Abstract

Removal of foreign bodies from soft tissues in emergency is very challenging and becomes more problematic when it is radiolucent. Blind exploration is sometimes hazardous for patients especially when it is in proximity to a vessel or a nerve or an overlying tendon. The purpose of this study was to determine the accuracy of ultrasonography (USG) in detecting radiolucent soft tissue foreign bodies in the extremities. From January 2014 to January 2016, 120 patients with either a positive history or clinically suspected soft tissue foreign body and negative radiography were evaluated by USG with a high-frequency (13–6 MHz) linear-array transducer. The sonographic findings were used to guide surgical exploration. Out of 120 patients who underwent surgical exploration, USG was positive in 114 cases, and foreign body was retrieved in 108 cases, and among the six cases where USG was negative, foreign body was retrieved from one case. In one case with strong clinical suspicion of foreign body USG was falsely negative. Majority of foreign bodies were removed from foot (69 cases) and hands (26 cases), and rest of foreign bodies were removed from ankle (4 cases), wrist (3 cases), thigh (2 cases), leg (1 case), knee (2 cases), forearm (2 cases). Accuracy, sensitivity, and positive predictive value were determined as 94.16, 99.08, and 94.13%, respectively. The real-time high-frequency USG is a highly sensitive and accurate tool for detecting and removing radiolucent foreign bodies which cannot be visualized by routine radiography.

Background

Penetrating foreign bodies are common in patients visiting emergency departments [1, 2]. Farming being the most common job among the population in Kashmir with practice of working bare footed in orchards, the probability of penetration of tree splinters as a radiolucent foreign body in the extremities, especially the sole of the foot, is high. The missed foreign body may remain asymptomatic for prolonged periods or else lead to a wide range of complications including pain, abscess, chronic discharging wound, necrotizing fasciitis bone and joint destructive lesions granulomas with impairment of tendon mobility or triggering of digits migration delayed tendon ruptures, neurodeficits, pyogenic granulomas, vascular events, massive soft tissue injury, and lawsuits [315].
A radiolucent foreign body such as wood frequently remains undetected [16]. Sonography plays an important role in the evaluation of these patients [17].
Sonography has a reported sensitivity of 95% for detection of foreign bodies [18, 19].
In previous reports the positive predictive value of conventional radiography (CR) and sonography (US) were 100 and 95%, respectively, and for computed tomography (CT), and magnetic resonance imaging (MRI) were 95 and 93.8%, respectively. CT had a negative predictive value of 78.3%, while US, MRI, and CR had 73.7, 70.1, and 53.7%, respectively [20].
Non-opaque foreign bodies are visualized as hyper-echoic foci with accompanying acoustic shadows [17]. A hypoechoic halo surrounding the foreign body is sometimes seen, which represents edema, abscess, or granulation tissue [21].
The purpose of the study was to determine effectiveness of sonography for detection of radiolucent foreign bodies and to summarize the experiences using sonography in the management of patients with a suspected retained foreign body.

Materials and methods

From January 2014 to January 2016, 120 symptomatic patients with definite history and clinical suspicion of soft tissue foreign body and negative radiography were included in the study. A single radiologist who had 6 years of experience in the radiology department received the radiographs and carried out the sonographic examination. All ultrasound examinations were carried out on a sonosite Micromaxx USG machine using high-frequency (13–6 MHz) linear-array transducer. USG scans were performed in multiple planes as required according to the part being examined. After location of the soft tissue foreign body, its size, depth, and orientation were documented. Relationship to other structures such as muscles, tendon, bone, and vessels were determined. Doppler mode was also employed wherever deemed necessary. Any associated abscess, granuloma, or cellulitis were evaluated. A single orthopedic surgeon carried out direct surgical exploration guided by sonographic findings. Sensitivity of USG was determined with respect to the findings on surgical exploration (Fig. 1).

Results

One hundred and twenty patients underwent surgical exploration; among them 114 patients had a positive USG, and foreign body was retrieved from 108 patients, and in the rest of six patients in whom USG was positive, five had underwent at least one previous exploration. Among the six patients in whom USG was negative, one patient with strong suspicion of foreign body had chronic discharging sinus near tendo Achilles insertion, and a thorn was removed on exploration. Ninety patients (75%) were males and 30 (25%) were females. Mean age of the patients was 27.6 years (range 6–70 years). Duration of the patients’ complaint was from 1 day to 4 years, while in 50% of cases, it was less than a month. Predominant chief complaints of the patients were: foreign body sensation in 49 (40.83%), abscess formation in 38 (31.66%), discharging wound in 19 (15.83%), and pain in 14 (11.66%) cases. Foreign bodies removed were wooden (41 cases), thorn (38 cases), rubber/plastic from nail slipper (22 cases), and glass (8 cases). Majority of foreign bodies were removed from foot (69 cases) and hands (26 cases), and rest of foreign bodies were removed from ankle region (4 cases), wrist (3 cases), thigh (2 cases), leg (1 case), knee (2 cases), forearm (2 cases) (Tables 1, 2). Size of the foreign body varied between 3 to 32 mm with mean of 15 mm (Fig. 2).
Table 1
Site of foreign body removal in order of frequency
Site of foreign body removal
No. of cases
Foot
69
Hands
26
Ankle
4
Wrist
3
Thigh
2
Leg
1
Knee
2
Forearm
2
Total
109
Table 2
Types of foreign bodies recovered
Nature of foreign body
Number of cases
Wooden
41
Thorn
38
Rubber/plastic/nail slipper
22
Glass
08
Total
109
The accuracy, sensitivity, and PPV of this study were 94.16, 99.08, and 94.13%, respectively (Fig. 3).

Discussion

Conventional radiographs should be obtained to rule out the presence of radio-opaque foreign objects. Plain radiographs will depict approximately 80% of all foreign bodies, but several types of radiolucent foreign bodies such as wood remain undetected [22]. Plain radiographs of wooden FB are negative in 86% of such patients [23]. In these patients, sonography is the modality of choice for identification of such radiolucent foreign body.
The identification of wooden foreign bodies may be difficult on MRI, especially when foreign bodies are small, and there is no associated abscess, granulation tissue, or fluid collection. In such cases, the foreign body may appear as a signal void with surrounding nonspecific granulation tissue. Wooden foreign bodies may be seen signal void in all sequences, but after water absorption, it could be seen hypo-intense on T1 and hyper-intense on T2 images [17]. When compared with Sonography, MRI is more expensive, less readily available, and has less value in the detection of small wooden foreign bodies.
Sonographic evaluation provides important information on the depth, size, and anatomical relationship with surrounding structure [18, 21, 24]. Although CT has sensitivity 5–15 times greater than that of plain X-ray, it is not as sensitive as US, or MRI [25]. Additionally, the expense, use of radiation, and availability make the use of CT less than optimal in the clinical setting.
Out of 120 patients, USG was positive in 114 patients, and foreign body was retrieved from 108 patients, and in six patients for whom USG was falsely positive, five had underwent at least one previous surgical exploration, whereas among the six patients in whom USG was negative, foreign body was retrieved in one patient who had chronic discharge near ankle region. Detection of foreign body is difficult in interphalangeal space and in air-contaminated tissue after a penetrating trauma. FB must be distinguished from hyper-echoic body tissue such as ossified cartilage sesamoid bones, scar tissue, gas bubble, and intermuscular fascia. Acoustic shadowing is an important clue in the differential diagnosis [18, 21]. Acoustic shadowing can differentiate foreign body from scar tissue, gas bubble, and normal intermuscular fascia, because they are void of acoustic shadowing.
Our results demonstrate the effectiveness of sonography for detection of radiolucent FB. It is therefore an important and easily available modality that facilitates removal of the object by reducing the blind explorations and chances of iatrogenic tissue damage.
Peterson et al.  [17] showed that sonography is the modality of choice in patients who present with a history of antecedent skin puncture or when a penetrating injury is suspected.
Dumarey et al.  [26] showed that CT gave a good anatomic overview, but was not able to show the smaller fragments. Performing sonography is mandatory in patients with penetrating injuries by foreign bodies because it is very sensitive.
We believe that all foreign bodies were seen during sonographic examination as echogenic objects, and most of them (wooden, glass, etc.) may also show similar sonographic findings.
Foreign bodies in the extremities are a common complaint in agrarian populations. Most of these patients have normal X-rays as these foreign bodies being radiolucent. Ultrasonography being readily available and cheap modality could be a very useful tool to confirm the presence of foreign body, determine its depth, size and proximity to adjoining nerve, vessel, or a tendon. This will minimize the false-negative surgical explorations and prevent damage to adjoining structures. Although pre-op CT scan or MRI could be the better option but considering the availability and financial constrains especially in developing and underdeveloped nations, ultrasonography seems to be a useful tool to aid in exploration. Because of lack of comparison, we cannot recommend USG over CT scan or MRI, and this could be the possible limitation of our study.

Compliance with ethical standards

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

All the procedures performed in the study were in accordance with the ethical standards of the regional national research committee and with the 1964 declaration of Helsinki and its later amendments and comparable ethical standards.
The informed consent was taken from all the participants included in this study.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Literatur
1.
Zurück zum Zitat Boyse TD, Fessell DP, Jacobson JA, Lin J, van Holsbeeck MT, Hayes CW (2001) US of soft-tissue foreign bodies and associated complications with surgical correlation. Radiographics 21:1251–1256CrossRefPubMed Boyse TD, Fessell DP, Jacobson JA, Lin J, van Holsbeeck MT, Hayes CW (2001) US of soft-tissue foreign bodies and associated complications with surgical correlation. Radiographics 21:1251–1256CrossRefPubMed
3.
Zurück zum Zitat Borgohain B, Borgohain N, Nandique A, Gogoi PJ (2012) Case report and brief review of literature on sonographic detection of accidentally implanted wooden foreign body causing persistent sinus. Crit Ultrasound J 4:10CrossRefPubMedPubMedCentral Borgohain B, Borgohain N, Nandique A, Gogoi PJ (2012) Case report and brief review of literature on sonographic detection of accidentally implanted wooden foreign body causing persistent sinus. Crit Ultrasound J 4:10CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Yanay O, Vaughan DJ, Diab M, Brownstein D, Brogan TV (2001) Retained wooden foreign body in a child’s thigh complicated by severe necrotizing fasciitis: a case report and discussion of imaging modalities for early diagnosis. Pediatr Emerg Care 17:354–355CrossRefPubMed Yanay O, Vaughan DJ, Diab M, Brownstein D, Brogan TV (2001) Retained wooden foreign body in a child’s thigh complicated by severe necrotizing fasciitis: a case report and discussion of imaging modalities for early diagnosis. Pediatr Emerg Care 17:354–355CrossRefPubMed
5.
Zurück zum Zitat Fakoor M (2006) Prolonged retention of an intra-medullary wooden foreign body. Pak J Med Sci 22:78–79 Fakoor M (2006) Prolonged retention of an intra-medullary wooden foreign body. Pak J Med Sci 22:78–79
6.
Zurück zum Zitat Freund EI, Weigl K (1984) Foreign body granuloma: a cause of trigger thumb. J Hand Surg Br 9:210CrossRefPubMed Freund EI, Weigl K (1984) Foreign body granuloma: a cause of trigger thumb. J Hand Surg Br 9:210CrossRefPubMed
7.
Zurück zum Zitat Choudhari KA, Muthu T, Tan MH (2001) Progressive ulnar neuropathy caused by delayed migration of a foreign body. Br J Neurosurg 15:263–265CrossRefPubMed Choudhari KA, Muthu T, Tan MH (2001) Progressive ulnar neuropathy caused by delayed migration of a foreign body. Br J Neurosurg 15:263–265CrossRefPubMed
8.
Zurück zum Zitat Yang SS, Bear BJ, Wieland AJ (1995) Rupture of the flexor pollicis longus tendon after 30 years due to migration of a retained foreign body. J Hand Surg Br 20:803–805CrossRefPubMed Yang SS, Bear BJ, Wieland AJ (1995) Rupture of the flexor pollicis longus tendon after 30 years due to migration of a retained foreign body. J Hand Surg Br 20:803–805CrossRefPubMed
9.
Zurück zum Zitat Jablon M, Rabin SI (1988) Late flexor pollicis longus tendon rupture due to retained glass fragments. J Hand Surg Am 13:713–716CrossRefPubMed Jablon M, Rabin SI (1988) Late flexor pollicis longus tendon rupture due to retained glass fragments. J Hand Surg Am 13:713–716CrossRefPubMed
10.
Zurück zum Zitat Rainer C, Schoeller T, Wechselberger G, Bauer T, Hussl H (2000) Median nerve injury caused by missed foreign body. Scand J Plast Reconstr Surg Hand Surg 34:401–403CrossRefPubMed Rainer C, Schoeller T, Wechselberger G, Bauer T, Hussl H (2000) Median nerve injury caused by missed foreign body. Scand J Plast Reconstr Surg Hand Surg 34:401–403CrossRefPubMed
11.
Zurück zum Zitat Azzopardi EA, Xuereb CB, Iyer S (2009) Pyogenic granuloma as a surrogate indicator of deep seated foreign bodies: a case report. Cases J 2:7354PubMedPubMedCentral Azzopardi EA, Xuereb CB, Iyer S (2009) Pyogenic granuloma as a surrogate indicator of deep seated foreign bodies: a case report. Cases J 2:7354PubMedPubMedCentral
12.
Zurück zum Zitat James W, Robert A, Suzanne M (1995) Vascular complications of a foreign body in the hand of an asymptomatic patient. Ann Plast Surg 34:92–94CrossRef James W, Robert A, Suzanne M (1995) Vascular complications of a foreign body in the hand of an asymptomatic patient. Ann Plast Surg 34:92–94CrossRef
13.
Zurück zum Zitat Meurer WJ (2009) Radial artery pseudo aneurysm caused by occult retained glass from a hand laceration. Pediatr Emerg Care 25:255–257CrossRefPubMed Meurer WJ (2009) Radial artery pseudo aneurysm caused by occult retained glass from a hand laceration. Pediatr Emerg Care 25:255–257CrossRefPubMed
14.
Zurück zum Zitat Coombs CJ, Mutimer KL, Slattery PG, Wise AG (1990) Hide and seek: pre-operative ultrasound localization of non-radio-opaque foreign bodies. Aust N Z J Surg 60:989–991CrossRefPubMed Coombs CJ, Mutimer KL, Slattery PG, Wise AG (1990) Hide and seek: pre-operative ultrasound localization of non-radio-opaque foreign bodies. Aust N Z J Surg 60:989–991CrossRefPubMed
15.
Zurück zum Zitat Dunn JD (1987) Risk management in emergency medicine. Emerg Med Clin N Am 5:51–69 Dunn JD (1987) Risk management in emergency medicine. Emerg Med Clin N Am 5:51–69
16.
Zurück zum Zitat Graham DD Jr (2002) Ultrasound in the emergency department: detection of wooden foreign bodies in the soft tissues. J Emerg Med 22(1):75–79CrossRefPubMed Graham DD Jr (2002) Ultrasound in the emergency department: detection of wooden foreign bodies in the soft tissues. J Emerg Med 22(1):75–79CrossRefPubMed
17.
Zurück zum Zitat Peterson JJ, Bancroft LW, Kransdorf MJ (2002) Wooden foreign bodies: imaging appearance. AJR Am J Roentgenol 178(3):557–562CrossRefPubMed Peterson JJ, Bancroft LW, Kransdorf MJ (2002) Wooden foreign bodies: imaging appearance. AJR Am J Roentgenol 178(3):557–562CrossRefPubMed
18.
Zurück zum Zitat Crowford R, Matheson AB (1989) Clinical value of ultrasonography in detection and removal of radiolucent foreign bodies. Injury 20:341–343CrossRef Crowford R, Matheson AB (1989) Clinical value of ultrasonography in detection and removal of radiolucent foreign bodies. Injury 20:341–343CrossRef
19.
Zurück zum Zitat Ober CP, Jones JC, Larson MM, Lanz OI, Werre SR (2008) Comparison of ultrasound, computed tomography, and magnetic resonance imaging in detection of acute wooden foreign bodies in the canine manus. Vet Radiol Ultrasound 49(5):411–418CrossRefPubMed Ober CP, Jones JC, Larson MM, Lanz OI, Werre SR (2008) Comparison of ultrasound, computed tomography, and magnetic resonance imaging in detection of acute wooden foreign bodies in the canine manus. Vet Radiol Ultrasound 49(5):411–418CrossRefPubMed
20.
Zurück zum Zitat Venter NG, Jamel N, Marques RG, Djahjah F, MendonçaLde S (2005) Evaluation of radiological methods for detection of wood foreign body in animal model. Acta Cir Bras 20(Suppl 1):34–41CrossRefPubMed Venter NG, Jamel N, Marques RG, Djahjah F, MendonçaLde S (2005) Evaluation of radiological methods for detection of wood foreign body in animal model. Acta Cir Bras 20(Suppl 1):34–41CrossRefPubMed
21.
Zurück zum Zitat Little CM, Parker MG, Callowich MC, Sartori JC (1986) The ultrasonic detection soft tissue foreign bodies. Investig Radiol 21:275–277CrossRef Little CM, Parker MG, Callowich MC, Sartori JC (1986) The ultrasonic detection soft tissue foreign bodies. Investig Radiol 21:275–277CrossRef
22.
Zurück zum Zitat Donaldson J (1991) Radiographic imaging of foreign bodies in the hand. Hand Clin 7:125–134PubMed Donaldson J (1991) Radiographic imaging of foreign bodies in the hand. Hand Clin 7:125–134PubMed
23.
Zurück zum Zitat Anderson MA, Newmeyer WL, Kilgore ES (1982) Diagnosis and treatment of retained foreign bodies in the hand. Am J Surg 144:63–67CrossRefPubMed Anderson MA, Newmeyer WL, Kilgore ES (1982) Diagnosis and treatment of retained foreign bodies in the hand. Am J Surg 144:63–67CrossRefPubMed
24.
Zurück zum Zitat Conti RJ, Shinder M (1991) Soft tissue calcification induced by local corticosteroid injection. J Foot Surg 30:34–37PubMed Conti RJ, Shinder M (1991) Soft tissue calcification induced by local corticosteroid injection. J Foot Surg 30:34–37PubMed
25.
Zurück zum Zitat Flom LL, Ellis GL (1992) Radiologic evaluation of foreign bodies. Emerg Med Clin North Am 10:163–176PubMed Flom LL, Ellis GL (1992) Radiologic evaluation of foreign bodies. Emerg Med Clin North Am 10:163–176PubMed
26.
Zurück zum Zitat Dumarey A, De Maeseneer M, Ernst C (2004) Large wooden foreign body in the hand: recognition of occult fragments with ultrasound. Emerg Radiol 10(6):337–339CrossRefPubMed Dumarey A, De Maeseneer M, Ernst C (2004) Large wooden foreign body in the hand: recognition of occult fragments with ultrasound. Emerg Radiol 10(6):337–339CrossRefPubMed
Metadaten
Titel
Role of ultrasound in detection of radiolucent foreign bodies in extremities
verfasst von
Mehraj D. Tantray
Asim Rather
Qazi Manaan
Irfan Andleeb
Mir. Mohammad
Yasmeena Gull
Publikationsdatum
09.02.2018
Verlag
Springer Milan
Erschienen in
Strategies in Trauma and Limb Reconstruction / Ausgabe 2/2018
Print ISSN: 1828-8936
Elektronische ISSN: 1828-8928
DOI
https://doi.org/10.1007/s11751-018-0308-z

Weitere Artikel der Ausgabe 2/2018

Strategies in Trauma and Limb Reconstruction 2/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.