Steady state imaging of the thoracic vasculature using inversion recovery FLASH and SSFP with a blood pool contrast agent

verfasst von: Mauricio S Galizia, Jennifer A Febbo, Andrada R Popescu, Xiaoming Bi, Jeremy Collins, Michael Markl, Robert R Edelman, James Carr

Erschienen in: Journal of Cardiovascular Magnetic Resonance | Sonderheft 1/2012

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Background

Although contrast-enhanced first-pass MRA (FP-MRA) is frequently used to visualize the thoracic vasculature, it may not be ideal for the assessment of the aortic root due to poor image quality and motion artifact. Blood-pool contrast agents remain within the intravascular space for several hours, allowing vessels to be imaged longer and therefore improving spatial resolution. The purpose of this study is to compare steady-state magnetic resonance angiography (SS-MRA) following injection of a blood-pool contras agent to first-pass MR angiography (FP-MRA) in adults with thoracic aortic disease.

Methods

25 patients (14 men, 11 women) with suspect thoracic aortic disease disease underwent MRA on a 1.5 T scanner (Magnetom Aera and Avanto; Siemens Medical Solutions). The MRA protocol consisted of FP-MRA followed by SS-MRA after intravenous injection of gadofosveset trisodium (Ablavar, Lantheus Medical Imaging). FP-MRA consisted of a breath-held ECG-gated FLASH acquisition in a sagittal oblique orientation with the following imaging parameters: TR/TE: 2.8/1.0, flip angle 25°, FOV 343x500 mm, matrix 264x512, slice thickness 1.5 mm, voxel size 1.3 x 1.0 x 1.0 mm, GRAPPA x 2, 20 second acquisition. 0.03 mmol/kg of gadofosveset was injected intravenously at 1cc/sec in an antecubital vein. Contrast bolus timing was achieved using care bolus technique. SS-MRA consisted of free-breathing ECG-gated IR-FLASH and IR-SSFP in a sagittal oblique orientation. IR-FLASH had the following parameters: TR/TE/TI: 3.5/1.5/260, flip angle 18°, and IR-SSFP had: TR/TE/TI: 3.3/1.5/260, flip angle 70°. Both sequences had FOV 326x380, matrix 440x512, slice thickness 1.5 mm, voxel 0.7 x 0.7 x 1.0 mm, GRAPPA x 2, and 3 minute acquisition. Respiratory gating was achieved using a navigator acquisition with an average acceptance window of 35%. For quantitative analysis, orthogonal dimensions of the thoracic aorta were measured at several locations. Signal-to-noise ratio (SNR) was also measured for both techniques by placing regions of interest in the aortic root and the ascending aorta. For qualitative analysis, two independent reviewers evaluated both FP-MRA and SS-MRA images separately. The aortic root and the ascending aorta were scored on an image quality scale of 1-4.

Results

There was no significant difference in aortic dimensions at all anatomic locations between FP-MRA and SS-MRA. SNR was higher for SS-MRA compared to FP-MRA. Image quality scores were higher for SS-MRA compared to FP-MRA. Thoracic aortic aneurysms were detected equally between both techniques.

Conclusions

SS-MRA following injection of blood pool contrast agent was comparable to FP-MRA for measurement of aortic dimensions. SNR and image quality was higher with SS-MRA. SS-MRA may be a useful adjunct to FP-MRA in cases of bolus mistiming, or may potentially replace FP-MRA, thereby simplifying MRA assessment of the thoracic vasculature.

Funding

None.
This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Metadaten
Titel
Steady state imaging of the thoracic vasculature using inversion recovery FLASH and SSFP with a blood pool contrast agent
verfasst von
Mauricio S Galizia
Jennifer A Febbo
Andrada R Popescu
Xiaoming Bi
Jeremy Collins
Michael Markl
Robert R Edelman
James Carr
Publikationsdatum
01.12.2012
Verlag
BioMed Central
DOI
https://doi.org/10.1186/1532-429X-14-S1-P51

Weitere Artikel der Sonderheft 1/2012

Journal of Cardiovascular Magnetic Resonance 1/2012 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.