Skip to main content
Erschienen in: Odontology 4/2019

29.03.2019 | Original Article

Surface nanoscale profile of WaveOne, WaveOne Gold, Reciproc, and Reciproc blue, before and after root canal preparation

verfasst von: A. Mothanna K. AlRahabi, Raghied M. Atta

Erschienen in: Odontology | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

This study aimed to compare the surface topographies and nanoscale profiles of intact and used WaveOne, WaveOne Gold, Reciproc, and Reciproc blue nickel–titanium (NiTi) instruments. Sixteen NiTi instruments were evaluated; four from each one of WaveOne (25/0.08), WaveOne Gold (25/0.07), Reciproc (25/0.08), and Reciproc blue (25/0.08) files. Each instrument was used to prepare four curved canals. A three-dimensional nanoscale surface profiler was used to assess instrument surfaces before and after root canal instrumentation. The data were analyzed with one-way analysis of variance using SPSS 21.0 software and set significance at P < 0.05. There were significant differences in surface topography between NiTi instruments. Intact WaveOne and WaveOne Gold instruments had the highest values, followed by the Reciproc and Reciproc blue instruments (P < 0.05). Used WaveOne and WaveOne Gold instruments had the highest values, followed by Reciproc and Reciproc blue instruments (P < 0.05). Some indications of microcracks in qualitatively intact Reciproc blue files were observed, and minor surface cracks in used WaveOne Gold instruments were also observed. Used WaveOne, Reciproc, and Reciproc blue instruments exhibited cracks and microcavities. WaveOne Gold and Reciproc blue instruments had significantly higher levels of surface distortion after root canal instrumentation, and WaveOne exhibited the lowest level of surface deformation. Each of the Reciprocating instruments was safely used to prepare four canals without incident. The three-dimensional stylus profiler provided valuable assessments of the surface topographies of NiTi instruments.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Hasheminia SM, Farhad A, Sheikhi M, Soltani P, Hendi SS, et al. Cone-beam computed tomographic analysis of canal transportation and centering ability of single-file systems. J Endod. 2018;44:1788–91.CrossRefPubMed Hasheminia SM, Farhad A, Sheikhi M, Soltani P, Hendi SS, et al. Cone-beam computed tomographic analysis of canal transportation and centering ability of single-file systems. J Endod. 2018;44:1788–91.CrossRefPubMed
2.
Zurück zum Zitat Yamazaki-Arasaki A, Cabrales R, Santos MD, Kleine B, Prokopowitsch I. Topography of four different endodontic rotary systems, before and after being used for the 12th time. Microsc Res Tech. 2012;75:97–102.CrossRefPubMed Yamazaki-Arasaki A, Cabrales R, Santos MD, Kleine B, Prokopowitsch I. Topography of four different endodontic rotary systems, before and after being used for the 12th time. Microsc Res Tech. 2012;75:97–102.CrossRefPubMed
3.
Zurück zum Zitat De-Deus G, Silva EJNL, Vieira VTL, Belladonna FG, Elias CN, Plotino G, et al. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the reciproc files. J Endod. 2017;43:462–6.CrossRef De-Deus G, Silva EJNL, Vieira VTL, Belladonna FG, Elias CN, Plotino G, et al. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the reciproc files. J Endod. 2017;43:462–6.CrossRef
4.
Zurück zum Zitat Pereira ES, Gomes RO, Leroy AM, Singh R, Peters OA, Bahia MG, et al. Mechanical behavior of M-Wire and conventional NiTi wire used to manufacture rotary endodontic instruments. Dent Mater. 2013;29:e318-e24. Pereira ES, Gomes RO, Leroy AM, Singh R, Peters OA, Bahia MG, et al. Mechanical behavior of M-Wire and conventional NiTi wire used to manufacture rotary endodontic instruments. Dent Mater. 2013;29:e318-e24.
5.
Zurück zum Zitat Shen Y, Qian W, Abtin H, Gao Y, Haapasalo M. Effect of environment on fatigue failure of controlled memory wire nickel–titanium rotary instruments. J Endod. 2012;38:376–80.CrossRefPubMed Shen Y, Qian W, Abtin H, Gao Y, Haapasalo M. Effect of environment on fatigue failure of controlled memory wire nickel–titanium rotary instruments. J Endod. 2012;38:376–80.CrossRefPubMed
6.
Zurück zum Zitat Zupanc J, Vahdat-Pajouh N, Schäfer E. New thermomechanically treated NiTi alloys—a review. Int Endod J. 2018;51:1088–103.CrossRefPubMed Zupanc J, Vahdat-Pajouh N, Schäfer E. New thermomechanically treated NiTi alloys—a review. Int Endod J. 2018;51:1088–103.CrossRefPubMed
7.
Zurück zum Zitat Plotino G, Grande NM, Cotti E, Testarelli L, Gambarini G. Blue treatment enhances cyclic fatigue resistance of vortex nickel–titanium rotary files. J Endod. 2014;40:1451–3.CrossRefPubMed Plotino G, Grande NM, Cotti E, Testarelli L, Gambarini G. Blue treatment enhances cyclic fatigue resistance of vortex nickel–titanium rotary files. J Endod. 2014;40:1451–3.CrossRefPubMed
8.
Zurück zum Zitat Hieawy A, Haapasalo M, Zhou H, Wang Z-j, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments. J Endod. 2015;41:1134–8.CrossRefPubMed Hieawy A, Haapasalo M, Zhou H, Wang Z-j, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments. J Endod. 2015;41:1134–8.CrossRefPubMed
9.
Zurück zum Zitat De-Deus G, Moreira E, Lopes H, Elias C. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J. 2010;43:1063–8.CrossRef De-Deus G, Moreira E, Lopes H, Elias C. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J. 2010;43:1063–8.CrossRef
10.
Zurück zum Zitat Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel–titanium rotary instruments. J Endod. 2013;39:258–61.CrossRefPubMed Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel–titanium rotary instruments. J Endod. 2013;39:258–61.CrossRefPubMed
11.
Zurück zum Zitat Kiefner P, Ban M, De-Deus G. Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments? Int Endod J. 2014;47:430–6.CrossRef Kiefner P, Ban M, De-Deus G. Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments? Int Endod J. 2014;47:430–6.CrossRef
12.
Zurück zum Zitat Webber J, Machtou P, Pertot W, Kuttler S, Ruddle C, West J. The WaveOne single-file reciprocating system. Roots. 2011;1:28–33. Webber J, Machtou P, Pertot W, Kuttler S, Ruddle C, West J. The WaveOne single-file reciprocating system. Roots. 2011;1:28–33.
13.
Zurück zum Zitat Ruddle CJ. Single-file shaping technique achieving a gold medal result. Dent Today. 2016;35:1–7. Ruddle CJ. Single-file shaping technique achieving a gold medal result. Dent Today. 2016;35:1–7.
14.
Zurück zum Zitat Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne gold nickel–titanium instruments. J Endod. 2016;42:1536–9.CrossRefPubMed Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne gold nickel–titanium instruments. J Endod. 2016;42:1536–9.CrossRefPubMed
15.
Zurück zum Zitat Webber J. Shaping canals with confidence: WaveOne GOLD single-file reciprocating system. Roots. 2015;1:34–40. Webber J. Shaping canals with confidence: WaveOne GOLD single-file reciprocating system. Roots. 2015;1:34–40.
16.
Zurück zum Zitat Keskin C, Inan U, Demiral M, Keleş A. Cyclic fatigue resistance of Reciproc blue, Reciproc, and WaveOne Gold reciprocating instruments. J Endod. 2017;43:1360–3.CrossRefPubMed Keskin C, Inan U, Demiral M, Keleş A. Cyclic fatigue resistance of Reciproc blue, Reciproc, and WaveOne Gold reciprocating instruments. J Endod. 2017;43:1360–3.CrossRefPubMed
17.
Zurück zum Zitat Hanan ARA, Meireles DAd S, Júnior EC, Hanan S, Kuga MC, Bonetti Filho I. Surface characteristics of reciprocating instruments before and after use—a SEM analysis. Braz Dent J. 2015;26:121–7.CrossRefPubMed Hanan ARA, Meireles DAd S, Júnior EC, Hanan S, Kuga MC, Bonetti Filho I. Surface characteristics of reciprocating instruments before and after use—a SEM analysis. Braz Dent J. 2015;26:121–7.CrossRefPubMed
18.
Zurück zum Zitat Sağlam BC, Görgül G. Evaluation of surface alterations in different retreatment nickel–titanium files: AFM and SEM study. Microsc Res Tech. 2015;78:356–62.CrossRef Sağlam BC, Görgül G. Evaluation of surface alterations in different retreatment nickel–titanium files: AFM and SEM study. Microsc Res Tech. 2015;78:356–62.CrossRef
19.
Zurück zum Zitat Uslu G, Özyürek T, Yılmaz K. Comparison of alterations in the surface topographies of HyFlex CM and HyFlex EDM nickel–titanium files after root canal preparation: a three-dimensional optical profilometry study. J Endod. 2018;44:115–9.CrossRefPubMed Uslu G, Özyürek T, Yılmaz K. Comparison of alterations in the surface topographies of HyFlex CM and HyFlex EDM nickel–titanium files after root canal preparation: a three-dimensional optical profilometry study. J Endod. 2018;44:115–9.CrossRefPubMed
20.
Zurück zum Zitat Ferreira F, Barbosa I, Scelza P, Russano D, Neff J, Montagnana M, et al. A new method for the assessment of the surface topography of NiTi rotary instruments. Int Endod J. 2017;50:902–9.CrossRefPubMed Ferreira F, Barbosa I, Scelza P, Russano D, Neff J, Montagnana M, et al. A new method for the assessment of the surface topography of NiTi rotary instruments. Int Endod J. 2017;50:902–9.CrossRefPubMed
21.
Zurück zum Zitat Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971;32:271–5.CrossRefPubMed Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971;32:271–5.CrossRefPubMed
22.
Zurück zum Zitat Alapati SB, Brantley WA, Svec TA, Powers JM, Mitchell JC. Scanning electron microscope observations of new and used nickel–titanium rotary files. J Endod. 2003;29:667–9.CrossRefPubMed Alapati SB, Brantley WA, Svec TA, Powers JM, Mitchell JC. Scanning electron microscope observations of new and used nickel–titanium rotary files. J Endod. 2003;29:667–9.CrossRefPubMed
23.
Zurück zum Zitat Kuhn G, Tavernier B, Jordan L. Influence of structure on nickel–titanium endodontic instruments failure. J Endod. 2001;27:516–20.CrossRefPubMed Kuhn G, Tavernier B, Jordan L. Influence of structure on nickel–titanium endodontic instruments failure. J Endod. 2001;27:516–20.CrossRefPubMed
24.
Zurück zum Zitat Lopes HP, Elias CN, Vieira MV, Vieira VT, de Souza LC, Dos Santos AL. Influence of surface roughness on the fatigue life of nickel–titanium rotary endodontic instruments. J Endod. 2016;42:965–8.CrossRefPubMed Lopes HP, Elias CN, Vieira MV, Vieira VT, de Souza LC, Dos Santos AL. Influence of surface roughness on the fatigue life of nickel–titanium rotary endodontic instruments. J Endod. 2016;42:965–8.CrossRefPubMed
25.
Zurück zum Zitat Nair AS, Tilakchand M, Naik BD. The effect of multiple autoclave cycles on the surface of rotary nickel–titanium endodontic files: an in vitro atomic force microscopy investigation. J Conserv Dent. 2015;18:218.CrossRefPubMedPubMedCentral Nair AS, Tilakchand M, Naik BD. The effect of multiple autoclave cycles on the surface of rotary nickel–titanium endodontic files: an in vitro atomic force microscopy investigation. J Conserv Dent. 2015;18:218.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Inan U, Aydin C, Uzun O, Topuz O, Alacam T. Evaluation of the surface characteristics of used and new ProTaper instruments: an atomic force microscopy study. J Endod. 2007;33:1334–7.CrossRefPubMed Inan U, Aydin C, Uzun O, Topuz O, Alacam T. Evaluation of the surface characteristics of used and new ProTaper instruments: an atomic force microscopy study. J Endod. 2007;33:1334–7.CrossRefPubMed
27.
Zurück zum Zitat Tripi TR, Bonaccorso A, Tripi V, Condorelii GG, Rapisarda E. Defects in GT rotary instruments after use: an SEM study. J Endod. 2001;27:782–5.CrossRefPubMed Tripi TR, Bonaccorso A, Tripi V, Condorelii GG, Rapisarda E. Defects in GT rotary instruments after use: an SEM study. J Endod. 2001;27:782–5.CrossRefPubMed
28.
Zurück zum Zitat Cazaux J. Recent developments and new strategies in scanning electron microscopy. J Microsc. 2005;217:16–35.CrossRefPubMed Cazaux J. Recent developments and new strategies in scanning electron microscopy. J Microsc. 2005;217:16–35.CrossRefPubMed
29.
Zurück zum Zitat Vorburger TV, Rhee H-G, Renegar TB, Song J-F, Zheng A. Comparison of optical and stylus methods for measurement of surface texture. Int J Adv Manuf Technol. 2007;33:110–8.CrossRef Vorburger TV, Rhee H-G, Renegar TB, Song J-F, Zheng A. Comparison of optical and stylus methods for measurement of surface texture. Int J Adv Manuf Technol. 2007;33:110–8.CrossRef
30.
Zurück zum Zitat Poon CY, Bhushan B. Comparison of surface roughness measurements by stylus profiler, AFM and non-contact optical profiler. Wear. 1995;190:76–88.CrossRef Poon CY, Bhushan B. Comparison of surface roughness measurements by stylus profiler, AFM and non-contact optical profiler. Wear. 1995;190:76–88.CrossRef
32.
Zurück zum Zitat Firstov G, Vitchev R, Kumar H, Blanpain B, Van Humbeeck J. Surface oxidation of NiTi shape memory alloy. Biomaterials. 2002;23:4863–71.CrossRefPubMed Firstov G, Vitchev R, Kumar H, Blanpain B, Van Humbeeck J. Surface oxidation of NiTi shape memory alloy. Biomaterials. 2002;23:4863–71.CrossRefPubMed
33.
Zurück zum Zitat Pirani C, Paolucci A, Ruggeri O, Bossù M, Polimeni A, Gatto MRA, et al. Wear and metallographic analysis of WaveOne and Reciproc NiTi instruments before and after three uses in root canals. Scanning. 2014;36:517–25.CrossRef Pirani C, Paolucci A, Ruggeri O, Bossù M, Polimeni A, Gatto MRA, et al. Wear and metallographic analysis of WaveOne and Reciproc NiTi instruments before and after three uses in root canals. Scanning. 2014;36:517–25.CrossRef
34.
Zurück zum Zitat Barbosa I, Ferreira F, Scelza P, Neff J, Russano D, Montagnana M, et al. Defect propagation in NiTi rotary instruments: a noncontact optical profilometry analysis. Int Endod J. 2018;51:1271–8.CrossRefPubMed Barbosa I, Ferreira F, Scelza P, Neff J, Russano D, Montagnana M, et al. Defect propagation in NiTi rotary instruments: a noncontact optical profilometry analysis. Int Endod J. 2018;51:1271–8.CrossRefPubMed
35.
Zurück zum Zitat Ferreira FG, Barbosa IB, Scelza P, Montagnana MB, Russano D, Neff J, et al. Noncontact three-dimensional evaluation of surface alterations and wear in NiTi endodontic instruments. Braz Oral Res. 2017;31:0074–9. Ferreira FG, Barbosa IB, Scelza P, Montagnana MB, Russano D, Neff J, et al. Noncontact three-dimensional evaluation of surface alterations and wear in NiTi endodontic instruments. Braz Oral Res. 2017;31:0074–9.
Metadaten
Titel
Surface nanoscale profile of WaveOne, WaveOne Gold, Reciproc, and Reciproc blue, before and after root canal preparation
verfasst von
A. Mothanna K. AlRahabi
Raghied M. Atta
Publikationsdatum
29.03.2019
Verlag
Springer Japan
Erschienen in
Odontology / Ausgabe 4/2019
Print ISSN: 1618-1247
Elektronische ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-019-00424-8

Weitere Artikel der Ausgabe 4/2019

Odontology 4/2019 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.