studies should be conducted to strengthen the level of evidence for those ultrasound methods with moderate, limited or conflicting level of evidence.

Graphic abstract

These slides can be retrieved under Electronic Supplementary Material.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
7.
Zurück zum Zitat Ronckers CM, Land CE, Miller JS, Stovall M, Lonstein JE, Doody MM (2010) Cancer mortality among women frequently exposed to radiographic examinations for spinal disorders. Radiat Res 174(1):83–90CrossRef Ronckers CM, Land CE, Miller JS, Stovall M, Lonstein JE, Doody MM (2010) Cancer mortality among women frequently exposed to radiographic examinations for spinal disorders. Radiat Res 174(1):83–90CrossRef
8.
Zurück zum Zitat Knott P, Pappo E, Cameron M, deMauroy JC, Rivard C, Kotwicki T, Zaina F, Wynne J, Stikeleather Luke, Bettany-Saltikov J, Grivas TB, Durmala J, Maruyama T, Negrini S, O’Brien JP, Rigo M (2014) SOSORT 2012 consensus paper: reducing x-ray exposure in pediatric patients with scoliosis. Scoliosis 9(1):4CrossRef Knott P, Pappo E, Cameron M, deMauroy JC, Rivard C, Kotwicki T, Zaina F, Wynne J, Stikeleather Luke, Bettany-Saltikov J, Grivas TB, Durmala J, Maruyama T, Negrini S, O’Brien JP, Rigo M (2014) SOSORT 2012 consensus paper: reducing x-ray exposure in pediatric patients with scoliosis. Scoliosis 9(1):4CrossRef
9.
Zurück zum Zitat Cheung CWJ, Law SY, Zheng YP Development of 3-D ultrasound system for assessment of adolescent idiopathic scoliosis (AIS): and system validation. In: 35th annual international conference of the IEEE EMBS, Osaka, Japan, 2013 Cheung CWJ, Law SY, Zheng YP Development of 3-D ultrasound system for assessment of adolescent idiopathic scoliosis (AIS): and system validation. In: 35th annual international conference of the IEEE EMBS, Osaka, Japan, 2013
13.
Zurück zum Zitat Zhou GQ, Zheng YP Assessment of scoliosis using 3-D ultrasound volume projection imaging with automatic spine curvature detection. In: IEEE international ultrasonics symposium, 2015 Zhou GQ, Zheng YP Assessment of scoliosis using 3-D ultrasound volume projection imaging with automatic spine curvature detection. In: IEEE international ultrasonics symposium, 2015
14.
Zurück zum Zitat Zhou GQ, Jiang WW, Lai KL, Zheng YP (2017) Automatic measurement of spine curvature on 3-D ultrasound volume projection image with phase features. IEEE T on Med Imaging 36(6):1250–1262CrossRef Zhou GQ, Jiang WW, Lai KL, Zheng YP (2017) Automatic measurement of spine curvature on 3-D ultrasound volume projection image with phase features. IEEE T on Med Imaging 36(6):1250–1262CrossRef
16.
Zurück zum Zitat Chen W, Lou E, Le LH (2015) A reliable semi-automatic program to measure the vertebral rotation using the center of lamina for adolescent idiopathic scoliosis. In: In: 5th international conference on biomedical engineering in Vietnam. IFMBE Proceedings, pp 159–162. https://doi.org/10.1007/978-3-319-11776-8_39 Chen W, Lou E, Le LH (2015) A reliable semi-automatic program to measure the vertebral rotation using the center of lamina for adolescent idiopathic scoliosis. In: In: 5th international conference on biomedical engineering in Vietnam. IFMBE Proceedings, pp 159–162. https://​doi.​org/​10.​1007/​978-3-319-11776-8_​39
17.
Zurück zum Zitat Cheung CWJ, Zhou GQ, Law SY, Mak TM, Lai KL, Zheng YP (2015) Ultrasound volume projection imaging for assessment of scoliosis. IEEE T Med Imaging 34(8):1760–1768CrossRef Cheung CWJ, Zhou GQ, Law SY, Mak TM, Lai KL, Zheng YP (2015) Ultrasound volume projection imaging for assessment of scoliosis. IEEE T Med Imaging 34(8):1760–1768CrossRef
19.
Zurück zum Zitat Li M, Ng B, Cheng J, Ying M, Zheng YP, Lam TP, Wong WY, Wong MS (2012) Could clinical ultrasound improve the fitting of spinal orthosis for the patients with AIS? Eur Spine J 21:1926–1935CrossRef Li M, Ng B, Cheng J, Ying M, Zheng YP, Lam TP, Wong WY, Wong MS (2012) Could clinical ultrasound improve the fitting of spinal orthosis for the patients with AIS? Eur Spine J 21:1926–1935CrossRef
20.
Zurück zum Zitat Zheng R, Young M, Hill D, Le LH, Hedden D, Moreau M, Mahood J, Southon S, Lou E (2016) Improvement on the accuracy and reliability of ultrasound coronal curvature measurement on adolescent idiopathic scoliosis with the aid of previous radiographs. Spine 41(5):404–411CrossRef Zheng R, Young M, Hill D, Le LH, Hedden D, Moreau M, Mahood J, Southon S, Lou E (2016) Improvement on the accuracy and reliability of ultrasound coronal curvature measurement on adolescent idiopathic scoliosis with the aid of previous radiographs. Spine 41(5):404–411CrossRef
25.
Zurück zum Zitat Zheng YP, Lee TTY, Lai KKL, Yip BHK, Zhou GQ, Jiang WW, Cheung JCW, Wong MS, Ng BKW, Cheng JCY, Lam TP (2016) A reliability and validity study for Scolioscan: a radiation-free scoliosis assessment system using 3D ultrasound imaging. Scoliosis 11:13CrossRef Zheng YP, Lee TTY, Lai KKL, Yip BHK, Zhou GQ, Jiang WW, Cheung JCW, Wong MS, Ng BKW, Cheng JCY, Lam TP (2016) A reliability and validity study for Scolioscan: a radiation-free scoliosis assessment system using 3D ultrasound imaging. Scoliosis 11:13CrossRef
26.
Zurück zum Zitat Wang Q, Li M, Lou EHM, Wong MS (2015) Reliability and validity study of clinical ultrasound imaging on lateral curvature of adolescent idiopathic scoliosis. PLoS ONE 10(8):e0135264CrossRef Wang Q, Li M, Lou EHM, Wong MS (2015) Reliability and validity study of clinical ultrasound imaging on lateral curvature of adolescent idiopathic scoliosis. PLoS ONE 10(8):e0135264CrossRef
28.
Zurück zum Zitat Cheung CWJ, Zhou GQ, Law SY, Lai KL, Jiang WW, Zheng YP (2015) Freehand three-dimensional ultrasound system for assessment of scoliosis. J Orthop Transl 3:123–133 Cheung CWJ, Zhou GQ, Law SY, Lai KL, Jiang WW, Zheng YP (2015) Freehand three-dimensional ultrasound system for assessment of scoliosis. J Orthop Transl 3:123–133
29.
Zurück zum Zitat Li M, Cheng J, Ying M, Ng B, Lam TP, Wong MS (2015) A preliminary study of estimation of Cobb’s angle from the spinous process angle using a clinical ultrasound method. Spine Deform 3:476–482CrossRef Li M, Cheng J, Ying M, Ng B, Lam TP, Wong MS (2015) A preliminary study of estimation of Cobb’s angle from the spinous process angle using a clinical ultrasound method. Spine Deform 3:476–482CrossRef
30.
Zurück zum Zitat Lohr K (2002) Assessing health status and quality-of-life instruments attributes and review criteria. Qual Life Res 11(3):193CrossRef Lohr K (2002) Assessing health status and quality-of-life instruments attributes and review criteria. Qual Life Res 11(3):193CrossRef
36.
Zurück zum Zitat van Tulder M, Furlan A, Bombardier C, Bouter L (2003) Updated method guidelines for systematic reviews in the cochrane collaboration back review Group. Spine 28(12):1290–1299PubMed van Tulder M, Furlan A, Bombardier C, Bouter L (2003) Updated method guidelines for systematic reviews in the cochrane collaboration back review Group. Spine 28(12):1290–1299PubMed
37.
Zurück zum Zitat Currier DP (1984) Elements of research in physical therapy, 3rd edn. William and Wikins, Baltimore Currier DP (1984) Elements of research in physical therapy, 3rd edn. William and Wikins, Baltimore
38.
Zurück zum Zitat Dawson B, Trapp RG (2004) Basic and clinical biostatistics, 4th edn. Lange Medical Books/McGraw-Hill, New York Dawson B, Trapp RG (2004) Basic and clinical biostatistics, 4th edn. Lange Medical Books/McGraw-Hill, New York
43.
Zurück zum Zitat Brink Y, Louw Q (2012) Clinical instruments: reliability and validity critical appraisal. J Eval Clin Pract 18:1126–1132CrossRef Brink Y, Louw Q (2012) Clinical instruments: reliability and validity critical appraisal. J Eval Clin Pract 18:1126–1132CrossRef
45.
Zurück zum Zitat Hui SC, Pialasse JP, Wong JY, Lam TP, Ng BK, Cheng JC, Chu WC (2016) Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research. Scoli Spinal Disord 11:46. https://doi.org/10.1186/s13013-016-0106-7 CrossRef Hui SC, Pialasse JP, Wong JY, Lam TP, Ng BK, Cheng JC, Chu WC (2016) Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research. Scoli Spinal Disord 11:46. https://​doi.​org/​10.​1186/​s13013-016-0106-7 CrossRef
46.
Zurück zum Zitat Frerich JM, Hertzler K, Knott P, Mardjetko S (2012) Comparison of radiographic and surface topography measurements in adolescents with idiopathic scoliosis. Open Ortho J 6:261–265CrossRef Frerich JM, Hertzler K, Knott P, Mardjetko S (2012) Comparison of radiographic and surface topography measurements in adolescents with idiopathic scoliosis. Open Ortho J 6:261–265CrossRef
Metadaten
Titel
Reliability and validity of lateral curvature assessments using clinical ultrasound for the patients with scoliosis: a systematic review
verfasst von
Hui-Dong Wu
Wei Liu
Man-Sang Wong
Publikationsdatum
01.04.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 4/2020
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-019-06280-y

Weitere Artikel der Ausgabe 4/2020

European Spine Journal 4/2020 Zur Ausgabe

Editorial

Editorial

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.