Skip to main content
Erschienen in: European Journal of Pediatrics 1/2022

29.06.2021 | Short Communication

Repeatability of PDA diameter measurements on echocardiography

verfasst von: Kunal Babla, Donovan Duffy, Ramona Dumitru, Justin Richards, Anay Kulkarni

Erschienen in: European Journal of Pediatrics | Ausgabe 1/2022

Einloggen, um Zugang zu erhalten

Abstract

Diameter of the patent ductus arteriosus (PDA) on transthoracic echocardiography (TTE) is used as a marker of haemodynamic significance. We aimed to assess the intra- and inter-observer variability in PDA diameter in babies born at ≤ 30 weeks’ gestation. TTEs for 56 infants were performed by a single neonatologist. Cineloops were stored without measurement annotations. PDAs were measured on 2-dimensional (2D) and Colour Doppler. A second, blinded neonatologist repeated measurements on the same cineloops. The scanning neonatologist repeated measurements at a later date, blinded to original measurements. Inter-observer results showed repeatability coefficients of 1.57 (2D) and 2.18 (Colour), and repeatability index of 73% (2D) and 91% (Colour). Intra-observer results showed repeatability coefficients of 0.99 (2D) and 1.32 (Colour), and repeatability index of 43% (2D) and 49% (Colour).
Conclusion: There is significant inter- and intra-observer variability in measurements of PDA diameter, even on the same cineloops. We advise caution when using diameter alone as a marker of haemodynamic significance, and recommend using multiple parameters to determine haemodynamic significance of PDA.
What is Known:
• PDA is associated with numerous comorbidities such as bronchopulmonary dysplasia, necrotising enterocolitis, intraventricular haemorrhage and mortality.
• PDA diameter is commonly measured on transthoracic echocardiography and used as a marker of haemodynamic significance.
• A previous, smaller study has shown there may be poor repeatability of PDA diameter measurements in serial echocardiograms.
What is New:
• There is significant inter-observer variability in 2D and Colour Doppler measurements of PDA internal diameter on TTE in preterm infants.
• There is moderate intra-observer correlation of repeated measurements on the same imaging in both 2D and Colour Doppler imaging.
Literatur
1.
Zurück zum Zitat Hamrick SE, Hansmann G (2010) Patent ductus arteriosus of the preterm infant. Pediatrics 125(5):1020–1030CrossRef Hamrick SE, Hansmann G (2010) Patent ductus arteriosus of the preterm infant. Pediatrics 125(5):1020–1030CrossRef
2.
Zurück zum Zitat Laere D Van, Overmeire B Van, Gupta S, Khuffash E, Savoia M, Mcnamara PJ (2018) Application of NPE in the assessment of a patent ductus arteriosus Laere D Van, Overmeire B Van, Gupta S, Khuffash E, Savoia M, Mcnamara PJ (2018) Application of NPE in the assessment of a patent ductus arteriosus
3.
Zurück zum Zitat Kluckow M, Evans N (1995) Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilation. J Pediatr Kluckow M, Evans N (1995) Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilation. J Pediatr
4.
Zurück zum Zitat Hundscheid T, Onland W, van Overmeire B, Dijk P, van Kaam AHLC, Dijkman KP et al (2018) Early treatment versus expectative management of patent ductus arteriosus in preterm infants: a multicentre, randomised, non-inferiority trial in Europe (BeNeDuctus trial). BMC Pediatr. BMC Pediatrics 18(1):1–14 Hundscheid T, Onland W, van Overmeire B, Dijk P, van Kaam AHLC, Dijkman KP et al (2018) Early treatment versus expectative management of patent ductus arteriosus in preterm infants: a multicentre, randomised, non-inferiority trial in Europe (BeNeDuctus trial). BMC Pediatr. BMC Pediatrics 18(1):1–14
6.
Zurück zum Zitat Schwarz CE, Preusche A, Baden W, Poets CF, Franz AR (2016) Repeatability of echocardiographic parameters to evaluate the hemodynamic relevance of patent ductus arteriosus in preterm infants : a prospective observational study. BMC Pediatr [Internet]. BMC Pediatrics 16(18):1–5. Available from: https://doi.org/10.1186/s12887-016-0552-7 Schwarz CE, Preusche A, Baden W, Poets CF, Franz AR (2016) Repeatability of echocardiographic parameters to evaluate the hemodynamic relevance of patent ductus arteriosus in preterm infants : a prospective observational study. BMC Pediatr [Internet]. BMC Pediatrics 16(18):1–5. Available from: https://​doi.​org/​10.​1186/​s12887-016-0552-7
7.
Zurück zum Zitat Evans N, Iyer P (1995) Longitudinal changes in the diameter of the ductus arteriosus in ventilated preterm infants: correlation with respiratory outcomes. Arch Dis Child Fetal Neonatal Ed 72(3):F156–F161CrossRef Evans N, Iyer P (1995) Longitudinal changes in the diameter of the ductus arteriosus in ventilated preterm infants: correlation with respiratory outcomes. Arch Dis Child Fetal Neonatal Ed 72(3):F156–F161CrossRef
8.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 307–10 Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 307–10
Metadaten
Titel
Repeatability of PDA diameter measurements on echocardiography
verfasst von
Kunal Babla
Donovan Duffy
Ramona Dumitru
Justin Richards
Anay Kulkarni
Publikationsdatum
29.06.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Pediatrics / Ausgabe 1/2022
Print ISSN: 0340-6199
Elektronische ISSN: 1432-1076
DOI
https://doi.org/10.1007/s00431-021-04178-w

Weitere Artikel der Ausgabe 1/2022

European Journal of Pediatrics 1/2022 Zur Ausgabe

Klimaschutz beginnt bei der Wahl des Inhalators

14.05.2024 Klimawandel Podcast

Auch kleine Entscheidungen im Alltag einer Praxis können einen großen Beitrag zum Klimaschutz leisten. Die neue Leitlinie zur "klimabewussten Verordnung von Inhalativa" geht mit gutem Beispiel voran, denn der Wechsel vom klimaschädlichen Dosieraerosol zum Pulverinhalator spart viele Tonnen CO2. Leitlinienautor PD Dr. Guido Schmiemann erklärt, warum nicht nur die Umwelt, sondern auch Patientinnen und Patienten davon profitieren.

Zeitschrift für Allgemeinmedizin, DEGAM

Embryotransfer erhöht womöglich Leukämierisiko der Kinder

13.05.2024 Assistierte Reproduktion Nachrichten

Reproduktionsmedizinische Techniken haben theoretisch das Potenzial, den epigenetischen Code zu verändern und somit das Krebsrisiko der Kinder zu erhöhen. Zwischen Embryotransfer und Leukämie scheint sich ein solcher Zusammenhang bestätigt zu haben.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Pädiatrie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.