Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 6/2021

Open Access 15.04.2020 | Original Article

Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study

verfasst von: Pol Maria Rommens, Eva Mareike Nolte, Johannes Hopf, Daniel Wagner, Alexander Hofmann, Martin Hessmann

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 6/2021

Abstract

Introduction

Iliosacral screw osteosynthesis is a well-accepted procedure for stabilization of sacral fractures and iliosacral (fracture) dislocations.

Materials and Methods

In this monocentric study, safety and efficacy of conventional 2D-fluoroscopic-guided iliosacral screw insertion were evaluated.

Results

During a 10-year period (2005–2014), 98 patients between the age of 18 and 65 years received 207 iliosacral screws in 101 procedures. Average patient age was 43.2 years. There were 46 Type B and 40 Type C injuries in the AO/OTA classification, nine patients had a fragility fracture of the pelvis. In three patients, primary radiological data were missing. The indication for surgical treatment was a sacral fracture in 97 patients, a pure iliosacral dislocation in 37 patients and a fracture-dislocation in 31 patients. 70 procedures were performed with the patient in supine position, 31 with the patient in prone position. Surgery was done in a minimal-invasive technique in 76 patients, in 22 patients an open reduction was necessary before screw insertion. 81 patients received a unilateral, 17 patients a bilateral screw osteosynthesis. 199 screws were inserted in S1, only eight screws in S2. 65 patients received two screws unilaterally, ten patients two screws bilaterally. There were no vascular or neurologic complications. During in-hospital stay, there were seven complications, which needed 12 operative revisions: three wound infections, two hematomas, one screw malalignment and one early screw loosening. In 28 patients with 56 iliosacral screws, a pelvic CT-scan was performed during follow-up. A penetration of a cortical layer was diagnosed in 20 of these screws. All penetrations were seen in double screw osteosynthesis of S1. In none of the patients, complaints could be explained by the malalignment of these screws. Five operative revisions were performed during follow-up: two for screw loosening, two for fracture healing problems and one for screw malalignment. Metal removal was performed in 39 patients with 75 screws. 2D-fluoroscopic-guided iliosacral screw osteosynthesis is a safe and efficient procedure in clinical practice.

Discussion

A thorough preoperative evaluation of the morphology of the upper sacrum and careful operative procedure are indispensable. Fluoroscopic views in AP, lateral, inlet and outlet must allow recognition of all anatomical landmarks. The indication for double screw osteosynthesis in S1 should be taken with caution. Screw malalignments do not inevitably correlate with complaints.
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations

Introduction

Pelvic ring disruptions occur after high-energy trauma. They have different morphologies, depending on the direction of the traumatic force. Rotationally unstable lesions, described as open book and lateral compression injuries, consist of a complete disruption of the anterior and an incomplete disruption of the posterior pelvic ring. Vertically unstable lesions, described as vertical shear injuries, show a complete disruption of the anterior and posterior pelvic ring [13]. Soft tissue and hollow organ injuries often accompany fractures and dislocations. Many patients with pelvic ring injuries are severely injured. Emergency management focuses on resuscitation and control of blood loss [4, 5]. The goal of definitive treatment is the restoration of stability and symmetry of the pelvic ring. Bone reconstruction goes parallel with wound management and the restoration of organ function. Operative treatment results in reduced mortality and improved functional outcome [6]. Correct anatomy and adequate stability of the broken posterior pelvis are obtained by open or closed reduction and internal fixation [7, 8]. Several methods of fixation exist and follow different principles of osteosynthesis: bridging the area of instability with plates and screws or bars versus compression of the fracture zone with interfragmentary lag screws. Iliosacral screw osteosynthesis is a reliable method of stabilization of sacral fractures, iliosacral dislocations and fracture-dislocations after high-energy pelvic trauma [9]. It is also successfully used in fragility fractures of the posterior pelvic ring [1012]. Although widely accepted, the technique is associated with concerns of screw malalignment with damage to vessels or nerves; and with implant loosening. 2D- and 3D-based computer navigations are helpful tools for correct screw placement decreasing the risk of iatrogenic damages [13, 14]. In this monocentric retrospective study, we analyse the safety and efficacy of fluoroscopy-based iliosacral screw osteosynthesis in a large series of patients below the age of 65. The technique is described in detail and the results are compared with those of similar series, in which screw insertion was done similarly or supported by navigation.

Surgical technique

Before surgery, anatomy of the upper sacrum is analyzed with pelvic overviews in AP, inlet and outlet and pelvic CT-data with transverse, coronal and sagittal reconstructions [1517]. The position of the sacrum is evaluated and the angles of the fluoroscope for exact inlet and outlet views are analyzed. High-quality fluoroscopy images of the posterior pelvis must be available during the surgical intervention. A rectal washout is helpful to prepare the patient on the day before surgery, if applicable. The use of a carbon operation table is recommended. After patient positioning on the operation table and before beginning the procedure, fluoroscopic images in AP, inlet and outlet views are obtained. The following anatomic landmarks of the upper sacrum and the iliosacral joints are identified on the three pelvic overviews: S1 superior endplate, roof of the sacral ala bilaterally, sacroiliac joints bilaterally, neuroforamen S1 and S2 with their curved roofs bilaterally, anterior sacral cortex, sacral canal, canal of S1 and S2 roots. A strict lateral view of the lumbosacral junction is also obtained. The trapeziform area in the S1 body, which corresponds with the safe corridor for screw insertion, is identified. The margins of the trapeziform area are: the sacral alar slope superiorly, the sacral cortex anteriorly, the sacral canal posteriorly, the transition of S1 to S2 and the canal of the S1 root inferiorly (Fig. 1).
The procedure can be performed with the patient in prone or in supine position [18]. The prone position allows for direct access to the sacrum, sacroiliac joint and posterior ilium and enables open reduction, when needed. Due to gravity, the gluteal soft tissues will less interfere with access to the posterior pelvic structures. This is of major advantage in obese persons. In the lateral view, the center of the trapeziform area is identified. Under fluoroscopic control, a vertically directed 2.8 mm diameter drill bit is placed along the skin of the buttock of the injured side, until its tip projects on the center of the trapeziform area (Fig. 1). The drill bit is hold in this position. A small horizontal skin incision is made at the tip of the drill bit. The drill is now placed horizontally and pushed through the gluteal muscles. Under fluoroscopic control, its tip is placed at the ideal insertion point at the outer cortex of the posterior ilium. With a slight hammer blow or a short drilling, the outer cortex is perforated. The correct position of the drill is now controlled under fluoroscopy in AP, inlet and outlet views. The direction of the drill bit is fine-tuned so that it passes the center of the S1 body during the drilling procedure. During the drilling procedure, the tip of the drill bit consecutively perforates the medial cortex of the posterior ilium and the lateral cortex of the sacrum. In regular intervals, the position of the drill bit is controlled in relation to the visible landmarks of S1. Drilling is discontinued when the tip of the drill reaches the opposite sacral ala. In case the opposite sacral ala cannot be reached due to sacral dysmorphism, an as long trajectory as possible is drilled. With a depth gauge, the length of the drill inside the bone is measured. Three cortices (outer and inner cortex of the ilium and lateral cortex of the sacrum) are over-drilled with a cannulated 4.5 mm drill bit, which is glided over the 2.8 mm drill bit. Thread-cutting of the screw trajectory is performed in younger patients. In old patients with osteoporotic bone, no tapping is done to improve the holding power of the screw in the bone. A 7.3 mm or 8 mm cannulated screw of appropriate length is inserted. During insertion, the surgeon can control the distance between washer with screw head and the lateral cortex with an orthograd fluoroscopic view of the posterior ilium; and avoid penetration. The surgeon also feels increasing resistance when the screw head with washer presses directly on the lateral cortex. No compression is obtained when a screw with continuous thread is used; the screw has the function of a positioning screw. Depending on the diameter of the sacral corridor, insertion of one or two screws is possible. In case two screws are inserted in S1, their trajectories are slightly converging in the inlet view to minimize the risk of screw malalignment (Fig. 2a–g). If the second screw is placed in the body of S2, the same steps of the procedure are repeated, taking into account that the dimensions of the sacral corridor of S2 are smaller than those of S1.
In the supine position, the gluteal soft tissues are pushed off towards lateral, which makes access to the posterior ilium more difficult [16]. The patient is placed with the injured side on the margin of a radiolucent table enabling free orientation of the drill bit. The technique of screw insertion is the same as described for the prone position.

Patients and methods

We reviewed all medical charts of adult patients between 18 and 65 years of age with a posterior pelvic ring injury, who were admitted to the Department of Orthopaedics and Traumatology of the University Medical Center of Mainz, Germany between January 1st 2005 and December 31st 2014 (10-year period). Only patients, who received a fluoroscopy-based iliosacral screw osteosynthesis as part of the stabilization of the pelvic ring were included in the study. Delayed timing of the surgical procedure was not an exclusion criterion. After the procedure, fracture reduction and position of the screws was controlled with conventional a.-p., inlet and outlet views. Only in case of uncertainty or postoperative complaints, a pelvic CT was performed. Epidemiologic data and the following information related to the surgical procedure were collected: trauma mechanism, classification of pelvic ring injury, delay between trauma and intervention, open or closed reduction, level and side of screw insertion, number of screws, quality of screw position, additional stabilization procedures at the pelvic ring, intraoperative and postoperative complications related to the iliosacral screw osteosynthesis, surgical revisions, fracture healing, metal removal. Screw position was rated as published by Gras et al. [19]. An excellent screw position is defined as a screw with complete intraosseous position. An acceptable screw position is defined as a screw which has contact with cortical bone (anterior sacral cortex, neuroforamen, sacral canal). A screw is graded as malaligned when it penetrates cortical bone.

Results

Ninety-eight patients, younger than 65 years of age, received fluoroscopy-based iliosacral screw osteosynthesis in the mentioned period. There were 56 male (57.1%) and 42 female (42.9%) patients. The average patient age was 43.2 years (median age: 46.0 years). The average age of men was 42.0 and of women 45.4 years. There were 46 traffic accidents, 32 falls and 17 sports or other accidents. In three patients trauma mechanism was not memorable. 59 patients (60.2%) had one or more additional fractures, 21 were polytraumatized (21.4%) and 18 had an isolated pelvic ring injury (18.4%) (Table 1).
Table 1
Demographics
Number of patients
98 (100%)
Men
56 (57.1%)
Women
42 (42.9%)
Average (mean) age
43.2 (46.0) years
Average age men
42.0 years
Average age women
45.4 years
Patients with additional fractures
59 (60.2%)
Polytraumatized patients
21 (21.4%)
Patients with monotrauma
18 (18.4%)
There were 46 Type B and 40 Type C injuries in the AO/OTA classification [1, 2]. There were 17 anteroposterior compression (APC), 38 lateral compression (LC) and 31 vertical shear (VS) injuries in the Young-Burgess classification [3]. 9 injuries were classified with the Rommens and Hofmann classification for fragility fractures of the pelvis (FFP) [12]. There were 3 FFP Type II, 3 FFP Type III and 3 FFP Type IV lesions. In three patients, classification was not possible (preoperative conventional X-rays or CT-data not available (Table 2).
Table 2
Classification
AO/OTA classification Type B
46
AO/OTA classification Type C
40
Young-Burgess classification LC
38
Young-Burgess classification VS
31
Young-Burgess classification APC
17
Rommens–Hofmann classification FFP Type II
3
Rommens–Hofmann classification FFP Type III
3
Rommens–Hofmann classification FFP Type IV
3
Classification not possible
3
The indications for iliosacral screw osteosynthesis were 97 sacral fractures (63 unilateral and 17 bilateral), 37 isolated iliosacral dislocations (29 unilateral and 4 bilateral) and 31 fracture-dislocations of the iliosacral joint (29 unilateral and 1 bilateral).
In all patients, a concomitant lesion of the anterior pelvic ring was seen. 71 patients suffered pubic rami fractures (47 unilateral and 24 bilateral), while 27 patients suffered a diastasis of the pubic symphysis. In 26 patients, there was a concomitant fracture of the acetabulum, two of them had bilateral fractures (Table 3).
Table 3
Fracture description
Sacral fracture unilateral
63
Pure sacroiliac dislocation unilateral
29
Sacroiliac fracture dislocation unilateral
29
Sacral fracture bilateral
17
Pure sacroiliac dislocation bilateral
4
Sacroiliac fracture dislocation bilateral
1
Additional fracture of anterior pelvis
98 (100%)
Unilateral pubic rami
47
Symphysis pubis diastasis
27
Bilateral pubic rami
24
Fracture of the acetabulum unilateral
24
Fracture of the acetabulum unilateral
2
The operative procedure was performed after an average of 4.8 days (median 5.5 days). In 63 patients (64.3%), the screw osteosynthesis was performed as primary procedure, in 21 after a damage control procedure (21.4%) and in 14 after an attempt of conservative treatment (14.3%).
There were 101 operations in these 98 patients. An additional iliosacral screw osteosynthesis was performed in a separate operation in three patients. 70 procedures were performed in supine (69.3%), 31 procedures in prone position (30.7%). In 76 patients, the screw osteosynthesis was performed as a minimal-invasive procedure after closed reduction (77.6%), in 22 patients an open reduction was performed before screw insertion (22.4%).
In total, 207 screws were inserted. In 81 patients, the screw osteosynthesis was done unilaterally (82.7%), in 17 patients bilaterally (17.3%). 199 screws were inserted in S1 (96.1%), only eight screws in S2 (3.9%). 65 patients received two screws unilaterally (66.3%), 16 patients one screw unilaterally (16.3%), ten patients two screws bilaterally (10.2%), six patients one screw bilaterally (6.1%) and one patient received three screws (1.1%) (Table 4).
Table 4
Operation technique
Patient in supine position
70 (69.3%)
Patient in prone position
31 (30.7%)
Patients with closed procedure
76 (77.6%)
Patients with open procedure
22 (22.4%)
Number of screw osteosynthesis
207
Patients with 2 screws unilaterally
65 (66.3%)
Patients with 1 screw unilaterally
16 (16.3%)
Patients with 2 screws bilaterally
10 (10.2%)
Patients with 1 screw bilaterally
6 ( 6.1%)
Patients with 3 screws
1 ( 1.1%)
Screws in S1
199 (96.1%)
Screws in S2
8 ( 3.9%)
One or several of the following techniques were used for additional stabilization of the posterior and anterior pelvic ring in 77 patients (78.6%): plate osteosynthesis in 38, retrograde transpubic screw in 29, external fixation in 18, transsacral bar in 6 and lumbopelvic fixation in 2.
There were no iatrogenic vascular or neurologic injuries due to the screw osteosynthesis. Three patients died postoperatively due to traumatic reasons. without a relation to the iliosacral screw osteosynthesis. During in-hospital stay, seven complications (7.1%) were seen, which were related to the screw insertion: three wound infections, two hematomas, one screw malalignment and one early screw loosening. There were 12 operative revisions in five patients, ten of them for infection control in three patients. The other revisions were due to screw malalignment (n = 1) and early screw loosening (n = 1) (Table 5).
Table 5
Complications related to iliosacral screw osteosynthesis. Number and reason of surgical re-interventions
In-hopital death
3 (not related to iliosacral screw osteosynthesis)
Patients with wound infection
3 (3.1%)
Patients with wound haematoma
2 (2.0%)
Number of early surgical revisions
12
 Wound debridement
10
 Malposition
1
 Loosening
1
Number of later surgical revisions
5
 Screw loosening
2
 Bone healing problem
2
 Malposition
1
Metal removal-number of patients
39 (39.8%)
Metal removal-number of screws
75 (36.2%)
Patients could be discharged after an average of 22 days (median 16 days). Follow-up time was 756 days in average (median 502 days). Seventeen patients (17.3%) had an uneventful postoperative course during their in-hospital stay, but did not show up for follow-up. All other patients received conventional pelvic overviews after 3, 6 and 12 weeks. Postoperatively, a pelvic CT-scan was not carried out unless patients had complaints, which could be related to the iliosacral screw osteosynthesis. In 28 patients (28.6%), with 56 iliosacral screws (27.0%), a pelvic CT-scan was performed postoperatively or during follow-up. On these CT-images, a penetration of cortical layer was diagnosed in 20 screws. In none of these screws, cortical penetration was visible on conventional X-rays. All penetrations were seen in double screw osteosynthesis of S1. In none of the patients, the complaints of the patients could be explained by the malaligned screws. Five late operative revisions (5 of 101 procedures = 5%) were performed during follow-up: two because of screw loosening (2% of procedures and 1% of screws), two because of bone healing problems (2%) and one because of malreduction (1%). Metal removal was performed in 39 patients (39.8%) with 75 screws (36.2%) (Table 5).

Discussion

Iliosacral screw osteosynthesis is a widely used and accepted stabilisation technique for instabilities of the posterior pelvic ring. The technique was first described in the 1980s [7, 8]. Biomechanical studies have shown that the obtained stability is equivalent or superior to other stabilisation methods [20]. Van Zwienen et al. proved that a second iliosacral screw in S1 improves rotational stiffness and load to failure [21]. Kraemer et al. calculated that iliosacral screws reaching to the sacral body with a long thread are more stable than short screws, which only reach into the sacral ala [22]. The challenging part of the procedure is the correct placement of the screw(s) within the trabecular bone of S1 and/or S2. The narrowest part of the corridor is the area above the neuroforamen S1 or between the neuroforamina S1 and S2. Carlson et al. introduced the vestibule concept. The safe corridor for screw placement in S1 and S2 has the shape of a diabolo with the vestibule as its narrowest part (Fig. 3) [23]. Depending of the morphology of the upper sacrum and the location of the fracture, the screws are inserted in the coronal plane or oblique. Optimally, the screws are placed perpendicular to the plane of instability: in the coronal plane in vertical sacral fractures and oblique in iliosacral dislocations, fracture-dislocations or sacral dysmorphism (Fig. 4a–h). Oblique screws are directed from inferior-posterior to superior-anterior. In sacral dysmorphism, the S1-corridor is smaller than the S2-corridor [24]. Preoperative analysis and planning are indispensable for safe screw placement. On conventional X-rays and axial, coronal and oblique CT-pictures, the individual anatomy of the upper sacrum and ideal pathway of the screws must be determined, for which planning tools and recommendations exist [15, 2527].
In this monocentric retrospective study, we reviewed the safety and efficacy of iliosacral screw osteosynthesis in 98 patients. 101 procedures and 207 screw insertions were analysed. We excluded procedures performed in patients above 65 years of age because of the different bone density in the sacrum of older persons. Bone density influences the holding power of the screws and lower bone density enhances the risk of screw loosening [28].
A minority of patients suffered an isolated injury of the pelvic ring (18.4%), more than 80% of the patients had concomitant lesions or were polytraumatized. Only nine patients (9.2%) suffered a low-energy trauma. All patients had a combination of an anterior and posterior pelvic instability. The distribution of high-energy injuries was nearly equal between Type B and Type C of the AO/OTA classification. There were more LC and VS than APC injuries in the Young-Burgess classification. Iliosacral screw osteosynthesis was additionally performed in many rotationally unstable but vertically stable pelvic ring injuries, which had been stabilized with an anterior fixation. In their biomechanical study, Simonian et al. proved that combined fixation of the anterior and posterior pelvic ring obtains the highest stability in APC injuries [29]. Dujardin et al. reported less micromotion at the sacroiliac joint in APC injuries, when anterior plate fixation was combined with iliosacral screw fixation [30]. In our series, operative stabilization of the anterior pelvic ring was performed in more than 75% of patients.
Iliosacral screw insertion was not done on the day of trauma, but after an average of 4.8 days. Iliosacral screw insertion in an emergency situation has a higher risk of screw malalignment with iatrogenic vascular or neurologic damage. In nearly two thirds of the patients, the procedure was performed as first and definitive intervention, only in one fifth after a damage control procedure. Non-emergent intervention after a few days gives the surgical team the opportunity of optimal analysis of radiologic images and best preparation of the patient. A minority of interventions was done with the patient in prone position (n = 31, 30.7%). In 22 of them (71.0%), open reduction was performed before internal fixation. The prone position is more cumbersome for the anaesthetist and takes 20 additional minutes for turning and correct positioning of the patient [31].
Iliosacral screw placement is regarded as a challenging procedure with the risk of damaging neurological and/or vascular structures. Several technologies have been developed to enhance the accuracy of iliosacral screw placement: planning tools [15, 26, 32, 33], 3D-fluoroscopic navigation [34], CT-based navigation [35, 36] and robot-assisted navigation [37]. Several authors comparing 2D-fluoroscopy with computer navigation prefer the navigation techniques, although screw perforations have been documented between 0 and 22.6% with the navigation technique [36, 38]. In a recent study conducted by Berger-Groch et al. 100 2D-navigated procedures were compared with 36 conventional fluororoscopy-based procedures. There were similar rates of malpositioning, but the radiation exposure was reduced by half when using computer navigation [39]. Other authors mention higher radiation doses for the patient when using computer navigation [40, 41]. Most important is the rate of intra- and postoperative complications due to the procedure. In a large prospective study conducted in 23 German Level I trauma centers, the number of complications did not differ between the conventional 2D-fluoroscopy and the 3D-navigation technique [42]. In our series, early revision surgery due to surgery-related complications was needed in five patients (5.1%). None of the revisions was performed due to neurologic or vascular problems. In 70 patients without any complaints, we did not see the necessity of performing a postoperative pelvic CT-scan. In 28 patients with 56 iliosacral screws, we performed a pelvic CT-scan because of complaints in the pelvic region during follow-up. A cortical perforation was seen in 20 screws, but none of them explained the symptoms of the patients (Fig. 5a–j). In high-energy trauma, persisting pain is frequently seen and may be related to traumatic neurological or soft tissue damage, scar tissue formation or instability [43]. All cases of cortex perforation were seen in patients, who received two unilateral screws in S1. This finding is supported by other literature data. As a result of their anatomical study, Ebraheim et al. concluded that unilateral double screw insertion in S1 has a higher risk of malalignment of the second screw [44]. In their retrospective study on 82 patients with 147 iliosacral screw insertions, Grossterlinden et al. also found that the insertion of two unilateral screws into S1 was associated with a higher screw misplacement rate [45]. In a series of 77 patients, Khaled et al. did not find a different outcome with the addition of a second screw [46]. On the other hand, an additional screw in S1 significantly enhances stability and one iliosacral screw in S1 may not be sufficient in very unstable fracture patterns [21]. In their retrospective study on 62 vertically unstable pelvic fractures, Griffin et al. found four failures of fixation, all of them in vertical sacral fractures [47]. The indication for a second unilateral S1 screw should, therefore, be taken after a thorough analysis of the morphology of the upper sacrum and the fracture pattern of the posterior pelvic ring. In B-type lesions, in which the tension band function of the posterior ligaments is preserved, we believe that the insertion of one S1 screw is sufficient. In C-type lesions, which are vertically unstable, the insertion of two unilateral screws in S1 is preferable, provided that a large corridor is available. In case of a small corridor or dysmorphic sacrum, the insertion of only one S1 screw is safer. An additional screw in S2 or an additional tension band plate or internal fixator is then recommended to obtain the required stability [45]. In adult patients, screws which reach into the sacral body with its high bone mineral density provide sufficient stiffness [22].
Metal removal was done in 39.8% of patients and 36.2% of screws. This high number cannot be explained by complaints due to the implants, but rather by the wish of the patients. In other series, metal removal was only performed in case of implant-related complaints and gave good outcome [48].
We conclude that 2D-fluoroscopy based iliosacral screw osteosynthesis is a safe and reliable procedure for internal fixation of posterior pelvic ring lesions. In an environment, where computer-assisted navigation is not available, 2D-fluoroscopy remains a good alternative. The operation must be prepared through meticulous analysis of the morphology of the upper sacrum on conventional X-rays and CT-data. Although there may exist a higher risk of cortical penetration, this did not correlate with complaints of the patient in our series.
This study has several limitations. After surgery, a CT-scan of the pelvis was merely performed in patients with complaints. This was in a minority of patients (28.6%) and screws (27.0%). Because all patients had a preoperative CT-scan of the pelvis, intraoperative fluoroscopy as well as pre- and postoperative conventional X-rays, we refrained from taking a postoperative CT-scan in every patient to avoid additional radiation exposure. We assumed that the position of the screws was correct in all patients, who did not express any complaints. The malalignment rate following the definition of Gras et al. [19] was calculated with 9.7%. Although without any clinical significance, there may have been additional screws with cortical perforation in the patients, who did not have a postoperative pelvic CT-scan. We did not measure fluoroscopy time of iliosacral screw insertion. In 77 patients (78.6%), an additional anterior stabilization was performed in the same operative procedure, during which fluoroscopy was also done. The exact time of fluoroscopy of the iliosacral screw insertion only could not be distracted from the overall fluoroscopy time in this retrospective study. We did not perform a comparative study with 2D- or 3D-assisted computer navigation as we did not have the soft- and hardware for intraoperative 3D-imaging available in our institution. We did not perform an outcome study of the involved patients, as we focused on the feasibility and safety of the surgical technique. Outcome is depending on multiple factors, of which iliosacral screw osteosynthesis in only one [49]. Despite of these limitations, we still believe that these data are an important addition to the already available literature on this subject.

Conclusion

2-D fluoroscopic guided iliosacral screw osteosynthesis is a safe and efficient procedure for fixation of posterior pelvic fractures and dislocations. Indispensable condition is the thorough preoperative analysis of the morphology of the upper sacrum, the identification of safe corridors and the recognition of anatomical landmarks in the different fluoroscopic views. Screws with cortical perforation may be clinically silent and not responsible for postoperative complaints of the patient.

Acknowledgements

Open Access funding provided by Projekt DEAL.

Compliance with ethical standards

Ethical approval

This study was approved by the Ethics Commission of the State Chamber of Medicine in Rhineland-Palatinate (Reference: 837.140.17 (10974).
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Neuer Inhalt

Print-Titel

Literatur
1.
Zurück zum Zitat Tile M. Acute pelvic fractures: I. Causation and classification. J Am Acad Orthop Surg. 1996;4(3):143–51.PubMed Tile M. Acute pelvic fractures: I. Causation and classification. J Am Acad Orthop Surg. 1996;4(3):143–51.PubMed
2.
Zurück zum Zitat Spiegel PG. Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification. J Orthop Trauma. 1996;10:1–154. Spiegel PG. Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification. J Orthop Trauma. 1996;10:1–154.
3.
Zurück zum Zitat Dalal SA, Burgess AR, Siegel JH, Young JW, Brumback RJ, Poka A, et al. Pelvic fracture in multiple trauma: classification by mechanism is key to pattern of organ injury, resuscitative requirements, and outcome. J Trauma. 1989;29(7):981–1000.PubMed Dalal SA, Burgess AR, Siegel JH, Young JW, Brumback RJ, Poka A, et al. Pelvic fracture in multiple trauma: classification by mechanism is key to pattern of organ injury, resuscitative requirements, and outcome. J Trauma. 1989;29(7):981–1000.PubMed
4.
Zurück zum Zitat Rommens PM, Hofmann A, Hessmann MH. Management of acute hemorrhage in pelvic trauma: an overview. Eur J Trauma Emerg Surg. 2010;36(2):91–9.PubMed Rommens PM, Hofmann A, Hessmann MH. Management of acute hemorrhage in pelvic trauma: an overview. Eur J Trauma Emerg Surg. 2010;36(2):91–9.PubMed
5.
Zurück zum Zitat Marzi I, Lustenberger T. Management of bleeding pelvic fractures. Scand J Surg. 2014;103(2):104–11.PubMed Marzi I, Lustenberger T. Management of bleeding pelvic fractures. Scand J Surg. 2014;103(2):104–11.PubMed
6.
Zurück zum Zitat Pohlemann T, Stengel D, Tosounidis G, Reilmann H, Stuby F, et al. Survival trends and predictors of mortality in severe pelvic trauma: estimates from the German Pelvic Trauma Registry Initiative. Injury. 2011;42(10):997–1002.PubMed Pohlemann T, Stengel D, Tosounidis G, Reilmann H, Stuby F, et al. Survival trends and predictors of mortality in severe pelvic trauma: estimates from the German Pelvic Trauma Registry Initiative. Injury. 2011;42(10):997–1002.PubMed
7.
Zurück zum Zitat Ward EF, Tomasin J, Vander Griend RA. Open reduction and internal fixation of vertical shear pelvic fractures. J Trauma. 1987;27(3):291–5.PubMed Ward EF, Tomasin J, Vander Griend RA. Open reduction and internal fixation of vertical shear pelvic fractures. J Trauma. 1987;27(3):291–5.PubMed
8.
Zurück zum Zitat Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res. 1989;242:83–97. Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res. 1989;242:83–97.
9.
Zurück zum Zitat Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, et al. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma. 1999;13(2):107–13.PubMed Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, et al. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma. 1999;13(2):107–13.PubMed
10.
Zurück zum Zitat Hopf JC, Krieglstein CF, Müller LP, Koslowsky TC. Percutaneous iliosacral screw fixation after osteoporotic posterior ring fractures of the pelvis reduces pain significantly in elderly patients. Injury. 2015;46(8):1631–6.PubMed Hopf JC, Krieglstein CF, Müller LP, Koslowsky TC. Percutaneous iliosacral screw fixation after osteoporotic posterior ring fractures of the pelvis reduces pain significantly in elderly patients. Injury. 2015;46(8):1631–6.PubMed
11.
Zurück zum Zitat Rommens PM, Arand C, Hofmann A, Wagner D. When and how to operate fragility fractures of the pelvis? Ind J Orthop. 2019;53(1):128–37. Rommens PM, Arand C, Hofmann A, Wagner D. When and how to operate fragility fractures of the pelvis? Ind J Orthop. 2019;53(1):128–37.
12.
Zurück zum Zitat Rommens PM, Hofmann A. Comprehensive classification of fragility fractures of the pelvic ring: recommendations for surgical treatment. Injury. 2013;44(12):1733–44.PubMed Rommens PM, Hofmann A. Comprehensive classification of fragility fractures of the pelvic ring: recommendations for surgical treatment. Injury. 2013;44(12):1733–44.PubMed
13.
Zurück zum Zitat Zwingmann J, Konrad G, Mehlhorn AT, Südkamp NP, Oberst M. Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. conventional). J Trauma. 2010;69(6):1501–6.PubMed Zwingmann J, Konrad G, Mehlhorn AT, Südkamp NP, Oberst M. Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. conventional). J Trauma. 2010;69(6):1501–6.PubMed
14.
Zurück zum Zitat Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133(9):1257–65.PubMed Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133(9):1257–65.PubMed
15.
Zurück zum Zitat Krappinger D, Lindtner RA, Benedikt S. Preoperative planning and safe intraoperative placement of iliosacral screws under fluoroscopic control. Oper Orthop Traumatol. 2019;31(6):465–73.PubMedPubMedCentral Krappinger D, Lindtner RA, Benedikt S. Preoperative planning and safe intraoperative placement of iliosacral screws under fluoroscopic control. Oper Orthop Traumatol. 2019;31(6):465–73.PubMedPubMedCentral
16.
Zurück zum Zitat Rommens PM, Wagner D, Hofmann A. Iliosacral screw osteosynthesis. In: Rommens PM, Hofmann A, editors. Fragility fractures of the pelvis. Berlin: Springer International Publishing; 2018. p. 121–138. Rommens PM, Wagner D, Hofmann A. Iliosacral screw osteosynthesis. In: Rommens PM, Hofmann A, editors. Fragility fractures of the pelvis. Berlin: Springer International Publishing; 2018. p. 121–138.
17.
Zurück zum Zitat Osterhoff G, Ossendorf C, Wanner GA, Simmen HP, Werner CM. Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications. Arch Orthop Trauma Surg. 2011;131(6):809–13.PubMed Osterhoff G, Ossendorf C, Wanner GA, Simmen HP, Werner CM. Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications. Arch Orthop Trauma Surg. 2011;131(6):809–13.PubMed
18.
Zurück zum Zitat Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995;9(3):207–14.PubMed Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995;9(3):207–14.PubMed
19.
Zurück zum Zitat Gras F, Marintschev I, Wilharm A, Klos K, Mückley T, Hofmann GO. 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series. BMC Musculoskelet Disord. 2010;7(11):153. Gras F, Marintschev I, Wilharm A, Klos K, Mückley T, Hofmann GO. 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series. BMC Musculoskelet Disord. 2010;7(11):153.
20.
Zurück zum Zitat Gorczyca JT, Varga E, Woodside T, Hearn T, Powell J, Tile M. The strength of iliosacral lag screws and transiliac bars in the fixation of vertically unstable pelvic injuries with sacral fractures. Injury. 1996;27(8):561–4.PubMed Gorczyca JT, Varga E, Woodside T, Hearn T, Powell J, Tile M. The strength of iliosacral lag screws and transiliac bars in the fixation of vertically unstable pelvic injuries with sacral fractures. Injury. 1996;27(8):561–4.PubMed
21.
Zurück zum Zitat van Zwienen CM, van den Bosch EW, Snijders CJ, Kleinrensink GJ, van Vugt AB. Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures. J Orthop Trauma. 2004;18(9):589–95.PubMed van Zwienen CM, van den Bosch EW, Snijders CJ, Kleinrensink GJ, van Vugt AB. Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures. J Orthop Trauma. 2004;18(9):589–95.PubMed
22.
Zurück zum Zitat Kraemer W, Hearn T, Tile M, Powell J. The effect of thread length and location on extraction strengths of iliosacral lag screws. Injury. 1994;25(1):5–9.PubMed Kraemer W, Hearn T, Tile M, Powell J. The effect of thread length and location on extraction strengths of iliosacral lag screws. Injury. 1994;25(1):5–9.PubMed
23.
Zurück zum Zitat Carlson DA, Scheid DK, Maar DC, Baele JR, Kaehr DM. Safe placement of S1 and S2 iliosacral screws: the "vestibule" concept. J Orthop Trauma. 2000;14(4):264–9.PubMed Carlson DA, Scheid DK, Maar DC, Baele JR, Kaehr DM. Safe placement of S1 and S2 iliosacral screws: the "vestibule" concept. J Orthop Trauma. 2000;14(4):264–9.PubMed
24.
Zurück zum Zitat Kaiser SP, Gardner MJ, Liu J, Routt ML Jr, Morshed S. Anatomic determinants of sacral dysmorphism and implications for safe iliosacral screw placement. J Bone Jt Surg Am. 2014;96(14):e120. Kaiser SP, Gardner MJ, Liu J, Routt ML Jr, Morshed S. Anatomic determinants of sacral dysmorphism and implications for safe iliosacral screw placement. J Bone Jt Surg Am. 2014;96(14):e120.
25.
Zurück zum Zitat Wagner D, Kamer L, Sawaguchi T, Richards GR, Noser H, et al. Critical dimensions of trans-sacral corridors assessed by 3D CT models: Relevance for implant positioning in fractures of the sacrum. J Orthop Res. 2017;35(11):2577–84.PubMed Wagner D, Kamer L, Sawaguchi T, Richards GR, Noser H, et al. Critical dimensions of trans-sacral corridors assessed by 3D CT models: Relevance for implant positioning in fractures of the sacrum. J Orthop Res. 2017;35(11):2577–84.PubMed
26.
Zurück zum Zitat Wagner D, Kamer L, Sawaguchi T, Noser H, Uesugi M, et al. Space available for trans-sacral implants to treat fractures of the pelvis assessed by virtual implant positioning. Arch Orthop Trauma Surg. 2019;139(10):1385–91.PubMed Wagner D, Kamer L, Sawaguchi T, Noser H, Uesugi M, et al. Space available for trans-sacral implants to treat fractures of the pelvis assessed by virtual implant positioning. Arch Orthop Trauma Surg. 2019;139(10):1385–91.PubMed
27.
Zurück zum Zitat Wendt H, Gottschling H, Schröder M, Marintschev I, Hofmann GO, et al. Recommendations for iliosacral screw placement in dysmorphic sacrum based on modified in-out-in corridors. J Orthop Res. 2019;37(3):689–96.PubMed Wendt H, Gottschling H, Schröder M, Marintschev I, Hofmann GO, et al. Recommendations for iliosacral screw placement in dysmorphic sacrum based on modified in-out-in corridors. J Orthop Res. 2019;37(3):689–96.PubMed
28.
Zurück zum Zitat Wagner D, Hofmann A, Kamer L, Sawaguchi T, Richards RG, et al. Fragility fractures of the sacrum occur in elderly patients with severe loss of sacral bone mass. Arch Orthop Trauma Surg. 2018;138(7):971–7.PubMed Wagner D, Hofmann A, Kamer L, Sawaguchi T, Richards RG, et al. Fragility fractures of the sacrum occur in elderly patients with severe loss of sacral bone mass. Arch Orthop Trauma Surg. 2018;138(7):971–7.PubMed
29.
Zurück zum Zitat Simonian PT, Routt ML, Harrington RM, Mayo KA, Tencer AF. Biomechanical simulation of the anteroposterior compression injury of the pelvis. An understanding of instability and fixation. Clin Orthop Relat Res. 1994;309:245–56. Simonian PT, Routt ML, Harrington RM, Mayo KA, Tencer AF. Biomechanical simulation of the anteroposterior compression injury of the pelvis. An understanding of instability and fixation. Clin Orthop Relat Res. 1994;309:245–56.
30.
Zurück zum Zitat Dujardin FH, Roussignol X, Hossenbaccus M, Thomine JM. Experimental study of the sacroiliac joint micromotion in pelvic disruption. J Orthop Trauma. 2002;16(2):99–103.PubMed Dujardin FH, Roussignol X, Hossenbaccus M, Thomine JM. Experimental study of the sacroiliac joint micromotion in pelvic disruption. J Orthop Trauma. 2002;16(2):99–103.PubMed
31.
Zurück zum Zitat Schep NW, Haverlag R, van Vugt AB. Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma. 2004;57(6):1299–302.PubMed Schep NW, Haverlag R, van Vugt AB. Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma. 2004;57(6):1299–302.PubMed
32.
Zurück zum Zitat Ecker TM, Jost J, Cullmann JL, Zech WD, Djonov V, et al. Percutaneous screw fixation of the iliosacral joint: a case-based preoperative planning approach reduces operating time and radiation exposure. Injury. 2017;48(8):1825–30.PubMed Ecker TM, Jost J, Cullmann JL, Zech WD, Djonov V, et al. Percutaneous screw fixation of the iliosacral joint: a case-based preoperative planning approach reduces operating time and radiation exposure. Injury. 2017;48(8):1825–30.PubMed
33.
Zurück zum Zitat Gusic N, Grgorinic I, Fedel I, Lemac D, Bukvic N, et al. Fluoroscopic iliosacral screw placement made safe. Injury. 2017;48(Suppl 5):S70–S7272.PubMed Gusic N, Grgorinic I, Fedel I, Lemac D, Bukvic N, et al. Fluoroscopic iliosacral screw placement made safe. Injury. 2017;48(Suppl 5):S70–S7272.PubMed
34.
Zurück zum Zitat Takao M, Hamada H, Sakai T, Sugano N. Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation. Arch Orthop Trauma Surg. 2019;139(2):189–95.PubMed Takao M, Hamada H, Sakai T, Sugano N. Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation. Arch Orthop Trauma Surg. 2019;139(2):189–95.PubMed
35.
Zurück zum Zitat Pieske O, Landersdorfer C, Trumm C, Greiner A, Wallmichrath J, et al. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: accuracy of screw position, injury reduction and complications in 71 patients with 136 screws. Injury. 2015;46(2):333–9.PubMed Pieske O, Landersdorfer C, Trumm C, Greiner A, Wallmichrath J, et al. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: accuracy of screw position, injury reduction and complications in 71 patients with 136 screws. Injury. 2015;46(2):333–9.PubMed
36.
Zurück zum Zitat Matityahu A, Kahler D, Krettek C, Stöckle U, Grutzner PA, et al. Three-dimensional navigation is more accurate than two-dimensional navigation or conventional fluoroscopy for percutaneous sacroiliac screw fixation in the dysmorphic sacrum: a randomized multicenter study. J Orthop Trauma. 2014;28(12):707–10.PubMed Matityahu A, Kahler D, Krettek C, Stöckle U, Grutzner PA, et al. Three-dimensional navigation is more accurate than two-dimensional navigation or conventional fluoroscopy for percutaneous sacroiliac screw fixation in the dysmorphic sacrum: a randomized multicenter study. J Orthop Trauma. 2014;28(12):707–10.PubMed
37.
Zurück zum Zitat Wang JQ, Wang Y, Feng Y, Han W, Su YG, et al. Percutaneous sacroiliac screw placement: a prospective randomized comparison of robot-assisted navigation procedures with a conventional technique. Chin Med J. 2017;130(21):2527–34.PubMedPubMedCentral Wang JQ, Wang Y, Feng Y, Han W, Su YG, et al. Percutaneous sacroiliac screw placement: a prospective randomized comparison of robot-assisted navigation procedures with a conventional technique. Chin Med J. 2017;130(21):2527–34.PubMedPubMedCentral
38.
Zurück zum Zitat Kim JW, Oh CW, Oh JK, Lee HJ, Min WK, et al. Percutaneous iliosacral screwing in pelvic ring injury using three-dimensional fluoroscopy. J Orthop Sci. 2013;18(1):87–92.PubMed Kim JW, Oh CW, Oh JK, Lee HJ, Min WK, et al. Percutaneous iliosacral screwing in pelvic ring injury using three-dimensional fluoroscopy. J Orthop Sci. 2013;18(1):87–92.PubMed
39.
Zurück zum Zitat Berger-Groch J, Lueers M, Rueger JM, Lehmann W, Thiesen D, Kolb JP, Hartel MJ, Grossterlinden LG. Accuracy of navigated and conventional iliosacral screw placement in B- and C-type pelvic ring fractures. Eur J Trauma Emerg Surg. 2020;46(1):107–13.PubMed Berger-Groch J, Lueers M, Rueger JM, Lehmann W, Thiesen D, Kolb JP, Hartel MJ, Grossterlinden LG. Accuracy of navigated and conventional iliosacral screw placement in B- and C-type pelvic ring fractures. Eur J Trauma Emerg Surg. 2020;46(1):107–13.PubMed
40.
Zurück zum Zitat Fischer S, Vogl TJ, Marzi I, Zangos S, Wichmann JL, et al. Percutaneous cannulated screw fixation of sacral fractures and sacroiliac joint disruptions with CT-controlled guidewires performed by interventionalists: single center experience in treating posterior pelvic instability. Eur J Radiol. 2015;84(2):290–4.PubMed Fischer S, Vogl TJ, Marzi I, Zangos S, Wichmann JL, et al. Percutaneous cannulated screw fixation of sacral fractures and sacroiliac joint disruptions with CT-controlled guidewires performed by interventionalists: single center experience in treating posterior pelvic instability. Eur J Radiol. 2015;84(2):290–4.PubMed
41.
Zurück zum Zitat Theologis AA, Burch S, Pekmezci M. Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation: comparison with traditional fluoroscopy. Bone Jt J. 2016;98(5):696–702. Theologis AA, Burch S, Pekmezci M. Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation: comparison with traditional fluoroscopy. Bone Jt J. 2016;98(5):696–702.
42.
Zurück zum Zitat Zwingmann J, Südkamp NP, König B, Culemann U, Pohlemann T, et al. Intra- and postoperative complications of navigated and conventional techniques in percutaneous iliosacral screw fixation after pelvic fractures: Results from the German Pelvic Trauma Registry. Injury. 2013;44(12):1765–72.PubMed Zwingmann J, Südkamp NP, König B, Culemann U, Pohlemann T, et al. Intra- and postoperative complications of navigated and conventional techniques in percutaneous iliosacral screw fixation after pelvic fractures: Results from the German Pelvic Trauma Registry. Injury. 2013;44(12):1765–72.PubMed
43.
Zurück zum Zitat Rommens PM, Hessmann MH. Staged reconstruction of pelvic ring disruption: differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions. J Orthop Trauma. 2002;16(2):92–8.PubMed Rommens PM, Hessmann MH. Staged reconstruction of pelvic ring disruption: differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions. J Orthop Trauma. 2002;16(2):92–8.PubMed
44.
Zurück zum Zitat Ebraheim NA, Xu R, Biyani A, Nadaud MC. Morphologic considerations of the first sacral pedicle for iliosacral screw placement. Spine. 1997;22(8):841–6.PubMed Ebraheim NA, Xu R, Biyani A, Nadaud MC. Morphologic considerations of the first sacral pedicle for iliosacral screw placement. Spine. 1997;22(8):841–6.PubMed
45.
Zurück zum Zitat Grossterlinden L, Rueger J, Catala-Lehnen P, Rupprecht M, Lehmann W, Rücker A, Briem D. Factors influencing the accuracy of iliosacral screw placement in trauma patients. Int Orthop. 2011;35(9):1391–6.PubMed Grossterlinden L, Rueger J, Catala-Lehnen P, Rupprecht M, Lehmann W, Rücker A, Briem D. Factors influencing the accuracy of iliosacral screw placement in trauma patients. Int Orthop. 2011;35(9):1391–6.PubMed
46.
Zurück zum Zitat Khaled SA, Soliman O, Wahed MA. Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation. Eur J Trauma Emerg Surg. 2015;41(4):387–92.PubMed Khaled SA, Soliman O, Wahed MA. Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation. Eur J Trauma Emerg Surg. 2015;41(4):387–92.PubMed
47.
Zurück zum Zitat Griffin DR, Starr AJ, Reinert CM, Jones AL, Whitlock S. Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure? J Orthop Trauma. 2003;17(6):399–405.PubMed Griffin DR, Starr AJ, Reinert CM, Jones AL, Whitlock S. Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure? J Orthop Trauma. 2003;17(6):399–405.PubMed
48.
Zurück zum Zitat Quade J, Busel G, Beebe M, Auston D, Shah AR, et al. Symptomatic iliosacral screw removal after pelvic trauma-incidence and clinical impact. J Orthop Trauma. 2019;33(7):351–3.PubMed Quade J, Busel G, Beebe M, Auston D, Shah AR, et al. Symptomatic iliosacral screw removal after pelvic trauma-incidence and clinical impact. J Orthop Trauma. 2019;33(7):351–3.PubMed
49.
Zurück zum Zitat Hessmann MH, Rickert M, Hofmann A, Rommens PM, Buhl M. Outcome in pelvic ring fractures. Eur J Trauma Emerg Surg. 2010;36(2):124–30.PubMed Hessmann MH, Rickert M, Hofmann A, Rommens PM, Buhl M. Outcome in pelvic ring fractures. Eur J Trauma Emerg Surg. 2010;36(2):124–30.PubMed
Metadaten
Titel
Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study
verfasst von
Pol Maria Rommens
Eva Mareike Nolte
Johannes Hopf
Daniel Wagner
Alexander Hofmann
Martin Hessmann
Publikationsdatum
15.04.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 6/2021
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-020-01362-9

Weitere Artikel der Ausgabe 6/2021

European Journal of Trauma and Emergency Surgery 6/2021 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.