Skip to main content
Erschienen in: Rheumatology International 1/2011

01.01.2011 | Original Article

Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

verfasst von: Elizabeth A. Sled, Lisa M. Sheehy, David T. Felson, Patrick A. Costigan, Miu Lam, T. Derek V. Cooke

Erschienen in: Rheumatology International | Ausgabe 1/2011

Einloggen, um Zugang zu erhalten

Abstract

The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. (1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. (2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977–0.999 for computer analysis; 0.820–0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839–0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers.
Literatur
1.
Zurück zum Zitat Cerejo R, Dunlop DD, Cahue S, Channin D, Song J, Sharma L (2002) The influence of alignment on risk of knee osteoarthritis progression according to baseline stage of disease. Arthritis Rheum 46:2632–2636CrossRefPubMed Cerejo R, Dunlop DD, Cahue S, Channin D, Song J, Sharma L (2002) The influence of alignment on risk of knee osteoarthritis progression according to baseline stage of disease. Arthritis Rheum 46:2632–2636CrossRefPubMed
2.
Zurück zum Zitat Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286:188–195CrossRefPubMed Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286:188–195CrossRefPubMed
3.
Zurück zum Zitat Cooke TD, Li J, Scudamore RA (1994) Radiographic assessment of bony contributions to knee deformity. Orthop Clin North Am 25:387–393PubMed Cooke TD, Li J, Scudamore RA (1994) Radiographic assessment of bony contributions to knee deformity. Orthop Clin North Am 25:387–393PubMed
4.
Zurück zum Zitat Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227PubMed Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227PubMed
5.
Zurück zum Zitat Tetsworth K, Paley D (1994) Malalignment and degenerative arthropathy. Orthop Clin North Am 25:367–377PubMed Tetsworth K, Paley D (1994) Malalignment and degenerative arthropathy. Orthop Clin North Am 25:367–377PubMed
6.
Zurück zum Zitat Issa SN, Dunlop D, Chang A et al (2007) Full-limb and knee radiography assessments of varus–valgus alignment and their relationship to osteoarthritis disease features by magnetic resonance imaging. Arthritis Rheum 57:398–406CrossRefPubMed Issa SN, Dunlop D, Chang A et al (2007) Full-limb and knee radiography assessments of varus–valgus alignment and their relationship to osteoarthritis disease features by magnetic resonance imaging. Arthritis Rheum 57:398–406CrossRefPubMed
7.
Zurück zum Zitat Cooke TD, Sled EA, Scudamore RA (2007) Frontal plane knee alignment: a call for standardized measurement. J Rheumatol 34:1796–1801PubMed Cooke TD, Sled EA, Scudamore RA (2007) Frontal plane knee alignment: a call for standardized measurement. J Rheumatol 34:1796–1801PubMed
8.
Zurück zum Zitat Cooke TDV, Scudamore A (2003) Healthy knee alignment and mechanics. In: Callaghan JJ, Rosenberg AG, Rubash HE, Simonian PT, Wickiewicz TL (eds) The adult knee. Williams & Wilkins, Philadelphia, pp 175–186 Cooke TDV, Scudamore A (2003) Healthy knee alignment and mechanics. In: Callaghan JJ, Rosenberg AG, Rubash HE, Simonian PT, Wickiewicz TL (eds) The adult knee. Williams & Wilkins, Philadelphia, pp 175–186
9.
Zurück zum Zitat Chao EY, Neluheni EV, Hsu RW, Paley D (1994) Biomechanics of malalignment. Orthop Clin North Am 25:379–386PubMed Chao EY, Neluheni EV, Hsu RW, Paley D (1994) Biomechanics of malalignment. Orthop Clin North Am 25:379–386PubMed
10.
Zurück zum Zitat Cooke TD, Scudamore RA, Bryant JT, Sorbie C, Siu D, Fisher B (1991) A quantitative approach to radiography of the lower limb: principles and applications. J Bone Joint Surg Br 73:715–720PubMed Cooke TD, Scudamore RA, Bryant JT, Sorbie C, Siu D, Fisher B (1991) A quantitative approach to radiography of the lower limb: principles and applications. J Bone Joint Surg Br 73:715–720PubMed
11.
Zurück zum Zitat Prakash U, Wigderowitz CA, McGurty DW, Rowley DI (2001) Computerised measurement of tibiofemoral alignment. J Bone Joint Surg Br 83:819–824CrossRefPubMed Prakash U, Wigderowitz CA, McGurty DW, Rowley DI (2001) Computerised measurement of tibiofemoral alignment. J Bone Joint Surg Br 83:819–824CrossRefPubMed
12.
Zurück zum Zitat Sled E, Costigan P, Cooke TDV, Sheehy L, Hundt H, Qiu M (2005) Measuring malalignment in knee OA [abstract]. Osteoarthritis Cartilage 13:S120 Sled E, Costigan P, Cooke TDV, Sheehy L, Hundt H, Qiu M (2005) Measuring malalignment in knee OA [abstract]. Osteoarthritis Cartilage 13:S120
13.
Zurück zum Zitat Hankemeier S, Gosling T, Richter M, Hufner T, Hochhausen C, Krettek C (2006) Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method. Comput Aided Surg 11:81–86CrossRefPubMed Hankemeier S, Gosling T, Richter M, Hufner T, Hochhausen C, Krettek C (2006) Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method. Comput Aided Surg 11:81–86CrossRefPubMed
14.
Zurück zum Zitat Rozzanigo U, Pizzoli A, Minari C, Caudana R (2005) Alignment and articular orientation of lower limbs: manual vs computer-aided measurements on digital radiograms. Radiol Med 109:234–238PubMed Rozzanigo U, Pizzoli A, Minari C, Caudana R (2005) Alignment and articular orientation of lower limbs: manual vs computer-aided measurements on digital radiograms. Radiol Med 109:234–238PubMed
15.
Zurück zum Zitat Specogna AV, Birmingham TB, DaSilva JJ et al (2004) Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 17:203–210PubMed Specogna AV, Birmingham TB, DaSilva JJ et al (2004) Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 17:203–210PubMed
16.
Zurück zum Zitat Takahashi T, Yamanaka N, Komatsu M, Ogawa Y, Yoshida S, Yamamoto H (2004) A new computer-assisted method for measuring the tibio-femoral angle in patients with osteoarthritis of the knee. Osteoarthritis Cartilage 12:256–259CrossRefPubMed Takahashi T, Yamanaka N, Komatsu M, Ogawa Y, Yoshida S, Yamamoto H (2004) A new computer-assisted method for measuring the tibio-femoral angle in patients with osteoarthritis of the knee. Osteoarthritis Cartilage 12:256–259CrossRefPubMed
17.
Zurück zum Zitat Sailer J, Scharitzer M, Peloschek P, Giurea A, Imhof H, Grampp S (2005) Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs. Eur Radiol 15:170–173CrossRefPubMed Sailer J, Scharitzer M, Peloschek P, Giurea A, Imhof H, Grampp S (2005) Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs. Eur Radiol 15:170–173CrossRefPubMed
18.
Zurück zum Zitat Sanfridsson J, Ryd L, Eklund K, Kouvaras Y, Jonsson K (1996) Angular configuration of the knee: comparison of conventional measurements and the QUESTOR Precision Radiography System. Acta Radiol 37:633–638CrossRefPubMed Sanfridsson J, Ryd L, Eklund K, Kouvaras Y, Jonsson K (1996) Angular configuration of the knee: comparison of conventional measurements and the QUESTOR Precision Radiography System. Acta Radiol 37:633–638CrossRefPubMed
19.
Zurück zum Zitat Yoshioka Y, Siu D, Cooke TD (1987) The anatomy and functional axes of the femur. J Bone Joint Surg Am 69:873–880PubMed Yoshioka Y, Siu D, Cooke TD (1987) The anatomy and functional axes of the femur. J Bone Joint Surg Am 69:873–880PubMed
20.
Zurück zum Zitat Yoshioka Y, Siu DW, Scudamore RA, Cooke TD (1989) Tibial anatomy and functional axes. J Orthop Res 7:132–137CrossRefPubMed Yoshioka Y, Siu DW, Scudamore RA, Cooke TD (1989) Tibial anatomy and functional axes. J Orthop Res 7:132–137CrossRefPubMed
21.
Zurück zum Zitat Paley D (2003) Principles of deformity correction. Springer, New York Paley D (2003) Principles of deformity correction. Springer, New York
Metadaten
Titel
Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program
verfasst von
Elizabeth A. Sled
Lisa M. Sheehy
David T. Felson
Patrick A. Costigan
Miu Lam
T. Derek V. Cooke
Publikationsdatum
01.01.2011
Verlag
Springer-Verlag
Erschienen in
Rheumatology International / Ausgabe 1/2011
Print ISSN: 0172-8172
Elektronische ISSN: 1437-160X
DOI
https://doi.org/10.1007/s00296-009-1236-5

Weitere Artikel der Ausgabe 1/2011

Rheumatology International 1/2011 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.