Skip to main content
Erschienen in: Journal of Digital Imaging 1/2004

01.03.2004

Review of Technology: Planning for the Development of Telesonography

verfasst von: Matthew J. Bassignani, M.D., Samuel J. Dwyer III, Ph.D., Jonathan M. Ciambotti, M.D., Juan M Olazagasti, M.D., Ruth Moran, M.D., Sean Moynihan, B.S., Alfred C. Weaver, Ph.D., Andrew M. Snyder, M.S.

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 1/2004

Einloggen, um Zugang zu erhalten

Abstract

Teleradiology allows contemporaneous interpretation of imaging exams performed at some distance from the interpreting radiologist. The transmitted images are usually static. However, there is benefit to real-time review of full-motion ultrasound (US) exams as they are performed. Telesonography is transmission of full-motion sonographic data to a remote site. We hypothesize that US exams, read after having been compressed utilizing Motion Picture Experts Group version 4 (MPEG-4) compression scheme, transmitted over the Internet as streaming multimedia, decompressed, and displayed, are equivalent in diagnostic accuracy to reading the examinations locally. MPEG-4 uses variable compression on each image frame to achieve a constant output bit rate. With less compression, the bit rate rises, and the only way the encoder can contain bit rate within the set bandwidth is by lowering frame rate or reducing image quality. We review the relevant technologies and industry standard components that will enable low-cost telesonography.
Literatur
1.
Zurück zum Zitat Landwehr, JB,Jr, Zador, IE, Wolfe, HM, et al. 1997Telemedicine and fetal ultrasonography: assessment of technical performance and clinical feasibility.Am J Obstet Gynecol177846848PubMed Landwehr, JB,Jr, Zador, IE, Wolfe, HM,  et al. 1997Telemedicine and fetal ultrasonography: assessment of technical performance and clinical feasibility.Am J Obstet Gynecol177846848PubMed
2.
Zurück zum Zitat Macedonia, CR 1998Three-dimensional ultrasonographic telepresence.J Telemed Telecare4224230CrossRefPubMed Macedonia, CR 1998Three-dimensional ultrasonographic telepresence.J Telemed Telecare4224230CrossRefPubMed
3.
Zurück zum Zitat Ratib, O, Ligier, Y, Brandon, D, et al. 2000Update on digital image management and PACS.Abdom Imaging25333340CrossRefPubMed Ratib, O, Ligier, Y, Brandon, D,  et al. 2000Update on digital image management and PACS.Abdom Imaging25333340CrossRefPubMed
4.
Zurück zum Zitat Hwang, SC, Lee, MH 2000A WEB-based telePACS using an asymmetric satellite system.IEEE Trans Inf Technol Biomed4212215CrossRefPubMed Hwang, SC, Lee, MH 2000A WEB-based telePACS using an asymmetric satellite system.IEEE Trans Inf Technol Biomed4212215CrossRefPubMed
5.
Zurück zum Zitat Mathiesen, FK 2001WEB technology—the future of teleradiology?Comput Meth Programs Biomed668790CrossRef Mathiesen, FK 2001WEB technology—the future of teleradiology?Comput Meth Programs Biomed668790CrossRef
7.
Zurück zum Zitat Kinosada, Y, Takada, A, Hosoba, M 2001Real-time radiology—new concepts for teleradiology.Comput Meth Programs Biomed664754CrossRef Kinosada, Y, Takada, A, Hosoba, M 2001Real-time radiology—new concepts for teleradiology.Comput Meth Programs Biomed664754CrossRef
8.
Zurück zum Zitat American College of Radiology ACR Appropriateness Criteria 2000. Radiology 215 Suppl: 1-1511, 2000 American College of Radiology ACR Appropriateness Criteria 2000. Radiology 215 Suppl: 1-1511, 2000
9.
Zurück zum Zitat Shea, JA, Berlin, JA, Escarce, JJ, et al. 1994Revised estimates of diagnostic test sensitivity and specificity in suspected biliary tract disease.Arch Intern Med15425732581CrossRefPubMed Shea, JA, Berlin, JA, Escarce, JJ,  et al. 1994Revised estimates of diagnostic test sensitivity and specificity in suspected biliary tract disease.Arch Intern Med15425732581CrossRefPubMed
10.
Zurück zum Zitat O’Neill, WC 2000Sonographic evaluation of renal failure.Am J Kidney Dis3510211038PubMed O’Neill, WC 2000Sonographic evaluation of renal failure.Am J Kidney Dis3510211038PubMed
11.
Zurück zum Zitat Laing, FC, Brown, DL, DiSalvo, DN 2001Gynecologic ultrasound.Radiol Clin North Am39523540PubMed Laing, FC, Brown, DL, DiSalvo, DN 2001Gynecologic ultrasound.Radiol Clin North Am39523540PubMed
12.
Zurück zum Zitat Chan, V, Hanbidge, A, Wilson, S, et al. 1996Case for active physician involvement in US practice.Radiology199555560PubMed Chan, V, Hanbidge, A, Wilson, S,  et al. 1996Case for active physician involvement in US practice.Radiology199555560PubMed
13.
Zurück zum Zitat Beard, DV, Hemminger, BM, Keefe, B, et al. 1993Real-time radiologist review of remote ultrasound using low-cost video and voice.Invest Radiol28732734PubMed Beard, DV, Hemminger, BM, Keefe, B,  et al. 1993Real-time radiologist review of remote ultrasound using low-cost video and voice.Invest Radiol28732734PubMed
14.
Zurück zum Zitat Falconer, J, Giles, W, Villanueva, H 1997Realtime ultrasound diagnosis over a wide-area network (WAN) using off-the-shelf components.J Telemed Telecare32830CrossRefPubMed Falconer, J, Giles, W, Villanueva, H 1997Realtime ultrasound diagnosis over a wide-area network (WAN) using off-the-shelf components.J Telemed Telecare32830CrossRefPubMed
15.
Zurück zum Zitat Duerinckx, AJ, Hayrapetian, A, Melany, M, et al. 1997Real-time sonographic video transfer using asynchronous transfer mode technology.AJR Am J Roentgenol16813531355PubMed Duerinckx, AJ, Hayrapetian, A, Melany, M,  et al. 1997Real-time sonographic video transfer using asynchronous transfer mode technology.AJR Am J Roentgenol16813531355PubMed
16.
Zurück zum Zitat Tanenbaum, AS 1996Computer Networks.3Prentice HallEnglewood Cliffs, NJ6772 Tanenbaum, AS 1996Computer Networks.3Prentice HallEnglewood Cliffs, NJ6772
17.
Zurück zum Zitat Fritz, SL 1999DICOM standardization.Siegel, ELKolodner, RM eds. Filmless Radiology.SpringerNew York311321 Fritz, SL 1999DICOM standardization.Siegel, ELKolodner, RM eds. Filmless Radiology.SpringerNew York311321
18.
Zurück zum Zitat Oosterwijk, H 2000DICOM Basics.O’Tech Inc.Crossroads, TX Oosterwijk, H 2000DICOM Basics.O’Tech Inc.Crossroads, TX
19.
Zurück zum Zitat Chanbari, M 2000Video coding.Short Run Press LtdExeter Chanbari, M 2000Video coding.Short Run Press LtdExeter
20.
Zurück zum Zitat Wallace, GK 1991The JPEG still picture compression standard.Commun ACM343044CrossRef Wallace, GK 1991The JPEG still picture compression standard.Commun ACM343044CrossRef
21.
Zurück zum Zitat MPEG-1 (Coding of moving pictures and associated audio for digital storage media at up to 1.5 Mbit/s) ISO/IEC 1117-1122, video, November 1991 MPEG-1 (Coding of moving pictures and associated audio for digital storage media at up to 1.5 Mbit/s) ISO/IEC 1117-1122, video, November 1991
22.
Zurück zum Zitat Haskel, BG, Puri, A, Netravali, AN 1997Digital video: an introduction to MPEG-2Chapman and HallNew York Haskel, BG, Puri, A, Netravali, AN 1997Digital video: an introduction to MPEG-2Chapman and HallNew York
23.
Zurück zum Zitat Koener, R, Perera, F, Chiariglione, L 1997MPEG-4: context and objectives.Image Commun J94 Koener, R, Perera, F, Chiariglione, L 1997MPEG-4: context and objectives.Image Commun J94
24.
Zurück zum Zitat Pennebaker, WH, Mitchell, JL 1993JPEG: still image compression standard.Van Nostrand ReinholdNew York Pennebaker, WH, Mitchell, JL 1993JPEG: still image compression standard.Van Nostrand ReinholdNew York
26.
Zurück zum Zitat DeAngelis, GA, Dempsey, BJ, Berr, S, et al. 1997Diagnostic efficacy of compressed digitized real-time sonography of uterine fibroids.Acad Radiol48389PubMed DeAngelis, GA, Dempsey, BJ, Berr, S,  et al. 1997Diagnostic efficacy of compressed digitized real-time sonography of uterine fibroids.Acad Radiol48389PubMed
27.
Zurück zum Zitat DeAngelis, GA, Dempsey, BJ, Berr, S, et al. 1995Digitized real-time ultrasound: signal compression experiment.Radiology197336 DeAngelis, GA, Dempsey, BJ, Berr, S,  et al. 1995Digitized real-time ultrasound: signal compression experiment.Radiology197336
28.
Zurück zum Zitat Sublett, JW, Dempsey, BJ, Weaver, AC 1995Design and implementation of a digital teleultrasound system for real-time remote diagnosis, computer-based medical systems.IEEE Computer Society PressLos Alamitos, CA292228 Sublett, JW, Dempsey, BJ, Weaver, AC 1995Design and implementation of a digital teleultrasound system for real-time remote diagnosis, computer-based medical systems.IEEE Computer Society PressLos Alamitos, CA292228
29.
Zurück zum Zitat Sublett J: Design of a Teleultrasound System, Master’s thesis, University of Virginia, May 1996 Sublett J: Design of a Teleultrasound System, Master’s thesis, University of Virginia, May 1996
30.
Zurück zum Zitat Bubash–Faust LB, Bassignani MJ: A Comparison between Diagnostic Quality Digitizer and Flat Bed Scanner with Transparency Adapter for the Creation of Digital Teaching Files. Society for Health Services Research in Radiology Annual Meeting, San Diego, CA, October 18-20, 2001 Bubash–Faust LB, Bassignani MJ: A Comparison between Diagnostic Quality Digitizer and Flat Bed Scanner with Transparency Adapter for the Creation of Digital Teaching Files. Society for Health Services Research in Radiology Annual Meeting, San Diego, CA, October 18-20, 2001
31.
Zurück zum Zitat Weaver AC, Viswanathan A, Gay S, et al: Teleultasound. RSNA, December 1996 Weaver AC, Viswanathan A, Gay S, et al: Teleultasound. RSNA, December 1996
32.
Zurück zum Zitat Weaver AC, Dwyer SJ, Rheuban K: An exploration of streaming multimedia for pediatric cardiology. Fund for Exploration of Science and Technology, University of Virginia, March 2001 Weaver AC, Dwyer SJ, Rheuban K: An exploration of streaming multimedia for pediatric cardiology. Fund for Exploration of Science and Technology, University of Virginia, March 2001
33.
Zurück zum Zitat Swets, JA, Pickett, RM 1982Evaluation of diagnostic systems, methods from signal detection theory.Academic PressNew York8093 Swets, JA, Pickett, RM 1982Evaluation of diagnostic systems, methods from signal detection theory.Academic PressNew York8093
34.
Zurück zum Zitat Hanley, JA, McNeil, BJ 1982The meaning and use of the area under a receiver operating characteristic (ROC) curve.Radiology1432936PubMed Hanley, JA, McNeil, BJ 1982The meaning and use of the area under a receiver operating characteristic (ROC) curve.Radiology1432936PubMed
35.
Zurück zum Zitat Hanley, JA, McNeil, BJ 1983A method of comparing the areas under receiving operating characteristic curves from the same cases.Radiology148839843PubMed Hanley, JA, McNeil, BJ 1983A method of comparing the areas under receiving operating characteristic curves from the same cases.Radiology148839843PubMed
36.
Zurück zum Zitat Barnett, SB, Rott, HD, ter Haar, GR, et al. 1997The sensitivity of biological tissue to ultrasound.Ultrasound Med Biol23805812CrossRefPubMed Barnett, SB, Rott, HD, ter Haar, GR,  et al. 1997The sensitivity of biological tissue to ultrasound.Ultrasound Med Biol23805812CrossRefPubMed
37.
Zurück zum Zitat American Institute of Ultrasound in Medicine. Bioeffects Committee1988Bioeffects considerations for the safety of diagnostic ultrasound.J Ultrasound Med7S138 American Institute of Ultrasound in Medicine. Bioeffects Committee1988Bioeffects considerations for the safety of diagnostic ultrasound.J Ultrasound Med7S138
Metadaten
Titel
Review of Technology: Planning for the Development of Telesonography
verfasst von
Matthew J. Bassignani, M.D.
Samuel J. Dwyer III, Ph.D.
Jonathan M. Ciambotti, M.D.
Juan M Olazagasti, M.D.
Ruth Moran, M.D.
Sean Moynihan, B.S.
Alfred C. Weaver, Ph.D.
Andrew M. Snyder, M.S.
Publikationsdatum
01.03.2004
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 1/2004
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-003-1721-4

Weitere Artikel der Ausgabe 1/2004

Journal of Digital Imaging 1/2004 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.